KEL 183 Cable entry frames

Similar documents
Product group 1. Product description. At a glance. Cable entry systems for entering pre-terminated cables

KEL 24 Cable entry frames

KVT Split cable glands

KVT Split cable glands

Cable entry systems ... p e r f e c t - i n n o v a t i v e - s m a r t

NEW. Datasheet. Field wiring Cabtite Easy Cable Entry System!

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Cable entry systems. perfect innovative smart. Cable entry systems

Control cabinet interface and cable entry systems

HARTING Ethernet cabling cables and connectors, 4 wire

EXPlora. Introduction

Flexible Cord. Inside this section

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

S020 fluorescent tube luminary

7 Lighting Technology

1.2 EUREKA Series... from page c.14

EXLUX ECOLUX 6480 Series

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

Cable and Pipe Entry Products Cable penetration by design

TWINTEC B Signal Circular Connectors

TYPE APPROVAL CERTIFICATE

Grounding-type plugs and sockets K Product information

Installation instructions Ex frames

MANUAL CABLE MARKING SYSTEM PMP-30 PUSH-IN CABLE MARKERS WITH HOLDERS

M23 RJ 45 M23 Profinet M16 (10pole)

EXLUX ECOLUX C-LUX 6480 Series


NEW NEW NEW. Page 137. Page 138. Page 128. Page 136. Page 134. Page 134 Page 139

Filters for Power Lines (Low Leakage Current)

AGRO. The Cable Glands.

TYPE APPROVAL CERTIFICATE

I Ex-protected connectors exlink I

TECHNICAL SPECIFICATION

Horn loudspeaker, Ex proof, short/long flare

Cable entry and cable holding systems Solutions for cable applications

Pendant Light Fitting IEC Series 6470/2

Installation Manual for New or Retrofit Installations

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

8 Installation Equipment

Roof-mounted Blue e+ cooling unit Integration solution VX25

RSCC. Load cells. Special features. Data sheet

Optical Distribution Box 300 Installation Guide. Version : R0.0

We are your competent partner for cable routing

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Flexibility and Safety. BERNSTEIN safety hinge switches

Optical Signal Devices. Free-standing Beacons

Fiber Optic Splice Closure GPJ Instruction Manual

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

FREE STANDING CABINETS - S SERIES

SPECTRUM. cordgrip connectors AMERICAN FITTINGS. SPEC-grade. Corporation 1/2 to 2. Made in the USA. Put a Little Color on Your Cords

Catalog. Industrial Plugs & Sockets The complete range

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Connecting cables NEBS, for sensors

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Customer-Owned Outside Plant

Bimetal Temperature Switch

ENC - LKE51 - L I B

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

3M Fiber Closures BPEO

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

2178-L/S Series Fiber Optic Splice Case with Gasket

Operating instructions

Gel-sealed in-line fiber optic closure

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Selection matrix for electronic pressure switches

Installation instructions Cable transit device Roxtec RS ES Ex

3M Distribution Box (DDB)

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

BUILT FOR WHAT MATTERS BRIDGEPORT TRANSITION FITTINGS CHANGING EVERYTHING. SEE THE DIFFERENCE ORANGE MAKES TM BPTFITTINGS.

J-Pro Cable Support System Let Panduit Support Your Cables

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

DKS 40: Incremental Encoder

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

3 Cleaning. 4 Technical data

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Best Friends General Trading FZE

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Signet 2250 Hydrostatic Level Sensor

Spiral Dπ - Light Type

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

WLB SERIES HID Lighting for Hose Down Applications

TECHNICAL INFORMATION

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Small Circular Connector. JN1/JN2 Series. Dust Cap

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Up to 85% higher Service Life due to efficient sealing method.

Transcription:

KEL 183 Cable entry frames Description Type Order.No. Inserts KT PU KT 183 KT large The new version of the split cable entry frame KEL 183 enables the user to route cables and tubes with a diameter up to 75 mm and to seal in accordance with IP 54. KEL 183 2 47200 2-1 For cables up to 34 mm the cable inserts KT large can be used. With the split cable inserts, pre-terminated cables can be routed. For cables up to 75 mm we have created new inserts KTMB for KEL 183 (see page 33). These are not split and have a defined port for pushing the cable through. KEL 183 5 47220 1 4 1 KEL 183 8 47240-8 1 Installation of cables up to 75 mm Inserts allow dynamic and flexible movement of rigid cables Retrofitting and maintenance can be carried out easily and quickly Specification Cut-out dimensions Polyamide IP 54 with gasket and correct selection of the cables - 40 C bis + 140 C (static) see page 124 125 KTMB Cable inserts for KEL 183 DT/ KT Cable inserts Page 33 Page 26 28 32

KTMB Inserts for KEL 183 Type Order.No. Clamping range PU grey KTMB-O 41410 Blind insert 1 KTMB-P 41415 34-44 mm 1 The inserts KTMB-P to KTMB-S are suitable for cable diameters up to 75 mm. These inserts can be used with the KEL 183 cable entry frames. These multi-range inserts are not split and have a defined port for pushing the cable through. The blind insert KTMB-O is completely closed. After cutting the membrane (cable diameter minus 10 mm) it can be used also as a multi diameter insert for cables up to 55 mm KTMB-Q 41420 44-54 mm 1 Spezification Brandklasse Schutzart Temperatur Eigenschaften Elastomer IP 54-40 C bis + 0 C (static) KTMB-R 41425 54-64 mm 1 KEL 183 Cable entry frames Page 32 KTMB-S 41430 64-75 mm 1 33

KT Inserts, large 41,5 42 Description Type Order No. Order No. Clamping range PU grey black ATG ATG 41253 41353 Adapter insert 10 The KT inserts large accept a wide range of cable diameters from 16 to 34 mm. They are used with the following cable entry frames: KEL - Page 6-13 KEL-FG - Page 14-15 KVT / KVT-W0 - Page 18-22 KEL 183 - Page 32 BTG BTG 41252 41352 Blind insert or 5-20 mm 10 ATG adapter inserts provide the possibility to hold a small KT insert to reduce the clamping range down to 2 mm. KT 28 KT 16 41216 41316 16-17 mm 10 KT 17 41217 41317 17-18 mm 10 KT 18 41218 41318 18-1 mm 10 Specification KT grey Elastomer - 40 C to+ 0 C (static) KT 1 4121 4131 1-20 mm 10 KT 20 41220 41320 20-21 mm 10 KT 21 41221 41321 21-22 mm 10 KT 22 41222 41322 22-23 mm 10 KT 23 41223 41323 23-24 mm 10 KT 24 41224 41324 24-25 mm 10 Specification KT black KT 25 41225 41325 25-26 mm 10 KT 26 41226 41326 26-27 mm 10 Elastomer UL-4 HB - 30 C to + 0 C (static) higher chemical resistance, UV-stabilized KT 27 41227 41327 27-28 mm 10 KT 28 41228 41328 28-2 mm 10 KT 2 4122 4132 2-30 mm 10 KT 30 41230 41330 30-32 mm 10 KT 32 41232 41332 32-33 mm 10 KT 34 41234 41334 33-34 mm 10 26

KEL - JUMBO Cable entry frames Description Type Order No. Dimension PU length width height The KEL-JUMBO cable entry system for installation of cables and conduits with a diameter up to 65 mm, especially suited for supply cables. KEL - JUMBO 1 42360 110 x 116 x 35 1 The innovative insert design enables dynamic and flexible movement. We recommend round cut-outs, which can be made using standard tools. Suggested cut-out: cable diameter + 15-20%. KEL - JUMBO 2 42350 200 x 116 x 35 1 Installation of cables up to 65 mm KTF-inserts allow dynamic and flexible movement Retrofitting and maintenance can be carried out easily and quickly Specification Cut-out dimensions Polyamide IP 54-40 C to + 140 C (static) round, cable diameter + 15% KTF Cable inserts KDR2 Split base plates MP Module plates Page 35 Page 102 103 Page 112 34

KTF Inserts for KEL-JUMBO KT large KTA Type Order No. Clamping range PU grey KTF 00 42371 Blind Insert 1 KTA 42370 Adapter Insert for KT large 1 The inserts range KTF are suitable for cable diameters up to 65 mm. Suitable KEL-JUMBO cable entry frames, see page 34. KTF 34 42376 33-36 mm 1 Comparativly small assembled cables with large inserts can be routed by using the adapter insert. KTF 38 4237 37-40 mm 1 KTF 42 42382 41-44 mm 1 Specifi cation KTF 46 42385 45-48 mm 1 KTF 50 42388 48-52 mm 1 Elastomer IP 54-40 C to + 0 C (static) KTF 54 4231 53-56 mm 1 KTF 58 4234 56-60 mm 1 KEL - JUMBO Cable entry frames KT large Page 34 Page 26 KTF 62 4237 61-65 mm 1 35

Cable entry inserts Type Order No. Thread External Clamping range PU metric dimension 25 3-17 42652 M 25 3 mm 3-17 mm 5 The KEL-DPF was developed particulary for routing supply cables into the switch cabinet. 32 6-24 42653 M 32 46 mm 6-24 mm 5 Due to the flexibility and unique pyramid shape, cable entry and positioning is much easier compared to using conventional cable glands. Cutting of DPF inserts: Cable diameter less 5 mm The corresponding diameters are marked on the insert 40 11-32 50 17-42 42654 M 40 54 mm 11-32 mm 5 42655 M 50 64 mm 17-42 mm 5 Assembly within seconds It is possible to install rigid cables at angles Suitable for standard or metric cut-outs Polyamide locknuts are included in the shipment Specification 63 23-55 42656 M 63 77 mm 23-55 mm 5 Thread length Cut-out dimensions Thread frame: Polyamide Pyramid: Elastomer IP 66-40 C to + 0 C (static) 14 mm metric standard sizes MP Module plates Page 112 55

KEL - JUMBO flex Cable entry inserts Description Type Order No. Clamping PU range 27-30 30-33 33-36 The KEL-JUMBO flex is a flexible cable entry system for standard cables with a diameter range from 27-68 mm. They are ideal for the routing supply cables into the switch cabinets. 36-3 3-43 43-46 46-48 88 70 0,5,5 62 62,5 KEL - JUMBO flex 27-48 42614 27-48 mm 1 Cutting of KEL-JUMBO flex inserts: Cable diameter less 5 mm The corresponding diameters are marked on the insert 70 88 6, (4x) Assembly within seconds Inserts allow dynamic and flexible movement of rigid cables Small installation dimensions (88 x 88 mm) 47-50 50-53 53-56 56-60 60-63 63-66 66-68 62 62,5 KEL - JUMBO flex 47-68 42616 47-68 mm 1,5 Specifi cation 88 70 0,5 Cut-out dimensions 70 88 Frame: Polyamide Inserts: Elastomer IP 54-40 C to + 0 C (static) round, ø-cable + 20% 6, (4x) MP Module plates BP Blind plates Page 112 Page 114 56

KEL - ULTRA flex Cable entry inserts Type Order No. Sealing range PU KEL-ULTRA fl ex 1 incl. Fixing screws KEL-ULTRA fl ex 2 incl. Fixing screws 42630 25 - max. 0 mm cable diameter 1 42631 75 - max. 115 mm cable diameter 1 The product line KEL-ULTRA flex is designed as a cable entry system for power supply cables or any cable or conduit that is difficult to manage. The KEL-ULTRA flex comes in two sizes and is good for routing and sealing cables and conduits with a diameter from 25 to 115 mm. Inserting large, thick cables is easier than using standard cable glands due to the high flexibility of the KEL-Ultra Flex elastomer pyramide. After inserting the cable or conduit, the KEL-ULTRA flex is quickly and easily mounted with the metal ring and screws. The metal ring enables a circular fixing and sealing of the insert at the enclosure wall. The metal ring is supplied with each KEL-ULTRA flex. Assembly within seconds Inserts allow dynamic and flexible movement of rigid cables IP66 Specification Cut-out dimension Insert: Elastomer Fixing metal ring: Steel, zinc-plated Blind plate: Steel, zinc-plated IP 66 (when fastened with 8 screws) - 40 C to + 0 C (static) ø-cable + 30%, max. ø 140mm 57 MP Module plates BP Blind plate Page 112 Page 115