DWDM-8C / DWDM-8C-MkII

Similar documents
ETH1000-SFP. User manual. Gigabit Ethernet Media Converter. Rev. A. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

DA-AES. AES distribution amplifier. User manual. Rev. 8

3GHD-EO-SFP. User manual. SD/HD/3G-SDI electrical to optical converter with SFP. Rev. A

DA-SDI-NRC. User manual. SDI Distribution Amplifier Non-Reclocking version. Rev. E

3GHD-EO-2-SFP. User manual. Dual SD/HD/3G-SDI electrical to optical converter with SFP. Rev. C

DAC-AES. DAC-AES Audio Converter. User manual. Rev. 7

HDSDI-CHO-2x1 HD-SDI-CHO-2x1-PB

3GHD-OE 3GHD-OE-2. User manual. Single and dual 3G-SDI optical to electrical converter. Rev. F

ADC-AES. ADC-AES Audio Converter card. User manual. Rev. 5

3GHD-EO-D15xx. User manual

LB-EO. User manual. L-BAND Electrical to Optical Converter. Rev. F. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

RS-422 Data Transceiver Supports CWDM

AD6464M / AD128128M. User manual

Dual HD-SDI Electrical to Optical Converter

Multi Rate Transponder and Converter for 1330 /1550nm and Coarse Wavelength Division Multiplexing. Flashlink User Manual

Analogue audio de-embedder

3G-IP-MUX-8-SFP. User manual. 8 channel bi-directional 3G/HD/SD Video over IP multiplexer/de-multiplexer. Rev. A

Analogue audio embedder

3GHD-CHO-2x4/2x3. User manual

A3232M / A6464M / A128128M A3232S / A6464S

AAV-HD-XMUX(-T/R)/ AAV-SD-XMUX(-T/R)

AAV-HD-DMUX(-R)/ AAV-SD-DMUX(-R)

SD-SDI LINE SYNCHRONIZER

SLX2-3GHD3232-CP Sublime X 2 hybrid router

AV-HD-XMUX (-T/R) / AV-SD-XMUX (-T/R)

3GHD256256L / SD256256L. User manual

FRS-3G-DUAL. User manual. Dual Frame Synchronizer for 3G/HD/SD-SDI. Rev. A (Preliminary)

The Art of Engineering

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module

SDI-TD-3GMX-5 / SDI-TD-3GDX-5 HD-TD-3GMX-2 / HD-TD-3GDX-2

PGM-HD-2x1-PB. User manual. HD/SD-SDI 2x1 Program Switch with Frame Synchronizer. Rev. B

AV-3G-XMUX User Manual

Optical Passives Optical Mux/Demuxes, Optical Splitters, Optical Switch, Optical Shelves, Sidecar Enclosures

Remote LightBar Series Datasheet

DATA SHEET. NEC's L-BAND 4W HIGH POWER SPDT SWITCH IC

DWDM. DATA SHEET DB4134-E Issue F Page 1 of 6

Agilent 81600B Tunable Laser Source Family

3M Mini D Ribbon (MDR) Cable Assembly

PSC UHF Log Periodic Antenna

EdiPower II Series. Features LED light engine High power operation Instant on Long lifetime. Copyright 2010 Edison Opto. All rights reserved.

Product Operation Manual

Medallion 7100 Series CATV Fiber Amplifier

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

UltraVista LC II HDMI 2x2 HDMI Video Controller/Splitter

ET-5050RTB-333W Datasheet

HDCVI Video Converter. User s Manual V1.0.0

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

Official Journal of the European Union L 82/3 DECISIONS COMMISSION

Headend Optics Platform (CH3000)

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Headend Optics Platform (CH3000)

Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

PLCC Lightbar FPC 3528 Series Datasheet

PLCC 2110 Lightbar Series IP20 Datasheet

25W 9xxnm Uncooled Multimode Laser Diode Module

PLCC Lightbar FPC 3528 Series Datasheet

User Manual AES-MUX. Multichannel digital audio to fibre.

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

Modular pulse operated latching relay 16 A

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

PLCC Lightbar Constant Current FPC Series Datasheet

OPTICAL DISTRIBUTION STATION -

PLCC Lightbar FPC 3528 Series Datasheet

opengear OPG-1L 50 MHz-2.3 GHz

SP02 Series Tape Feeder. Operator Guide. All rights reserved Revision 1 29 Feb D-E36

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

ACION 8000 Series. A8KFR1 1RU Forward Receiver

USER GUIDE MULTI-CHANNEL STEREO MIXER S MIX 4M2S UD

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

Slot in PC module VPC10-WP (for IFP50 series) Quick Start Guide

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

PL7330T / PL7330R16 RF Link High Power Input, 16dB Optical Budget 45Km nm or 70Km nm

PLCC 5050 Hunter Lightbar IP20 Datasheet

Tunable SFP+ DWDM 10G 80Km ZR SLSSD-10GE-ZR-T

Model :UVC-S100 (Universal Video Converter)

S MiX 2M2S UF. S MiX 2M2S F

Bell and Light System tm RF Remote Control

Table of Contents. Headend Optical Transport OmniStar Enhanced DFB Laser [AM-OMNI-ALM-*] file:////ncs-server-xp/temp/motorola CD 2001/frames.

Long Distance L-Band Fiber Optic Links

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

OpticalProducts. Illuminating Your Network. Testing the World s Networks

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

OmniStar GX2 Headend Optics Platform

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

LT1550 Laser Transmitter with Erbium Doped Fibre Amplifier

Model /29S RF Splitter

LONWORKS Fibre Optic Router

USER MANUAL. Elo Touch Solutions ET1517L and ET1717L Touchmonitors. SW Rev F

PLCC Lightbar Hunter FPC Series Datasheet

Lightbar Series. Typical Applications : Signage and Commercial Lighting Architectural features and sculptures

Intensity Modulator with Low Drive Voltage F10

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

Transcription:

8 channel 100GHz DWDM C-band multiplexer and demultiplexer with upgrade port User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com

Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion USA 1600 Emerson Avenue Oxnard, CA 93033, USA Toll free North America: (866) 515-0811 Outside North America: +1 (805) 247-8560 E-mail: support@nevion.com See http://www.nevion.com/support/ for service hours for customer support globally. Revision history Current revision of this document is the uppermost in the table below. Rev. Repl. Date Sign Change description C B 2015-12-03 OEH Adding information on MkII changes B 1 2015-06-10 MB Template update; DoC removed 1 0 2011-09-23 AA / 2012-05-18 JRW New template. 0-2007-08-29 OEH Initial version. nevion.com 2

Contents Revision history... 2 1 Product overview... 4 2 Specifications... 5 2.1 Optical specifications... 5 2.2 Channel plan... 5 3 Connections... 7 3.1 Mounting the DWDM-8... 7 3.2 1-8 channel system... 7 3.3 9-40 channel system... 8 General environmental requirements for Nevion equipment... 10 Product Warranty... 11 Appendix A Materials declaration and recycling information... 12 A.1 Materials declaration... 12 A.2 Recycling information... 12 nevion.com 3

1 Product overview The Flashlink DWDM-8C(-MkII) is a set of optical modules for multiplexing and demultiplexing 100GHz spaced DWDM (Dense Wavelength Division Multiplexed) signals. The modules are divided into multiplexers and de-multiplexers, which form a complimentary pair. There are a total of 5 different pairs, each with their own set of wavelengths and an upgrade port. By use of the upgrade port, up to 40 optical signals can be run over a single fiber. The units are passive and all-optical devices, requiring no power supply or control. Any number of channels can be used to transport signals in one direction with the rest of the channels transporting signals in the other direction. The units can be cascaded through the upgrade ports in any order. However, one end should be cascaded in opposite order compared to the other, for optimum performance. An additional filter pair called DWDM-8C-13-MkII is available for use with DWDM-8C-2- MkII, to fill out the C1551 passband when upgrading a CWDM-18 to have more than 18 available wavelengths (up to 33 channels available in total). Information about this, including connection diagrams, is available in the DWDM-8C-13-MkII user manual. Additionally, Nevion has a non-modular 40 channel DWDM filter for long-haul applications which require lower loss. The MkII version of all of Nevions passive optics are fully compliant with both the FR- 2RU-10 and the FR-202. Figure 1: DWDM-8C block diagram nevion.com 4

2 Specifications 2.1 Optical specifications Number of channels Up to 40 Available wavelengths See section 2.2 Connector SC/UPC Insertion loss (one matched pair, including 4.5dB max connectors) Insertion loss (common to upgrade) 0.8dB max Channel Spacing 100GHz Passband +- 15.0GHz Adjacent Channel Isolation 25dB min Non-Adjacent Channel Isolation 40dB min Directivity 45dB min Return loss 45dB min PDL 0.25dB max Operating Temperature 0 55 o C Storage Temperature -40 85 o C Optical Power 300mW max 2.2 Channel plan Channel plan (product suffix) 1 2 3 Channel (#) Center frequency (THz) Wavelength (nm) 20 192.0 1561.41 21 192.1 1560.61 22 192.2 1559.79 23 192.3 1558.98 24 192.4 1558.17 25 192.5 1557.36 26 192.6 1556.55 27 192.7 1555.75 28 192.8 1554.94 29 192.9 1554.13 30 193.0 1553.33 31 193.1 1552.52 32 193.2 1551.72 33 193.3 1550.92 34 193.4 1550.12 35 193.5 1549.32 36 193.6 1548.51 37 193.7 1547.72 38 193.8 1546.92 39 193.9 1546.12 40 194.0 1545.32 41 194.1 1544.53 42 194.2 1543.73 nevion.com 5

Channel plan (product suffix) 4 5 Channel (#) Center frequency (THz) Wavelength (nm) 43 194.3 1542.94 44 194.4 1542.14 45 194.5 1541.35 46 194.6 1540.56 47 194.7 1539.77 48 194.8 1538.98 49 194.9 1538.19 50 195.0 1537.40 51 195.1 1536.61 52 195.2 1535.82 53 195.3 1535.04 54 195.4 1534.25 55 195.5 1533.47 56 195.6 1532.68 57 195.7 1531.90 58 195.8 1531.12 59 195.9 1530.33 nevion.com 6

3 Connections 3.1 Mounting the DWDM-8(-MkII) The DWDM-8C must be mounted in a Flashlink subrack. For use in the FR-202, only the DWDM-8C-MkII should be used, although it is possible to modify the FR-202 to allow inserting a DWDM-8C. Contact the support department for information about this if necessary. Mounting is done from the rear of the subrack. Do not use force when inserting the DWDM-8C(-MkII), once the module s upper rail aligns with the card rail in the subrack, it should slide easily into place. Lock it with 4 M2.5x8mm screws. Figure 2: DWDM-8 mounted in a Flashlink subrack 3.2 1-8 channel system Connect each of the optical ports to the corresponding optical port on the receiver or transmitter that matches the signal type and wavelength. Care must be taken to stay within the power supply specification for the frame. Power supply requirements for each module are listed in that module s user manual. If the total power supply requirement for a frame exceeds the capabilities of the power supply mounted in that frame, some modules must be moved to a separate frame and power supply. Figure 3: Interconnection of an 8 channel system nevion.com 7

Figure 4: 8 channel filter connected to main fibre 3.3 9-40 channel system Each set of 8 channels must first be connected like described in Chapter 3.2, Figure 3. Next, the frames are interconnected, endpoint A should be opposite of endpoint B for optimum performance. For endpoint A, the common port of module 1A would typically be the common port of the whole system, connected to the outside world. The upgrade port of module 1 would connect to the common port of module 2A, and so on. For endpoint B, the common port of module 5B would connect to the outside world (and thus to common port of 1A), while the upgrade port of 5B would connect to the common port of 4B. Figure 5: Optimal interconnection of a 40 channel system nevion.com 8

This way, the insertion loss can be considered to be identical for all channels in a 40 channel system. If the system is set up in a different way, some channels will see less insertion loss, while others see more. This limits the optical budget. If the optical budget is not a limiting factor, the system can be connected in any way, since all modules come with an upgrade port. nevion.com 9

General environmental requirements for Nevion equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: - Operating room temperature C to 50 C range: - Operating relative humidity range: <90% (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: - Temperature range: -10 C to 60 C - Relative humidity range: <95% (non-condensing) nevion.com 10

Product Warranty The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Nevion, which are available on the company web site: www.nevion.com nevion.com 11

Appendix A Materials declaration and recycling information A.1 Materials declaration For product sold into China after 1st March 2007, we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products. In the first stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information. Toxic or hazardous substances and elements 組成名稱 Part Name 鉛 Lead (Pb) 汞 Mercury (Hg) 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr(VI)) 多溴联苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) DWDM-8C O O O O O O DWDM-8C-MkII O O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. This is indicated by the product marking: A.2 Recycling information Nevion provides assistance to customers and recyclers through our web site http://www.nevion.com/. Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require. Where it is not possible to return the product to Nevion or its agents for recycling, the following general information may be of assistance: Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. All major parts are marked or labeled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices. nevion.com 12