SECREST AUDITORIUM TECHNICAL PACKAGE

Similar documents
Sandusky State Theatre Technical Specifications

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Concert Hall Technical Specifications

Concert Hall Technical Specifications

Dr. Fred Speckeen Theatre. Information and Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Technical Information

The Breen Center for the Performing Arts Saint Ignatius High School

Performing Arts Theatre

Technical Information

Technical Services and Specification

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

SAINT ANSELM COLLEGE DANA CENTER

Technical Specifications

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

TECHNICAL PACKAGE.

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Facility Information

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Patriots Theater at the War Memorial Technical Data

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Paramount Theatre Production Recap

Technical Specifications

Lighting Information

Technical Specifications

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Technical Rider Vocal Point Season Performing Arts Management

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Technical Specifications and Inventory Spring 2018

Little River Band Production Rider 2018

JOHN W.H. BASSETT THEATRE

Main Stage Technical Specs - Hall #2

Marjorie S. Deane Little Theater

Technical Specifications. Taylor Little Theater

Technical Specifications

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Arcadia Performing Arts Center Technical Specifications and Information

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

Stephen Roy s. Black & White. On-Site Requirements Stage Setup. Ideal Performance Space Set-up Other Practical Considerations Load In Show Control

Technical Informa on.zack Theater

FOX THEATRE ST. LOUIS

Technical Specifications

Meeting Room Packages

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

DEREHAM MEMORIAL HALL

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

ADRIAN PHILLIPS BALLROOM INFORMATION AND SPECS

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

SHUBERT THEATER 247 College Street, New Haven, CT

Dinkelspiel Auditorium - Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

FIVE FLAGS THEATER SERVICES STATEMENT

General 64E4 Cultural Center is a flexible black box theater that holds 72 people including cast and crew

HALFWAY TO DAWN TOUR

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

USE OF JOHN M. GREENE HALL

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

Downtown Arts Center Tech Packet. General Information

Dr JOHN GALLAGHER CONCERT CHAMBER

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Technical Specifications

Technical requirements & conditions for hirers

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

THEATRE PROJECTS. Parts of a Theatre Building

VENUE TECHNICAL REQUIREMENTS

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

P.O Box 1171 Box Office & Theatre: (903) Main St Texarkana, TX TRAHC Office: (903) Texarkana, TX Fax: (903)

TOURING RIDER Where Magic & Motion Meet!

Matt Dann Cultural Centre

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Rentals Friedman Auditorium

Dale F. Halton Theater Technical Specifications

Rental Information. Smothers Theatre Raitt Recital Hall Lindhurst Theatre

NORTH CHARLESTON PERFORMING ARTS

NORTH CHARLESTON PERFORMING ARTS

Rickman High School Theatre RENTAL INFORMATION

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Technical Specifications

Smothers Theatre Rental Technical Specifications

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

TECHNICAL INFORMATION

Quick-Advance Fact Sheet

TECH SHEET AND INFORMATION (Updated )

Dunfield Theatre Cambridge

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Transcription:

SECREST AUDITORIUM TECHNICAL PACKAGE 334 Shinnick Street Zanesville OH, 43701 740-454-6851 www.secrestonline.com 1

CONTACTS: Technical Director Mark W Douglas Mark W Douglas LLC 835 Brighton Blvd Zanesville OH 43701 740-607-6134 (mobile) mark@markwdouglasllc.com www.markwdouglasllc.com Secrest Manager Rick Sabine 334 Shinnick Street Zanesville, OH 43701 740-454-6851 (office) rick.sabine@coz.org www.secrestonline.com GENERAL: TECHNICAL SPECS Built: 1940 Last renovated: 2013 - ongoing Seating: Orchestra (gently graded) - 1,272 Seating: 1st Balcony (gently graded) - 220 Seating: 2nd Balcony (gently graded) - 244 Proscenium width - 73 Proscenium height from stage floor - 25 103' stage center at foot to back wall of lower level 127' stage center at foot to back balcony 92' wall to wall in house Stage lip to curtain line - 3 6 Pit is located 4 5 below stage (no cover available) Curtain line to first balcony - 87 3 Curtain line to back wall of auditorium - 106 7 Stage floor is wood over concrete - gray color 1st row of seats from edge of pit - 4 2 Edge of pit from stage lip - 9 Pit width 42 10 2

MEASUREMENT: 42 stage center at foot to side torms 92' stage center at foot to balcony torms 100' stage center at foot to front of house 116' stage center at foot to Spot Booth 85' stage center at foot to FOH Booth (LD position) LIFT AND ROLLING DOOR: See attached PDF for load-in and parking Rolling Door Actual opening - Wide 9'11" x tall 9'8" Lift actual usable space - Wide 15' x length 7 6" X Height of Gate 7 4 Time of lift operation from up to down, etc. (From time door is closed) - 1 minute down - 1 minute 5 sec up 4000 LB weight limit LINE SCHEDULE: Attached via PDF- SA Line Schedule FRONT OF HOUSE POSITION (alternative location): During some shows it is necessary to place the FOH position in the audience. In those cases several rows are blocked to accommodate the FOH platform. Typical the following seats are blocked for that purpose: Row DD Seats 1-8 Row EE Seats 1-8 Row FF Seats 1-8 Row GG Seats 1-8 3

FLY SYSTEM FOR BATTENS, ELECTRICS, AND BORDERS: NO FLY LOFT Counter weigh located on Stage Right Grid Height is 32 feet Battens, Electrics, and Borders fly to 26 feet from stage Battens approximately 67 feet long - two (2) available for drops etc Arbor capacity 900 lb Weight loading capacity 700 lb FLY WEIGHTS: Red (small weight) - 15 LB Green (medium weight) - 30 LB Yellow (large weight) - 40 LB POWER DISTRIBUTION: In addition to normal house power, house maintains the following disconnects (breakout boxes): Stage L - 400 AMP Three Phase Stage R - 200 AMP Three Phase 4

HOUSE LIGHTING PACKAGE (we are updating many drawings): Attached via PDF- SA Circuits SA master hang 01 SA master hang 02 SA master hang 03 SA master hang channel list Specs: House lights are separately controlled and dimmable from Front of House position and stage right. They are not DMX controlled by the house console. 96 Dimmers (see circuits) House Console is a ETC Element 40 w/500 Channels (located at Front Of House) (2017 10 install) All house fixtures and electrics are equipped with twist-lock connectors House figures are aged and would be rated in general as good to fair. 24 male twist-lock to female three pin (slip pins) adapters are available in house 2 - StrongTrouper Model 575 Follow Spotlights FLY REFERENCES: Line LX1 Pipe weight - 195 LB Cable weight - 32 LB Electric weight - 405 LB Line LX2 Pipe weight - 195 LB Cable weight - 34 LB Electric weight - 405 LB Line LX3 Pipe weight - 195 LB Cable weight - 28 LB Electric weight - 405 LB 5

FIXTURE AND CABLE WEIGHT: Par 64-7 LB 6 Fresnel - 10 LB 8 Fresnel - 20 LB Stand Ellipsoidal - 15 LB 5 Cable - 3 LB 10 Cable - 5 LB 25 Cable - 7 LB 50 Cable - 10 LB 150 Cable - 30 LB Two-Fer - 4 LB 6

HOUSE AUDIO: House system is a mono center cluster system consisting of: Console: Beringer X32 (2017 03 Install) Mix position is in a booth at front of house. (85 stage center at foot to FOH Booth) Dennon CD player located in FOH rack Speakers: JBL Venue series M2210-6 wave guide & horn -long throw center 2 MS115 10 and horn - down throw sides 2 SR4715 X dual 15 s - 1 each side floor level 2 Control 23 front fill - mounted on front of stage 4 Control 28 balcony fill - upper balcony Processor: DSC260 system controller EQ Shure DFR11EQ-5 (accessible via laptop in FOH rack) Monitors: 6 - MR905 2 - way wedge 2 Monitor Aux Sends Amps: Crown Macro tech Wireless: 6 Shure ULX54 handheld with SM58 capsules located in FOH rack 2 Shure ULX54 with beltpack, Lav or instrument cable located in FOH rack Misc: Various hardwire microphones SM57 & SM58 Boom and straight mic stands. XLR and 1/4 speaker cable (various lengths) 7

COMMUNICATION: Clear Com System (two channel - production and spotlight operators - can be party) Control is at front of house. Positions: Control at Lighting Console - one ear muff( 1) Audio - one ear muff (1) Spotlight - one ear muff( 2) Stage Left - one ear muff (1) Stage Right - one ear muff (1) Extra - one ear muff( 2) 8

SOFT GOODS: SA Line Schedule (attached as PDF) 1 Brick Colored Grand (full travel) - manual pull 1 Set of Colonial Brick Colored Legs (limited travel) 1 brick Grand boarder (dead hung) 1 Black Act downstage curtain (full travel) at 9 from grand curtain line - Manual pull 1 Black upstage curtain (full travel) at 28 from grand curtain line - Manual pull 3 Sets of Black Legs (limited travel) 3 Black Boarders (hide lights) - limited fly 1 very light blue CYC (dead hung) roughly 67 X 27 FLY SYSTEM FOR BATTENS, ELECTRICS, AND BORDERS: NO FLY LOFT Counter weigh located on Stage Right Grid Height is 32 feet Battens, Electrics, and Borders fly to 26 feet from stage Battens approximately 67 feet long - two (2) available for drops etc Arbor capacity 900 lb Weight loading capacity 700 lb SPECIAL EFFECTS (FX): HAZE is permitted. (unit is available for rent from local vendor) FOG is permitted. (unit is available for rent from local vendor) CRYRO is permitted. Must be inspected by the City of Zanesville Fire Department (Fire Marshall) prior to use. PYRO typically is not permitted. If permission is granted, equipment manufacture data cut sheet must be submitted in advance. Fire Marshall will see a DEMO on the day of the show. Fire Marshall makes the final decision the day of DEMO. PLATFORMS: Secrest has numerous 4 X 8 X 6 and 4 X 8 X 12 platforms. NO STAPLES / NAILS are permitted to be use on platforms 9

MISC: 24 Genie Lift 16 A-Frame ladder with no wheels 1 Hamilton Conductor Music Stand 25 Hamilton Music Stands Baldwin 9 Concert Grand C-10 Piano (tuning at a cost of $100 per tuning will be billed to the client) TAPE: Only gaffers tape and spike tape may be used on stage. If the customer does not have gaffers tape or spike tape - multiple colors the house has tape at $25 and $15 per roll respectively. They will be added to the house bill. DANCE MARLEY: Marley is available for rent. A local dance company owns the Marley Dance Floor and makes it available for a rental as a day/weekly rate. If interested the cost will include: Marley Dance Floor, tape, installation. 10

PERSONNEL / STAFFING is a NON-UNION house. For Touring Acts: The Technical Director or their designee will be present for each tech, rehearsal, and shows. The technical Director makes the final determinations concerning house technical details and safety. Technical personnel and stage hands for touring acts will be staffed based upon tour and house requirements and per contract / rider. For Non-Touring acts: has a limited number of technicians and stage hands. If the number of stage hands exceeds those normally available, job-in stage hands or volunteers, may or may not be used at the discretion of the Technical Director. An orientation shall be attended by job-in stage hands and volunteers prior to load in. All technical calls are for a five (5) hour minimum. The Technical Director or their designee will be present for each tech, rehearsal, and show. The house cost for the Technical Director is $25 per hour for actual onsite hours as well as show advance hours. The technical Director makes the final determinations concerning house technical details and safety. A Audio Technician will be present for each tech, rehearsal, and show. The house cost for the Audio Technician is $20 per hour for actual onsite hours as well as show advance hours. (The Technical Director may fill this role the role of Audio Technician or Lighting Technician if appropriate - but not both roles). A vetted, insured (liability insurance and workers compensation), and approved vendor may be selected from the approved vendor list. Compensation for the approved vendor is determined by the client and the vendor based upon personnel and equipment. A Lighting Technician will be present for each tech, rehearsal, and show. The house cost for the Lighting Technician is $20 per hour for actual onsite hours as well as show advance hours. (The Technical Director may fill this role the role of Audio Technician or Lighting Technician if appropriate - but not both roles). A vetted, insured (liability insurance and workers compensation), and approved vendor may be selected from the approved vendor list. Compensation for the approved vendor is determined by the client and the vendor based upon personnel and equipment. 11

A Stage Technician will be present for each tech, rehearsal, and show. The house cost for the Stage technician is $15 per hour for actual onsite hours as well as show advance hours. If spotlights are used, Spotlight Operators will be made available based upon schedule. The house cost for the Spot Operators is $15 per hour per person for actual onsite hours. A Janitorial / Maintenance staff will be present for each tech, rehearsal, and show. The number needed will depend on the size of the crowd. The house cost for the Janitor is $15 per hour for actual onsite house as well as show advance hours. BREAKS AND MEALS: It is expected that there will be a fifteen minute break every two (hours) with a thirty minute to one hour meal break at the four hour mark. These are negotiable in terms of timing. However, when the breaks happen work and tech shall stop to allow for the break / meal. APPROVED AND VETTED VENDORS: The house has a small list of vendors (audio, lighting, and labor) who have been vetted and approved. They are permitted to work the house. The Manager and Technical Director can discuss your specific needs. 12

GENERAL HOUSE RULES: A. No Food or Drink allowed in the auditorium other than bottles water. Some shows may have beer sales. Those bottles may be in designated areas only. B. All children are to be supervised at all times. C. No running is allowed in the theatre. D. Balcony and other parts of the facility are not open during rehearsals unless specific arrangements have been made. E. During Rehearsal times only designated doors may be used for entering or exiting. F. No staples are to be used on staging and walls of the theatre, G. No packing tape is permitted. Only gaffers tape is permitted and is available for purchase if the group does not bring their own. H. No signage can be taped or affixed to the wall, doors, or glass of the theatre. I. Only technical personnel and performers are permitted on stage, back stage, and other designated areas - for technical personnel and performers. This means the public is not permitted in these specific areas. J. Only Technical personnel or trained volunteers may run the fly rigging. K. Each event shall have off-duty uniformed police officers to serve as event security during public hours. The number of officers will depend on the size and scope of the event. EMERGENCY EXITS: In the unlikely event of an emergency, there are orange aisle way lights directing you to the rear of the auditorium. There is an emergency exit located on house right near the stage. From stage, there is an emergency exit to the rear of Stage Right. From stage, there is an emergency exit on Stage Left. At the foot of the stage is a set of steps on Stage Left and on Stage Right. PDF ATTACHMENTS: SA master hang 01 SA master hang 02 SA master hang 03 SA Circuits SA Line Schedule Lift and Rolling Door Center Stage to FOH Lighting Secrest Seating Chart with Lobby Secrest Basement Parking Map Zanesville Secrest 13