How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Similar documents
Digital Flow Switch for Air/Water

Digital Flow Switch for Large Flow

100 : 1. Digital Flow Switch. PFMB Series 66 % 67% 76 % 81% 2-Color Display (Only 200 L type) Compact, Space saving

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Digital Flow Switch for Water

3-color/ 2-screen display 1

3 -color/2 -screen display

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Digital Flow Switch for Water 3 -color/2-screen display

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

PROPORTIONAL VALVES Sentronic plus

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Electromagnetic Type Digital Flow Switch

Electromagnetic Digital Flow Switch

Photoelectric Sensors E3F2

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

Electromagnetic Type Digital Flow Switch

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

APPLICATIONS. Automatic warehouse. Trasportation lines

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

02/11/2015

GC61 Digital Pressure Gauge. Operation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

Separate Thin Amplifier type. AP-V40AW Series

Cylindrical Photoelectric Sensor CY-100 SERIES

Digital Gap Checker. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air STEP 2 STEP 3

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Mechanical flow switch for On/Off control

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Photoelectrics Through-beam Type PA18C.T..., DC

APPLICATIONS. Automatic warehouse. Trasportation lines

02/11/2015

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Micro-Machined Silicon Transducers

Multifunction Digital Timer

Type AKS 4100/4100U Coaxial D14 version

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

100:1. 74 % reduction. 78 % reduction. 1 l/min. Expanded flow range. Compact, Space saving. 3-Colour Display Digital Flow Switch

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

GC30 Digital Differential Pressure Gauge Operation Manual

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

Selection matrix for electronic pressure switches

Magnetic Sensor - Incremental EHP

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Single Point Flow Monitor SW118 SW119

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Electrical connection

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

USER S MANUAL. FX2N-8AD Analog input block

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Absolute Rotary Encoder E6CP

Solid-State Digital Timer

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Digital pressure sensor PPX series

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Standard signal metering in wall-mounting case

Linear flow control with actuator IFC

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

Self--powered Time Counter

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Digital Flow Monitor PFG3#0

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

FLOMAT Electromagnetic Insertion Flowmeter

Operating Instructions

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

SMALL SIZE FLOW CONTROLLER RAPIFLOW FCM SERIES

PRINCIPLES AND APPLICATIONS

SU17 Series Fiber Optic Sensors

SIGNET 5500 Flow Monitor ENGLISH

Linear encoders without bearings incremental System for linear motion feedback

ULTRASONIC. Distance and Proximity Sensors. UFP / UPA Series. Key-Features:

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Capacitive sensor BCT5-S18-UP6X2T-H1151

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

User Manual M1 - tricolour

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Electrical connection

Self-powered Totalizer

Flow Switch. Flow Switch

Modular Lube Lubrication Systems System Controls

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Transcription:

Integrated Display Type Flow rate range 0 2 5 Symbol 0 02 03 0 Specifications ow Order PFA7 0 0 27 0l/min 5 l/min 0 00l/min 20 200l/min 0l/min Port size /8 / 3/8 /2 Model Measured fluid Detection type Flow rate measurement range Minimum setting unit Note ) Real-time flow rate Display units Accumulated flow Operating pressure range Proof pressure Pressure loss Accumulated flow range Operating temperature range Linearity Repeatability Temperature characteristics Note 2) Output specifications Switch output Analog output Indicar lights Response time ysteresis Power supply voltage Current consumption Withstand voltage Insulation resistance Noise resistance Vibration resistance Impact resistance Weight Enclosure Port size (Rc, NPT, G) 0 For Air Digital Flow Switch Series PFA Thread type Nil Rc N NPT F G Port size Flow rate (l/min) Applicable ls 00 200 0 PFA7, PFA72 PFA75 Wiring specification Nil N 3m lead wire with connecr Without lead wire Unit specification Nil With unit switching function M Fixed SI unit Note) Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Output specification Nil 27 28 67 68 Output specification NPN open collecr 2 outputs NPN open collecr output Analog output ( 5V) PNP open collecr 2 outputs PNP open collecr output Analog output ( 5V) Applicable ls PFA70 PFA7 PFA7 PFA72 PFA75 Dry air, N₂ eater type 0l/min 5 l/min 0 00l/min 20 200l/min 0l/min % of maximum flow rate l/min, CFM x 0 - ² l/min, CFM x 0 - ¹ l, ft³ x 0 - ¹ 0 0.5MPa.0MPa 3kPa (at l/min) 3kPa (at 00l/min) 0kPa (at 200l/min) 30kPa (at 0l/min) 0 999999l 0 C (with no condensation) ±5% F.S. or less ±% F.S. or less ±2% F.S. or less ±3% F.S. or less (5 35 C), ±5% F.S. or less (0 C) NPN open collecr Maximum load current: 80mA; Internal voltage drop: V or less (with load current of 80mA) Maximum applied voltage: 30V PNP open collecr Maximum load current: 80mA Internal voltage drop:.5v or less (with load current of 80mA) Output voltage: 5V impedance: 00kΩ or more 27, 67: Lights up when output is : Green; : Red sec. or less ysteresis : Variable (can be set from 0), Window comparar : 3-digit fixed Note 3) 2VDC (ripple ±0% or less) ma or less 000VAC for min. between external terminal and case MΩ (0VDC) between external terminal and case 000Vp-p, Pulse width µs, Rise time ns 0 0z at whichever is smaller:.5mm amplitude or 98m/s² acceleration, in X, Y, Z directions for 2 hrs. each 90m/s² in X, Y, Z directions 3 times each 2g (without lead wire) /8, / 27, 67: Lights up when output is : Green; : Red 28, 68: Lights up when output is : Green; : None Note ) For digital flow switch with unit switching function. (Fixed SI unit [l/min or l] will be set for switch types without the unit switching function.) Note 2) The output functions operate only for the real-time flow rate display, and do not operate for the accumulated flow display. Note 3) Window comparar Since hysteresis will reach 3 digits, keep P and P2 apart by 7 digits or more. The minimum setting unit is digit. (Refer the table above.) Flow rate units measured under the following conditions: 0 C and 0.3kPa. IP65 60mA or less 290g (without lead wire) 70mA or less 3/8 /2

Series PFA Sensor Unit Construction PFA, PFA5 PFA5, PFA52, PFA55 Parts list No. 2 3 5 Description Attachment Seal Mesh Body Sensor Material ADC NBR Stainless steel Operating Unit Descriptions Parts list No. Description Attachment 2 Seal 3 Spacer Mesh 5 Body 6 Sensor Material ADC NBR Stainless steel RE Butns Press the and butns simultaneously activate the RE function. This clears the unit when an abnormality occurs and resets the accumulated flow display "0". Output () Indicar: Green Lights up when is. Blinks when an overcurrent error occurs on. Output () Indicar: Red U P DOWN LED Display Displays the real-time flow rate, accumulated flow, and set value. The mark blinks when the accumulated flow is being measured. UP Butn ( Butn) Use this butn increase a set value. Butn ( Butn) Use this butn change a set value or any of the s. Lights up when is. Blinks when an overcurrent error occurs on. Error Correction DOWN Butn ( Butn) Use this butn decrease a set value. Take the following corrective solutions when errors occur. LED display Contents Solution A current of more than 80mA is flowing. Check the load and wiring for. A current of more than 80mA is flowing. Check the load and wiring for. The setting data has changed for whatever reasons. The flow rate is over the flow rate measurement range (for air only). Perform the RE operation, and reset all data again. Reduce the flow rate until it is within the flow rate measurement range, using an adjustment valve.

For Air Digital Flow Switch Series PFA Flow Rate Setting Setting procedure Manual flow rate setting Key lock Initial setting Set the flow rate that performs switch output. Even if butn is pressed during operation, will not be switched. Initial setting: Sets the display (real-time flow rate/accumulated flow), unit, and output (non-inverted/inverted). Au preset Set the flow rate aumatically. Manual flow rate setting Data that is aumatically set with the au preset can be calibrated. Normal operation Displays the flow rate and performs switch operation. Initial setting Note) Operation is the same for the integrated display type and the remote type (display unit).. Initial Setting Mode 2. Selection of the Display Mode 3. Selection of Display Units Press the butn. Press the butn. Press the butn and hold for second or longer. Release the butn once the display changes from or. Set the display. Use the butn switch. : Display for real-time flow rate : Display for accumulated flow For -M (fixed SI unit) Set the display unit. Note ) Use the and butns switch. Unit number (Refer Table.). Selection of Output Mode 5. Selection of Output Mode Press the butn. Press the butn complete the setting. Set the output for. Use the butn switch the output for. : Non-inverted output : Inverted output (Refer Table 2.) Set the output for. Use the butn switch the output for. : Non-inverted output : Inverted output Note ) Table Table 2 For air Display CFM = ft³/min Real-time flow rate l/min CFM x 0 - ², CFM x 0 - ¹ For water Display Real-time flow rate l/min GPM Accumulated flow l ft³ x 0 - ¹ Accumulated flow l gal (US) GPM = gal (US)/min Note ) For digital flow switch with unit switching function (Fixed SI unit [l/min or l] will be set for the type without the unit switching function.) Note 2) Output is set inverted output at the facry before shipment. is the same. "P" Output "n" Note 2) Output type YES NO YES NO P_2 P_ P_ P_2 n_2 n_ n_ n_2 ysteresis (fixed hysteresis) = 3 digits Window comparar ysteresis (fixed hysteresis) = 3 digits Window comparar 5

Series PFA Flow Rate Setting Flow rate setting (manual) Set Value Input. Mode (Manual) Manual Mode 2. Setting Setting the first () 3. Value for OUT Press the butn. Press the butn. (Refer Table 2 for the relationship between each value and the switch output.) Press the butn when displayed. is Set the first () value for. butn: Increases the set value. butn: Decreases the set value. Setting the second (2). Value for OUT Setting the first () 5. Value for Setting the second (2) 6. Value for OUT 2 Press the butn. Press the butn. Press the butn complete the setting. Set the second (2) value for. butn: Increases the set value. butn: Decreases the set value. Set the first () value for. butn: Increases the set value. butn: Decreases the set value. Set the second (2) value for. butn: Increases the set value. butn: Decreases the set value. Flow rate setting (au preset) Set value Input. Mode Setting in the Au 2. Preset Mode Au Preset 3. Preparations Press the butn. Press the butn, and release it as soon as is displayed.. Au Preset Press the butn switch the display. Au Preset 5. Preparations This prepares equipment for the setting. Flow for switch output will start. When the setting is not required, press the and butns simultaneously in this. 6. Au Preset Press the butn. Press the butn complete the setting. When the butn is pressed at this point, the optimum value will calculated and input set aumatically. and the input value will be alternately displayed. Prepares equipment for the OUT 2 setting. When the setting is not required, press the and butns simultaneously in this. When the butn is pressed at this point, the optimum value will be calculated and input aumatically. and the input value will be alternately displayed. point (C, C) point ysteresis (3 digits) 6 point = C, C point = C 3 digits, C 3 digits, ( digit is the minimum setting unit.)

For Air Digital Flow Switch Series PFA Other functions Accumulated flow function Start of Accumulation Key lock Start of Key Lock Function Prevents incorrect operations of the butn control. Start accumulation. Press the butn while pressing the butn at the same time. The mark blinks and accumulation begins. Up (l) of flow can be accumulated, but normally only the lower 3 digits are displayed. Press the butn verify the upper 3 digits. Spping Accumulation Press the butn and hold it for 3 seconds or longer. Release the butn when the display changes from and displays. Release of Key Lock Function Use the butn display. Press the butn complete the setting. Press the butn verify the real-time flow rate during accumulation. Press the butn while pressing the butn at the same time. The display fixes upon the current accumulated value and sps. To start further accumulation from this point, press the butn while pressing the butn at the same time. Press the and butns simultaneously and hold for 2 seconds or longer clear the display. Press the butn and hold it for 3 seconds or longer. Release the butn when is displayed. Use the butn display. Press the butn complete the setting. Switching the flow rate range of the remote type (for air) Switching Flow Rate Range Press the butn and hold it for seconds or longer. the values shown in Table 3 will be displayed. Use the butn select the desired flow rate range. Press the butn complete the setting. Table 3 Display Flow rate range 0l/min 5 l/min 0 00l/min 20 200l/min 0l/min Applicable l For PFA30 For PFA3 7

Series PFA Dimensions: Integrated Display Type for Air Internal circuits and wiring examples 5 -ø.5 FLOW SWITC FOR AIR 98 82 60 0 UP DOWN (.5) 3 2-Port size 67 58 2 7 6.6 Main circuit Main circuit LED Red PFA7--27(-M) LED Red PFA7--67(-M) 2VDC 2VDC 2 2-ø3. 3 Main circuit Main circuit 6 88 6 23.6 Connecr pin numbers 3 FLOW SWITC U P 5 3 FOR AIR DOWN 2 -ø.5 0 (.5) 2-Port size 30 Pin no. 2 3 Pin description DC() /Analog output DC() 73 Analog output PFA7--28(-M) Analog output 2VDC 2VDC PFA7--68(-M) 8