Parity Quality Beam (PQB) Study

Similar documents
Polarized Source Development Run Results

G0 Laser Status Parity Controls Injector Diagnostics

Status of the Jefferson Lab Polarized Beam Physics Program and Preparations for Upcoming Parity Experiments

POLARIZED LIGHT SOURCES FOR PHOTOCATHODE ELECTRON GUNS AT SLAC?

PQB Meeting. Caryn Palatchi 02/15/2018

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

DAQ Systems in Hall A

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

Hall-B Beamline Commissioning Plan for CLAS12

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Model 4700 Photodiode Characterizer

Lecture 14: Computer Peripherals

Beam Loss Detection for MPS at FRIB

arxiv: v2 [physics.ins-det] 26 Jun 2016

Digital BPMs and Orbit Feedback Systems

5 MeV Mott Polarization Measurement Procedure--DRAFT

The FLASH objective: SASE between 60 and 13 nm

Front End Electronics

The PEFP 20-MeV Proton Linear Accelerator

Update on DAQ for 12 GeV Hall C. Brad Sawatzky

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.

40-Meter Subsystems: As LIGO-Like as Possible

Update on DAQ for 12 GeV Hall C

Linac 4 Instrumentation K.Hanke CERN

Minimize your cost for Phased Array & TOFD

Beamline improvement during g2p experiment. Pengjia Zhu

ASK THE EXPERTS: Procedure for Verifying Magnetic Pickup Signal Integrity Using a Windrock Portable Analyzer

P. Emma, et al. LCLS Operations Lectures

LHC Beam Instrumentation Further Discussion

4 MHz Lock-In Amplifier

CAEN Tools for Discovery

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

North Damping Ring RF

Electrical connection

Status of the X-ray FEL control system at SPring-8

Fast Orbit Feedback at the SLS. Outline

Figure 1. MFP-3D software tray

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

SU17 Series Fiber Optic Sensors

CBF500 High resolution Streak camera

SPATIAL LIGHT MODULATORS

Users Manual FWI HiDef Sync Stripper

Absolute Encoders Multiturn

Instrumentation and analysis progress for g2p experiment

Diamond detectors in the CMS BCM1F

ST800K-U Optical Power Meter. User Manual V1.0

GFT Channel Digital Delay Generator

CSC Data Rates, Formats and Calibration Methods

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

WaveDriver 20 Potentiostat/Galvanostat System

Amplification. Most common signal conditioning

Advanced Test Equipment Rentals ATEC (2832)

BCM Calibration for E Abstract

An Operational Diagnostic Complement for Positrons at CEBAF/JLab

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

2 MHz Lock-In Amplifier

The hybrid photon detectors for the LHCb-RICH counters

potentiostat/galvanostat

In-process inspection: Inspector technology and concept

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

8 DIGITAL SIGNAL PROCESSOR IN OPTICAL TOMOGRAPHY SYSTEM

OFI-400 Series Optical Fiber Identifiers. OFI-400 Series Models

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

FEL TEST PLAN WORKSHEET

Electrical connection

Agilent 5345A Universal Counter, 500 MHz

PCI-DAS6034, PCI-DAS6035, and PCI-DAS6036

Linear encoders without bearings incremental System for linear motion feedback

DPD80 Visible Datasheet

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

O-to-E and E-to-O Converters

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

ALGORHYTHM. User Manual. Version 1.0

Specifications. Reference Documentation. Performance Conditions

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Test time metrics for TP2 waveforms

Capability Improvements: Polarized Photoinjector*

Commissioning and Initial Performance of the Belle II itop PID Subdetector

16-BIT LOAD CELL/DUAL STATUS INPUT

Development at Jefferson Lab

L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

LUT Luminescence scanners: Seeing what no-one else can

DPD80 Infrared Datasheet

MP212 Principles of Audio Technology II

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Fluke /

Paranormal Devices Built By Bill Chappell. For some weird reason people think I only build things that talk!

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA

64ch DAQ system with BioWare

Development of BPM Electronics at the JLAB FEL

Synthesized Clock Generator

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Experiment 9A: Magnetism/The Oscilloscope

beam dump from P2 losses this morning

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

Beam test of the QMB6 calibration board and HBU0 prototype

Klystron Lifetime Management System

XC-77 (EIA), XC-77CE (CCIR)

Transcription:

Parity Quality Beam (PQB) Study Injector Group November 10, 2008

Thanks to: Roger Flood, Pete Francis, Paul King, Bob Michaels, Julie Roche

Notes: 1. For each BPM, the wires are: +X+, +X-, +Y+, +Y-. 2. BPM 0R06 is not connected as of October 16, 2008. 3. There are only two injector BPMs we are not reading: 0R03 and 0R04. ADC1 Chan 1 Chan 2 Chan 3 Chan 4 Chan 5 Chan 6 Chan 7 Chan 8 QPD pm QPD pp QPD mm QPD mp ADC2 1I02 1I04 ADC3 1I06 0I02 ADC4 0I02A 0I05 ADC5 0I07 0L01 ADC6 0L02 0L03 ADC7 0L04 0L05 ADC8 0L06 0L07 ADC9 0L08 0L09 ADC10 0L10 0R01 ADC11 0R02 0R05 ADC12 0R06 BCM 0L02 Battery 3 Battery 1 Battery 4 Battery 2 Phase Monitor

DAQ Signals Notes: 1. At 100 µa, BCM0L02 signal is +2.6 V. 2. The average BPM wire signal is +4 V. 3. The Battery signal is +3.0 V. 4. The Phase Monitor signal is ±2 V pp Phase Monitor

Injector BPMs Notes: 1. iocse11, iocse12, and iocse19 have TRANSPORT style IF cards 2. Sampling time is 140 µs 1I02, tune beam 1I02, tune beam 1I02, no beam 1I02 X+, no beam

Notes: 1. Chan 1: X+, Chan 2: X-, Chan 3: MPS (Trigger) CW PC ON CW PC OFF CW PC ON CW PC OFF

Inputs: 1. LEMO_0: Beam Sync FIBER_9 Helicity Board Outputs (Fiber-optic Signals): 1. Real time helicity: FIBER_2 to Helicity Magnets, FIBER_10 to Pockels Cell 2. QRT: FIBER_3 to Halls and Mott Polarimeters 3. MPS: FIBER_4 to Halls and Mott Polarimeters 4. T120: FIBER_5 (¼ T_Stable = 8.3333 ms) 5. Reporting Helicity: FIBER_6 to Halls and Mott Polarimeters, iocse9 and iocse14 6. Pair Sync or Helicity Delay: FIBER_7 to Halls and Mott Polarimeters

Software: 1. MPS (T-Settle): 500, 200, 100, and 60 µs 2. Reporting Delay: No Delay, 2, 4, or 8 Cycles 3. Helicity Pattern: Pair (+- or -+) or Quartet (-++- or +--+) 4. Pattern: Toggle or Random 5. Integration Window (T_Stable): 33.3332 ms or 3.920 ms 6. CLOCK: Free running (f = 29.xx = 1/(T_Settle+33.3332 ms) or 30 Hz Beam Sync (f = 30 = 1/(T_Settle + T_Stable) 7. Output Select: Pair Sync or Helicity Delay (used with G0 dummy Pockels Cell) 8. G0 Delay: No Delay, 1, 2, or 4 Cycles. Delay of helicity signal for Helicity Delay 9. Helicity Cycle Rate: 30 Hz or 250 Hz

Should we build a new Helicity Board? Easy to program More choices of T_Settle and helicity reversal frequencies

Notes: 1. The 30 Hz Beam Sync signal is missing 2. On Monday October 13, 2008, the Helicity Board was re-programmed: T_Settle: 10, 60, 100, 500 µs Helicity Cycle Rates: 30 Hz or 1 khz Integration Window (T_Stable) is 980 µs for 1 khz 3. Parity ADC internal programming: I. For 30 Hz helicity reversal: Acquisition starts 40 µs after the gate begins There are 4 blocks of 4161 samples/block for each gate. The acquisition time is 33.328 ms II. For 250 Hz helicity reversal: Acquisition starts 40 µs after the gate begins There are 4 blocks of 485 samples/block for each gate. The acquisition time is 3.880 ms III. For 1 khz helicity reversal: Acquisition starts 40 µs after the gate begins There are 4 blocks of 117 samples/block for each gate. The acquisition time is 936 µs

Cycle Rae (HZ) MPS (µs) MPS (Hz) QRT (Hz) Helicity (ms) Helicity (Hz) 30 500 29.58 7.386 33.83 14.78 30 200 29.76 7.451 33.53 14.91 30 100 29.90 7.474 33.43 14.96 30 60 29.94 7.485 33.39 14.97 250 500 226.3 56.56 4.420 113.1 250 200 242.7 60.68 4.120 121.4 250 100 248.8 62.68 4.020 124.4 250 60 251.3 62.81 3.980 125.6 Notes: 1. These values as measured by a scope 2. Signals to Parity DAQ: MPS (T-Settle), QRT, Reporting Helicity, and Pair-Sync 3. The length and frequency of Pair-Sync are identical to Helicity 4. The length of QRT is identical to Helicity 5. The integration window is generated by MPS AND Pair-Sync 6. The integration window for 30 Hz is 33.33 ms and for 250 Hz it is 3.92 ms

Parity ADCs Accepts bi-polar signals of ±10 V Maximum sample period is 500 khz Each sample is 18-bit measurement Single bit error on one sample is 76.29 µv Helicity Reversal Rate (Hz) Acquisition Window (µs) Number of Samples Error on Event Mean (µv) Maximum Number of ADC Channels 30 33,328 16,664 0.59 ±2,184,183,808 250 3,880 1,940 1.73 ±254,279,680 1,000 936 468 3.53 ±61,341,696

Battery Signals Pedestals, Run 504 Random, No Delay, Run 505

Battery Signals (3 V) Random, 8-Cycles Delay, Run 361

Battery Signals Battery1 and Battery2 Round Trip to Laser Table Random, 8-Cycles Delay, Run 398 Random, No Delay, Run 406

Pockels Cell OFF No Helicity Pickup Random, 8-Cycles Delay, Run 499 Random, No Delay, Run 502

Pockels Cell Alignment With a Spinning Half Wave Plate or a Spinning Linear Polarizer and a Scope, the Circular polarization was maximized by checking: 1. Laser isogyro pattern 2. Pockels Cell Pitch, Yaw, Roll, X & Y 3. Pockels Cell Voltages The above was checked for IHWP IN and OUT and for 30 Hz and 250 Hz helicity reversal The Circular polarization = 99.97 % and the Linear Polarization = 2.56 %

Hall A IA

RHWP Study

T-Settle Study (500, 200, 100, 60 µs) 30 Hz 1. Run 399: PC OFF, IHWP IN, 500 µs 2. Run 381: IHWP OUT, 500 µs 3. Run 382: IHWP IN, 500 µs 4. Run 383: IHWP IN, 200 µs 5. Run 384: IHWP IN, 100 µs 6. Run 385: IHWP IN, 60 µs

T-Settle Study (500, 200, 100, 60 µs) 250 Hz 1. Run 391: PC OFF, IHWP IN, 500 µs 2. Run 394: IHWP OUT, 500 µs 3. Run 392: IHWP IN, 500 µs 4. Run 395: IHWP IN, 200 µs 5. Run 396: IHWP IN, 100 µs 6. Run 397: IHWP IN, 60 µs

60 Hz Noise and Line Phase Monitor

60 Hz Noise Search with Extech 480824 EMF Adapter and a Fluke 87 Three high reading areas: 1. PSS 500 kev MBO0I06 Dipole current sensor 2. VIP0L02 ion pump and its power supply 3. VIP0L03 ion pump and its power supply

Beams Crosstalk Run 410: Hall A 120 µa, Hall C 0 µa Run 412: Hall A 0 µa, Hall C 110 µa Run 413: Hall A 120 µa, Hall C 0-110 µa, Hall C laser phase 55 degree Run 414: Hall A 120 µa, Hall C 110 µa, changed Hall C laser phase

Hall C Current Scan

Hall C Laser Phase Scan

1 khz Helicity Reversal

Cycle Rae (HZ) MPS (µs) MPS (Hz) QRT (Hz) Helicity (ms) Helicity (Hz) 30 500 29.58 7.386 33.83 14.78 30 100 29.90 7.474 33.43 14.96 30 60 29.94 7.485 33.39 14.97 30 10 29.99 7.496 33.34 14.99 1000 500 675.7 168.9 1.480 337.8 1000 100 925.9 231.5 1.080 463.0 1000 60 961.5 240.4 1.040 480.8 1000 10 1010 252.5 0.9900 505.1 Notes: 1. These values as measured by a scope 2. The integration window for 1 khz is 0.980 ms

T-Settle Study (500, 100, 60, 10 µs) 1 khz 1. Run 477: PC OFF, IHWP OUT, 100 µs 2. Run 470: IHWP IN, 100 µs 3. Run 471: IHWP OUT, 100 µs 4. Run 472: IHWP OUT, 100 µs, Toggle, No Delay (not analyzed yet) 5. Run 479: IHWP IN, 100 µs, Toggle, No Delay (not analyzed yet) Notes: 1. CODA gave error messages with the other T_Settle choices

Summary The parity DAQ, BPMs, and Analysis are working fine 30 Hz: 1. The standard PQB at 30 Hz was achieved 250 Hz: 1. The PQB at 250 Hz very similar to 30 Hz otherwise for the 60 Hz noise 1 khz: 1. The PQB at 1 khz very similar to 30 Hz, again issues with 60 Hz noise (less sensitive than at 250 Hz) What s next? 1. Finish analysis: 4 blocks, Phase Monitor, Batteries, 2. Study 1 khz for all T_Settle choices 3. Photocathode rotation 4. Check Helicity Magnets, Mott Polarimeters at 1 khz helicity reversal