Standard for Reporting Refractive Outcomes of Intraocular Lens Based Refractive Surgery

Similar documents
* Villegas EL, Alcón E, Artal P. Minimum amount of astigmatism that should be corrected. J Cataract Refract Surg 2014; 40: n My SIA: Ø Centroid

White Paper. Astigmatism Management With Toric IOLs The Importance of Rotational Stability After IOL Implantation. Xiaolin Gu, M.D., PhD.

Total corneal astigmatism in older adults taking into account posterior corneal astigmatism by ray tracing

Richard N. McNeely 1,2, Salissou Moutari 3, Eric Pazo 1,2 and Jonathan E. Moore 1,2*

Abstract. imedpub Journals Vol.3 No.2:27. Introduction

Irregular Corneal Astigmatism & Cataract

Handout Course Title : Astigmatisme Management with toric IOL

2Optimizing the Refractive

Premium treatment starts with premium diagnosis

Toric intraocular lenses

Evaluation of Opposite Clear Corneal Incision in Controlling Astigmatism in Cataract Patients Undergoing Phacoemulsification Surgery

DOWNLOAD ASTIGMATIC TECHNIQUE IN ONE STEP RAINBOW HOLOGRAPHY

4/9/2016. Sources of. Single-angle vs. double-angle plots for astigmatism data. Commercial Toric IOL calculators. Unexpected residual astigmatism!

The Short Term Effects of a Single Limbal Relaxing Incision Combined with Clear Corneal Incision

Arthur Cummings FRCSEd

Management of astigmatism at the time of cataract or refractive lens surgery has evolved to include arcuate keratotomy and toric

ORIGINAL ARTICLE. Primary Topography-Guided LASIK: Treating Manifest Refractive Astigmatism Versus Topography-Measured Anterior Corneal Astigmatism

Novel Microscope Mounted Digital Keratoscope for Intra-Operative Toric IOL Alignment

AXsys Studay Data and Press Release Reference

Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators

Prospective study of toric IOL outcomes based on the Lenstar LS 900 W dual zone automated keratometer

Non-penetrating Femtosecond Laser. intrastromal astigmatic keratotomy (ISAK) Patients With Mixed Astigmatism After Previous Refractive Surgery

Index. D DALK, 69, 155 Differential sector index (DSI), 92 Discriminant function analysis, DMEK, 23 Donor factors, 156 DSAEK, 23

Results of Intraoperative Manual Cyclotorsion Compensation for Myopic Astigmatism in Patients Undergoing Small Incision Lenticule Extraction (SMILE)

Postoperative Astigmatic Outcomes Based on the Haptic Axis of Intraocular Lenses Inserted in Cataract Surgery

Development of a program for toric intraocular lens calculation. considering posterior corneal astigmatism, incisioninduced

Douglas Katsev MD Sansum Clinic Chairman Ophthalmology Santa Barbara CA

No financial interest

New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder

AXsys Study Data and Press Release Reference

2nd ESASO Anterior Segment Academy April 2016, Milano/Italy

Arcuate Keratotomy for High Postoperative Keratoplasty Astigmatism Performed With the IntraLase Femtosecond Laser

POST-OPERATIVE ASTIGMATISM AFTER SICS AND PHACOEMULSIFICATION.

Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent

Phacoemulsification: The first 50 Cases

CHANGE ON THE HORIZONTAL AND VERTICAL MERIDIANS OF THE CORNEA AFTER CATARACT SURGERY*

LASIK for post penetrating keratoplasty astigmatism and myopia

Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism

Full-Thickness Astigmatic Keratotomy Combined With Small-Incision Lenticule Extraction to Treat High-Level and Mixed Astigmatism

Clinical outcomes of Transepithelial photorefractive keratectomy to treat low to moderate myopic astigmatism

Femtosecond Cataract Surgery: Correction of Astigmatism and Complex Cases Financial Disclosures Femtosecond Laser Utility in Cataract Surgery

Over the last decade, a vast improvement on intraocular

Effect of Pupil Size on Uncorrected Visual Acuity in Pseudophakic Eyes With Astigmatism

Assessment & management of irregular astigmatism

The efficacy of Toric IOL in comparison to LRI in correcting pre-existing astigmatism in phacoemulsification

Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery

Clinical results of arcuate incisions to correct astigmatism

Clinical Study Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass Instrument

Disclosure. Getting Up to Date with LASIK. Modern advancements LASIK. What we re curing. Changing the corneal surface

Circular Keratotomy to Reduce Astigmatism and Improve Vision in Stage I and II Keratoconus

STUDY OF ASTIGMATISM IN SMALL INCISSION CATARACT SURGERY BETWEEN TEMPORAL AND SUPERIOR INCISSIONS K. J. N. Sivacharan 1, G.

Dr Noel Alpins AM Digest of Personal and Professional biography

Refractive, anterior corneal and internal astigmatism in the pseudophakic eye

Femtosecond laser-assisted astigmatic keratotomy: a review

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Astigmatism in Children: Changes in Axis and Amount from Birth to Six Years

AstigmatismamongotherRefractiveErrorsinChildrenofSouthernSriLanka. Astigmatism among other Refractive Errors in Children of Southern Sri Lanka

OPTOMETRY. An analysis of the astigmatic changes induced by accelerated o rt ho ke ratolog y I ORIGINALPAPER 1

Lin Liu, Jun Zou *, Hui Huang, Jian-guo Yang and Shao-rong Chen

620 Rejwrts Investigative Ophthalmology

Handheld Shack Hartmann Wavefront Sensor. Jim Schwiegerling, Ph.D. Department of Ophthalmology and Optical Sciences The University of Arizona

A novel method for human Astigmatism formulation and measurement

THE CHALLENGES CORNEAL IRREGULARITIES POST-LASIK ECTASIA IS THIS A GOOD LASIK CANDIDATE? 3/5/2015. FITTING THE IRREGULAR CORNEA Challenges & Solutions

Irregular Astigmatism Diagnosis And Treatment

Research conducted over the past 15 years has yielded a

Proposed classification for topographic patterns seen after penetrating keratoplasty

1. Introduction. Correspondence should be addressed to Edmund Arthur; arthur

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Orthokeratology (Ortho-K), or corneal refractive therapy, is. Toric Double Tear Reservoir Contact Lens in Orthokeratology for Astigmatism ARTICLE

Analysis of WFS Measurements from first half of 2004

Cycloplegic Refractions of Infants and Young Children: The Axis of Astigmatism

Astigmatic axis and amblyopia in childhood

A R Sebai Sarhan, Harminder S Dua, Michelle Beach

ORIGINAL ARTICLE. Corneal and Refractive Error Astigmatism in Singaporean Schoolchildren: a Vector-Based Javal s Rule

ORIGINAL ARTICLE. Amblyopia in Astigmatic Infants and Toddlers

Diagnosis and Management of Astigmatism

Correcting Your Vision: Advice and Opinions from an Eye Surgeon Health Radio April 17, 2007 Mark Walker, M.D. Introduction

Astigmatism: analysis and synthesis of the astigmatic ametropia

NIH Public Access Author Manuscript Optom Vis Sci. Author manuscript; available in PMC 2011 May 1.

Coding Productivity & Audit. Laura Dornsife Director, Coding & Revenue Cycle Support

in the Howard County Public School System and Rocketship Education

Eyes with regular astigmatism have two orthogonal focal. Accommodation in Astigmatic Children During Visual Task Performance

balt5/zov-opx/zov-opx/zov01005/zov a washingd S 12 10/4/05 14:54 Art: OPX Input-nlm ORIGINAL ARTICLE

CA-800 Tear Module. Rick Gaudenti. Product Manager, Refraction Mar 2017

Astigmatism is a common refractive error 1 and an important. The Changing Profile of Astigmatism in Childhood: The NICER Study

STAT 113: Statistics and Society Ellen Gundlach, Purdue University. (Chapters refer to Moore and Notz, Statistics: Concepts and Controversies, 8e)

Modeling memory for melodies

SIMULATION OF PRODUCTION LINES THE IMPORTANCE OF BREAKDOWN STATISTICS AND THE EFFECT OF MACHINE POSITION

1. Standard Equipment Subjective Eye Tester Name of Parts Details of Auxiliary Lenses Measuring Performance...

OPTOMETRY INVITED REVIEW. A review of astigmatism and its possible genesis

What to consider when choosing a mammography display

Fast Ethernet Consortium Clause 25 PMD-EEE Conformance Test Suite v1.1 Report

Estimation of inter-rater reliability

Connection for filtered air

How to Talk with Your Doctor About Music During Surgery (or other medical or dental procedures)

Astigmatism: Aberration or ametropia?

Ahigh prevalence of astigmatism has been documented

The Music-Related Quality of Life (MuRQoL) questionnaire INSTRUCTIONS FOR USE

SPECIFICATION MEGATRON S3 The MEGATRON S3 is a modular system that can be customized according to the surgeons preferences.

The CV provides complete support for Cataract and Vitreoretinal surgery with four features that enhance usability:

Transcription:

EDITORIAL Standard for Reporting Refractive Outcomes of Intraocular Lens Based Refractive Surgery Dan Z. Reinstein, MD, MA(Cantab), FRCSC; Timothy J. Archer, MA(Oxon), DipCompSci(Cantab); Sathish Srinivasan, FRCSEd, FRCOphth, FACS; Nick Mamalis, MD; Thomas Kohnen, MD, PhD, FEBO; William J. Dupps, Jr, MD, PhD; J. Bradley Randleman, MD F ollowing the 2014 update to the Graphic Reporting of Outcomes of Refractive Surgery 1 to include vector analysis of astigmatism, 2 the set of 9 standard graphs has provided a detailed 1-page summary for outcomes of corneal laser refractive surgery (laser in situ keratomileusis [LASIK], photorefractive keratectomy, and small incision lenticule extraction [SMILE]). Until now, the data reporting quality for intraocular lens (IOL) surgery has not benefited from these efforts to enhance and standardize refractive outcomes reporting. For example, a significant number of cataract and lens refractive surgery publications do not include any refractive predictability outcomes, and visual acuity is often reported only as mean values rather than using histograms a point that was raised in the 2009 editorial. 1 In this editorial, we have considered these issues and have synthesized a solution by making some adjustments to the graphs when reporting IOL surgery outcomes. For phakic IOL outcomes, the original graphs 1,2 can typically be used without alteration, even though in reality the incision placement likely has some small effect on outcomes. Similarly, these same graphs can be used for refractive lens exchange (RLE); although there are complexities introduced by the corneal incision and removing the natural lens, the presence of a cataractous lens does influence the situation enough to render parts of the analysis inappropriate or unnecessary for a minimum standard. Because the primary indication for cataract surgery is a cataract-related loss of corrected distance visual acuity (CDVA), it remains important to report the surgically induced change in CDVA. However, this comparison is less informative about the refractive efficacy of the procedure. Thus, the basic standard for reporting cataract surgery refractive outcomes will now be a straightforward set of 4 graphs (Figure 1). In the sections below, the issues associated with each of the 9 graphs and the decision process to refine the cataract surgery graphs are discussed in the context of corneal and intraocular surgery. Efficacy: Histogram of Postoperative CDVA and UDVA In non-cataractous patients, it is important for all types of corneal or lens-based refractive surgery to re- From London Vision Clinic, London, United Kingdom (DZR, TJA); the Department of Ophthalmology, Columbia University Medical Center, New York, New York (DZR); Centre Hospitalier National d Ophtalmologie, Paris, France (DZR); Biomedical Science Research Institute, University of Ulster, Coleraine, Northern Ireland (DZR, TJA); University Hospital Ayr, Ayr, Scotland, United Kingdom (SS); Intermountain Ocular Research Center and John Moran Eye Center, University of Utah, Salt Lake City, Utah (NM); the Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany (TK); Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio (WJD); Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio (WJD); the Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio (WJD); the Department of Ophthalmology, Keck School of Medicine, University of Southern California, Los Angeles, California (JBR); and University of Southern California Roski Eye Institute, Los Angeles, California (JBR). Supported in part by an unrestricted departmental grant to the University of Southern California Roski Eye Institute Department of Ophthalmology from Research to Prevent Blindness, Inc., New York, New York (JBR) and NIH R01 EY023381 (WJD). Dr. Reinstein is a consultant for Carl Zeiss Meditec (Jena, Germany), has a proprietary interest in the Artemis technology (ArcScan Inc., Morrison, Colorado), and is an author of patents related to VHF digital ultrasound administered by the Cornell Center for Technology Enterprise and Commercialization (CCTEC), Ithaca, New York. Dr. Mamalis is on the board of Anew Optics, Inc., and is a consultant for Medennium, Inc. Dr. Kohnen is a consultant for or on the advisory board of Abbott, Alcon, Geuder, Oculus, Santen, Schwind, Staar, TearLab, Thea Pharma, Thieme Compliance, Ziemer, and Zeiss and has received research funding from Abbott, Alcon, Hoya, Oculentis, Oculus, Schwind, and Zeiss. Dr. Dupps is a member of the medical advisory board of Avedro, has performed sponsored research for Carl Zeiss Meditec and Alcon (Fort Worth, Texas), and is an author of patents related to computational modeling of the eye and OCT elastography administered by Cleveland Clinic Innovation, Cleveland, Ohio, and licensed to OptoQuest, Inc., Cleveland, Ohio. The remaining authors have no proprietary or financial interest in the materials presented herein. This editorial will also appear in the April 2017 issue of the Journal of Cataract & Refractive Surgery. Correspondence: Dan Z. Reinstein, MD, MA(Cantab), FRCSC, London Vision Clinic, 138 Harley Street, London W1G 7LA, United Kingdom. E-mail: dzr@londonvisionclinic.com doi:10.3928/1081597x-20170302-01 218 Copyright SLACK Incorporated

Figure 1. Standard graphs for reporting refractive outcomes for intraocular lens based procedures in a cataract population: (A) uncorrected distance visual acuity (UDVA); (B) UDVA vs corrected distance visual acuity (CDVA); (C) spherical equivalent refraction accuracy; and (D) postoperative refractive cylinder. D = diopters port the postoperative uncorrected distance visual acuity (UDVA) in the context of the preoperative CDVA to avoid apparent differences in refractive efficacy between studies that were in fact simply the result of a difference in the CDVA. On the other hand, the preoperative CDVA is not helpful for assessing refractive outcomes in a cataract population because the removal of the lens will typically achieve a significant improvement in visual acuity independently of the refractive correction. Therefore, this graph will be adapted to show postoperative CDVA and postoperative UDVA for cataract populations. In this way, the UDVA will be reported in the context of the best measured visual Journal of Refractive Surgery Vol. 33, No. 4, 2017 acuity. This will be Figure 1A in the Standard Graphs for Cataract Surgery. Efficacy: Histogram of Lines of Difference Between Postoperative UDVA and CDVA As for the first efficacy graph, it is not appropriate in a cataract population to compare the preoperative CDVA to the postoperative UDVA; it is more appropriate to use the postoperative CDVA. In this way, the efficacy is normalized to the best measured visual acuity for the population, making this directly comparable between studies. This will be Figure 1B in the Standard Graphs for Cataract Surgery. 219

Safety: Histogram of Lines of Difference Between Preoperative and Postoperative CDVA As for the 2 efficacy graphs, the change in CDVA for a cataract population will be dominated by the removal of the cataractous lens. This outcome parameter therefore does not provide information relevant to the performance of the procedure from a refractive surgery point of view. Therefore, this graph can be excluded when reporting outcomes for a cataract population. Although it is still important to report the preoperative and postoperative CDVA for a cataract population, this is an instance in which mean visual acuities would be sufficient. However, it is important to also report the percentage of eyes in which the postoperative CDVA was worse than the preoperative (with cataract) CDVA. Achieved Versus Attempted Spherical Equivalent Refraction Scatter Plot This graph is compromised when analyzing the outcomes of surgery on eyes with cataract because of the reduced reliability of the preoperative manifest refraction. Therefore, this graph may be excluded from the Standard Graphs for Cataract Surgery. Predictability: Histogram of Postoperative Spherical Equivalent Refraction Relative to the Intended Target This graph is required for all studies, including those in cataract populations. As above, the analysis should be done by adjusting the postoperative spherical equivalent (SE) refraction to the intended target refraction. This will be Figure 1C in the Standard Graphs for Cataract Surgery. Stability: Line Plot of Stability of Spherical Equivalent Refraction Whereas stability is an important outcome measure for corneal refractive surgery procedures, there are few reasons for refractive instability after cataract surgery. Therefore, this graph will be excluded for cataract studies, although it can be included at the author s discretion if a stability issue is noted. Refractive Cylinder: Histogram of Preoperative and Postoperative Refractive Cylinder This graph is required for all studies to show the distribution of manifest refractive cylinder before and after surgery. However, because of the unreliability of the preoperative manifest refraction in the presence of a cataract, only the postoperative data are necessary for a cataract population. This will be Figure 1D in the Standard Graphs for Cataract Surgery. Vector Analysis of Refractive Cylinder Corneal laser refractive surgery outcomes are rarely reported for spherical corrections only; however, spherical corrections are common for IOL studies in which a monofocal IOL has been used. For any study that did not aim to correct refractive cylinder, these 2 graphs do not apply and can be excluded. If toric IOLs have been used, then these graphs can be considered. For cataract studies, these graphs can be excluded, again due to the unreliability of the preoperative manifest refraction. For RLE studies, as with SE refraction, the validity of analyzing refractive cylinder outcomes is compromised somewhat by the variation of lens power within the population when correcting the same manifest refractive cylinder. However, the same reasoning applies as before that although it might be of interest to evaluate the lens in isolation, the core outcome is the effectiveness of the procedure as a whole. Therefore, these graphs of vector analysis based on manifest refraction will be required for all RLE studies using toric IOLs. Further optional analysis is described in the sections below to specifically analyze the effect of the lens in isolation and the effect of the corneal incision. Reporting Vector Analyses for Lens-Based Procedures The analysis of astigmatism for IOL procedures has greater complexity than for corneal laser refractive surgery, and there are differences between using monofocal and toric lenses. This analysis can be cumbersome and nearly prohibitive for some studies, especially retrospective analyses. The following section describes the different permutations and the analysis that is available in each instance. Corneal Versus Lens Procedures The most obvious difference with lens surgery is that refractive cylinder is influenced by both the IOL and the corneal incision, and these have to be analyzed independently. Therefore, both the Journal of Refractive Surgery and the Journal of Cataract & Refractive Surgery will now encourage a separate analysis of the astigmatic effect of the corneal incision. This can include: 1. The location of the incision site (and whether this was the same for all patients or different, such as always placing the incision at the steep meridian). 2. A histogram of the corneal astigmatism before and after surgery to provide an overall picture of the change in corneal astigmatism. 3. The mean magnitude (and standard deviation, minimum, maximum) of the flattening effect (FE) to provide the astigmatic change at the meridian of 220 Copyright SLACK Incorporated

the incision because this is the relevant value when calculating the IOL power. 3-6 4. The mean magnitude (and standard deviation, minimum, maximum) of the surgically induced astigmatism (SIA) vector to provide the total astigmatic change, including both the flattening and torque effects (the SIA will therefore always be larger than the FE magnitude). Because the torque effect only acts to rotate the astigmatism and does not change the power, using the SIA magnitude for the IOL power calculation will overestimate the astigmatic effect of the corneal incision. The torque effect can be specifically reported if a significant torque effect is found because this would affect the optimal orientation of the lens. 7 Further analysis can be included where relevant at the author s discretion. For example, the summated vector mean (SVM) may also be reported, but only for populations in which the incision site was consistent for all eyes treated. If the incision site varied between eyes, the SVM will lose any clinical relevance because the multiple incision sites will influence the averaging. In such studies where the incision site varied, a more complex analysis could be performed to investigate the difference between incision sites or comparing the effect relative to the location of the steep or flat meridian. This kind of advanced analysis was performed in a recent study by Alpins et al., 8 who found some fascinating results. The FE was found to be greater for superior incisions than for temporal incisions, was greater for right eyes than for left eyes, was greater when the incision was performed at the steep meridian of the astigmatism, and was almost astigmatically neutral when performed at the flat meridian. Another example of more complex analysis is the recent study by Chang et al., 9 who found that corneal astigmatic effect of the incision was influenced by the magnitude and meridian of the preoperative corneal astigmatism, as well as by the size of the incision. Toric IOLs: Guide for Advanced Graphical Analysis As described above, in a procedure in which the natural lens has been removed, the refractive outcome can be analyzed as either the procedure as a whole or based on the lens in isolation. To achieve this, further vector analysis can be done using the hybrid method as described by Alpins et al. 10 In this method, the preoperative astigmatism is taken to be the corneal astigmatism after including the predicted effect of the corneal incision, so that the refractive cylindrical correction of the IOL is isolated from the astigmatic effect of the corneal incision, which has already been handled separately and described above. The postoperative astigmatism is Journal of Refractive Surgery Vol. 33, No. 4, 2017 then taken to be manifest refractive cylinder (adjusted to the corneal plane). The target induced astigmatism is provided by the IOL power calculated at the corneal plane, and the SIA can be calculated as the difference between the preoperative corneal astigmatism and postoperative refractive cylinder, each as defined above. The vector analysis can then be performed as normal using these values. Corneal Incisions for Astigmatic Correction at the Time of Lens-Based Surgery Corneal incisions in the form of limbal relaxing incisions 11,12 or astigmatic keratotomy 13,14 are often used in combination with IOL procedures for reduction of corneal astigmatism. Corneal incisions are used most commonly with non-toric IOLs, but in some cases these are used together with toric IOLs. With the advent of femtosecond laser assisted cataract surgery, intrastromal astigmatic keratotomy is gaining popularity. 15,16 In terms of analyzing the astigmatic change, the inclusion of corneal incisions introduces another slightly different set of analyses. Given that the change is on the cornea, graphs H and I should ideally be included but analyzed based on the change in corneal astigmatism. In studies including corneal incisions, the change in astigmatism would likely be a main focus, in which case a more comprehensive vector analysis (both corneal and refractive) might be expected. Certainly complex analysis is necessary in studies in which both corneal incisions and toric IOLs are used, but this is outside of the scope of this editorial. As with the previous 2014 editorial, there are no restrictions on astigmatic analysis included in addition to minimum standard recommendations. Total Corneal Astigmatism The confounding influence of posterior corneal astigmatism when not aligned with anterior corneal astigmatism has been identified as an important factor to consider for toric IOL power calculation. 17,18 The use of total corneal astigmatism has also been shown to improve the correlation of corneal astigmatism with manifest refractive cylinder 19 and improve the prediction of the residual cylinder after toric IOL implantation. 20 The use of measurements of total corneal astigmatism is therefore emerging as an improved method for both IOL power calculation and analysis of change in corneal astigmatism. It is outside of the scope of this editorial to make specific recommendations on how posterior or total corneal astigmatism should be analyzed, and current analyses are based on anterior corneal astigmatism; however, authors are encouraged to include posterior corneal astigmatism as part of the analysis if they wish. 221

Summary Although there are inherent differences between corneal and IOL-based refractive surgery procedures, the aim of the procedure is the same in each case, so it makes sense that the 9 standard graphs be applied unaltered to corneal laser refractive surgery, phakic IOL implantation, and RLE. Cataract surgery is a different scenario that warrants a simplified version of the standard graphs. By considering these issues, we hope to standardize the quality of reporting for lens-based procedures from its current level and strive to encourage authors to go beyond these basic graphs to match the standard of studies reporting outcomes of corneal refractive surgery that now have good adherence to the standard graphs. Only by homogenizing the reporting of outcomes as a first step can we hope to glean comparative information among published studies. LINK TO STANDARD GRAPHS ON WEBSITE http://www.healio.com/ophthalmology/journals/jrs/ refractive-outcome-graphs-visual-acuity-conversion REFERENCES 1. Reinstein DZ, Waring GO 3rd. Graphic reporting of outcomes of refractive surgery. J Refract Surg. 2009;25:975-978. 2. Reinstein DZ, Archer TJ, Randleman JB. JRS standard for reporting astigmatism outcomes of refractive surgery. J Refract Surg. 2014;30:654-659. Erratum in: J Refract Surg. 2015;31:129. 3. Alpins NA. Vector analysis of astigmatism changes by flattening, steepening, and torque. J Cataract Refract Surg. 1997;23:1503-1514. 4. Borasio E, Mehta JS, Maurino V. Torque and flattening effects of clear corneal temporal and on-axis incisions for phacoemulsification. J Cataract Refract Surg. 2006;32:2030-2038. 5. Kaufmann C, Peter J, Ooi K, Phipps S, Cooper P, Goggin M. Limbal relaxing incisions versus on-axis incisions to reduce corneal astigmatism at the time of cataract surgery. J Cataract Refract Surg. 2005;31:2261-2265. 6. Lever J, Dahan E. Opposite clear corneal incisions to correct pre-existing astigmatism in cataract surgery. J Cataract Refract Surg. 2000;26:803-805. 7. Song W, Chen X, Wang W. Effect of steep meridian clear corneal incisions in phacoemulsification. Eur J Ophthalmol. 2015;25:422-425. 8. Alpins N, Ong JK, Stamatelatos G. Asymmetric corneal flattening effect after small incision cataract surgery. J Refract Surg. 2016;32:598-603. 9. Chang SW, Su TY, Chen YL. Influence of ocular features and incision width on surgically induced astigmatism after cataract surgery. J Refract Surg. 2015;31:82-88. 10. Alpins N, Ong JK, Stamatelatos G. Refractive surprise after toric intraocular lens implantation: graph analysis. J Cataract Refract Surg. 2014;40:283-294. 11. Budak K, Friedman NJ, Koch DD. Limbal relaxing incisions with cataract surgery. J Cataract Refract Surg. 1998;24:503-508. 12. Müller-Jensen K, Fischer P, Siepe U. Limbal relaxing incisions to correct astigmatism in clear corneal cataract surgery. J Refract Surg. 1999;15:586-589. 13. Maloney WF, Grindle L, Sanders D, Pearcy D. Astigmatism control for the cataract surgeon: a comprehensive review of surgically tailored astigmatism reduction (STAR). J Cataract Refract Surg. 1989;15:45-54. 14. Kershner RM. Keratolenticuloplasty: arcuate keratotomy for cataract surgery and astigmatism. J Cataract Refract Surg. 1995;21:274-277. 15. Day AC, Lau NM, Stevens JD. Nonpenetrating femtosecond laser intrastromal astigmatic keratotomy in eyes having cataract surgery. J Cataract Refract Surg. 2016;42:102-109. 16. Chan TC, Cheng GP, Wang Z, Tham CC, Woo VC, Jhanji V. Vector analysis of corneal astigmatism after combined femtosecond-assisted phacoemulsification and arcuate keratotomy. Am J Ophthalmol. 2015;160:250-255. 17. Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L. Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg. 2012;38:2080-2087. 18. Visser N, Bauer NJ, Nuijts RM, et al. Residual astigmatism following toric intraocular lens implantation related to pupil size. J Refract Surg. 2012;28:729-732. 19. Alpins N, Ong JK, Stamatelatos G. Corneal topographic astigmatism (CorT) to quantify total corneal astigmatism. J Refract Surg. 2015;31:182-186. 20. Savini G, Naeser K. An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Invest Ophthalmol Vis Sci. 2015;56:827-835. Erratum in: Invest Ophthalmol Vis Sci. 2015;56:2303. 222 Copyright SLACK Incorporated