QD1 Incremental Encoder Interface Revision: 12/91

Similar documents
CS210 Enclosure Relative Humidity Sensor Revision: 10/07

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers Revision: 2/11

INSTRUCTION MANUAL. IceFree3A and IceFree3V Interfaced with Campbell Scientific Dataloggers 4/15. App. Note Code: 2WI-O

CS525 ISFET ph Probe Revision: 10/11

INSTRUCTION MANUAL V Barometric Pressure Sensor. May Copyright 2007 Campbell Scientific (Canada)Corp.

INSTRUCTION MANUAL. Model 108 Temperature Probe Revision: 3/14. Copyright Campbell Scientific, Inc.

INSTRUCTION MANUAL. Model 107 Temperature Probe Revision: 2/18. Copyright Campbell Scientific, Inc.

Revision 1.2d

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Absolute Rotary Encoder E6CP

Operating Instructions

Temposonics. Magnetostrictive Position Sensors. L Series (Model LH) to G-Series Linear-Position Sensor. Cross Reference A

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

EZ Encoder : Optical Incremental

INSTRUCTION MANUAL. Model 109 Temperature Probe Revision: 4/18. Copyright Campbell Scientific, Inc.

800 Displaying Series Flowmeter

INSTRUCTION MANUAL. Model 107 Temperature Probe Revision: 2/18. Copyright Campbell Scientific, Inc.

Material: Weight: IP Rating: Cable: Connector:

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

EM1. Transmissive Optical Encoder Module Page 1 of 9. Description. Features

The measurements are stored in non-volatile memory, which retains data even when the power down.

INSTRUCTION MANUAL. Model 107 Temperature Probe Revision: 2/18. Copyright Campbell Scientific, Inc.

Smart-Encoder : Optical Incremental

EDL8 Race Dash Manual Engine Management Systems

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

EZ Encoder : Optical Incremental (P Series)

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

Analogue output module DAO 081

Single Axis Position Controller

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

Data Pattern Generator

DT3130 Series for Machine Vision

DEX Fruit & Stem Growth Dendrometer User Manual

Operating Instructions

Linear Probe Encoder Page 1 of 7. Description. Features

SPA MICROPROCESSOR SPEEDOMETER INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS PAGE 3...

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Advanced Test Equipment Rentals ATEC (2832)

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

BER MEASUREMENT IN THE NOISY CHANNEL

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Advanced Test Equipment Rentals ATEC (2832)

BNC-2120 INSTALLATION GUIDE. Connector Accessory for Multifunction DAQ Devices

Step-Lok Manual V1.0 (preliminary) Last edited Feb 23 / 2015

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Training Note TR-06RD. Schedules. Schedule types

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

HOBO H Energy Logger

Type SCH94FO. Type SCH94FO. Description

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

(Cat. No IJ, -IK)

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m)

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Operating instructions Electronic preset counter Type series 717

4.9 BEAM BLANKING AND PULSING OPTIONS

Driver circuit for CMOS linear image sensor

Absolute encoders multiturn

Model IQ4-PC User Manual Revision Date:

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

TriLIN Program Utility TPU_ TriLIN Programming Manual

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

MODEL LDL-C Miniature Non-Contacting Linear Encoder Kit

VGA to HDMI Scaler x1200

Process Transmitter RMA 422

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

User s Manual. Log Scale (/LG) GX10/GP10/GX20/GP20 IM 04L51B01-06EN. 1st Edition

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

OPERATION MANUAL MODEL DF3000 DIGITAL WEIGHT INDICATOR REVISION A-1

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

DMC550 Technical Reference

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

LD OEM/LD PDS/LD PeCo

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface

VBOX 3i Dual Antenna Measures Slip and Pitch/Roll (RLVB3iSL)

Displays AND-TFT-5PA PRELIMINARY. 320 x 234 Pixels LCD Color Monitor. Features

LCD4215 Installation Guide 42 LCD Display Rev 1.1

FX0N-3A SPECIAL FUNCTION BLOCK

PRODUCT DATA SHEET FEATURES

LAUREL ELECTRONICS, INC.

Transmitter Interface Program

VBOX 3i. 100Hz GPS Data Logger (VB3i-V3) Features

PAM-1840 Preamplifier Operation Manual

MICROMASTER Encoder Module

MT32 Telemetry Multi channel telemetry system for rotating application

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Transcription:

QD1 Incremental Encoder Interface Revision: 12/91 Copyright 1987-1991 Campbell Scientific, Inc.

This is a blank page.

PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc. (CSI) primarily for the US market. Some spellings, weights and measures may reflect this origin. Some useful conversion factors: Area: 1 in 2 (square inch) = 645 mm 2 Length: 1 in. (inch) = 25.4 mm 1 ft (foot) = 304.8 mm 1 yard = 0.914 m 1 mile = 1.609 km Mass: 1 oz. (ounce) = 28.35 g 1 lb (pound weight) = 0.454 kg Pressure: 1 psi (lb/in2) = 68.95 mb Volume: 1 US gallon = 3.785 litres In addition, part ordering numbers may vary. For example, the CABLE5CBL is a CSI part number and known as a FIN5COND at Campbell Scientific Canada (CSC). CSC Technical Support will be pleased to assist with any questions. About sensor wiring Please note that certain sensor configurations may require a user supplied jumper wire. It is recommended to review the sensor configuration requirements for your application and supply the jumper wire is necessary.

QD1 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat bookmarks tab for links to specific sections. 1. Function...1 2. Specifications...1 3. Connections...1 4. Datalogger Programming...1 4.1 Powering the QD1...2 4.2 Measurement...2 4.3 Processing...2 5. Entering the Reference Offset...2 6. On-Site Check-Out...2 7. Range vs. Resolution...2 8. QD1 Timing Diagram...3 Appendix A. Shaft Encoder Connections and Example Program... A-1 A.1 Shaft Encoder Connections... A-1 A.2 Example Program... A-1 i

QD1 INCREMENTAL ENCODER INTERFACE 1. FUNCTION The QD1 is designed as a general purpose quadrature decoder to interface CSI's CR10, 21X, and CR7 dataloggers to incremental encoders. This manual focuses on using the QD1 with commercially available shaft encoders used in water level applications (see Appendix). If there are other incremental encoders of interest, please contact CSI's Marketing Department for support. As the encoder rotates, it produces two square waves which are 90` out of phase with each other. When the rotation is reversed, the relation of the two square waves is reversed. The QD1 decodes the two square waves and gates a voltage pulse to a datalogger pulse counting channel (refer to Section 8). Two pulse counting channels are required, one for each direction of encoder rotation. 2. SPECIFICATIONS Datalogger compatibility: CR10, 21X, CR7 Power supply: 4 to 5.6 V Current drain: 0.2 to 0.4 ma avg. Operating temperature: -25 to +50 C. Humidity: 0 to 95%, noncondensing Minimum time between input transitions: 0.75 ms*** Output pulse width: 0.25 ms @ 25 C Signal magnitude, Volts: 0 (low), supply voltage (high) Dimensions (L x W x D, inches): 2.9 x 1.7 x 0.85 Weight (lbs.): 0.22 ***NOTE: The minimum time between input transitions implies a rate of 1333.3 counts/sec. To realize this specification, the time between transitions must be evenly spaced; a function of the encoder. A diagram explaining "minimum time between transitions" is given in Table 1, Section 8. 3. CONNECTIONS Connections between the QD1 and the datalogger are shown below. Connections from the QD1 to two commercially available shaft encoders are shown in the Appendix. (datalogger side) QD1 DATALOGGER +5 +5V (CR10) or CAO (21X, CR7) P1 PULSE CHANNEL P2 PULSE CHANNEL GRND G (CR10) or GRND (21X, CR7) NOTE: Datalogger pulse input channels should be sequential for efficient datalogger programming. 4. DATALOGGER PROGRAMMING The program must measure the QD1 output and process the "up" and "down" counts to determine stage. For 21X and CR7 dataloggers, an additional step is required to power the QD1 from a Continuous Analog Output (CAO) channel. The following steps outline the procedure. Notes on the various steps are presented in following sub-sections. An example program is given in the Appendix. 1. Load QD1 power supply level, 5000 mv, into an input location (Instruction 30, required for 21X and CR7 only) 2. Enable CAO to output QD1 supply voltage (Instruction 21; required for 21X and CR7 only) 3. Measure QD1 up count and down count output on 2 pulse count channels (Instruction 3, 2 reps, high frequency option) 4. Stage = up count + stage (Instruction 33) 5. Stage = stage - down count (Instruction 35) 1

QD1 INCREMENTAL ENCODER INTERFACE 4.1 POWERING THE QD1 21X and CR7-5 VDC must be supplied to the QD1 continuously. When used with the 21X or CR7 dataloggers, a Continuous Analog Output (CAO) port may be programmed to power the QD1. CAO channels are located on the panel of the 21X and the 725 Excitation Card of the CR7. Instructions to send 5 V out the CAO port should occur before the measurement instruction, and must be repeated at least every minute. This implies a maximum program execution interval of one minute. If the CAO voltage is not refreshed every minute, the voltage level may sag below the minimum QD1 operating voltage. CR10 - When used with the CR10, the QD1 may be connected to one of the two 5 VDC terminals located on the CR10WP Wiring Panel. 4.2 MEASUREMENT Output from the QD1 is measured with I/O Instruction 3 (Pulse Count), using the high frequency option. Two pulse count channels must be measured, one for "up" counts and one for "down". The Multiplier to be used depends on the number of counts per revolution of the shaft encoder and the circumference of the attached wheel, as shown below. MULTIPLIER = WHEEL CIRCUMFERENCE/(COUNTS/REVOLUTION) Engineering units logged by the datalogger are the same as those used for wheel circumference. An Offset of zero should be entered in the Pulse Count I/O Instruction. Section 5 discusses entering an offset to set the measurement equal to a reference elevation. 4.3 PROCESSING Processing Instructions are used to determine the stage from the measured up and down counts. The new stage is calculated by adding the existing stage to the up counts and storing the sum back in the existing stage location. The down count value is then subtracted from the sum, and the result is stored back in the stage location. This routine minimizes the number of Input Locations required to calculate stage. 5. ENTERING THE REFERENCE OFFSET The offset, which sets the stage value equal to some reference point, should be entered after the system has been installed and the float is resting on the water surface. Enter the *6 Mode and advance to the stage Input Location. Press the "C" key to enable the *6C function, allowing a value to be entered into the stage Input Location. Key in the reference offset and press the "A" key to view the offset value now located in the stage Input Location. Refer to the *6 Mode in the datalogger manual(s) for additional information on the *6C function. If changes to the datalogger program are made and the program is recompiled in the *0 Mode, all *6C entries are erased. THE REFERENCE OFFSET SHOULD BE ENTERED AFTER ALL PROGRAM CHANGES HAVE BEEN MADE. 6. ON-SITE CHECK-OUT Testing is recommended to ensure that when the float rises or falls, the correct pulse counting channel is incremented. While viewing the stage Input Location in the *6 Mode, rotate the shaft in the direction corresponding to a rise in stage. Wait for the next program execution and confirm that the reading increases. If the reading decreases, simply exchange the input leads to the pulse count channels. 7. RANGE VS. RESOLUTION If recorded data are to reflect the resolution of the encoder, consideration must be given to the datalogger output resolution as well as the reference offset. Table 7.1 shows minimum and maximum values stored in the datalogger using low and high resolution, and associated memory consumption. 2

QD1 INCREMENTAL ENCODER INTERFACE TABLE 1. Datalogger Maximum and Minimum Range Limits and Storage Efficiency for Given Output Resolution Minimum Maximum Final Memory Zero Magnitude Magnitude Locations/Data Pt. Low Resolution 0.000 ±0.001 ±6999. 1 High Resolution 0.000 ±0.00001 ±99999. 2 The resolution of the low resolution format is reduced to 3 significant digits when the first (left most) digit is 7 or greater, as shown in Table 2. TABLE 2. Format Range and Decimal Location for Datalogger Low Resolution Output Range (Absolute Value) Decimal Location 0-6.999 X.XXX 7-69.99 XX.XX 70-699.9 XXX.X 700-6999. XXXX. It may be necessary to use high resolution or an offset to maintain the desired resolution. For example, if water level is to be measured and output to the nearest 0.01 ft., the level must be less than 70 ft. for 0.01 ft. increments to be maintained in low resolution. If the water level is expected to range from 50 to 80 feet, the data could either be output in high resolution or could be offset by -20 ft., transforming the range to 30 to 60 ft. If the datalogger's storage capacity is limiting, it is best to maintain the measurement resolution with an offset and store the data in the more memory efficient low resolution format. 8. QD1 TIMING DIAGRAM Figure 1 is a simplified timing diagram of the pulses into and out of the QD1. In actual operation, the 5 V supply to the encoder is strobed which causes the encoder output (S1, S2 QD1 inputs) to be strobed. S1 and S2 inputs are shown as full square waves in Figure 1 for ease of conception. The time between transitions shown is the minimum 0.75 ms. 3

QD1 INCREMENTAL ENCODER INTERFACE FIGURE 1. QD1 Timing Diagram 4

APPENDIX A. SHAFT ENCODER CONNECTIONS AND EXAMPLE PROGRAM A.1 SHAFT ENCODER CONNECTIONS QD1 to shaft encoder connections shown below are for HANDAR's Model 436A and SYNERGETICS's Model 501A. These connections were verified in July of 1987. CSI is not responsible for subsequent changes in encoder pin configurations by the respective vendors. ENCODER QD1 (encoder side) 6 PIN CONNECTIONS TO CONNECTOR HANDAR SYNERGETICS A N/C GROUND B N/C S1 or S2 C +5 N/C D S1 or S2 GROUND E S1 or S2 S1 or S2 F GROUND N/C A.2 EXAMPLE PROGRAM The following program is an example only and is not meant to be used verbatim. Sensor calibration, input channels, and Input Locations selected must be adjusted for actual circumstances. The example goes so far as to place the calculated stage into an Input Location only. The user must program the necessary instructions to obtain the data in the form desired, and store it in Final Memory. In this example the reference offset would be keyed into Input Location 4 (STAGE) via *6C. Refer to the *6 Mode in the datalogger manual for detailed information on the *6C function. * 1 Table 1 Programs 01: 60 Sec. Execution Interval 01: P30 Z=F LOAD THE POWER SUPPLY mv 01: 5000 F LEVEL INTO LOCATION 1 02: 1 Z Loc [:mv LEVEL ] 02: P21 Analog Out ENABLE CAO 1 TO OUTPUT 01: 1 CAO Chan 5000 mv TO POWER THE QD1 02: 1 mv Loc mv LEVEL THE STEPS ABOVE ARE REQUIRED FOR 21X AND CR7 DATALOGGERS ONLY. 03: P3 Pulse Count MEASURE THE TWO PULSE 01: 2 Reps COUNT CHANNELS 02: 1 Pulse Input Chan LOCATION 2 = UP COUNT 03: 0 High frequency LOCATION 3 = DOWN COUNT 04: 2 Loc [:UP COUNT ] MULTIPLIER =.01 FOR OUTPUT 05:.01 Mult IN FEET (1 FT CIRCUMFERENCE 06: 0 Offset WHEEL,100 COUNTS/REV) 04: P33 Z=X+Y STAGE = STAGE + UP COUNT 01: 4 X Loc STAGE 02: 2 Y Loc UP COUNT 03: 4 Z Loc [:STAGE ] 05: P35 Z=X-Y STAGE = STAGE - DWN COUNT 01: 4 X Loc STAGE 02: 3 Y Loc DWN COUNT 03: 4 Z Loc [:STAGE ] 06: P End Table 1 A-1

APPENDIX A. SHAFT ENCODER CONNECTIONS AND EXAMPLE PROGRAM INPUT LOCATIONS USED: 1:mV LEVEL 2:UP COUNT 3:DWN COUNT 4:STAGE A-2

This is a blank page.

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za sales@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au info@campbellsci.com.au Campbell Scientific do Brazil Ltda. (CSB) Rua Luisa Crapsi Orsi, 15 Butantã CEP: 005543-000 São Paulo SP BRAZIL www.campbellsci.com.br suporte@campbellsci.com.br Campbell Scientific Canada Corp. (CSC) 11564-149th Street NW Edmonton, Alberta T5M 1W7 CANADA www.campbellsci.ca dataloggers@campbellsci.ca Campbell Scientific Ltd. (CSL) Campbell Park 80 Hathern Road Shepshed, Loughborough LE12 9GX UNITED KINGDOM www.campbellsci.co.uk sales@campbellsci.co.uk Campbell Scientific Ltd. (France) Miniparc du Verger - Bat. H 1, rue de Terre Neuve - Les Ulis 91967 COURTABOEUF CEDEX FRANCE www.campbellsci.fr campbell.scientific@wanadoo.fr Campbell Scientific Spain, S. L. Psg. Font 14, local 8 08013 Barcelona SPAIN www.campbellsci.es info@campbellsci.es Please visit www.campbellsci.com to obtain contact information for your local US or International representative.