TABLE OF CONTENTS INTRODUCTION

Similar documents
USER MANUAL (SSDL-3201RGB)

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

192 Channel DMX Controller

LED-PAR200B USER MANUAL. COLORsplash 200B

Spectra Batten (Order code: LEDJ95)

ORDER CODE: EQLED65 USER MANUAL

VRL PAR-1745 Par Lamp

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

PRO PAR HEX 12. User Manual

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

LED-BANK4 USER MANUAL. COLORbank 4

Stratos Duo RGB. User Manual. Order code: EQLED371

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

LED Spere Direct Control 30 ORDERCODE 41125

SquareLED - Aura Bar & Matrix Beam Light 100

USER S MANUAL

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

NEO-STB-0004 Neo-Flash 300 RGB User Manual

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

Led Dynamic DMX Tri Curtain Manual

Fusion 120 Zoom. User Manual. Order code: EQLED068

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

LED PAR 36 USER MANUAL

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

DICE6 (LCG-1207)-User Manual USER MANUAL DICE6. LCG-1207 (7x 12W-RGBAWV 6-in-1)

Mini LED Pin Spot Light Model: PLS00571

Glow P54 White LED Par

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

MONOPRICE. SoftStage 80-Watt COB LED Stage PAR (RGB) with 30 and 80 Lenses. User's Manual P/N

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

LED IP65 Slimline Par RGBWA +UV 7x12W

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

Glow P7B LED Par Beam

CYBER PAK. User Instructions.

LED Pixel Track Pro ORDERCODE 42205

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

LEDWash RGBW USER MANUAL

Snapshot. Obey 10 DMX Controller USER MANUAL

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

Jelly Par Profile System Introduction Unpacking: Introduction: Customer Support: Warning! Caution! User Instructions

thinpar 38

EPAR QW. User Instructions

EPAR QA. User Instructions

Snapshot. LED Mushroom USER MANUAL. OK on Dimmer Outdoor OK Sound-Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User-Serviceable

DMX-7 USER MANUAL. Universal DMX Controller

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

Introduction: The Dekker is part of American DJ s continuing pursuit for creating high quality affordable intelligent fixtures.

Opti Tri White Par. User Instructions

USER GUIDE IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL

RIO TRI PAR MICROH. Information. Technical 104 F(40 C) 9.6 in (245 mm) Width. 9.6 in (245 mm) Height. 8.0 in (205 mm) Weight

American DJ. User Instructions. Model: Mega Bar 50RGB

WASH MOVING HEAD M7W15RGBW USER MANUAL. For safety, please read this user manual carefully before initial use.

SPECIFICATIONS: Model: Supply Voltage: LED: Weight: Size: Fuse: Power Consumption: Working Position: Duty Cycle: DMX Channels:

USER MANUAL LED PAR64 RGBWA

Stage Wash 7x 10W LED Moving Head (RGBW)

Flat LED Par Can Light

MH-X50+ LED spot moving head. user manual

广州朗闻光电有限公司 GUANGZHOU LONGMAN PRO LIGHT FACTORY CO,. LTD. Vpower L350. System No.: LQ FULL RGBW

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

Owner Handbook. Jupiter Blackhole. LED UV Flood

ALO 060 DMX LED scanner

TABLE OF CONTENTS. Page 2 of 12 MotionFaçade LED User Manual (Rev. 10)

ENGLISH LED Octostrip Set MKII V1

TABLE OF CONTENTS. 1. Before you Begin... 3 What is Included... 3 Unpacking Instructions... 3 Text Conventions... 3 Icons... 3 Safety Notes...

BROTHER, BROTHER & SONS

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

IP65 Rated: Suitable For Outdoor Use

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

4LEDKIT-DJ USER MANUAL. LED Tricolor 4-PAR Lighting Kit. Please read this manual carefully and proper take care of this manual.

Information specifically for: V1.1

Cyclo DMX HO High Output. user manual

Ref. No.: LCB-48IP LED COLORUNIT 16X3W TRI DMX

LED Bar 240/8 RGB LED floodlight. user manual

Outdoor Stage PAR 12 3W Tri LED PAR. user manual

Snapshot DMX MEGA STROBE III. User Manual

Hex-color RGBAW+UV LED strip light

LED Techno Strobe RGB ST-4000RGB USER MANUAL

Design LED 36. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 11/17/06

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

LED Flood Panel 150 LED floodlight. user manual

1. BEFORE YOU BEGIN INTRODUCTION CONTROL FEATURES... 5 Additional Features... 5 PRODUCT OVERVIEW SETUP... 6

PRODUCT SPECIFICATIONS

Cameleon Bar 24-3 ORDERCODE 42695

ENGLISH Spectral M800 Q4 IP65

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

Design LED 36WA. Elation Professional 4295 Charter Street Los Angeles, Ca Rev 3/08/07

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

LED ZOOM PAR Please R ead O ver T his M anual B efore O perating T he L ight F ixture.

LED Thunder S-150 Code 1097

ElektraLite lightstream

Truss Light COB LED 30W

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

Transcription:

1

TABLE OF CONTENTS INTRODUCTION... 2 MAIN FEATURES... 3 UNPACKING... 3 SAFETY WARNING... 3 PANEL REVIEW... 4 INSTALLATION AND SETTING... 4 1. MULTI-FIXTURES CONNECTION... 4 2. LAMP BODY INSTALLATION... 5 2. DMX CHANNEL SUMMARY... 5 3. CHANNEL FUNTIONS... 6 4. ABOUT EACH CHANNEL... 7 MAINTENANCE... 10 1.TROUBLESHOOTING... 10 TENICAL SPECIFICATION... 11 INTRODUCTION Thank you for purchasing the VRL PAR-363 High Power Par Lamp. There are three 2

operation modes available Auto sound activation master/slave The PAR-363 also features 8 built-in programs. The product has a long lifespan and low power consumption. Before you begin, please read instructions carefully. If you should have any problem please contact your nearest distributor. MAIN FEATURES DMX-512 control, 6 channels DMX, AUTO, SOUND-ACTIVE, MASTER/SLAVE RGB control with 255 grades RGB total dimmer is 0~100% Shutter speed is 10flashes/sec ~10secs /flash 36X3W LED UNPACKING VRL PAR-363 High Power Par Lamp USER MANUAL SAFETY WARNING For your convenient and accurate operation, please read the following information carefully. Suitable for indoor use only. Put it in a dry, well -ventilated place in case of short cut caused by erosion of moisture and rain. Do not install nearby hot sources in case that rising temperature of lamp damages itself. Do not barrier vent in order to ventilate well and dissipate in time. Connect the fixture with power source, which has a ground line, and voltage of power source should accord with rating voltage. If fuse was damaged, change the same type. You can only choose accessories the manufacturer provides when need repairing. Ambient temperature of the lamp should not exceed 40 If any problem, contact with professional technicians working in our after-sales service department. 3

PANEL REVIEW Press FUN button: Switch to function menu or return to previous menu Press UP/DOWN: Adjusts the currently activated field. The four points will blink indicating a value change. Press ENTER: Enter into sub-menu or confirm the current value. INSTALLATION AND SETTING 1. MULTI-FIXTURES CONNECTION DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). 4

2. LAMP BODY INSTALLATION Notes: do not install it nearby the curtain or flammable materials. Only for indoor use. OPERATION 1.SET DIPSWITCHES Each fixture occupies 6 DMX channels. DMX 512 signal can control multi-fixtures together, however you must set the DMX address of each lamp first. Different DMX address will lead to different movements. You can set DMX address from 1~506 on the multi-function display panel. Switch on power supply and after finishing resetting, the panel will show 001,that is to say DMX address is 1 and the first lamp has been controlled by 1~6 channels. In turn the second fixture has been controlled by 007~012 channels. (When panel shows 001,press UP button until it shows 007.Then just press ENTER button). In the same way, the third fixture has been controlled by 013~018 channels and the panel shows013. Through this method, you can control multi-fixtures to perform different movements. 2. DMX CHANNEL SUMMARY 5

3. CHANNEL FUNTIONS DISPLAY FUNCTION VALUE 001-506 DMX address MODE M-DM DMX mode M-AU AUTO mode Notes: Only one lamp can be set as Master and the left are Slaves (Slaves set to DMX mode with DMX address 001 ). Do not connect the Slaves lamp with controller. M-SO SOUND mode Notes: Only one lamp can be set as Master and the left are Slaves (Slaves set to DMX mode with DMX address 001 ). Do not connect the Slaves lamp with controller. PRCO PR1~8 8 built-in programs Pr1-4 means skip Pr5-8 means fade SPCO SP01~15 Auto speed SP01: 0.1sec/step, SP15: 10secs/step TEST ALL Check all channels with motors RED Check red channels GREEN Check green channels BLUE Check blue channels DSPL STND Display bites normally REV Display bytes upside down REST REST/ON Reset (Press ENTER button to enter into REST menu and the screen reads flashing REST. Then press UP/DOWN button and the screen reads flashing ON. If you press ENTER again, the light engine resets again) 6

4. ABOUT EACH CHANNEL Channel 1:DMX MODE Ch DMX Function CH2 CH3 CH4 CH5 CH6 0~24 RGB Red 0~255 Green 0~255 Blue 0~255 Strobe Speed Dimmer 0~255 0~255 25~49 1 50~74 2 75~99 3 100~124 CH1 4 Auto 125~149 No No No speed No 5 function function function function 150~174 6 175~199 7 200~224 8 225~255 Sound-active No program function Channel 2: RED When CH1 is 0~24 red 255 carmine 0 0 7

Channel 3: GREEN When CH1 is 0~24 green 255 bottle green Channel 4:Blue When CH1 is 0~24 0 0 blue 255 navy blue Channel 5: Strobe When CH1 is 0~24 0 0 strobe speed 255 slowest 16 fastest 15 no strobe 0 no strobe Notes: CH2~4 decides brightness. When CH2, CH3, CH4 is 0, there is no brightness. 8

When CH1 is 25~224: AUTO speed 255 slowest 0 fastest Channel 6: RGB Dimming When CH1is 0~24: RGB brightness 255 0 0 brightest 9

MAINTENANCE 1.TROUBLESHOOTING Problem Probable cause(s) Suggested remedy No power source Check if power source is on or cord works well. Fixtures does not work Fuse burnt Cut off power source and change the same type fuse. If fuse was burnt on end, it may be the problem of connection; Find qualified professors to repair. False or incomplete data connection Check, repair or change the data line. Ensure connection is well and the first lamp s single input is connected with the controller output. Reset normally, but console abnormally or no response False address setting Problem of signal connector of some fixtures Check DMX address. Pull out the signal output and input of one fixture. Then connect both directly. If it works well, this fixture is proved to be the failed one. Handle the rest fixtures alike to check which fixture has problems. If any problem, please connect the technician. 10

TECHNICAL SPECIFICATION Type------------------------------------------------------------------VRL PAR-363 High Power Par Lamp LED Number& Voltage----------------------------------------------------------------------- 36X3W LED Channel--------------------------------------------------------------------------------------------6 Channels Power------------------------------------------------------------------------------------------------------74W Voltage------------------------------------------------------------------------------------AC100V~AC220V Electrical current---------------------------------------------------------------------------------0.6a ~1.2A Total lumens------------------------------------------------------------------------------------------675lm Max light intensity------------------------------------------------------------------------------------2214cd Dimension----------------------------------------------------------------------------------φ250*H385MM Weight-----------------------------------------------------------------------------------------------------3.2KG 11