GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Similar documents
Ø 1000 * 588 mm 50 kg

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Detailed Specifications & Technical Data

Revision No. 4 Page No. Page 1 of 7

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

LD Series High Performance Loose Tube Fiberoptic Cables

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Mining and Petrochemical Fiber Optic Cables

TECHNICAL SPECIFICATION

Product Catalogue. Fibre Optic Cable

FREEDM Loose Tube Interlocking Armored Cables

Micro duct Cable with HDPE Sheath for Installation by Blowing

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

OPTICAL FIBRE CABLE NETWORK 2004/1

Empowering businesses through innovative network solutions.

Number of Fiber 6 Core 12 Core. Part Number

Number of Fiber 12 Core 24 Core 48 Core. Part Number

SPECIFICATION. Optical Fiber Cable

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

1. General. 1. Scope. 2. Quality Assurance

Number of Fiber 6 Core 12 Core 24 Core 48 Core

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

HITRONIC Optical Transmission Cable

SOLO ADSS Short-Span Cables, Fibers

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

TENDER SUMMARY. Tender Title:

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

FIBRE OPTIC CABLE SOLUTIONS

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Industry solutions: Broadcast

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

OPTICAL CABLE FIBER-LAN INDOOR

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

HERA RETICULATION FIBRE CABLE PRODUCT REQUIREMENTS

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

AFL Telecommunications

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Material Description Quantity UOM

Cables for robot applications

We design, build, and manage web-scale networks for the needs of tomorrow. System Integration SERVICES

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

Table of Contents. Open Matrix System (OMS) 1-2

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

The World Of Professional Fiber Optics. safe flexible reliable

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

FIBER OPTICS FIBER OPTIC CABLE FOR VOICE AND DATA TRANSMISSION

INDUSTRY SOLUTIONS: MINING

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

Instrumentation & copper telecom cables

THE INFORMATION GATEWAY FIBRE OPTIC CABLES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

Content. 1.4 Fiber Cable Assembly

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

Triax TechInfo. Installing and pulling Fibre Optic cables

Installation of Solo ADSS All-Dielectric Self-Supporting Fiber Optic Cables

OPTICAL FIBER CABLES FTTH. SPLITTER. ACCESSORY

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

Mini-breakout & Mini-bundle cable. Riser cabling solution

Cable installation guidelines

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

40G SWDM4 MSA Technical Specifications Optical Specifications

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Fiber Optic Cable System

Table of Contents. Specifying AFL Premise Optical Cables Outdoor. Enterprise. Interconnect. MicroCore. Indoor.

Gear up for the future.

SECTION 4 TABLE OF CONTENTS

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

ETSI ES V1.1.1 ( )

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

PRO SERIES FIBRE-150M

Table of Contents. Teldor Cables and Systems Ltd.

STRUCTURED CABLING SYSTEMS (SCS)

Transcription:

GBRE Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 84 96 62.5/125-OM1 GBRE184 GBRE196 -OM2 BW /1200 GBRE284 GBRE296 -OM3 GBRE384 GBRE396 -OM2e GBRE484 GBRE496 -OM2 BW 500/500 GBRE584 GBRE596 -OM4 GBRE684 GBRE696 9/125 ITU G.655 GBRE784 GBRE796 9/125 ITU G.652D-OS2 GBRE884 GBRE896 Std. plywood reel (non-returnable) Std. delivery length Ø 1400 * 900 mm 120 kg 2100 ± 100m Applications For outdoor use in structured (data) wiring systems such as (campus backbone). For outdoor use in networks for telecom, cable TV and/or broadcast. Suitable for direct burial (crush 400 N/cm). Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Features & Benefits Dry Construction. Improved rodent protection provided by waterblocking glassyarns. Predicted lifetime > 30 years.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794) 1. Dielectric central element of glass reinforced plastic (GRP), also as protection against kinks, surrounded by swelling yarns. 2. Jelly filled (non-dripping and silicon-free) loose tubes with primary coated optical fibres (Ø 250 ± 15 µm). Individually colour coded optical fibres: red green blue yellow violet pink orange black grey brown white turquoise. 3. The loose tubes are stranded around the central element, if necessary with fillers (PE-natural), surrounded by swelling tape. Colour coding of the loose tubes: 1. red 2. green rest white. 4. Swellable (for the longitudinal watertightness) glass yarns as strength members. 5. Black UV resistant PE outer jacket. Identification: BELDEN OFC cable type number x fibre type + date-, meter- and P/N marking. Mechanical Data No. of fibres Max. 96 Cable core 8 tubes Ø Central element (mm) 3.0/4.3 Ø Loose tube (mm) 2.5 Ø nom./max. (mm) 15.3 / 15.6 Energy of flame (kj/m) 4900 Weight (kg/km) 170 2

Optical Characteristics Characteristics (cabled) Single-Mode Matched-Cladded optical fibres according to ITU. European Partnumber Coding, Position 5 Fibre-Type Mode-Field /CladdingDi ameter (um) Wavelength Attenuation average/ max. (db/km) Dispersion (ps/(nm-km) PMD (ps/km) Cable Cut-off Wave-length 8 9/125 G.652D OS2 9.2 ± 0.4 125 ± 0.7 1310 1 0.32 / 0.40 0.21 / 0.30 3.5 18 0.2 1260 7 9/125 G.655 8.4 ± 0.6 1 0.25 / 0.30 3.5 8.5 < 0.1 A 1260 Note A- Link design value Characteristics (cabled) Multi-Mode Graded-Index optical fibres according to IEC 60793 European Partnumber Coding, Position 5 Fibre-Type Mode-Field Diameter (um) Wavelength Attenuation average/ max. (db/km) Bandwidt h (MHzkm) Ethernet Performance (m) 1GBE 10 GBE Num. Apert. (µm) Refr. Index 1 62.5/125 OM1 62.5 ± 2.5 2.7 / 3.2 0.6 / 1.1 200 275 33 0.275 ± 1.495 1.490 5 OM2 2.4 / 3.0 0.7 / 1.0 82 1.481 1.476 2 OM2 2.3 / 2.8 0.6 / 0.9 1200 82 1.481 1.476 4 OM2e 50 ± 2,5 2,3 / 2,8 0,6 / 0,9 1200 750 2000 110 na 1,481 1,476 3 OM3 2.5 / 3.0 0.5 / 1.0 1500 900 300 1.482 1.477 6 OM4 2.5 / 3.0 0.5 / 1.0 0 900 1.482 1.477 A test report (attenuation) is supplied with each delivery. 3

Mechanical, Physical and/or Environmental Characteristics Requirements Temperature range according to IEC 60794-1-2-F1 Tansport/storage Installation Operation Pulling tension according to IEC 60794-1-2-E1 Long term Short term Bending radii for fibres and tubes Installation/operation Watertightness according to IEC 60794-1-2-F5 Crush resistance according to IEC 60794-1-2-E3 Cable Bending radii cable Static according to IEC 60794-1-2-E11 Dynamic according to IEC 60794-1-2-E6-30 to + 70 C -5 to + 50 C -30 to + 70 C 4000 N 8000 N >25 mm Yes 20 KN/m 15 x ø 20 x ø Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Cables for indoor/outdoor use. Non-standard cable constructions, colors, details and/or additional information regarding specifications are available on request. 4

Revision Rev. Description Date Init. 02 OM3+ changed to OM4 13/10/09 JW 03 OS2 added 30/11/09 JW 04 Changed energy 22/11/10 TvR Date: 18/12/08 Page 1 of 1 Part Number: Orig.: SN Review: GBRE 5