"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Similar documents
The set is very simple. It consists of one small box, a small stool, and a small ping- pong table.

"The Road Is Just A Surface" by Anja Garbarek and Jo Strømgren Kompani Technical Requirements

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

FASO DANCE COMPANY KALAKUTA REPUBLIK

Technical Rider "THEATRE" by SUPERAMAS

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

CHELSEA THEATRE. Technical Specifications

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

Borderline. Company Wang Ramirez TECHNICAL RIDER

Technical specifications - Compagnie José Besprosvany Prométhée enchaîné

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

DEREHAM MEMORIAL HALL

Technical Rider. GöteborgsOperans Danskompani. Tour to xxx. Alaska. Table of Contents: 2. Stage. 3. Lighting. 4. Sound. 5. Medical. 6.

Technical Rider. GöteborgsOperans Danskompani. Spirit Tour to XX DATE to DATE. Table of Contents: 1. The Company

TECHNICAL RIDER. If you have problems to fulfil some of our demands, please don t hesitate to contact us. We will find a solution!

Barney Simon Theatre Technical Specifications

Technical Specification

Borderline. Company Wang Ramirez TECHNICAL RIDER

Technical Specification

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Matt Dann Cultural Centre

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

Everyness. Wang Ramirez Company TECHNICAL RIDER

Technical Rider Attached is a technical Rider covering schedule, technical and practical requirements, and contacts. Changes may occur.

[technical list] updated 27/09/2017. Groupe Emile Dubois My Ladies Rock Creation September Playing time : 1h15 without intermission

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Technical Rider. GöteborgsOperans Danskompani. Untitled Black. Tour to.. Table of Contents: 2. Stage. 3. Lighting. 4. Sound. 5. Medical. 6.

TECHNICAL RIDER March 30th 2015

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Technical specifications Main theatre. Sound

TECHNICAL RIDER FOR GROUND FREIGHT-TOURING

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

Technical Specification Pavilion Dance

Technical Rider. Update: may 6th 2008

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

CONTACT FOR TECHNICAL DETAILS AND QUESTIONS

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Technical Specification for the Alley Theatre, Strabane

Technical Pack. Attenborough Arts Centre

The Mannie Manim Technical Specifications

ISLAND HALL TECHNICAL INFORMATION

Avant Garde Dance & The Place Fagin s Twist Tech Spec 2016

TECHNICAL REQUIREMENTS

Main House Technical Specification

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specification

The Haymarket Basingstoke Technical Specifications

JERWOOD VANBRUGH THEATRE

New Theatre Royal Lincoln Technical Information

2017 TECHNICAL SPECIFICATIONS

CENTRE FOR PERFORMING ARTS

ROSE THEATRE BASEMENT

JAMIE ADKINS. Circus INgognitus. Technical Rider Version: January, 2014

Lighthouse Theatre Technical Specification

SHIVER. Technical rider update : 10th feb Premiere at Theater l Arsenic in Lausanne/Suisse the 4th of february 2014

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Uprising & The Art of Not Looking Back

Theatre Technical Specifications

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

THE STREET THEATRE. Technical Specifications

Technical Pack. Embrace Arts at the RA Centre

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Figurines by Lola Maury - touring technical rider

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Technical Specification (Studio Theatre)

Theatre Technical Specification

INFORMATION FOR VISITING COMPANIES

DANCE BASE TECHNICAL SPECIFICATION

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Main Stage Technical Specs - Hall #2

DRM212 DRM215 DRM315 SPECIFICATIONS

Technical Specifications Updated 01/10/2017. Stage

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Technical Production Rider degeneration For venues in mainland Europe

Technical Specification Ardhowen Theatre

LA BALLE ROUGE & QUATUOR

PSYCHIC SALLY PRODUCTION RIDER & FOH REQUESTS (UPDATED 2016)

Latrobe Performing Arts Centre

Harlequin Vinyl floor (permanently installed) Clean removable Harlequin vinyl floor available for hire Rake

Auditorium: 16m x 24m (including stage area) Variable acoustics to suit different performance types

HUECO / Technical Rider

The Bapo (horn) Show

VENUE TECHNICAL REQUIREMENTS

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

TECH SHEET AND INFORMATION (Updated )

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Performance: Romanesco

Technical Specifications

ROSE THEATRE MAIN THEATRE

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Technical Specification 2016

TOURING INFORMATION AND TECHNICAL REQUIREMENTS THE ADVENTURES OF ALVIN SPUTNIK: DEEP SEA EXPLORER BY TIM WATTS

Technical Specifications

Stage. Get In & Parking

TECHNICAL SPECIFICATIONS

Access to back stage is off Fletcher St on the eastern side of the building

COURTYARD!!!!! THEATRE

Technical Information

Transcription:

Although we aim to present our work with simple staging, we also require very high technical standards. If you are unable to meet any of the requirements given here please contact us as soon as possible, and we will be able to adapt the performance. If we arrive and the venue hasn't provided everything exactly as requested, or informed us of problems, we may not be able to perform. 1. General The venue should provide: Stage with performing area 10m. wide x 8m. deep. Absolute minimum is a performing area of 8m. wide and 8m. deep. There must also be a black back curtain, black legs or wings suitable for the venue, and wing space. The lighting bars or grid must be minimum 4,5m above the stage. Black curtains at the back, black legs at the sides and black floor. There must be a black vinyl dance floor, which must be already laid and taped, flat and clean when we arrive. IMPORTANT. The venue should provide a DMX controlled smoke machine for the show. The smoke machine we often use is a Martin Magnum 1200. The smoke machine should be able to give both a heavy smoke and a constant thin haze, and must be fully DMX controlled. It must be possible to disable smoke detectors for the performance. Minimum of one professional sound technician, one stage and two lighting technicians for rigging, available from 09.00 on the day of first performance. We also need staff to clean the floor before the performance. We prefer to get out immediately after the final performance and this takes around an hour. A very good PA system- mixer, amplifiers and speakers exactly as listed. Please see sound notes for details. Lighting equipment exactly as listed. Please see lighting notes and plan. Please note that the 18 x zoom profiles are crucial for this show. Please inform us as soon as possible if there are not 18 good profiles available. A perfect blackout is essential. Dressing rooms with showers and bottled water and fruit for the performers and technicians, if possible with some light food. We need access to washing and drying facilities and an iron for the costumes after each show. The venue must provide stage plans (AutoCad preferred), lists of available lighting and sound equipment, and, if possible, photographs or video of the stage as soon as possible. We need approximately 8 adaptors for our technical equipment which has European Schuko- CEE 7/4- plugs, to the local power sockets. One for a dimmer channel, 7 for direct 230v power. (See http://www.powercords.co.uk/standard.htm). The JSK technical contact is Stephen Rolfe. Tlf: (+47) 90168766. E-mail: stephen@jskompani.no Stephen Rolfe 1 of 5 9. December 2015

2. Details The performance lasts about one hour without interval. There are three male and one female performers. There are 2 JSK technicians. The sound and lighting are operated from the centre back of the auditorium. We always use our own lighting and sound operators. If the lighting and sound positions are not together, there must be communication between them. The stage The performing area is ideally 10m. wide x 8m. deep. Absolute minimum is 8m. wide and 8m. deep, but must have at least 1m. wide legs in addition, and wing space. The floor must be black dance floor, which must be very flat, taped and clean when we arrive. We need a black curtain at the back, a crossover behind is needed, and also 3 or more black wings, legs or curtains on each side. The masking should just be arranged to suit the venue, the positions on the lighting plan are only a suggestion. Borders to mask the lighting bars are nice if possible. The set The set is very simple. It consists of one small box, a small stool, and a small ping-pong table. Staff needed If possible, the lighting and sound equipment should be pre-rigged. If the get-in is on the day of the first performance, we will need to begin work at 09.00, and require at least two technicians for rigging lighting, one stage technician for the masking, and one sound technician who knows the theatre sound system. There should be staff to clean the floor before the performance. We prefer to get out immediately after the final performance and this normally takes around one hour. For the get-out we need just one technician. Derigging the venue's lighting, masking and sound equipment is the responsibility of the venue. There must be no rehearsals or any other activity on stage from the time we get in until we leave unless agreed in advance. Stephen Rolfe 2 of 5 9. December 2015

Overview of technical baggage: Three large, flight boxes. Description: Three big aluminium boxes. Weight: Total of 76 kg. Case 1: Measurements: Length 78 cm, width 58 cm, height 61 cm. Weight: 27 kg. Content: Technical equipment. Case 2: Measurements: Length 78 cm, width 58 cm, height 41,5 cm Weight: 26 kg. Content: Props, puppet. Case 3: Measurements: Length 78 cm, width 58 cm, height 41,5 cm Weight: 23 kg. Content: Focus carpet. Lightning and Sound briefcase (small briefcases) Description: 2 Small briefcases Weight: about 5 kg each, a total of about 10 kg Personal luggage is additional (1 large bag + hand luggage per person) Stephen Rolfe 3 of 5 9. December 2015

3. Lighting Please see the lighting plan. The lighting equipment needed is: Minimum 36 dmx dimmer channels. 18 x 1kw. or 750w. zoom profiles. Must have very clean lenses, and four perfectly working shutters. These should have a beam angle of 35 degrees or more. 5 x 1kw Fresnels or PC's (could well be profiles if you have enough). Must have barndoors. 5 x CP61 Parcans. 10 x CP62 Parcans. 8 x floorstands for Parcans. 1 x direct power supply, and DMX connection at the centre back for the smoke machine, which the venue should provide. Smoke detectors must be disabled for any rehearsals and the performance. 9 x dimmer channels on the floor. There must be a ladder, genie lift or other means of getting up to the lights for focussing. Minimum grid/ lighting bar height is 4,5m. We bring all colour filters required and the UV lamps. All lighting instruments must have working barndoors or shutters. All profile lenses must be clean and have 4 working shutters. The 18 profiles are very important for the show. Please let us know as soon as possible if you have any problem with this. The venue should provide a DMX controlled smoke machine for the show. The smoke machine we often use is a Martin Magnum 1200. The smoke machine should be able to give both a heavy smoke and a contant thin haze, and must be fully DMX controlled. It must be possible to disable smoke detectors for the performance. We bring our lighting controller (PC + grandma 2Port Node, 512 channels) and need to connect this to the theatre DMX (standard 5 pin DMX). Important! DMX must be on one single universe because of our lighting control. Please contact us as soon as possible if you see a problem with this, if the theatre dimming system is not DMX controlled or if you foresee any other problem with lighting control. The sound and light are operated from the same place at the centre back of the auditorium. If they are not in the same place, we will require some form of communication between the two positions. Stephen Rolfe 4 of 5 9. December 2015

4. Sound On stage: We require 3 loudspeakers on stands, all of the same make and model, placed at the back of the stage (upstage) in an LCR configuration, all on separate lines from the mixer. If possible, the Left and Right speakers of this LCR setup should be crossed over and supported by subwoofers, providing a full range sound system on stage. (This is highly preferred, but not a requirement) These loudspeakers and stands should be black, and the 3 LCR loudspeakers should be of identical make/ model. These loudspeakers are used for the majority of the sound content in this show, and MUST PLAY LOUD. Public Address: We require a high quality PA system providing even coverage of the audience. Minimum 100dB(A) undistorted, and a linear frequency response of 40Hz - 18kHz or better. All loudspeakers (stage monitors included) must be of very high quality; Meyer, Nexo, JBL or L-Acoustics preferred (never Electrovoice or Peavy, and not made of plastic!) The PA system should be set up as a full range stereo setup integrating its sub woofers. If the subs are on separate channels, additional mixer outputs will be required. Front of House: We require a high quality mixing desk. Minimum 10 inputs and 5 outputs, all controlled separately. Digital mixers are preferred, as we time-align the PA to the stage monitors. In the case of an analogue mixer, we would appreciate a stereo delay processor for the PA. Each mixer channel should have a 4 band EQ whereof at least 2 bands have sweepable mids and adjustable Q. If the mixer can not supply this, 31band equalizers on all mixer outputs will be highly appreciated (though, not a requirement) In addition, we require: a 31band EQ for the PA system (can be omitted if the mixer has EQ on this output), one SM58 microphone or similar at FOH mixing position (talk to stage), one stereo minijack to XLR cable or equivalent at FOH (to connect an mp3 player or similar device to the mixer). Other notes: If possible, all loudspeakers and PA should be rigged before our arrival. All loudspeaker processors and crossovers should be available to us for fine tuning. All wiring visible on stage should be carried out using black cables (not grey, not blue) The sound is operated from the centre back of the auditorium. We bring 1 mac computer and 1 sound card (8 outputs on XLR / balanced jack), and this is our only sound source during the show. Finally, please note that these are a part of the JSK contract. If we arrive and the equipment, staff or facilities we have requested are not available, we may not be able to perform the show. Please let us know as soon as possible if you have any problem providing anything we ask for. We can usually make substitutions or changes if we know about any problems in advance. Stephen Rolfe 5 of 5 9. December 2015