LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

Similar documents
Illustrated Feature. Options

XML LED X M L L E D. Explosionproof Linear LED Lighting

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

EXLUX ECOLUX C-LUX 6480 Series

Applications. Standard Materials

EXLUX ECOLUX 6480 Series

WLB SERIES HID Lighting for Hose Down Applications

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Champ-Pak Wall Pack Luminares

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas

NEW! Wide Area Lighting - Rough Service Fluorescent. MULTIVOLTAGE Automatically Operates at 120 to 277 VAC 50 or 60 Hz *1142 only

3 Large Housing. Assembly Guide. To order a UNIPAK fixture, see page 29. Complete luminaire consists of : To order separate components, order

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

WLC60 Heavy Duty LED Light - PWM Dimmable

PROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

Pendant Light Fitting IEC Series 6470/2

PHONE: (303) FAX: (970) WEBSITE:

7 Lighting Technology

LUNERA SERIES L7 _ GEN 3

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803

Sign Illuminating Ballasts

LINEAR DOWNLIGHT - PENDANT DIRECT

Example: 2TG32L840-4-FS-02F-UNV-DIM. Color Length Door Frame Lens Voltage Driver Options. 4 4' FS Flat Steel FA Flat Aluminum RA Regressed Aluminum

PENDANT MOUNT - DIRECT/INDIRECT

VIA 3 - PATTERNS PENDANT DIRECT W W W. L U M E N W E R X. C O M

NEC/CEC: Simultaneous Exposure (Class I, Division 2/Class II, Division 1) Fixtures Outside Type (Salt Water) Type 4X IP66. Standard Materials

SERIES 6LCDB79V Lensed Low Voltage LED

VIA 2 LED WALL INDIRECT ASYMMETRIC V. 2 W W W. L U M E N W E R X. C O M

Seem 2. Preferred Light: Lighting for better color rendition and human preference. LED PERFORMANCE MOUNTING INFORMATION. recessed companion

Model Material Lamp type LED color Voltage Distribution Lens

Pauluhn Apex. Linear, high bay LED luminaires designed for harsh & heavy industrial applications

FLUID VIEW 12V LED TAPE LIGHT

SERIES 6VLFL2X Lensed LED Downlight Lumen Flex

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

M A R I N E B R I G H T S O L U T I O N S

SubstiTUBE Value EM Fighter Tube Technical Datasheet

T5 LED Integrated Lamp

Modular Lube Lubrication Systems System Controls

Cyclo Series. user manual. MartinArchitectural

2-Piece LED Emergency Back-Up and Kits

ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output. IES File Performance Summary

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

VIA 1.5 LED PENDANT DIRECT W W W. L U M E N W E R X. C O M

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Channel Cable Tray - Accessories

CHALICE PENDANT LED DOWNLIGHT 70 Watt LED

Commercial Lighting Program TECHNICAL SPECIFICATION GUIDE. *Manitoba Hydro is a licensee of the Trademark and Official Mark.

Liner Quattro AC XB RGBW

Furnish and Deliver New Light Emitting Diode (LED) Fluorescent Light Tubes

M100 My White LED Indirect

EXPlora. Introduction

ArenaVision MVF404 exceptional optical efficiency

Photometric Test Report

IndyGo Facility Upgrades Project 35671EE

SPECIAL SPECIFICATION 2344 TMC Support Equipment

Number Eight Lighting Company 803/K2-HI-25-XX/DIM /FS-P-1-WH

Cylindrical Photoelectric Sensor CY-100 SERIES

Linealux L5 Linear Facade

Caveled Tunnel Lighting Series. SL-Caveled/100277AC (UL) - B Type - UL certified (E326344) Features. Typical Applications.

Linear Array with Intensity Adjustment

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Features. Specifications. Finish. Notes

PVM11LUNV1 Led LT FX 118W Features Descriptions Manufacturer Information Taxonomies, Classifications, and Categories Packaging

FAQ #1: But LEDs last forever, why do we even care about enduser replacement?

ArenaVision MVF404 exceptional optical efficiency

ROAD COMMISSION FOR OAKLAND COUNTY SPECIAL PROVISION FOR LIGHT EMITTING DIODE (LED) VEHICLE TRAFFIC SIGNALS

OMNIBLAST-E MODULAR LED FLOODLIGHTING SOLUTION FLEXIBILITY THROUGH MODULAR DESIGN SUPERIOR OPTICAL EFFICIENCY ADVANCED CONTROL OPTIONS

Photoelectric Sensors E3F2

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

RGB+W RGBWWA. TOTAL POWER CONSUMPTION 6.0 W/ft 12.0 W/ft. FIXTURE WATTAGE 6.0 W/ft 12.0 W/ft

Catalog. Industrial Plugs & Sockets The complete range

Figure 1: Device components

Number Eight Lighting Company 526 Portal Street, Cotati, CA 94931

Bartco Lighting 5761 Research Drive, Huntington Beach, CA

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

ILT-54HO-T5C/277 F54T5 HO > 0.98 ILT-39HO-T5C/277 F39T5 HO > 0.98 ILT-24HO-T5C/277 F24T5 HO > 0.

Rail 4 RM4D (Formerly Grande) LED. Wall

Figure 1. High Efficiency T8 LED Tube. Figure 3. Full View of Light High Efficiency T8 LED Tube

Lumencove Family. The highest quality light from the tightest spaces

LightWave Lighting Technology

CHALICE PENDANT LED DOWNLIGHT 150 Watt LED

Philips InstantFit LED PL-C/T Lamp

Seem 2. Individual units and continuous runs in 1" increments. Frosted acrylic lens provides uninterrupted illumination, without pixels or shadows.

DISTANCE BETWEEN FIXTURES. * 2 " [61mm] on 1ft configuration. 5-year limited warranty.

SPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment

PILOT COVE INTERIOR - INTEGRAL POWER SUPPLY ACTIVE WHITE (TUNABLE)

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Revolution Lighting Technologies (RVLT) 2280 Ward Ave. Docks 5&6, Simi Valley, CA 93065

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request

IP65. Specifications. White (4 300 K typical) Blue (470 nm) On-site or factory-programmable brightness. Black Silver Polished copper.

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

Forced Convection Laboratory Ovens

Transcription:

Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups A, B, C & D; Marine Type Electric Fixture Non-Recessed Outside Type (Salt Water); UL1598A; and Type 4X. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against dirt, water and moisture is necessary. Typical applications include: Oil drilling rigs Marine loading terminals Processing plants Pipeline pumping stations Water treatment plants Lubrication pits Features Choice of mountings: end brackets, swivel brackets and straight brackets. Thick 1/8 clear acrylic lens protects against possible broken glass from lamps. RigMaster fixtures are supplied with the following ballast: Class P low energy (E) ballasts which are equipped with an automatic thermally-activated protective device; offers protection against excessive voltage, internal ballast short circuiting, inadequate lamp maintenance and improper fixture application. 220- and 240-volt options are available in both 50 and 60 Hz. High-temperature nickel-cadmium battery has a life expectancy of 7 to 10 years. Battery charger indicator light and test switch are mounted inside the enclosure and visible through the clear lens. Heavy-duty telescoping lampholders. Fixtures are shipped complete with lamps. Swivel End Mount fixture comes standard with eyebolt on fixture end for connecting safety cable. Swivel Center Mount and Straight Center Mount fixtures come standard with cast mounts on fixture end for connecting safety cable. Standard Materials Reflector housings: extruded aluminum Door frame: 1/8 extruded aluminum Door clamps: heavy-duty plated spring steel holders: white urea plastic Gasket: neoprene Options Individually fused ballast: suffix F. Emergency battery pack: suffix EL 1. Emergency Battery Pack capability in moments of power interruption. Luminaire automatically switches to emergency mode, keeping one lamp illuminated for a minimum of 90 minutes. When AC power is restored, battery automatically recharges in 24 hours. Initial light output is 600-700 lumens. Illustrated Feature RM2232BUSW Four plated steel latches on each side of door assure integrity of fixture for areas as classified. Certifications and Compliances UL Standard: UL 1598, UL 844, UL 924 UL Listed: E10794 1106

Order using catalog numbering guide below or select catalog number from tables on following pages. Catalog Numbering Guide For RigMaster Metallic Fluorescent Fixtures RM 2 2 40 12 SS CB EL Series: RM - RigMaster Metallic Type: 32-32 W, T8 (Electronic) 40-40 W, (Electronic) 60-60 W, T12, HO 800 MA (48) 5 Mounting: CB- End SW- Swivel ST- Fixed Hazardous Rating: Class I, Division 2 Number of s: 2 - Two s Voltage 4: 12-120 V (40 W, T12) 27-277 V (40 W, T12) BU - 120-277 V, 50/60 Hz (32 W, T8; 60 W, T12) Ballast Type: SS- Solid State (40W, T12, Electronic) Only Options: EL- Emergency Battery Pack 3 F- Fuse Thermal Performance RigMaster Fixtures Ambient Temp ( F/ C) T Numbers Hazardous Classification Fixture Quantity Watt Type RM2232 2 32 265MA-RS 104/40 T-4 RM2240 2 40 430MA-RS 104/40 T-4 RM2260 2 60 800MA-HO 104/40 T-4 3 For 50 Hz with Emergency Battery Pack, consult factory for certification. 4 BU for 32 W, T8 and 60 W, T12 only. Voltage must be specified for 40 W, T12. 5 CW suffix not needed for 60 W since -20 F/-28 C starting provided as a standard. 1107

No. of s 3 Wattage Type Volts Bracket Type Catalog Number 2 32 T8 120-277 V, 50/60 Hz end RM2232BUCB 2 40 T12 120 V, 60 Hz end RM224012SSCB 2 40 T12 277 V, 60 Hz end RM224027SSCB Swivel End Bracket 2 60 T12 120-277 V, 50/60 Hz end RM2260BUCB 2 32 T8 120-277 V, 50/60 Hz swivel RM2232BUSW 2 40 T12 120 V, 60 Hz swivel RM224012SSSW 2 40 T12 277 V, 60 Hz swivel RM224027SSSW Swivel Center Bracket 2 60 T12 120-277 V, 50/60 Hz swivel RM2260BUSW 2 32 T8 120-277 V, 50/60 Hz straight RM2232BUST 2 40 T12 120 V, 60 Hz straight RM224012SSST 2 40 T12 277 V, 60 Hz straight RM224027SSST Straight Center Bracket 2 60 T12 120-277 V, 50/60 Hz straight RM2260BUST Replacement Parts Lens Mounting Brackets Sockets Description Lens and Frame Assembly Straight Bracket Angle Bracket Swivel Bracket Back-Straight Bracket Catalog Number RIGLENS RM3002SEM RM3002AEM RMBMSW RMBMST 60 W Spring Loaded RM60SRS 60 W Fixed Replacement RM60FRS 32 W Replacement RM32RS Mounting Accessories Safety Cable Galvanized Steel Cable Catalog Number Stainless Steel Cable Catalog Number 3 ft/0.9 m RMSC3GASL 3 ft/0.9 m RMSC3STSL 4 ft/1.2 m RMSC4GASL 4 ft/1.2 m RMSC4STSL Connecting Safety Cable Swivel Center Mount and Straight Center Mount fixture comes standard with cast mounts on fixture end for connecting safety cable. Swivel End Mount fixture comes standard with eyebolt on fixture end for connecting safety cable. 3 Fixtures shipped complete with lamps. 1108

RigMaster Metallic Fluorescent Luminaire Dimensions End Bracket Mounting 51.25"/1301.8 mm 47.0"/1193.8 mm C to C 8.10"/ 205.7 mm 8.10"/205.7 mm 5.42"/137.7 mm Swivel Bracket Mounting 12.50"/ 317.5 mm 2.00"/50.8 mm Ø 0.28"/ 7.0 mm Straight Bracket Mounting 6.75"/ 171.5 mm 17.6"/447.0 mm 9.75"/ 247.7 mm 10.35"/ 262.9 mm 11.0"/ 279.4 mm Fixture Bracket Type Weight in Lbs/Kgs End 35/15.9 Swivel 35/15.9 Straight 35/15.9 1109

RigMaster Metallic Fluorescent Luminaire Photometrics CATALOG NUMBER: RM2232BU Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-8. 32 Watt) tested at 120 V 0 1234 1234 1234 1234 1234 5 1234 1228 1227 1228 1224 117 15 1183 1187 1185 1187 1183 335 25 1106 1110 1109 1110 1106 512 s: Two Phillips 32 W, 4-foot F32T8/TL741fluorescents Ballast: Advance T-8, 32 Watt, catalog number ICN-2P32-SC 50/60 Hz, Instant Start, 120-277 V Based on: 2,850 Lumens per 35 984 990 996 990 984 620 TOTAL LUMINAIRE EFFICIENCY = 57.6% ZONAL LUMEN SUMMARY 45 813 823 830 823 813 634 CIE Type Direct ZONE LUMENS % LAMP % FIXT. 55 612 619 614 619 612 550 Plane: 0 90 0-30 964 16.9 29.4 65 364 375 381 375 364 368 Spacing Criteria: 1.3 1.3 0-40 1584 27.8 48.3 75 124 126 112 126 124 133 Shielding Angles: 1.0 0.0 0-60 2767 48.6 84.3 85 9 7 7 7 9 12 0-90 3281 57.6 100.0 90 1 1 1 1 90-180 0 0.0 0.0 0-180 3281 57.6 100.0 CATALOG NUMBER: RM2232BU Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-12. 34 Watt) tested at 120 V 0 1132 1132 1132 1132 1132 5 1124 1128 1126 1128 1124 107 15 1085 1089 1090 1089 1085 308 25 1003 1010 1011 1010 1003 465 s: 2 Philips 34 Watt (4 foot, T-12) F4OCW/RS/EW Ballast: Advance T-12, 34 Watt, catalog number REL-2S40-SC 50/60 Hz, Instant Start, 120 V Based on: 2,650 Lumens per 35 882 889 888 889 882 555 TOTAL LUMINAIRE EFFICIENCY = 55.1% ZONAL LUMEN SUMMARY 45 726 730 726 730 726 561 CIE Type Direct ZONE LUMENS % LAMP % FIXT. 55 535 535 533 535 535 477 Plane: 0 90 0-30 880 16.6 30.1 65 322 316 311 316 322 314 Spacing Criteria: 1.2 1.2 0-40 1435 27.1 49.2 75 121 112 104 112 121 121 0-60 2473 46.7 84.7 85 9 7 6 7 9 11 0-90 2919 55.1 100.0 90 0 0 0 0 0 90-180 0 0.0 0.0 0-180 2919 55.1 100.0 CATALOG NUMBER: RM2260BU Luminaire: Class I, Division 2 fluorescent fixture with glass lens (4 foot, T-12. 60 Watt) tested 0 1237 1237 1237 1237 1237 s: 2 Philips 60 Watt (4 foot, T-12) F48T12CWHO ALTO Ballast: Advance T-12, 60 Watt, catalog number VEL-2S110 5 1227 1231 1229 1231 1227 117 15 1188 1194 1193 1194 1188 337 25 1100 1108 1111 1108 1100 511 Based on: 4,050 Lumens per 35 968 977 976 977 968 610 TOTAL LUMINAIRE EFFICIENCY = 39.6% ZONAL LUMEN SUMMARY 45 800 806 805 806 800 619 CIE Type Direct ZONE LUMENS % LAMP % FIXT. 55 591 593 594 593 591 529 Plane: 0 90 0-30 965 11.9 30.1 65 351 352 351 352 351 347 Spacing Criteria: 1.2 1.2 0-40 1574 19.4 49.1 75 122 116 106 116 122 127 0-60 2722 33.6 84.8 85 10 8 6 8 10 12 0-90 3208 39.6 100.0 90 0 0 0 0 0 90-180 0 0.0 0.0 0-180 3208 39.6 100.0 1110