TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Similar documents
Matt Dann Cultural Centre

RPAC REDLANDS PERFORMING ARTS CENTRE

2017 TECHNICAL SPECIFICATIONS

CENTRE FOR PERFORMING ARTS

THE STREET THEATRE. Technical Specifications

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Latrobe Performing Arts Centre

RIVERSIDE THEATRES Corner Church St & Market St Parramatta NSW PO Box 3636 Parramatta NSW

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Dr JOHN GALLAGHER CONCERT CHAMBER

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

John Leslie Theatre. Technical Specifications. Updated July 2018

RIVERSIDE THEATRES Corner Church St & Market St Parramatta NSW PO Box 3636 Parramatta NSW

Esso BHP Billiton Wellington Entertainment Centre

Technical Specifications

DEREHAM MEMORIAL HALL

New Theatre Royal Lincoln Technical Information

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

INFORMATION FOR VISITING COMPANIES

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Technical Specification Pavilion Dance

Visy Theatre technical information and general specifications 2019

Main House Technical Specification

The Haymarket Basingstoke Technical Specifications

Queensland Performing Arts Centre

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

MONASH University Academy of Performing Arts

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Monash Academy of Performing Arts

Monash University Academy of Performing Arts

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Hopgood Theatre NOARLUNGA CENTRE

Technical Specifications and Inventory Spring 2018

JERWOOD VANBRUGH THEATRE

Don Russell Performing Arts Centre

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Access to back stage is off Fletcher St on the eastern side of the building

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

HIRE AND TECHNICAL INFORMATION

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Theatre Technical Specifications

CHELSEA THEATRE. Technical Specifications

Technical Data Sheet

Technical Specifications

ISLAND HALL TECHNICAL INFORMATION

Mildura Arts Centre. Mildura Arts Centre Theatre. Technical Specifications. Updated 23/6/06

Hopgood Theatre NOARLUNGA CENTRE

Orange Civic Theatre

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

The Mannie Manim Technical Specifications

Technical Specification Ardhowen Theatre

Technical Specifications

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

BECKETT THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

TECHNICAL SPECIFICATIONS

RIVERSIDE THEATRES Corner Church St & Market St Parramatta NSW PO Box 3636 Parramatta NSW

The Breen Center for the Performing Arts Saint Ignatius High School

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Specification for the Alley Theatre, Strabane

Technical Specification

Technical Pack. Attenborough Arts Centre

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Theatre Technical Specification

Facility Information

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Sandusky State Theatre Technical Specifications

Technical Specification. Updated: April 2016

Technical Services and Specification

Yan Yean Theatre Technical Specifications

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

D A R E B I N A R T S & E N T E R T A I N M E N T C E N T R E

Shouson Theatre Venue Specifications (updated Jan 2017)

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Powerhouse Theatre technical information and general specifications 2017

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Bathurst Memorial Entertainment Centre Theatre Technical Specifications 2014

Technical Information

Technical Director of Production Andrew Quick Ext 252

The Georgian Theatre Royal Technical Information For Visiting Companies

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Dinkelspiel Auditorium - Technical Specifications

Theatre Technical Specifications

Main Stage Technical Specs - Hall #2

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Technical Specifications Updated 01/10/2017. Stage

Jane Mallet Theatre Technical Specifications

THEATRE Technical Specifications

Technical Specifications Nov 2016

Transcription:

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE - 2014 Standard Lighting Rig is a four (4) colour wash onstage and five (5) colour wash Front of House Standard Flying Rig is attached to this document and is reinstated during Bump Out at the discretion of the Technical Co-Ordinator Our staff operates all equipment in the Riverside Theatre. If you wish to operate our equipment, staff of the theatre must be employed to supervise its operation. Technical staff supplied for the performance as stated in the Hiring Contract is (1) Lighting Operator, (1) Sound Operator, (1) Mechanist/Flyman and one (1) Stage Door Security. The Management of the Theatre shall not be held responsible for any equipment, which is not available to the hirer due to electrical or mechanical failure, or any other circumstance beyond its control. A copy of the venue plans are available from our website under venues: www.riversideparramatta.com.au If further information is required please contact: Sean Clarke Technical Co-ordinator (02) 8839 3390 Mitchell Kroll Technical Team Leader (02) 8839 3361 technicalsupervisor_riverside@parracity.nsw.gov.au Phone (02) 8839 3361 Fax (02) 9683 3267 STAGE DIMENSIONS Proscenium Arch: 12m wide x 7.4m High Stage Working Depth: 9m to Ground Row Lighting Stage Working Depth: 10.8m to last fly line Stage Depth: 12m to Back Wall Stage Height: 18.8m to Grid Width: Centre to OP: 15m Width: Centre to PS: 10.4m Total 25.4m Stage Design Load: 700kg/m.sq Side Stage Design Load: 500kg/m.sq Fly Lines: 41 Fly Bars X 15.4m Long (48mm OD) Line Load: 400kgs Fly Line Travel: 18 Metres Setting Line to Forestage: 500mm Fly Lines Operated from Prompt Side - Stage Level Loading Dock Access O.P 3100 Wide x 3600 High

STAGE DRAPERY 5 Pairs Legs 9000 x 4000mm Flat 5 Borders 4000 x 15400mm Flat 1 Traveler Curtain - 2 Piece 9000 x 8300mm 1 House Curtain Electric French action or Flown 1 Rear Black 9000 x 15400mm Flat 1 Cyclorama 8500 x 15400mm Please note: The stage floor is flat floor surface with a Masonite skin over a parquetry floor it is sprung. Fixing to the floor is permitted any work done to the floor is repaired at the hirer s cost. The stage floor is painted black and there is no permission to paint the floor, a false floor must be laid. ORCHESTRA PIT / STAGE EXTENSIONS: The front two rows of seating can be removed to provide an Orchestra Pit or set at stage level to give a 2m extension at centre curving to zero at the sides. The orchestra pit can accommodate up to 25 musicians plus a grand piano. 17 music stands with sconces available, plus conductor s and piano stands with sconces. LIGHTING Lighting Console: 1 x ETC Gio Console with wing faders and remote focus device LAMP LIST: 20 x 12/28 1k Selecon Pacific M Size Gobo 33 x 23/50 1k Selecon Pacific B Size Gobo 36 x 1.2Kw Selecon Rama Fresnels with Barn Doors 28 x 18-34 600w Acclaim Axial 16 x 24-44 600w Acclaim Axial 20 x 650w Linea Sintesi Fresnels 5 x 4way CCT 1kw Flood Unit 5 x 4way Horizon 800w Ground Row Unit 32 x MFL Par 64 (110v) These lamps are used in the standard rig, any changes made to the rig and must be restored at the conclusion of the venue hire at the hirer s cost. PATCH / DIMMER INFORMATION 3 Bridges FOH 30 Circuits per Bridge 2 Balconies 10 Circuits per Balcony 4 Main LX Bars Onstage 30 Circuits each 2 Sub LX Bars Onstage 12 switchable circuits 240v or 110v 40 Floor Circuits 20 per side (20amp outlets) 20 Box Boom Circuits 10 per side 8 Lighting Ladders 4 per side 4 Circuits to each 1 x Jands HP Dimmer Rack (USPS on Floor) 1 x Jands HP Dimmer Rack (PS Fly Floor) 1 x Jands HP Dimmer Rack (OP Fly Floor) 120 x Strand 5kw Dimmers (Dimmer Room) 10 x 2.4m Stage Booms (Subject to availability) Dimmer Control DMX 512 (2 streams)

FOLLOWSPOTS 2 X Colortran Xebec 2k Follow Spots are available (Riverside technicians operate these followspots as they are located in the roof area.) SOUND SYSTEM: A genuine Left, Centre, Right processor controlled system plus 4 fold back/effects sends Mixer 1 x Soundcraft MH4 40 Mono/4 Stereo Channel Mixer with 8 VCA and 16 Groups Speakers Alcons Line Array @ Proscenium Arch (Centre) (8 x Alcons LR14, 3 x LR14B Subs, 2 x Alcon Deep Subs) 6 x BOSE MA12 Array Side Speakers (Left and Right) 2 x BOSE Acoustic Wave Cannons (Centre) 2 x BOSE 502B Subs (Left and Right) 6 x BOSE M32SE - Front Fill (Centre) 4 x Peavey Wedges for F/back/Effects (Additional available) Playback Riverside has a number of commercial quality playback devices including: CD and Minidisc players. Amplification 3 x ALC2 Alcons Amps with DDP 2 x ALC4 Alcons Amps with DDP 1 x PC 2002 Yamaha Amplifier (Cannons) 2 x Crown 602 (BOSE MA12s Left and Right) 1 x Crown CE 2000 (BOSE 502B Left and Right) 1 x Yamaha PC2002M (Fold Back/Effects 1&2) 1 Crown 402 (Fold Back/Effects 3&4) Creative Audio A2000 (M32SE Front Fill) 1 x DBX 481 System processor 1 x BOSE WSC1 System Processor OTHER EQUIPMENT: A variety of Vocal, Instrument and Hanging Mics as well as Hand held, Lavaliere, lapel and production style headset radio microphones are also available. (2 radio mics included in full rental 4 additional for small fee. Batteries at cost) Please discuss your requirements with the Technical Team Leader technicalsupervisor_riverside@parracity.nsw.gov.au PROCESSORS / GRAPHICS: 2 x Lexicon MP1 Effects Units 2 x Yamaha Q1027 Graphic Equalizers Up to 16 Radio Mics are available for hire (2 included in full rental, additional units for small fee. Batteries at cost) 4 x Yamaha Q 1027 - Graphic Equalizers (Fold Back/Effects) 1 x Yamaha Q2031 Graphic Equalizer (Radio Group) 2 x Compressor Limiters DBX 106X Paging: - All Dressing Rooms Talkback Cable Headsets Available throughout Venue

AUDIO VISUAL: 1 x Sony FX-52 Data Projector (Wide, Short and Long Throw Lens also available) 1 x Sanyo PDG-DHT100L True HD Single Chip DLP Projector (Long and Short Throw Lens Available) 1 x Kramer VP727 Analogue Switcher 1 x Kramer VP747 In-CTRL Dual Scaler Seamless Switcher (inc: Audio Xfade and Remote Panel) 1 x 16 x 12 Front and Rear Projection Screen (4:3) 1 x 8m x 5.4m Front Projection Screen (16:9) 2 x Panasonic DMP-BDT300 Full HD 3D Blu Ray Player 1 x Panasonic DMP-BD45 Full HD Blu Ray Player with 5.1 Decoding 2 x 42 LCD Flat Screen TV 1 x Cannon HD Video Camera and Tripod 1 x Presenters Mouse 1 x Cue Light System 1 x 16 x 12 Front and Rear Projection Screen (4:3) 1 x 8m x 5.4m Front Projection Screen (16:9) A variety of other Screens are available Additional charges are associated with the use of the Audio Visual Equipment. This equipment is shared throughout all the venues of the Riverside Theatres and is subject to availability. This equipment below is shared amongst all of the theatre spaces and is subject to availability. The Riverside Theatres film screen program takes precedence over the use of this equipment. GENERAL EQUIPMENT The following list of accessories is available for your use. This equipment is shared throughout the venues of the Riverside Theatres and is subject to availability. LIGHTING ACCESSORIES: 38 x Boom Arms 10 x 2.4m Lighting Boom Stands 4 x 2.4m High Floor Stands 2 x Unique Hazers 1 x Smoke Machine 1 x Strand 520i Lighting Console (300 Channels) STAGING ACCESSORIES 15 x Staging Risers (300mm, 600mm, 900mm) 5 x 15m Rolls of Tarkett Prostage portable stages in various sizes up to 12m x 3m There is additional hire and labour cost in the setup up of the tarkette and prostage. ORCHESTRA ACCESSORIES 17 Music Stands with lights 1 x Conductors Music Stand and Podium 2 x Concert Style Timpani Prostage Choir Rostra 10m x 4m (5 levels) There is additional hire and labour cost in the setup up of the choir risers

INSTRUMENTS Yamaha C5 6 7 Grand Piano 2 x Concert Style Timpani The piano has a hire and tuning charge, please contact the Technical Team Leader if you wish to use this instrument for your production. DRESSING ROOMS: Dressing Room One Stage Level 30 Children or 16 Adults Dressing Room Two Stage Level 30 Children or 16 Adults Dressing Room Three Upper Level 20 Children (If Available) Dressing Room Four Upper Level 6 Children or 3 Adults. (If Available) All dressing rooms contain illuminated mirrors, clothing racks, toilets and showers. As per hire agreement additional Dressing Room facilities may be allocated by the Technical Team Leader LAUNDRY FACILITIES: 2 x Industrial Washing Machines 2 x Industrial Dryers (Tumble) 1 x Upright Dryer GREENROOM A Greenroom is located upstairs between dressing rooms 4 and 5. There is boiling water, chilled (or room temperature) filtered water, a microwave, comfy lounges, dining table and visiting companies fridge available. The Greenroom is a shared space for all visiting companies and crew. Soft drink and confectionary vending machines are located in the courtyard outside the exit doors near the laundry. PARKING SIX (6) parking places only are available for Riverside cast and visiting crew. Notification of the drivers names, vehicle type and registration must be given at least 1 week in advance of the company s arrival or parking may not be available. The nearest parking station is Erby Place, off Phillip Street, a 5 minutes easy walk from the theatre. BACKSTAGE ACCESS: All cast and crew MUST enter and exit via Stage Door which is located off the car park near the corner of Market and Marsden Streets. Stage Door s telephone number is (02) 8839 3360. PLEASE NOTE A FULL LIST OF YOUR COMPANY INVOLVED IN YOUR PRODUCTION NEEDS TO BE EMAILED IN AN EXCEL SPREADSHEET IN ALPHABETICAL ORDER BY SURNAME.

ALL PRODUCTION INFORMATION SHOULD BE EMAILED TO THE ADDRESS BELOW NO LATER THAN 6 WEEKS FROM YOUR PRODUCTION. PLEASE PUT YOUR PRODUCTION NAME IN THE SUBJECT HEADING. We look forward to working with you to present your production and trust that your time with us will be enjoyable and rewarding we trust we will be seeing you again in the future. Sean Clarke Technical Co-Ordinator Mitchell Kroll Technical Team Leader technicalsupervisor_riverside@parracity.nsw.gov.au

Fly Line Allocation STANDARD HANGING PLOT Measurement taken from Setting Line (Pros Wall) Please note any movement from the Standard Hanging Plot must be returned during Bump Out. Line Distance Height Description Line Distance Height Description G1 400 Pelmet BDR HC 650 House Curtain 1 900 10.5m Border 1 31 5400 Half Stage Black 2 1050 Legs 1 @ 5.5m 32 5550 NOT INSTALLED 3 1200 NOT INSTALLED 33 5700 Legs 3 @ 5.5m 4 1350 8.3m LX 1 34 5850 NOT INSTALLED 5 1500 NOT INSTALLED 35 6000 8.8m LX 3 6 1650 36 6150 7 1800 16:9 FP Screen 37 6300 8 1950 38 6450 9 2100 NOT INSTALLED 39 6600 10 2250 40 6750 11 2400 NOT INSTALLED 41 6900 12 2550 42 7050 13 2700 NOT INSTALLED 43 7200 11.3m Border 4 14 2850 11.0m Border 2 44 7350 NOT INSTALLED 15 3000 NOT INSTALLED 45 7500 Legs 4 @ 5.5m 16 3150 Legs 2 @ 5.5m 46 7650 NOT INSTALLED 17 3300 47 7800 8.5m LX 3a 18 3450 8.4m Lx 2 48 7950 NOT INSTALLED 19 3600 49 8100 NOT INSTALLED 20 3750 50 8250 NOT INSTALLED 21 3900 NOT INSTALLED 51 8400 11.0m Border 5 22 4050 NOT INSTALLED 52 8550 NOT INSTALLED 23 4200 53 8700 10.0m LX 4 24 4350 NOT INSTALLED 54 8850 NOT INSTALLED 25 4500 10.6m Border 3 55 9000 Legs 5 @ 5.5m 26 4650 NOT INSTALLED 56 9150 NOT INSTALLED 27 4800 57 9300 28 4950 NOT INSTALLED 58 9450 NOT INSTALLED 29 5100 7.5m LX 2a 59 9600 30 5250 NOT INSTALLED 60 9750 61 9900 62 10050 63 10200 Full Stage Black Notes: LX Bar height is measured from the batten not the lower bar. 64 10500 OP Pan Bar 65 10650 PS Pan Bar 66 10800 CYCLORAMA