Localization of Noise Sources in Large Structures Using AE David W. Prine, Northwestern University ITI, Evanston, IL, USA

Similar documents
Vibration Measurement and Analysis

Using the BHM binaural head microphone

A New "Duration-Adapted TR" Waveform Capture Method Eliminates Severe Limitations

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

EMI/EMC diagnostic and debugging

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

3500/42E Vibration Monitor

Upon the completion of this testing program, we will update this section of our Engineering Manual.

Improving the accuracy of EMI emissions testing. James Young Rohde & Schwarz

CM-1UTP CAMERA MASTER UTP ADAPTOR

Standard Operating Procedure of nanoir2-s

Hugo Technology. An introduction into Rob Watts' technology

Using the new psychoacoustic tonality analyses Tonality (Hearing Model) 1

DPD80 Visible Datasheet

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

DPD80 Infrared Datasheet

MODEL PA II-R (1995-MSRP $549.00)

An Introduction to Vibration Analysis Theory and Practice

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Application Note AN-LD09 Rev. B Troubleshooting Low Noise Systems. April, 2015 Page 1 NOISE MEASUREMENT SYSTEM BASELINES INTRODUCTION

MachineryMate 800 operating guide Handheld vibration meter

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

MclNTOSH MODEL C-4 and C-4P

Assessing and Measuring VCR Playback Image Quality, Part 1. Leo Backman/DigiOmmel & Co.

Natural Radio. News, Comments and Letters About Natural Radio January 2003 Copyright 2003 by Mark S. Karney

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

Diamond Cut Productions / Application Notes AN-2

Transporting NV Standardized Testing from the Lab to the Production Environment

Faithful Sound Uniform Loudness Distribution Reproduction. Source. System

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

J R Sky, Inc. tel: fax:

WaveDriver 20 Potentiostat/Galvanostat System

Getting Started with the LabVIEW Sound and Vibration Toolkit

A Matlab toolbox for. Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE

9070 Smart Vibration Meter Instruction Manual

Agilent 87405C 100 MHz to 18 GHz Preamplifier

OLD WORLD AUDIO U33A VARI-MU STEREO COMPRESSOR INSTALLATION AND OPERATING NOTES

Simple Harmonic Motion: What is a Sound Spectrum?

WVR500 Waveform/Vector Monitor

Application note for Peerless XLS 12" subwoofer driver

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Quad-to-quad correlated motion in FLASH

RoomMatch Utility RMU208 TECHNICAL DATA SHEET. small-format foreground/fill loudspeaker. Key Features. Technical Specifications

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

Techniques for Extending Real-Time Oscilloscope Bandwidth

Musical Acoustics Lecture 15 Pitch & Frequency (Psycho-Acoustics)

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Academia Sinica, Institute of Astronomy & Astrophysics Hilo Operations

USB Mini Spectrum Analyzer User s Guide TSA5G35

Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Spectrum Analyser Basics

4.9 BEAM BLANKING AND PULSING OPTIONS

PicoScope 6407 Digitizer

Agilent ESA Series Spectrum Analyzers

T E S T - R E P O R T. No for. SLG 42 MOBY Component

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

Eventide Inc. One Alsan Way Little Ferry, NJ

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Calibrate, Characterize and Emulate Systems Using RFXpress in AWG Series

Mastering Phase Noise Measurements (Part 3)

1.2 General Description

GÜRALP CMG-3T BROADBAND SEISMOMETER

Technical Description

Enhanced Diagnostics through Ultrasound Imaging

Acoustical Noise Problems in Production Test of Electro Acoustical Units and Electronic Cabinets

UNIVERSITY OF DUBLIN TRINITY COLLEGE

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

4 MHz Lock-In Amplifier

MAD A-Series...Flat Panel Surface Planar Arrays

Anti-Mode 8033Cinema User's Manual

Full Disclosure Monitoring

Physics. Approximate Timeline. Students are expected to keep up with class work when absent.

M R X

혼합도메인오실로스코프와 USB 스팩트럼분석기를 이용한광대역노이즈최신측정기술소개

USB-TG124A Tracking Generator User Manual

Adam Aleweidat Undergraduate, Engineering Physics Physics 406: The Acoustical Physics of Music University of Illinois at Urbana-Champaign Spring 2013

FLOW INDUCED NOISE REDUCTION TECHNIQUES FOR MICROPHONES IN LOW SPEED WIND TUNNELS

Specifications. Reference Documentation. Performance Conditions

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Absolute performance 1

Advanced Sensor Technologies

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

TIME RESOLVED XAS DATA COLLECTION WITH AN XIA DXP-4T SPECTROMETER

Electro-Optic Beam Deflectors

The characterisation of Musical Instruments by means of Intensity of Acoustic Radiation (IAR)

Measuring Small. The technique of measuring very small Lateral Tape Motion (LTM) Gary Collins, P.E.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

VLA-VLBA Interference Memo No. 15

Appendix D. UW DigiScope User s Manual. Willis J. Tompkins and Annie Foong

LX20 OPERATORS MANUAL

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Transcription:

Localization of Noise Sources in Large Structures Using AE David W. Prine, Northwestern University ITI, Evanston, IL, USA Abstract This paper describes application of AE monitoring techniques to localize the sources of large noises in civil structures. These noises occur during operation of moveable portions of a structure in such things as lift bridges and moveable sports stadium roofs. The use of straightforward AE monitoring techniques can provide clear unambiguous location of these noise sources. Introduction Audible noises in large steel structures are extremely difficult to localize by means of audible sound. The reason for this is that the steel provides an excellent path for the sound and carries it great distances. Furthermore, the velocity of sound in steel is over 17 times faster than in air so that re-radiated sound from the steel can appear to the ear to come from multiple sources. The first step in correcting the structural problem responsible for the noises is to determine where they are coming from. ITI has successfully dealt with the sound localization problem in several steel bridges by applying AE to localize the sound. The AE technique uses high frequency contact sensors coupled to the steel structure. Processes such as stick-slip in bearings and bolt fretting typically produce acoustic energy in a very broad spectrum. The logic behind this application of AE to the noise localization problem is that the high frequencies (a few hundred kilohertz) are carried with little attenuation in steel but are quickly attenuated in air. Therefore, an array of high frequency sensors attached to the structure can accurately determine the location of the source by simple time of arrival measurement. This approach coupled with high pass filtering of the AE signals eliminates the confusing airborne low frequency sound and generally produces unambiguous source location. In this paper we will describe a case study performed on the moveable roof of a baseball stadium. The stadium roof is made up of seven segments shaped like the leaves of an oriental fan. The interior five segments are moveable. They pivot on ball and cup bearings located above home plate and are driven by electric powered bogies that run on a track structure above the outfield wall. Set-up and Procedure A Vallen AMS 3 digital acoustic emission monitoring system was used to record and analyze the signals from the sensors. This system makes a series of measurements (peak amplitude, arrival time, energy etc.) on the incoming signals and stores these readings in digital format. Additionally, the AMS3 digitizes and stores waveform data for one or more channels of information using a sampling rate of 10MHz at 12 bit resolution. The system is capable of real time plotting and analysis as well as post-test analysis. The system was set up in the Terrace Level seating area directly under the pivot points for the roof. A 250-foot 8- channel coaxial cable was used to connect the sensors and preamplifiers to the AMS3. The Vallen preamplifiers provide 34db or more of amplification and their low output impedance allows use of connecting cables up to 1000 219

feet in length. The sensors were 650 khz resonant devices and were coupled to the structure using silicone grease. We used these high frequency sensors to reduce the sensitivity of the AE system. The high frequency portion of the noise signal has very high amplitude and will easily cause saturation of the monitoring system. We still experienced some amplitude saturation with the 650 khz sensors but were able to accurately determine the source location. The sensors were held in place by magnetic clamps. A total of three AE sensors were used. Table 1 below summarizes the locations of the AE sensors. Sensor & Plot Color Channel 1 Channel 2 Channel 3 Location Top surface of bearing Bearing end of roof truss Bearing support structure Table 1 AE Sensor locations In addition to the AE sensors two laser displacement sensors were used to monitor bearing movement. These devices have sensitivity in the micron range and a maximum frequency response of approximately 20Hz. Their range is limited to 6mm. This limited range forced us to use the displacement sensors on the first 6 mm of motion of each run. Our primary purpose in applying these sensors was to see if we could detect any transient motion accompanying the generation of a loud AE burst. If such could be detected it would provide additional evidence as to the origin of the noises (i.e. bearing stick slip). Table 2 below summarizes the displacement sensor placements. Sensor & Plot Color Location PA0 Top of bearing and truss attachment PA1 Bearing support and truss attachment Table 2 Displacement sensor placements Results Each pivot bearing was separately tested. A minimum of one closing and one opening was run for each of the five bearings. All data were recorded on a hard disk and the data was backed up to a flash memory card post-test on-site. CDROM backup was generated in the ITI laboratory following our return. The AMS 3 has a self-calibration feature wherein each AE channel can be individually pulsed and the signals received at the other channels are tabulated. As a matter of routine a self-calibration was run before and after each test run to insure the integrity of the sensor-couplant-preamp-cable set for each channel. All calibrations indicated no detectable changes in the structure to monitor path. The self- calibrations also showed that system sensitivity remained constant throughout the tests. The primary analysis of the AE data utilized the first hit channel (FHC) for each acoustic event. FHC=1 indicates the source for that event is in the bearing. FHC=2 indicates the source for that event is somewhere in the truss and FHC=3 indicates a source in the bearing support. The use of FHC analysis is dictated by the complex nature of the structure which makes conventional planer location impractical. This analysis shows 220

conclusively that the source of the loud noises is the pivot bearing. The overwhelming portion of first hits occur at channel 1 for all but one quiet bearing. Furthermore the channel 1 first hits are much higher in amplitude than the other first hits. In the following section we will present the data from typical bearings. The following figures show the data plots for one of the Roof Segments. Figure 1 Amplitude Distribution for Closing of Left #2 Roof Segment Figure 2 Peak Amplitude vs. Time for Closing of Left #2 Roof Segment 221

This bearing is typical of those tested. There is also structural noise which is consistent with high live loads caused by high bearing friction. Both figures 1 and 2 clearly show that the bearing is the noise source. Figures 3 and 4 show the plots for an opening of the same bearing and an additional closure. Figure 3 Amplitude Distribution for Opening and Additional Closing of Left #2 Roof Segment Figure 4 Peak Amplitude vs. Time for Opening and additional Closing of Left #2 Roof Segment 222

These runs provide further clear confirmation of the bearing noise source. Additionally, this bearing during the opening cycle showed a clear correlation of displacement anomalies with large AE events. Figure 5 below shows a 0.3 second portion of the displacement between the roof truss and the bearing base plotted on the same time scale as the AE. Figure 5 Showing AE Peak Amplitude and Displacement of Truss Relative to Bearing Base on Same Time Scale for L2 Bearing Four out of five of the bearings produced significant noise but only two (L2 and R2) showed positive correlation between displacement and high amplitude AE events. Difficulties in aligning the sensors with their very limited range was the cause of this problem. Figure 6 shows the displacement data and AE peak amplitude for bearing R2 for a 0.30 second interval. Both sensors for the R2 bearing show transient movement that correlates with high amplitude AE. The frequency response of the displacement sensor is not sufficient to show an accurate representation of the transient movement. However, the sensors clearly show discontinuities in the time-displacement plot which correlate with high amplitude acoustic events. 223

Figure 6 Showing AE Peak Amplitude and Displacement of Truss Relative to Bearing Top on Same Time Scale for R2 Bearing Summery and Conclusions Acoustic emission (AE) monitoring clearly showed that the loud noises generated during roof openings and closings are produced by the pivot bearings. The AE monitor used for these tests has an audio monitor that heterodynes the high frequency AE down to the audible range. Loud bangs from the roof opening were accompanied by audible pops from the AE system audio monitor and coincided with the real time detection of first hits on AE channel 1, the bearing sensor. A simple first hit analysis of the AE data showed that the AE associated with the loud audible impact like noises all came from the bearings. Furthermore, the bearing signals were overwhelmingly higher in amplitude than all other AE signals. The remainder of the AE came from the structure and is consistent with previous observations on steel structures undergoing live loading. These signals likely are produced by bolted connections in the roof trusses. The driving live load is the action of the bearing friction and the roof driving force flexing the structure. Additional confirmation of the source of the noise was provided by laser displacement sensors. These devices consist of a measuring head and a target. We used two sensors. One was attached to the top of the bearing with the target attached to the roof truss end and the other sensor was attached to the bearing base with the target attached to the roof truss end. Two bearings showed clear correlation between high amplitude AE events and transient movement detected by the displacement sensors. This data is consistent with stick slip operation of the bearing. These tests confirm that the pivot bearings are not operating properly. 224