FLOMAT Electromagnetic Insertion Flowmeter

Similar documents
FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

MT03A Electronic converter for flow rate transmitters

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

Electronic converter for level transmitters MT03L Instructions manual

800 Displaying Series Flowmeter

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Electronic converter for flowmeters MT03F Instructions manual

Mechanical flow switch for On/Off control

Solenoid valves VZWD, directly actuated

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Wall-/Pipe-Mount Level Indicator

Capacitance Level Measurement Electronic insert FEC 12

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

Modular Lube Lubrication Systems System Controls

PROPORTIONAL VALVES Sentronic plus

Level Measurement silometer FMC 420, FMC 423

Henkel Installation Handbook LINEGUARD 2001

Solenoid valves VZWD, directly actuated

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

MICROPROCESSOR CALCULATION MODULE - S2000

Process Transmitter RMA 422

TFRH Hygienic RTD temperature sensor. CombiTemp TM

LAUREL ELECTRONICS, INC.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

FIELD MOUNTED RATE TOTALISER MODEL 202D

02/11/2015

Pressure transmitter COMPACT IO-Link,

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Standard RS232 RS ma

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Inductive sensor NI3-EG08K-Y1-H1341

DCP100 Digital Control Programmer Specifications

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

High performance circuit breakers

Single Point Flow Monitor SW118 SW119

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Flow Measurement SITRANS F M

multi-function meters

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Operating instructions Electronic preset counter Type series 717

General Specifications

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI10-M18-Y1X-H1141

Capacitance Limit Detection nivotester FTC 420/421/422

DATA SHEET ML210 ML210_IT_EN_DS017REV12_IS

AF-300 E11 Adjustable Frequency Drive

SPECIFICATION NO NOTE

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

2291 Guided Wave Radar Level Transmitter

ELE C TRO MAG N E T I C FLO W M E T E RS

dissolved oxygen transmitter

Table of contents 1. INTRODUCTION GENERAL CONTENTS OF PACKAGE GENERAL USE OF THE EQUFLOW 6100 D/A CONVERTER STORAGE..

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

GRUNDFOS alldos product information. The solution for complex dosing tasks

LEVIFLOW Ultrasonic Technology Single-Use High Precision Flowmeters

SPOOL PIECE ultrasonic FLOWMETER

TFR5 Room or outdoor temperature sensor. CombiTemp TM

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Lt DELTA USA, Inc

Dissolved Oxygen Transmitter

Section C Recorders. DPR mm Digital Strip Chart Recorder

Multifunction devices

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

263 Series LED Bargraph Indicator and Controllers

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

LEVIFLOW Ultrasonic Technology Single-Use High Precision Flowmeters

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

High Performance Outdoor Test Translators

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

LONWORKS Fibre Optic Converter

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Digital Flow Switch for Water

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

COMPONENTS & COMPONENTS & ACCESSORIES

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Transcription:

LOMAT Electromagnetic Insertion lowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction or use in large diameter pipes or open channels as an economical solution for liquid metering. low rate for liquids with electrical conductivity better than 20 µs/cm, for example. - Water treatmernt - Sewage treatment - Acid, neutral or alkaline solutions - Chemical and pharmaceutical products Suitable for use at low and medium temperatures. The body is constructed in stainless steel EN 1.4404 (SS 316L), on request available in PVD wetted parts with electrodes in Hastelloy C, Ziorconium, Titanium. Benefits Readings are independent of density, temperature, viscosity and pressure Alternating magnetic field for metering avoids electrolysis Absence of obstructing elements gives low pressure loss and will allow the pass of solids Can be mounted in any position, provided that the pipe is always full Low power consumption Good stability with temperature and age No moving parts provides zero maintenance Can be installed with short straight pipe sections (10DN / 5DN) Good chemical resistance of construction materials Metering Body Technical Data Pressure rating: PN16 Liquid Temperature range: PVD Head -20 O C...+130 O C Electrodes: Standard Hastelloy C Special Order Titanium, Zirconium ield coil current: 130 ma 6,25 / 7,5 Hz Liquid Conductivity: >20 µs / cm Accuracy: + 3,5% NOTE: or temperatures above 70 O C it may be necessary to separate the control unit from the metering body, depending on air temperature and ventilation of the control unit.

Measurement Principle The lomat electromagnetic insertion flowmeter consists of a sensor which generates a magnetic field in the liquid to be measured. The conductive liquids, as they flow through the magnetic field (5), generate a voltage E 6 (6) between the electrodes (3) which is proportional to the liquid velocity (V 7 ). The generated voltage is processed by the microprocessor electronic circuit to give outputs of ma or Hz proportional to the flow rate Q(8). Q 8 = K. V 7. E 6 (K=factor of sensor) Sensor Construction 01 Electronics housing Aluminium/Polycarbonate 02 Union EN 1.4404 (SS 316L) 03 lange/bsp nut EN 1.4404 (SS 316L) 04 Body EN 1.4404 (SS 316L) 05 Mounting Insert EN 1.4404 (SS 316L) 06 ield Coil 07 Head PVD 08 Electrodes Hastelloy C 09 Gasket NBR Installation Install with a straight section of minimum 10DN length before and 5DN after The pipe should always be full - install in a rising section DN80... DN2000 Valves should be mounted after the sensor to maintain a full pipe Pumps should be installed before the sensor DN40... DN65 * Correct mounting to avoid air pockets and dirt deposits on the electrodes in blue zone. 2

Insert (Dimensions in mm) DN40... DN2000 Mounting LOMAT 1 DN40 = 110 DN50 = 115 DN65 = 122,5 16 (H) ø48,26 x 2,77 DN40 = 135 DN50 = 140 DN65 = 145 S C ØDN ØDe fig. 2 DN80... DN2000 fig. 1 LOMAT 2 Dimensions in mm DN (H) De* S C 1 40 48,3 2,6 15 50 60,3 2,9 15 65 76,1 2,9 15 80 86 88,9 3,2 15 100 86 114,3 3,6 15 125 82 139,7 4,0 19 150 78 168,3 4,5 22 200 69 219,1 5,9 30 250 61 273,1 6,3 38 300 46 316 7,5 45 350 41 255,6 8 52 400 33 41,9 10 80 500 123,5 521 11,5 75 600 111 632 12 90 700 96 724 12 105 800 81 827 13,5 120 900 66 928 14 135 1000 51 1032 16 150 1200 180 1236 18 180 1400 150 1136 18 210 1600 120 1640 20 240 1800 90 1844 22 270 2000 60 2060 25 300 fig. 3 LOMAT 204 mounted with ring DN80... DN2000 * Approximate, depending on the pressure and pipe material 1 C is the necessary distance that the sensor (not the insert) should be inserted into the pipe (fig. 1) LOMAT 1RS (Remote electronics) fig. 4 DN80... DN2000 LOMAT 103 mounted with body ring for PVC/PE fig. 6 fig. 5 DN80... DN300 3

Dimensions Sensor with Compact Electronics LOMAT 1/XT5 LOMAT 2/XT5 LOMAT 1/MX LOMAT 2/MX 107 107 157 157 e/c 75 A A 24 9 227 198 227 198 214 184 214 184 ø85 A e/c 75 A ø85 Dimensions in mm DN A 1 Sensor Compact Senso Sensor Length with 1RS or 2RS XT5 / MX 40 50 332/151 242 65 80 100 125 150 105 332/289 242 200 250 300 350 400 500 600 700 800 210 437/124 347 900 1000 1200 1400 1600 360 587/574 497 1800 2000 Sensor with Remote Electronic 1RS A 137 108 e/c 75 A 137 108 2RS ø85 1 is the minimum dimension necessary to remove 4

Metering body selection The diagram shows the relation between the liquid speed and the flow rate for different body sizes. The metering body diameter should be chosen to obtain a maximum normal working liquid velocity of about 3-4 m/s. The minimum working liquid velocity should not be below 0.5 m/s. A recommended working liquid velocity is between 1 and 3 m/s. l/s 20.000 10.000 5.000 l/min m 3 /h Liquid Velocity m/s 160.000 0,2 100.000,3,4 0,5,6,7,8,9 1 2 3 4 5 6 7 8 910 DN 2000 DN 1800 DN 1600 100.000 50.000 DN 1400 DN 1200 50.000 20.000 20.000 10.000 low rate table DN 1000 DN 900 DN 800 DN 700 DN 600 When the liquid has solids in suspension, it is better to work between 3 and 5 m/s to avoid sedimentation in the pipe and metering body. 1.000 500 10.000 5.000 5.000 2.000 DN 500 DN 400 DN 350 DN 300 DN 250 2.000 1.000 DN 200 100 1.000 500 500 DN 150 DN 125 DN 100 50 200 DN 80 100 DN 65 DN 50 100 50 DN 40 10 50 5 20 10 10 5 1 5 2 l/s 2 l/min 1 0,2 m 3 /h,3,4 0,5,6,7,8,9 1 2 3 4 5 6 7 8 9 10 Liquid Velocity m/s 5

Electronic Control Units Different models of electronic control units are available to comply with the options of flow indication, maximum/minimum flow rate controls, analog outputs, pulse outputs. All are compatible with the different lomat sensor models. mv Cycle Signal voltage or compact mounting directly on the sensor Series MX, with local indication, signal, ma and pulse outputs 0 Time or wall and pipe bracket mounting Series MX (Local Indication) - M*... T* Series MX / M* and MX /T* *M = wall mounting *T = pipe mounting mv A = 20 ms Measuring time Electronic Technical Data Series MX (Compact) and Series MX-M, MX-T (Separated) Painted coated injected aluminium housing. IP 67 degree of protection Programming via front tactile pushbuttons Totalising and partial volume counters Programmable batching volume with remote input for starting Magnetic field: 6.25 Hz square wave for 50 Hz mains 7.5 Hz square wave for 60 Hz mains Mains supply: 12 V, 24 V, 110 V, 120 V, 220 V, 240 V ac, + 10%, 50 o 60 Hz 24 Vdc (others on demand) Power consumption: <10 VA Min. lowrate cut off: Programmable Measuring range: 0...10 m/s Display: 16 character x 2 lines LCD 6 languages to be selected. Program for auto-edition of other languages lowrate indication: User programmable measuring units Analog output: 4...20 ma programmable Programmable pulse output mode: lowrate x Pulses/unit volume < 2 pulses/s Programmable frequency output mode: 10..1000 Hz Remote Version Mounting (Electronics) MX/M (WALL Mounting) 162 260 204 94 110 Logic outputs: Two programmable outputs for flowrate alarms, empty pipe detection, flow direction or batching Adaptive flowrate filter: Integration time programmable 0.1... 25.5 seconds ilter reset window programmable Linearity: 0.1% Zero drift: 0.05% Temperature drift: 0.015% / o C Working ambient temperature range: -10...+60 o C MX/M (PIPE Mounting) 162 285 204 94 110 MX Compact 342 342 ø130 ø130 90 140 190 ø8 60 85 ø50 6

Series XT5, Electronic Control Units Technical eatures Power supply: 230, 240, 115, 24 Vac 50/60 Hz 24 VDC Power consumption: < 5 VA Analog output: 4-20 ma. Active or passive Pulse output: Opto isolated V max.: 30 Vdc. I max: 30 ma Maximum frequency in P/U mode: 6,25 Hz Maximum frequency in Hz mode: 10000 Hz Maximum frequency in Hz mode: 0,04 Hz Optional. V max: 240 Vac / 350 Vdc. I max: 100 ma Maximum frequency in P/U mode: 6,25 Hz Maximum frequency in Hz mode: 75 Hz Totaliser: Nº of digits:7 (2 decimal points)** Digit size: 8 mm Button reset low indicator: Nº of digits 4 (up to 2 decimal point Configuration)** Digit size 5 mm ** When 4 digit counter reaches 10000, 1 decimal point is automatically eliminated. When 5 digit counter reaches 10000, the other decimal point is eliminated. In accordance with Directive 73/23/CEE Low voltage In accordance with Directive 89/336/CEE electromagnetic compatibility XT5 (Compact model) (202) 107 XT5/M (Wall Mounting) 147 198 118 57 61 General eatures Protection level: IP67 Ambient temperature range: 0... +60 O C Electrical eatures referring to analog loop and Communications Reception Impedance: Rx>8,5 M Ω Cx<200p Models: XT5 compact model XT5/M...T Wall or Pipe mounted XT5H compact model with HART communication XT5HM Wall or Pipe mounted with HART communication HART Communication The XT5H converter has a MODEM for HART communication. You will find all the features regarding HART communication in the corresponding document ield Device Specification Sumary of main communication features Manufacturer, Model and revision Tecfluid S.A., XT5 converter, Rev.0 Type of apparatus Transmitter HART protocol revision 6.0 Device description available No Number and type of sensors 1, exterior Number and type of actuators 0 Number and type of auxiliary host signals 1, 4-20 ma Number of Device variables 2 Number of Dynamic variables 1 Dynamic Mappables variables No Number of Common practice commands 13 Number of Device specifics commands 8 Additional Device Status Bits 17 Alternative function Modes? No Burts Mode? No Write Protection? Yes R3,25 120 107 XT5 Compact R6,5 80 24 11 120 11 24 144 XT5 Wall & Pipe XT5/M (Pipe Mounting) 57 (118) 61 57 (118) 61 11 11 190 ø50...80 7

LOMAT-TAP The LOMAT-TAP Series is an useful complement for the lomat sensors in some type of installations. The key features of the product are: lomat sensors can be inserted or removed under pressure (pipe full of liquid). Designed for obtaining flow measurement in different points of a distribution network with one only lomat sensor. Maintenance of lomat sensors without interruption of the flow. Minimum lenght for dismounting Lenght in mm DN max. A B C Total 600 385 720 140 1245 1200 480 830 140 1450 2000 588 960 140 1688 NOTE: the M-TAP accesory must be installed to the main pipe as an pipe as an insert pipe as an adaptor and it is a part of the complete system LOMAT-TAP. O 150 260 12 of DN 20 125 65 50 O 60,3 20 125 65 B A C 80 40 o C= 15% of DN 210 M-TAP LOMAT-TAP We are at your service, please consult us. TECLUID develops and manufactures instruments for gases and liquids, using the most advanced techniques. Request information by telephone nº: +34 93 372 45 11 Ref. LOMAT-10/05 P-3477 C/. Narcís Monturiol, 33-08960 SANT JUST DESVERN (BARCELONA) International: Telephone. +34 93 372 45 11 - ax +34 93 473 44 49 www.tecfluid.com - e-mail: tecfluid@tecfluid.com The technical data in this pamphlet is subject to modification without notification, if the technical innovations in the product or manufacturing processes so require.