Submittal. Downflow Two Stage Condensing Gas Fired Furnace 120,000 BTUH S9V2D120D5-SUB-1-EN. March 2016 S9V2D120D5PSAA TAG:

Similar documents
Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

Ultra Quiet Series Electric Air Handler

80G1 PRODUCT SPECIFICATIONS GAS FURNACE SINGLE STAGE CONFIGURATIONS HEAT EXCHANGER DESIGN CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

A801D PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE INSTALLATION FEATURES

Installation Operation Maintenance

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace

Split System Air Conditioner

Twin City Fan & Blower

Series 8800 Radial Tip Fans Design 8812

Series 7600 Centrifugal Airfoil Fan

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MODULAR PLENUM FANS MPLFN MPLFS MPLQN MPLQS CATALOG 495 APRIL 2013

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

Features. Specifications. Finish. Notes

CENTRIFAN IN-LINE CENTRIFUGAL FAN

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)

DHK DHK-NW MEDIUM PRESSURE FRP CENTRIFUGAL FAN HIGH PRESSURE FRP CENTRIFUGAL FAN

Bulletin IND05 INDUSTRACON

XPert Nano Enclosures

XPert Filtered Balance Systems

Modular Lube Lubrication Systems System Controls

Küba comfort DP. Draught-free ventilation and extremely quiet operation

WCHE BTU/Hr Watts

T BTU/Hr Watts

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

WCHE BTU/Hr Watts

WCHE BTU/Hr Watts

Part-Turn Electric Multi-Turn Electric

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST FANS. Model TVIFE

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options

T BTU/Hr Watts

T BTU/Hr Watts

KRF EMC Filters Installation, Operation and Maintenance Manual

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

P Output Ratings. Dimensions and Weights. Prime Rating

Series 7400 Vaneaxial Fans Designs 7410, 7412, 7413 & 7416

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone:

Turning Air Into Solutions. BACKWARD CURVED HIGH PRESSURE FANS MODEL BCS

Plenum Fans Your Clean Air Source!

ULTRALOW TEMPERATURE FREEZERS -86 C

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

Product Data Sheet 4656 EZ

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

P Output Ratings. Dimensions and Weights. Prime Rating

CME500 SERVICE PARTS

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P1350P1/P1500E1 50Hz

Agilent High Capacity RV Pumps & Roots Pumping Systems

Electromagnetic Block Valves Direct Acting

XR47-24 Models 24 W/ F (43 W/ C)

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Okta 1000, Roots pump without motor

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate V3. Coolant systems are warranted for 1 year, parts and labor.

Flygt Submersible Motor Cables

Linear flow controls VFC Linear flow controls with actuator IFC

Axial Fan, 4 in, Bulletin D85 (Hoffman Thermal Management

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Colour Explosion Proof Video Camera USER MANUAL VID-C

PARTS LIST FOR CM-1250-A/C 1.5 HP

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Linear flow control with actuator IFC

New Products. New Possibilities.

GENESIS Indoor Air Conditioners

Inter-Temp. Medium Profile Unit Cooler Publication No December, Medium to Large Walk Ins. Cooler & Freezer Applications

WLB SERIES HID Lighting for Hose Down Applications

Product Data Sheet 4656 ZW

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

Selecting Cables for Power over Ethernet

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Dry Type Transformers. Section 10. BuyLog Catalog 10-1

XR47-24 Models 24 W/ F (43 W/ C)

Safety Codes Council Conference Banff C Panel Discussion

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

ROHDE GAS AND RAKU A BURNING PASSION FOR THE BEST POSSIBLE RESULTS. Photo Patricia Schichl

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

IndyGo Facility Upgrades Project 35671EE

Transcription:

Submittal Downflow Two Stage Condensing Gas Fired Furnace 120,000 BTUH Downflow Only S9V2D120D5PSAA Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2016 S9V2D120D5-SUB-1-EN

Outline Drawings Downfl ow Furnace D Size Cabinet 2 S9V2D120D5-SUB-1-EN

Product Specification MODEL S9V2D120D5PSAA MODEL S9V2D120D5PSAA TYPE Downflow Type Fired 409 Stainless Steel RATINGS (a) 1st Stage Input BTUH (ICS) 78,000 1st Stage Capacity BTUH 75,660 2nd Stage Input BTUH 120,000 2nd Stage Capacity BTUH (ICS) (b) (c) 116,400 Unfired 29 4C Stainless Steel Gauge (Fired) 20 ORIFICES Main Nat. Gas Qty. Drill Size 6-45 LP Gas Qty. Drill Size 6-56 1st Stage Temp. Rise (Min.-Max.) 35-65 GAS VALVE Redundant - Two Stage 2nd Stage Temp. Rise (Min.-Max.) 40-70 AFUE (%) 96.0 BLOWER DRIVE DIRECT Diameter Width (In.) 11 X 10 No. Used 1 Speeds (No.) Variable CFM vs. in. w.g. See Fan Performance Table Motor HP 1 RPM Variable Volts/Ph/Hz 120 / 1 / 60 FLA 10.5 COMBUSTION FAN Type Centrifugal Drive No. Speeds Direct - 2 Motor HP RPM 3300/2600 Volts/Ph/Hz 120 / 1 / 60 FLA 0.66 FILTER Furnished? Type recommended Hi Vel. (No.-Size-Thk.) VENT PIPE DIAMETER Min (in.) (d) (e) No High Velocity 2 16x20 1 in. 3 Round PILOT SAFETY DEVICE Type BURNERS Type 120 V SiNi Igniter Multiport Inshot Number 6 POWER CONN. V/Ph/Hz (f) 120 / 1 / 60 Ampacity (In Amps) 13.9 Max. Overcurrent Protection (Amps) 15 PIPE CONN. SIZE (in.) 1/2 DIMENSIONS H x W x D Uncrated (In.) 34 x 24-1/2 x 28 3/4 Crated (In.) 35-1/2 x 26-1/2 x 30-7/8 WEIGHT Shipping (Lbs.)/Net (Lbs.) 167/156 (a) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. (b) Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3. (c) Based on U.S. government standard tests. (d) Refer to the Vent Length Table in the Installer's Guide. (e) All S9V2 furnace models have a vent outlet diameter that equals 2 in. (f) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. HEAT EXCHANGER S9V2D120D5-SUB-1-EN 3

Heating and Airflow Tables S9V2D120D5PSAA Table 1. S9V2D120D5PSAA Heating Airflow S9V2D120D5PSAA Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter 1st Stage Capacity = 75,660 2nd Stage Capacity = 116,400 Heating Airflow Setting Target Airflow External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 1234 1240 1246 1252 1258 Low 1160 Temp. Rise 56 56 56 55 55 Watts 137 198 258 319 380 CFM 1305 1311 1318 1325 1332 Medium Low 1332 Temp. Rise 53 53 53 52 52 Heating 1st Stage Watts 158 221 284 347 410 CFM 1324 1510 1697 1884 2070 Medium 1404 Temp. Rise 53 46 39 32 25 Watts 179 246 313 380 447 CFM 1598 1484 1371 1257 1144 High (a) 1620 Temp. Rise 44 47 49 52 54 Watts 266 316 366 416 466 CFM 1687 1673 1659 1645 1631 Low 1750 Temp. Rise 63 64 64 65 65 Watts 327 407 487 568 648 CFM 1788 1771 1754 1738 1721 Medium Low 1850 Temp. Rise 60 60 61 61 62 Heating 2nd Stage Watts 380 464 549 633 718 CFM 1891 1862 1833 1803 1774 Medium 1950 Temp. Rise 56 57 58 60 61 Watts 424 524 624 724 824 CFM 2080 2100 2120 2140 2160 High (a) 2250 Temp. Rise 51 51 51 51 51 Watts 708 768 828 888 948 (a) Factory Setting. 4 S9V2D120D5-SUB-1-EN

Heating and Airflow Tables 9V2D120U5PSAA / 9V2D120D5PSAA Table 2. 9V2D120U5PSAA / 9V2D120D5PSAA Airflow S9V2D120U5PSAA / 9V2D120D5PSAA Furnace Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter Unit Outdoor Airflow Setting (CFM/ ton) External Static Pressure 0.1 0.3 0.5 0.7 0.9 450 CFM 1575 1575 1575 1575 1575 Watts 248 316 387 461 537 420 CFM 1470 1470 1470 1470 1470 Watts 206 270 337 407 479 400 CFM 1400 1400 1400 1400 1400 Watts 181 243 307 374 443 3.5 Ton 370 350 CFM 1295 1295 1295 1295 1295 Watts 148 205 265 328 393 CFM 1225 1225 1225 1225 1225 Watts 128 182 240 300 363 330 CFM 1155 1155 1155 1155 1155 Watts 111 162 217 274 335 310 CFM 1085 1085 1085 1085 1085 Watts 95 143 195 250 309 290 CFM 1015 1015 1015 1015 1015 Watts 80 126 176 228 285 450 CFM 1800 1800 1800 1800 1800 Watts 356 433 514 597 682 420 CFM 1680 1680 1680 1680 1680 Watts 295 368 443 521 601 400 CFM 1600 1600 1600 1600 1600 Watts 258 328 400 475 552 4.0 Ton 370 350 CFM 1480 1480 1480 1480 1480 Watts 210 274 342 412 484 CFM 1400 1400 1400 1400 1400 Watts 181 243 307 374 443 330 CFM 1320 1320 1320 1320 1320 Watts 155 213 274 338 405 310 CFM 1240 1240 1240 1240 1240 Watts 132 187 245 306 369 290 CFM 1160 1160 1160 1160 1160 Watts 112 163 218 276 337 S9V2D120D5-SUB-1-EN 5

Heating and Airflow Tables Table 2. 9V2D120U5PSAA / 9V2D120D5PSAA Airflow (continued) S9V2D120U5PSAA / 9V2D120D5PSAA Furnace Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter Unit Outdoor Airflow Setting (CFM/ ton) External Static Pressure 0.1 0.3 0.5 0.7 0.9 450 CFM 2025 2025 2025 2025 2025 Watts 492 579 669 761 855 420 CFM 1890 1890 1890 1890 1890 Watts 406 488 572 659 747 400 CFM 1800 1800 1800 1800 1800 Watts 356 433 514 597 682 4.5 Ton 370 350 CFM 1665 1665 1665 1665 1665 Watts 288 360 435 512 592 CFM 1575 1575 1575 1575 1575 Watts 248 316 387 461 537 330 CFM 1485 1485 1485 1485 1485 Watts 212 277 344 414 487 310 CFM 1395 1395 1395 1395 1395 Watts 180 241 305 371 440 290 CFM 1305 1305 1305 1305 1305 Watts 151 208 269 332 398 450 CFM 2250 2250 2250 2188 2103 Watts 659 756 856 900 922 420 CFM 2100 2100 2100 2100 2100 Watts 544 634 728 823 920 400 CFM 2000 2000 2000 2000 2000 Watts 475 561 650 741 834 5.0 Ton (a) 370 CFM 1850 1850 1850 1850 1850 Watts 383 463 546 631 717 350 CFM 1750 1750 1750 1750 1750 (a) Watts 329 405 484 564 647 330 310 290 CFM 1650 1650 1650 1650 1650 Watts 281 352 427 503 582 CFM 1550 1550 1550 1550 1550 Watts 237 305 375 448 523 CFM 1450 1450 1450 1450 1450 Watts 199 262 328 397 468 (a) Factory Setting 6 S9V2D120D5-SUB-1-EN

General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable, cycle tested, heavy gauge tubular stainless steel primary heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains dry contacts for EAC and HUM. ENERGY EFFICIENT OPERATION Furnace is certified by the manufacturer to leak 1% or less of nominal air conditioning CFM delivered when pressurized to.5" water column with all inlets, outlets, and drains sealed. AIR DELIVERY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SECONDARY HEAT EXCHANGER The S-Series furnace has a special type 29-4C stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. STYLING Heavy gauge steel and "wrap-around" cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES AND GENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. S9V2D120D5-SUB-1-EN 7

Features and Benefits 96.0% AFUE ACROSS ALL MODELS Meets utility rebates Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34 INCH TALL Lighter, easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high-efficiency coils No knockouts 3 WAY MULTI-POISE / DEDICATED DOWNFLOW 9 SKU s Upflow / Horizontal Left / Horizontal Right 7 SKU s Downflow Added application flexibility and reduction in specification errors AIRFLOW At least 400 CFM/ton at 0.5 in. H 2 0 external static pressure; setup airflow options down to 290 CFM/ton REGULATORY All models are air tight; 1% or less air leakage as per ASHRAE 193 Open vestibule design provides a full 34 high open vestibule DIMENSIONS Widths are industry standard: 17.5, 21, and 24.5 Depth remains approximately 28 Cabinet will be compatible with industry standard coils, as well as, other accessories INTEGRATED FURNACE CONTROL Setup / Status / Diagnostics / Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR STAINLESS STEEL PRIMARY HEAT EXCHANGER 29 4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Stainless steel is a more durable, corrosive-resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VORTICA II BLOWER, DESIGNED EXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable, easy to clean, two piece housing Single piece belly band/ motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise THREE WAY MULTI-POISE (UPFLOW, HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED DOWNFLOW Easier to specify Shipped ready to install (no kits required) Every model has at least two venting options When in horizontal, trap extends only about 2 Barbed fitting on trap at hose connection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths; 2 pipe can be used up to 100K 8 S9V2D120D5-SUB-1-EN

Notes The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.irco.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 2016 Trane S9V2D120D5-SUB-1-EN 03 Mar 2016 Supersedes (New)