Analysis of AP/axon classes and PSP on the basis of AP amplitude

Similar documents
A low noise multi electrode array system for in vitro electrophysiology. Mobius Tutorial AMPLIFIER TYPE SU-MED640

NENS 230 Assignment #2 Data Import, Manipulation, and Basic Plotting

Getting started with Spike Recorder on PC/Mac/Linux

Lab experience 1: Introduction to LabView

iworx Sample Lab Experiment AN-13: Crayfish Motor Nerve

System Requirements SA0314 Spectrum analyzer:

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

The most sensitive microelectrode array system for in vitro extracellular electrophysiology. Mobius Tutorial AMPLIFIER TYPE MED-A64MD1/MED-A64HE1

Dektak Step by Step Instructions:

MAutoPitch. Presets button. Left arrow button. Right arrow button. Randomize button. Save button. Panic button. Settings button

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

E X P E R I M E N T 1

MestReNova Manual for Chem 201/202. October, 2015.

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Technical Specifications

The Measurement Tools and What They Do

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Lesson 1 EMG 1 Electromyography: Motor Unit Recruitment

The BAT WAVE ANALYZER project

Guide to Analysing Full Spectrum/Frequency Division Bat Calls with Audacity (v.2.0.5) by Thomas Foxley

Tutorial FITMASTER Tutorial

BASIC TUTORIAL. Jocelyn Mariah Kremer, Mike Mullins Documentation BIOPAC Systems, Inc. William McMullen Vice President BIOPAC Systems, Inc.

SpikePac User s Guide

Experiment PP-1: Electroencephalogram (EEG) Activity

MultiSpec Tutorial: Visualizing Growing Degree Day (GDD) Images. In this tutorial, the MultiSpec image processing software will be used to:

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Analyzing and Saving a Signal

PulseCounter Neutron & Gamma Spectrometry Software Manual

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B.

Renishaw Ballbar Test - Plot Interpretation - Mills

Overview. Signal Averaged ECG

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

Background. About automation subtracks

BioGraph Infiniti Physiology Suite

Scout 2.0 Software. Introductory Training

PROCESSING YOUR EEG DATA

Processing data with Mestrelab Mnova

Experiment P32: Sound Waves (Sound Sensor)

Audacity Tips and Tricks for Podcasters

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Activity P27: Speed of Sound in Air (Sound Sensor)

Dektak II SOP Revision 1 05/30/12 Page 1 of 5. NRF Dektak II SOP

Precision DeEsser Users Guide

Practicum 3, Fall 2010

Lesson 14 BIOFEEDBACK Relaxation and Arousal

Heart Rate Variability Preparing Data for Analysis Using AcqKnowledge

Activity P32: Variation of Light Intensity (Light Sensor)

WAVES Cobalt Saphira. User Guide

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

MODFLOW - Grid Approach

Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada

Introduction to the oscilloscope and digital data acquisition

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

v. 8.0 GMS 8.0 Tutorial MODFLOW Grid Approach Build a MODFLOW model on a 3D grid Prerequisite Tutorials None Time minutes

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

WindData Explorer User Manual

Detect Color and Shape for various inspection

DektakXT Profilometer. Standard Operating Procedure

Table of Contents Introduction

Laboratory 5: DSP - Digital Signal Processing

Event recording (or logging) with a Fluke 287/289 Digital Multimeter

Getting Started with the LabVIEW Sound and Vibration Toolkit

3jFPS-control Contents. A Plugin (lua-script) for X-Plane 10 by Jörn-Jören Jörensön

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

PS User Guide Series Seismic-Data Display

013-RD

Introduction to GRIP. The GRIP user interface consists of 4 parts:

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

SigPlay User s Guide

FS3. Quick Start Guide. Overview. FS3 Control

TA Instruments Cement Analysis Software Getting Started Guide

EDL8 Race Dash Manual Engine Management Systems

There are many ham radio related activities

Agilent DSO5014A Oscilloscope Tutorial

HV/PHA Adjustment (PB) Part

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

MestReNova A quick Guide. Adjust signal intensity Use scroll wheel. Zoomen Z

Chapter 5. Describing Distributions Numerically. Finding the Center: The Median. Spread: Home on the Range. Finding the Center: The Median (cont.

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Measuring Delays. A Step by Step instruction. (c) 2017 by Thomas Neumann

VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below.

PYROPTIX TM IMAGE PROCESSING SOFTWARE

Lesson 10 Manual Revision BIOPAC Systems, Inc.

The EEGer 4.3 Tutorial

Quick Reference Manual

The Syscal family of resistivity meters. Designed for the surveys you do.

Pre-Processing of ERP Data. Peter J. Molfese, Ph.D. Yale University

9070 Smart Vibration Meter Instruction Manual

DATA! NOW WHAT? Preparing your ERP data for analysis

iworx Sample Lab Experiment AM-9: Crayfish Gut Pharmacology

Basic Terrain Set Up in World Machine:

Standard Operating Procedure of nanoir2-s

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

Spectrum Analyser Basics

invr User s Guide Rev 1.4 (Aug. 2004)

Transcription:

Analysis of AP/axon classes and PSP on the basis of AP amplitude In this analysis manual, we aim to measure and analyze AP amplitudes recorded with a suction electrode and synaptic potentials recorded with a sharp electrode in a muscle fiber. The suction electrodes and sharp electrode recordings were be obtained simultaneously so that we can match synaptic responses with the action potentials that evoke them. Before you start: HOW TO RUN COMMAND? Most of the analysis commands have been written for you in a NoteBook called Analysis Script. To run these commands, you need to highlight the commands, hit Return while holding Ctrl key. There are lines started with "//". These are comment lines you should read so you know what to look for in the graphs that appeared after you run your command. STEP 1: check stability. Highlight all 4 lines and run them, there should be a graph which looks like this (Fig.1): Fig.1 Here, the X-axis is trace numbers. You should have 2. (Students in my lab sometimes run 7-1 traces.) The lines in the graph are color coded: black for muscle resting V m, blue for the noise level of muscle fiber and red for noise level of the third nerve. There are three Y axis: left for muscle Vm, right for noise level of muscle fiber, right middle for noise level for axon. Noise level means the standard deviation of each of the 2 traces, a good indicator if the nerve or muscle increased/decreased its activity in response to the drug or neuromodulator. 1

In general, if muscle V m changes for less than 1 mv, then you are ok. STEP 2: set noise level. Run the top 3 lines first. Igor will spin away for a few minutes. Let it be. No graph will be displayed. Run the next three lines; there should be a graph that pops up (Fig.2). There are three steps in this analysis. First, we need to set a threshold, typically 3 times the background noise. Signals with amplitudes higher than the threshold are considered real. You need to drag the two cursors to a section of the trace where you know there is no AP, see Fig.2. Fig.2 Execute the next line, which starts with "Wavestats " You should then see a printout below your command: v_sdev= xxxxx This is the standard deviation of the baseline noise level. STEP 3: Spike sorting Run the single line starting with "AP_peak_search_..." Go to have a cup of coffee, it will take ~1 to 3 minutes. The software is sorting through all 2 traces and pick out every one of the APs recorded by your suction electrode. In some preparations, there will be more than 1, events. Note: This step is computationally intensive, your computer will run hot. Make sure that your laptop is plugged in and placed in a well-ventilated place, i.e. on desk but no on bed or sofa where air vent may be blocked. A little more details about what this sorting program is doing. This program will use the V_sdev*3 as threshold, find spikes above the threshold and measure the amplitudes of action potentials, by taking the difference between the maximum and the minimum of each AP (Fig.3). Fig.3 1 5 max µv -5-1 min.3.32.34 s.36.38 2

At the end of "AP_peak_search_select("ctrl",sel_first,sel_last)", you should see a plot of AP amplitudes found in the two hundred traces you have collected (Fig.4). The left Y-axis is the AP amplitude and X-axis is the AP number. (There are more than 2 in this experiment!) The right axis corresponds to the blue line, which indicates the trace numbers, from 1 to 2. For example, the 1, th event (vertical green arrow) was detected in trace 86 (horizontal green arrow). The graph shows that the amplitudes cluster around 5 levels (data bands), suggesting potentially 5 axons with different amplitudes. (It turns out that the lowest one, the blue arrow, is not real.) Fig.4 1 AP amp (µv) 8 6 4 2 AP3 AP4 AP1 AP2 5 1 15 trace number 5 1 15 2 number of events (x1 3 ) Sidebar: It is important to check the plot of AP amplitude in figure 4 carefully. Sometimes the 3 rd nerve gradually or suddenly slips out of the suction electrode tip and the amplitude plot may look like the graph shown in the right instead. In this case, although the data bands are clear, there is obviously a continuous decline in all the bands. The nerve appears to have slipped out of your suction electrode gradually. We cannot analyze data that are drifting continuously. We can select a subset of data ranges within which AP amplitudes are relatively stable, from event 8 to 12 for example. The AP event range of 8-12 corresponds to traces 14-2. Later when we analyze AP1 to AP4 individually, we should use only traces 14-2. AP amp (µv) 1 8 6 4 2 5 1 number of events (x1 3 ) 2 1 trace number 3

STEP 4: Analysis of individual AP Run the first 3 lines. They are meant to define variables and strings to be used later. No need to read deep meaning into them. You next need to enter three numbers before we run the next macro. The first number is peak_num. As a convention, we will name the smallest AP as AP1. If we start with AP1, we should make peak_num=1 by overwrite the "?" under the comment "//Need to enter peak_num, ap_peak_low, ap_peak_high" The second and third numbers are determined after you position the round and square cursors: For the analysis of AP1, we need to tell the software the range of AP amplitude acceptable as AP1. We accomplish this by placing the round cursor in the lower boundary of the data band corresponding to AP1 and the square cursor in the upper boundary (Fig.5A and B). (You can zoom in the region to position the cursors precisely by drawing a square at the area of interest and right clicking, then choose any of the expansion options you like. To zoom out, just click Ctrl-a.) This may be obvious but just to remind you, the numbers you should read are the Y-values. Smaller Y value for ap_peak_low and larger Y value for ap_peak_high (Fig.5B circle). Just to be methodical, you should enter the numbers exactly as shown in the cursor strip. Wait there are two more numbers you may want to check. The line starting with "cut_and_show_..." is the macro that will pull out all the APs with amplitude within the range defined by ap_peak low and high. The macro will also "cut out" traces in the muscle recordings, to isolate EPSPs evoked by AP1. There are two numbers (1,2) at the end of the macro command. They define the traces you will use to pick out AP1. The default is 1,2 because that is the number of traces you have in your file. However, sometimes not all our traces are equally good. For example, inspection of Figure 1 may suggest that only traces 1 to 2 have stable muscle V m. If so, the last two numbers should be 1,2. Our discussion in Fig.4 led us to the decision that trace 14 to 2 cover a window within which AP amplitudes were stable. If your data look perfect, you can set the trace range as 1,2. In this case, you will have the benefit of very large sample size. Hight the four lines starting with peak_num and execute them. For AP2, you should copy and paste the four lines you used for AP1 and change peak_num to 2 and reposition the cursors and update ap peak low and high for AP2. It is strongly recommended that you don t overwrite what you have done for AP1 so you can easily check the parameters you have used for AP1 later. Don t forget to change the peak_num for each AP, otherwise the APs and PSP selected for the last AP peak_num will be overwritten. In most preparations, we analyze APs from 4 axons that fire at high frequency and give us a good sample size. 4

Fig.5 For each Fig.6 microv 1 5-5 -1-15 -2 of the APs you pick, you should get a graph likee this: peak= 1, event=324.4.3.2.1. -.1 -.2 mv 2 25 3 35 4 ms The grey trace is the averaged AP from 324 trials, the black averaged EPSP. (The AP is aligned at the 2ms location.) Red and blue traces are randomlyy selected AP and EPSP traces from the 324 events. Some of the red traces have ugly transientss shooting up and down. Those are APs from other axons that happen to fire shortly after AP1 fires. Don t be alarmed if your black and blue traces look flat. In this case, it means that the axon you selected didd not make synaptic contact with thee muscle fiber you have recorded from. The data will still be useful as a reference for our project. This graph will be live while you are running the "cut_and_show_psp " command. It puts somewhat of a load on the computer as the graph needs to be updated from time to time but I left this feature in so you can watch the process of data selection. Note: this macro may run for a while, just watch it and don't click on any windows. (Sorry about being so blunt, if you click otherr windows, the program will start to 5

append those blue and red traces in windows for which they are not intended). Watching traces appending to the graph becomes tedious after a while, you are allowed to walk away! Further notes: You are most likely to have to run the same analysis for before and after a drug or neuromodulator. In other words, you would want to compare AP1 before and after an experimental manipulation. To avoid confusion, you should give a different peak_num after drug/modulator. For example, AP1 after drug should be given peak_num=11 and become AP11. Peak_num must be a numerical value. STEP 5: Further analysis of individual APs. Now that we have isolated individual APs, we are ready to make measurements of the following parameters: AP amplitude, AP maximum, AP minimum, AP duration, EPSP amplitude, EPSP delay. Of these parameters: EPSP amp and AP amp will appear on the 1 st graph, EPSP amp and EPSP delay 2 nd graph, AP max and AP min 3 rd graph, AP amp and AP dur 4 th graph, EPSP amp histogram 5 th. First execute the first two lines, to define variables. We next need to tell the macro which AP are we analyzing and how many APs have been detected as AP1. For this information, just go back to the graph and the legend box should have the info. The example in Fig.6 says this is AP1 and there are 324 traces. Enter the corresponding number from your data in num_traces= and peak_num=. (peak_num=1 and num_traces=324 in this case.) We then need to tell the macro where to make measurements for EPSP amplitude. We need to define where the baseline is and where the peak of EPSP is. For the measurement of EPSPs associated with AP1, we should go back to the graph window for AP1 (Fig.6). We define the EPSP baseline by placing the cursors in a time window after the AP and before EPSP takes off (Fig.7A red circle). We then need to read the X-values (Fig.7A green circle) and enter into bfrom and bto. The macro will take all the data points between bfrom and bto and average them. The average value will be the baseline. Next, you need to move the cursors to the top of EPSP (Fig.7B red circle). The cursor values on X-axis (green circle) will be entered as sfrom and sto. Now we are ready to execute the macro. Highlight all 7 lines, from "num_trace= " to "epp_histogram_etc( )". (Note that you must execute all 7 lines, including the ones with numbers you just entered, so the macro knows which AP/EPSP to measure etc.) 6

Fig.7 When the epp_histogram_etc finishes analysis, you will have a busy desktop (Fig.8). All the traces on the graph are labeled in the legend. You will need to repeat this analysis for your experimental file, after drug/modulator, and compare them. Fig.8 ***Now is the time to stare at the data and think!! 7

A few tips for furtherr analysis and comparison. I. Save your experiment from time to time as you go through each steps of your analysis. The file get quite big, don t be alarmed. II. To help organizingg your graphs, it would be useful to put figures from each axon on a separate desktop. To do this you should download a plugg in for Igor from: http://www.igorexchange.com/project/acl_windowdesktops Extract the files and put all of them in Igor Procedures folder within Igor Pro Folder. Relaunch Igor, Misc Desktop Control Panel. The control strip willl show up (Fig.8 red circle). III. You are likely to want to have results from control and experimental files of the same axon, say AP amp of AP1, to be side by side so you can compare them properly. One simple way to do this is the following: 1. click on the graph you would like to compare so it is onn top. 2. graph packages save graph. 3. all the info in your graph will be saved in a text file. 4. open a new Igor experiment and drag the text file intoo Igor, you will see the graph. (Mac users will have to right click the text file and use "Open with" option.) Do the same for control and drug experiments then you will have both graphs in the same Igor file and the comparison will be easier. IV. Sometimes you would want to display two traces on the same graph to really compare them. 1. Right click on the 1 st trace you would like to compare, select "Copy Display Command" from the context menu (Fig.9 arrow 1). 2. Paste the command in the command window at the bottom of the monitor (Fig.9 arrow2) then hit return. 3. A new window will appear with the trace you select. 4. go to the second graph where you want to select a trace to be displayed in the same window as the first one. Go through the same steps, right click copy display command paste in the command window. Fig.9 5. However, you now need to delete the "display" and replace it with "append", don t hit return yet. 6. Click on the graph window you would like the trace too append to and hit return. 8