TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Similar documents
DEREHAM MEMORIAL HALL

Technical Information

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

New Theatre Royal Lincoln Technical Information

Technical Specification

Technical Specification

INFORMATION FOR VISITING COMPANIES

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

TECHNICAL SPECIFICATIONS

Main House Technical Specification

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Specification for the Alley Theatre, Strabane

Technical specifications Main theatre. Sound

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

HIRE AND TECHNICAL INFORMATION

Dr JOHN GALLAGHER CONCERT CHAMBER

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

2017 TECHNICAL SPECIFICATIONS

Summary. Access and Parking

Technical Specification Pavilion Dance

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Theatre Technical Specifications

Stage. Get In & Parking

Theatre Technical Specification

Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

MAIN HOUSE TECHNICAL SPECIFICATION

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

CENTRE FOR PERFORMING ARTS

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Technical Specifications Nov 2016

ISLAND HALL TECHNICAL INFORMATION

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Information

Technical Specification

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Matt Dann Cultural Centre

TECHNICAL SPECIFICATION

The Haymarket Basingstoke Technical Specifications

Technical Services and Specification

Main House Technical Specifications

Cornerstone Technical Specifications 2018 / V1

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

The Georgian Theatre Royal Technical Information For Visiting Companies

Technical Specifications Updated 01/10/2017. Stage

MAIN AUDITORIUM TECHNICAL INFORMATION

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

Darlington Hippodrome Technical Specification

TECHNICAL SPECIFICATIONS

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

CHELSEA THEATRE. Technical Specifications

John Leslie Theatre. Technical Specifications. Updated July 2018

Technical Specifications

MAIN THEATRE TECHNICAL SPECIFICATION

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

The Lights Technical Guide June 2017

Technical Director of Production Andrew Quick Ext 252

Technical Specification. Updated: April 2016

Lighthouse Theatre Technical Specification

Technical Specification Ardhowen Theatre

Patriots Theater at the War Memorial Technical Data

TECHNICAL SPECIFICATIONS

Technical Specification Ver 01/16

Backstage Accommodation (Ground Floor Mezzanine Level 1 Floor above Loading Bay)

Latrobe Performing Arts Centre

Dugdale Centre Technical Specification

Technical Specifications

WYCOMBE SWAN Wycombe Arts Management Ltd registered in England and Wales No Registered Office: 16 High Holborn, London, WC1V 6BX

Pleasance London Main House Visiting Company Information Pack May 2017

Information for Incoming Companies

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

UNIVERSITY CONCERT HALL. Technical Specification

Technical Specifications

HIRERS INFORMATION PACK For further technical information or enquiries please contact:

RPAC REDLANDS PERFORMING ARTS CENTRE

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

The Anvil Technical Specifications

Compass Theatre - Technical Information Pack

Sandusky State Theatre Technical Specifications

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Hirers Technical Information Pack

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Technical Data Sheet

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Technical Pack. Attenborough Arts Centre

Arlington Arts Tech Spec 2018

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Arcadia Performing Arts Center Technical Specifications and Information

Transcription:

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE Wyllyotts Theatre, Wyllyotts Place, Darkes Lane, Potters Bar, Hertfordshire. EN6 2HN 1

Contents Pg. 3: Pg. 4: Pg. 5: Pg. 6: Pg. 7: Pg. 8: Wyllyotts Theatre Contacts Logistics Stage Measurements Scenery Special Effects Flying System House Tabs Dressing Rooms Communications Lighting Equipment Sound Equipment Digital Cinema Alternative content Power Rostra Masking Stage Management Equipment Hire Staffing 2

TECHNICAL SPECIFICATION Updated May 2016 Contacts: Peter Windsor - Technical Manager Peter.Windsor@hertsmereleisure.co.uk / 01707 660 067 Gary Fisher - Assistant Technical Manager Robert Hearn - Senior Technician Logistics: Entrance to the auditorium from street level. Stage Door dimensions: Height: 2.55m 8'5" Width: 1.18m 3'10" Please note that there is minimal parking space at the stage door and loading bay. The Stage door is also an emergency exit and vehicles cannot be parked in this area during performances. There is a car park adjacent to the Theatre. Stage Measurements: Upstage width: 14.70m 48'2" Downstage (with proscenium arch): 9.80m 32'0" Depth: 6.35m 20'10" Stage Thrust (when installed): 1.22m 4'0" Proscenium arch height: 4.00m 13'0" Scenery: Should conform to Licensing Regulations. (See conditions of hire: Schedule D: 8, 9.) Special Effects: For the use of pyrotechnics, smoke, dry ice, firearms or a strobe or any other special effects, the theatre requires at least 14 days notice for permission to be granted. (See Conditions of Hire: Schedule D: 10.) 3

Flying System: 11 Hemp lines operated SR, SWL 90Kg (H10 is on triple purchase, SWL 125Kg) 4 x 500kg Pilewind motors for lighting bars (3 overhead, 1 FOH) See flying plot. House Tabs: Are motorised and have a variable running speed with a maximum of 9 seconds. They can be operated from prompt corner, sound control area or lighting control box. The variable speed can only be operated from prompt corner. Dressing Rooms (Three rooms): No.1 Up to Twelve people, 3 hand basins and 7 lit mirrors. No.2 Up to eight people, with shower, hand basin and 4 lit mirrors No.3 Up to seven people, with shower, hand basin and 4 lit mirrors, All dressing rooms have 6' costume rails Additional dressing room accommodation is available by prior arrangement with the Theatre management. Communications Tecpro Intercom System installed with the following positions: Prompt corner Stage right Lighting/projection control room Sound control area Stage left followspot position Stage right followspot position 5 x SMH210 Headset 2 x DT109 Headset 5 x DT108 Headset 9 x BP111 Beltpack 3 x ASL Beltpack 4

Lighting Equipment: Power: Three phase 200amp. Dimming: Control: Strand WallRack Digital Dimmers: 96 x 10A circuits. LSC E-Pro Digital Dimmers in portable rack: 24 x 10A circuits 4 x Soccapex out (Wyllyotts hold 4 x fan out) ETC ION complete with riggers remote. Distribution: 96 Circuits. 1 6: F.O.H. Perch SL 7 14: F.O.H 2 (7-12 paired outer to inner) 15 20: F.O.H. Perch SR 21 38: F.O.H. 1 (37 + 38 paired at outer) 39 40: Front of stage Dip circuits 41 56: LX1 (+ 2 x 16A hard power) 57 72: LX2 (+ 2 x 16A hard power) 73 88: LX3 (+ 2 x 16A hard power) 89 96: Stage dip circuits paired SL and SR Luminaries: 6 Selecon 24/40 profile spots 1200w 9 Selecon 18/34 profile spots 1200w 7 Strand SL 15/32 profile spots 575w 6 Strand SL 23/50 profile spots 575w 2 Source 4 Jnr 50 profile spots 575w 5 Selecon pebble convex 1200w 4 Selecon Fresnels 1200w 5 Starlette Fresnels 1000w 8 Patten 743 Fresnels 1000w 20 Par 64 1K (assorted lamps available) 12 Cupo (S4 Par copies) 575w 4 Par 64 Floorcans 6 Coda 4x 500w 15 Coda 1x 500w 12 Chauvet R2 LED wash lights Follow Spots: 2 x Robert Juliatt Manon (1200w MSD) on RJ leg stands) DMX Outlets: Sound area, Prompt corner with 5 way DMX splitter/buffer, Dimmer room Additional lighting equipment can be hired by arrangement with the Technical Manager. 5

Sound Equipment: Distribution: Paired stage boxes SL/SR: 24 XLR send, 4 XLR return, 4 NL4 aux DSC stage box: 8 XLR send, 4 XLR return, 4 NL4 aux Full patching facilities. Dante 32/16 Digital snake. Positioned DSR Mixer: Yamaha Ls9-32 w/dante Situated stage right in the auditorium, to the rear of the raked seating. Output: F.O.H.: Mid/Hi: L&R - 2 x JBL SRX 722 C - 2 x JBL SRX 712 Lo: C - 1 x JBL SRX 728s (dual 18 ) Delay: 8 x JBL Control 28 (2x row of 4 @ 20 and 40 from proscenium) Foldback: 4 x JBL G2 Eon (active) 2 x Yamaha Club Series wedges (passive) Amplifiers: F.O.H.: 4 x QSC PLX2502 1 x QSC CX4 Crossover: DBX Driverack PA Foldback: 2 x QSC RMX 750 Processing: Built-in to the Yamaha Ls9 Microphones: 3 x Shure SM58 3 x Shure SM57 2 x AKG D 321 1 x AKG C 568 EB 2 x Shure SMbeta87 1 x Sennheiser MD 421 2 x AKG SE300 with CK91 head 3 x Sure SMbeta98 (drum mics) 1 x AKG D112 (kick drum mic) Direct: Injection Boxes 1 x EMO single DI 2 x Stageline Stereo DI 2 x BSS single DI Playback: 1 x Tascam MD-CD 1 1 x Tascam MD301-MKII 1 x American Audio USB Player 6

Digital Cinema / Alternative content: Formats: Screen: Projection: Sound: Dolby Show Server, DCP. Xpand 3D emitters Live Satellite Streaming Blu-ray LG player Perlux 180, electrically flown roller screen. See flying plot for location. Barco CP2K-15c Christie LX700 (7000 ansi lumen) Dolby CP650 processor with: 7.1 surround from Dolby Show Server 5.1 surround from Tascam DVD player Stereo from all other sound sources Please contact the Theatre for further details on cinema usage. Power: Single phase, 100amp, Busbar Chamber situated upstage left fitted CEEFORM 30mA RCD (sound phase) 3 phase, 125amp CEEFORM socket upstage left 8 x 13amp sockets, fitted 30mA RCD, prompt corner (LX phase) 4 x 13amp sockets, fitted 30mA RCD, upstage left wall (sound phase) 4 x 13amp sockets, fitted 30mA RCD, upstage right wall (sound phase) 1 x 16amp sockets, stage right (LX phase) 2 x 13amp sockets, stage right (LX phase) 2 x 13amp sockets, fitted RCD stage front at floor level 2 x 16amp sockets per stage LX bar Rostra: 6 x 8' x 4' Steeldeck sections 2 x 4'6" x 4' Steeldeck sections 2 x 3 Steeldeck treads to suit 48 legs 24" legs for all of the above 48" legs for all of the above 12 legs for all of the above Note: Stage thrust extension comprises all Steeldeck sections on 48" legs. 7

Masking: 3 x Pairs black serge tabs (2 pair consistently flown as black back cloth and mid-stage tabs) 3 x Black twill borders 5 (1 pleated) 4 x 6' x 18' twill soft legs 2 x Black twill borders 3 (stored) Stage Management: 25 x Stage weights 12 x Stage Braces (assorted lengths) 16 x Boom arms 04 x boom base Additional Equipment Available to Hire: Sound: 2 x Sennheiser Ew300 G1 handheld radio mic set (channel 70) 4 x Sennheiser G2 lavaliere radio mic set (channel 70) 8 x Sennheiser Ew300 G3 lavaliere radio mic sets (channel 41) 3 x Sennheiser MKH 416 Lighting: Effects: 1 x Strobe 2 x 18" Mirror ball 2 x Telrad followspot sights 1 x ASL BlinQ 1 x RGB LED Star cloth 36 x 18 1 x Haze Base Pro (2ch DMX or stand alone) 1 x Haze Base Battery hazer (hand held haze machine) 1 x Jem ZR22 Smoke Machine (DMX & XLR Remote) 2 x Martin Jem Magnum 1800 smoke machines 4 x Pulse 1m RGB LED batons 2 x Bubble Machines 2 x UV Cannons For a quotation on these additional hire items, please contact the Technical Manager. Staffing The Wyllyotts Theatre provides 2 technical staff on site at all times whilst you are occupying the building. They are both there to advise you on the best or easiest way to achieve the result you require. They can train any of your technical staff, stage crew or stage management in the correct operation of the theatre systems and will be on hand throughout your time with us in case of any problems. They cannot, however, actually design your lighting, sound or staging as they have other work to complete for the theatre. Neither can they actually operate any equipment for you during a performance as they have other duties to perform at that time. The Wyllyotts Theatre can provide rigging / operating crew for you, if you require, but this will be at additional cost to your company. Details of current crew costs can be obtained from the Technical Manager. We endeavour to keep these as low as possible for you, but this requires detailed information and good organisation on your part. 8