PRODUCTION SPECS PACKET

Similar documents
PRODUCTION SPECS PACKET

PRODUCTION SPECS PACKET

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Paramount Theatre Production Recap

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Kenny Rogers Productions, Inc Production Requirements Indoor and Outdoor and Small Venue Performances

Meadow Brook Music Festival 3554 Walton Blvd Rochester Hills, MI Tech Pack

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

Technical Information

Technical Specifications

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

7774 Sashabaw Road Clarkston, Michigan 48348

Technical Specifications. Taylor Little Theater

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Sandusky State Theatre Technical Specifications

Sioux Falls Arena. I:\AD\001\H01\H01035.Docx Page 1 of 5

TECHNICAL INFORMATION DRIVING DIRECTIONS

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Dinkelspiel Auditorium - Technical Specifications

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Performing Arts Theatre

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Information

Ralph Engelstad Arena. PROMOTER S GUIDE Technical Facility Information. REA Technical Facility Information Updated 7/28/14

FOX THEATRE ST. LOUIS

UTC McKenzie Arena Technical Pack

Ordway for the Performing Arts Concert Hall Technical Information

Technical Rider. Ryan McFarling Illusionist. General Stage Requirements

JERWOOD VANBRUGH THEATRE

ADRIAN PHILLIPS BALLROOM INFORMATION AND SPECS

DRESSING ROOMS. - 1x Direct Dial 1x Ethernet Hardline SCREENING ROOM 47 x x Direct Dial Wireless Internet

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

Laura Turner Hall Overview. Sound System Overview

2016 Building and Production Specifications

Dunfield Theatre Cambridge

Meadow Brook Music Festival 3554 Walton Blvd Rochester Hills, MI Tech Pack

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

Quick-Advance Fact Sheet

Theatre Technical Specifications

Production Advance Information

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

USE OF JOHN M. GREENE HALL

Joyce Theater International Center for Dance Preliminary Program Requirements

Marjorie S. Deane Little Theater

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

Technical Specification

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Facility Information

TECHNICAL INFORMATION

Downtown Arts Center Tech Packet. General Information

Technical Specification Pavilion Dance

New Theatre Royal Lincoln Technical Information

Contents. 1. Contacts. 2. Directions & Transport Links 2.1. Address 2.2. Local Map & Directions 2.3. Public Transport

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Matt Dann Cultural Centre

SHUBERT THEATER 247 College Street, New Haven, CT

THE STREET THEATRE. Technical Specifications

Hollywood s historic jewel. -Billboard Magazine

The Lantern Technical Information

Producer of Event: Person Signing Agreement: Title: Nonprofit Corporation (Tax ID: ) FLC Department FLC Student Organization Other (Tax ID: )

GENERAL FACILITY INFORMATION - KANBAR HALL (REVISED JULY 2016)

Marist Auditorium. Facility Guide

Segerstrom Hall Capacity: Aesthetics: Patron accommodations: Box office: Technical specifications: Artist Accommodations: Center presentations:

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Technical Specifications and Inventory Spring 2018

Technical Services and Specification

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

PRODUCTION INFORMATION

VENUE PERFORMANCE FLOW March 15-17, 2018 Indianapolis, IN

Dr. Fred Speckeen Theatre. Information and Technical Specifications

The Breen Center for the Performing Arts Saint Ignatius High School

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

IDEAL BAR. General information Technical specifications Production information

Peacock Theatre Welcome to Peacock Theatre Dimensions Audio Visual Features Capacity Space Theatre Style Reception Style Cabaret Style Boardroom

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Technical Specifications

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

The Haymarket Basingstoke Technical Specifications

Scheme MOT Facility Improvements

The Cynthia Woods Mitchell Pavilion Frequently Asked Questions

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

BRAMALL INTRODUCING THE. Venue hire for classical & pop music, spoken word & comedy

Production Manager Shawn Dealey

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Lighthouse Theatre Technical Specification

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Concert Hall Technical Specifications

COURTYARD!!!!! THEATRE

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

TOURING RIDER Where Magic & Motion Meet!

Barney Simon Theatre Technical Specifications

Loading Dock / Van & Trailer / Bus Parking Same address. Pull to the back of the building to access loading docks and production lot.

Patriots Theater at the War Memorial Technical Data

Owensboro Sportscenter Facilities Guide

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Transcription:

PRODUCTION SPECS PACKET ADDRESS: Merriweather Post Pavilion 10475 Little Patuxent Parkway Columbia, Maryland 21044 Venue Phone: 410-415-5550 Venue Fax: 410-415-5560 Web Site: www.merriweathermusic.com CONTACTS: Promoter Rep & Production Manager: Brad Canfield brad@930.com Office: 410-715-5550 / Cell: 301-520-9603 Venue Director & Settlement: Merchandise: Dressing Rooms: Catering: Jean Parker jeanp@930.com Office: 410-715-5550 / Cell: 443-904-5113 Brian Nanson Franklin Serivces fatswag@juno.com Home: 410-655-3757 / Cell: 301-442-6866 Tina May tina@930.com Cell: 202-365-2374 Susanne Howell Eat to the Beat susanne.howell@eattothebeat.com Cell: 917-455-7622 Venue Ground Transportation: Victor Rivkin VJRivkin@aol.com Cell: 410-707-2966 Car Service: Kelby Enterline Choice Limousine Phone: 703-929-2462

CONTACTS Continued: Hotels: The Sheraton 10207 Wincopin Circle, Columbia, MD 21044 410-730-3900 Hilton Garden Inn 8241 Snowden River Parkway, Columbia, MD 21045 410-750-3700 Audio: Mike Scarfe MHA Audio Cell: 301-733-9337 Lighting: Instrument Rental: Instrument Sales: Len Applefeld Cell: 443-375-7004 Michael Toperzer Drums Unlimited Rentals Office: 301-982-3428 Washington Music Office: 301-946-2300 THE MERRIWEATHER DIFFERENCE: INTEGRATED HOUSE LIGHTS Merriweather has 85 LED houselights with a control portal located at Front of House. Many shows are choosing to sync the show LED lights to a gentle wash in all seating areas. This also gives you full control of house from FOH. When your stage LEDs go red on stage, well, the aisle lights, the pavilion ceiling and even the large trees on the back of the lawn can be the exact same red to truly make the audience feel like part of the show. IN-HOUSE VIDEO Merriweather has 5 LED video screens in 1080i HD 16:9, 59.94 frame rate. We will need an HDSDI feed from you if we are to feed our screens from your content. Merriweather has a full HD Studio with up to 10 HD cameras and all related gear. We are here to make your artist look good from any vantage point in the venue! Merriweather is happy to provide a Blu-Ray or HD video file of the night s performance. Please just let us know your video needs during the advance and we will make it happen. ARTIST LOUNGE Merriweather has an area located backstage with hammocks, wifi, lots of large trees, and of course the massage tent, where Merriweather offers complimentary massage therapy for all artists and crew every show from 3:00 pm until 9:00 pm. BIODIESEL Biodiesel is available for your fueling needs, via Baltimore Biodiesel. A B20 blend is stocked on site at Merriweather. Check website for current per gallon cost and fuel availability: www.baltimorebiodiesel.org. A valid credit card is all that is necessary to become a fueling member of the cooperative. You may choose to pay a one time member upcharge per gallon if you forgo the fueling member option. Pay at the pump and fill er up!

COMFORTABLE STAY Backstage at Merriweather, you ll find many things to make sure your date is excellent: large bath towels, a dedicated 50 mbps internet connection and Eat to the Beat catering, all the way from London. But what makes your date special is Merriweather s highly trained and very experienced backstage staff. HISTORY Merriweather opened in 1967. It has hosted Jimi Hendrix and Janis Joplin; Led Zeppelin opened up for The Who here; Jackson Browne recorded some of Running on Empty Live at Merriweather, and on and on. The pavilion is now operating in its sixth decade and continues to be a special venue BACK PHONE NUMBERS: MAIN VENUE NUMBER: 410-715-5550 Location/Name Extension Direct Dial Production 1 250 410-715-6770 Production 2 251 410-715-9848 Production 3 252 410-715-9430 Production 4 253 410-715-6747 Headliner Dressing Room 255 410-715-6750 Support Dressing Room 256 410-715-6730

: Material: Height: Width: Depth: Grid Height: Loading Dock Door: Loading Dock: Shore Power: Stage Left Power: Stage Right Power: Spot Lights: Rigging: Risers: Soft Goods: Lawn Delay: Sound Mix: Video: Gates: Dressing Rooms: Wood decking, 48 inset turntable stage for festivals or available for non-festival shows. Please request. 4 4 off the floor 82 feet wide 60 feet deep 62 to the grid and rigging points available over the entire grid on 3 centers. Is a rolling style 24 feet wide and 12 feet tall 6 bays with lights and a working area of 30 feet wide by 75 feet long Is located on the loading dock and can accommodate 3 buses 3 Phase, 400 Amp company switch 3 Phase, 200 Amp company switch 3 Phase, 200 Amp company switch 3 Phase, 400 Amp company switch 3 Phase, 400 Amp company switch 3 Phase, 200 Amp company switch 3 Phase, 200 Amp company switch 2 each (1.5K) Troopers with a 60 throw over audience dead center 2 each (2K) Xenon Super Troopers from 110 rear of the house See attached rigging plot Thirteen (13) various heights of configurable 4 x 8 rolling risers are available Black rear traveler and 8 black legs Requires balanced line level feed from FOH. Speakers system consists of: Five (5) arrays of four (4) Martin Audio W8LC weatherized line-array cabinets powered by Powersoft amplification and XTA control. Can be controlled via tablet. The mix area is located 95 from the stage and measures 13 x 15. We do have the ability to expand the sound mix as needed. Two 12 16 HD LED screens are hung stage left and stage right under the pavilion. One 15 20 HD LED center screen for the lawn is located on the roof with two additional 12 16 HD LED screens on each side of the roof. Our in-house video studio is HD with switching facilities for up to a 10-camera shoot. Content runs at 1920x1080i with a 59.94 frame rate. Open 1 1/2 hours prior to showtime There are 10 fully furnished dressing rooms with full bathrooms. There is a production office and a management office with a full restroom.

DIRECTIONS TO BACK: From Baltimore (and areas north): Take Beltway I-695 to Interstate 70 West to Route 29 South. Follow Route 29 approximately five miles. Turn right at South Entrance Road and continue to first light. Make a left at the light onto Little Patuxent Parkway. Continue through the next light and make the next possible left crossing over the other side of Little Patuxent Parkway. (There is a handicapped sign.? Follow the path through Symphony Woods, making a left into the handicapped parking lot to the backstage area loading dock. From southern Baltimore and Baltimore City: Take Interstate 95 South to Route 100 West towards Ellicott City. Route 100 West will end at Route 29 where you go South. Turn right at South Entrance Road and continue to the first light. Make a left at the light onto Little Patuxent Parkway. Continue through the next light and make the next possible left crossing over the other side of Little Patuxent Parkway. (There is a handicapped sign.) Follow the path through Symphony Woods, making a left into the handicapped parking lot to the backstage area loading dock. From Washington (and areas south): Take I-495 to 95 North towards Baltimore to Route 32 West towards Columbia. Continue on Route 32 (DO NOT take the Broken Land Parkway exit you see here!!) to Route 29 North towards Columbia. From Rt. 29 North, exit onto Broken Land Parkway (Exit 18B) following signs to Merriweather. Proceed to the second traffic light and turn right onto Little Patuxent Parkway. 200 Yards down Little Patuxent you will make the first right at Handicapped Parking Road. (There is a handicapped parking sign.) Make a left into the Handicapped parking lot at the bottom of the hill. Go through Handicapped parking to the loading dock area. From Ohio/Pittsburgh (and areas west): Take I-70 heading east toward Baltimore. Take Route 29 South toward Columbia. Follow Route 29 approximately five miles. Turn right at South Entrance Road and continue to first light. Make a left at the light onto Little Patuxent Parkway. Continue through the next light and make the next possible left crossing over the other side of Little Patuxent Parkway. (There is a handicapped sign.) Follow the path through Symphony Woods, making a left into the handicapped parking lot to the backstage area loading dock. If lost, please call 410-715-5550 or 301-520-9603. We will be your lighthouse and guide you safely into port (figuratively speaking).

SITE MAP

PAVILION SEATING VIEWPOINT: Standing on the stage looking at the audience i fright LOGE SEATING RIGHT CENTER SEATING SPOTS i i SPOTS i f LAWN SEATING g MIX LOCATION CENTER SEATING ORCHESTRA PIT LEFT LOGE SEATING LEFT CENTER SEATING g

PAVILION SEATING - LOGE AREAS VIEWPOINT: Standing on the stage looking at the audience RIGHT LOGE SEATING LEFT LOGE SEATING

VIEWPOINT: Sitting in the audience looking at the stage HEIGHT FROM FLOOR = 4 4 CEILING GRID HEIGHT FROM FLOOR = 62 RIGHT FLY GALLEY 48 HIGH FROM LEFT FLY GALLEY 48 HIGH FROM f 82 WIDE h 4 2 HIGH i h 60 ideep 48 INSET TURNTABLE g

LOADING DOCK VIEW

BACK Overview LOADING DOCK PRODUCTION OFFICES & DRESSING ROOMS

BACK Floor 1 TO SEATING 46'-11 3/4" PRODUCTION 24'-10 3/4" DRESSING DRESSING LOADING DOCK TOILET DRESSING VIDEO IT ELEC HAND DRESSING LAUNDRY WOMEN JAN MEN KITCHEN DINING LOBBY EXIT ARTIST SUITE SCREENED PORCH TO ARTIST LOUNGE

BACK Floor 2 TO SEATING VIP ROOM & BALCONY IMP ROOM & BALCONY DECK PROMOTER S ROOM & BALCONY ELEC DRESSING CONFERENCE DRESSING DRESSING DRESSING DRESSING SHOWER ROOM STORAGE MULTI-PURPOSE LOBBY BELOW OFFICE TO LOADING DOCK BALCONY BALCONY

CO SW EMERGENCY BYPASS DETECTOR LCD LEVEL SH1 SH12 SH1 SH2 SH3 SH4 SH5 SH6 SH7 SH8 SH9 SH10 SH11 SH12 EX.1 EX.2 EX.3 EX.4 L K J CO SW CO SW CO SW 94'-11 3/4" WIDE FLOOR OUTLET BOX 130 MBP MBP CO SW CO SW CO SW H MBP G TO LOADING DOCK 60'-5 1/4" RADIUS 24'-0" FLOOR OUTLET BOX TURNTABLE F TO BACK OF HOUSE MOTOR PIT COVER FLOOR OUTLET BOX E TO BACK OF HOUSE TO BACK ELECTRICAL RM

FLY GALLEY SH1 SH12 SH1 SH2 SH3 SH4 SH5 SH6 SH7 SH8 SH9 SH10 SH11 SH12 EX.1 EX.2 EX.3 EX.4 L K J METAL STAIR TO FLY GALLERY/RIGGING PLATFORM METAL SPIRAL STAIR TO FLY GALLERY/RIGGING PLATFORM DN UP 130 H G FLY GALLERY FLOOR FLY GALLERY FLOOR F E

RIGGING HIGH STEEL 12'-1 3/4" 10'-3" (8) EQUAL SPACES 10'-3" 12'-1 3/4" 77'-3" POST UP W24x55 W24x55 W24x55 W24x55 W24x55 W24x55 W24x55 W24x55 W24x55 W24x55 W24x55 W24x55 (+71'-11") (+71'-11") (+71'-11") (+71'-11") (+71'-11") (+71'-11") (+71'-11") (+71'-11") (+71'-11") (+71'-11") (+71'-11") (+71'-11") STEEL TRUSS (SEE S-107) 19'-7" 6'-9" 12'-10" 19'-7" 9'-9 1/2" 9'-9 1/2" 9'-9 1/2" 9'-9 1/2" 9'-9 1/2" HANGER DN. HANGER DN. & POST UP HANGER DN. HANGER DN. & POST UP HANGER DN. W21x44 W21x44 W30x90 11'-0 1/2" W21x44 CANT. HSS10x10x3/8 HANGER W16x26 W33x118 CANT. W33x130 CANT. W33x130 CANT. W33x130 CANT. L3x3x1/4 X-BRACE, (TYP) L3x3x1/4 X-BRACE, (TYP) L3x3x1/4 X-BRACE, (TYP) L3x3x1/4 X-BRACE, (TYP) L3x3x1/4 X-BRACE, (TYP) 3/4"x10" STL. ~P HANGERS @ 9'-9 1/2"o/c SEE D/S303 DETAIL (TYP) W33x130 CANT. POST UP, SEE ROOF FRAMING PLAN, (TYP) @ COL. LINES H & F W33x130 CANT. W33x130 CANT. W33x130 CANT. HSS10x10x3/8 HANGER W33x118 CANT. W30x90 W16x26 W21x44 CANT. W21x44 11'-0 1/2" W21x44 9'-9 1/2" W30x90 W30x90 W30x90 ACCESS LADDER, SEE ARCH. X-BRACE, SEE ELEVATIONS (TYP.) SUB-ROOF FRAMING PLAN SCALE: 1/8" = 1'-0" SUB-ROOF FRAMING PLAN NOTES: 1. 2. TOP OF STEEL ELEVATION = (+71'-7") AND IS IN REFERENCE TO THE DATUM (0'-0"). THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL OPENINGS, PENETRATIONS, MECHANICAL UNITS, DUCTWORK, CONDUITS, LINTELS, ETC. WITH THE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS.

2. REFER TO A-603 FOR DOO RIGGING LOW STEEL 1 2 3 4 5 6 7 8 1. REFER TO A-601 AND A-60 PARTITION TYPES. 3. ALL EXTERIOR DIMENSIO G SH1 4. ALL INTERIOR DIMENSION 5. SEE ENLARGED PLANS AN INDICATED ON OVERALL 6. PROVIDE FRT BLOCKING L 2'-8 1/4" (V.I.F.) 1'-9" SH1 SH2 SH3 SH4 SH5 SH6 SH7 SH8 SH9 A3 D7 A8 A3 A-321 A-202 EX.1 EX.2 A-301 EX.3 EX.4 A-321 1'-11 1/2" 1'-3 1/2" 22.52 22.52 8'-1 1/2" 4'-0 3/8" 8'-11 1/2" 24'-6" 24'-4" 24'-6" 6'-2" 4'-1 1/8" 4'-0 3/8" 8'-1 1/2" 3'-4 1/2" 1'-11 1/2" 1'-9" 10" 7. ALL INTERIOR PARTITION K METAL SPIRAL STAIR TO FLY GALLERY/RIGGING PLATFORM J 1'-11" METAL STAIR TO FLY GALLERY/RIGGING PLATFORM METAL GUARDRAIL 5'-6 1/2" F 19'-7" 17'-8" CROSS BRACING 12'-7" CROSS BRACING H D8 A-301 2'-4" 19'-7" 12'-10" A8 A-401 G CROSS BRACING F 26'-4" METAL GRATE FLOOR E C CHANNEL RIGGING PLATFORM METAL GRATE FLOOR 19'-7" A7 A-201 E 17'-6 1/4" A7 A-202 ROOF BELOW D D A-201 D7 C 7'-10 1/4" 4'-8" 12'-4" 17'-2 1/4" 17'-0 3/4" BH1 BH3 BH7 BH9 B