Safe Switching with Safe Contactors

Similar documents
Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Multi-functional safety relay modules PROTECT SRB-E

Type: DILM12 10(24VDC) Article No.:

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Type: DILM25 10(24V50HZ) Article No.:

Ordering details. Approval. Classification

Datasheet - SRB301LC 24VAC/DC

Minicontactorrelay,2NO/2NC,DCoperated

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Datasheet - SRB-E-201ST

ALLEN BRADLEY TIMING RELAY

Safety Light Curtains GuardShield

Type MG-6 Auxiliary Relay Class 1E

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Safety Light Curtain Orion1 Extended

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Safety Light Curtains

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

SPECIFIC TECHNICAL CRITERIA

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

AC1036. Definite Purpose Contactors

Magnecraft Power Relays

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

High performance circuit breakers

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

Signal conditioning instruments

User Manual. SafeShield Safety Light Curtain Hardware

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Level 2 Digital Electronics 2 ( )

Inductive sensor BI1.5-EG08K-Y1

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Tech Support: Customer Service: General Tech Questions: Tech Docs:

R&S ZN-Z154 Calibration Unit Specifications

Selection guide siemens.com/sirius-modular-system

Electrical connection

Electrical connection

Bulletin 190 IEC Modular Starter System

A V 50Hz / V 60Hz

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Type Contact form Model

Safety Light Curtain C 4000 Basic/Micro

Inductive sensor NI10-M18-Y1X-H1141

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

MODEL OVERVIEW GUILLOTINES

Data Sheet Definite Purpose Contactors Ex9CK Series

Operating instructions Electronic preset counter Type series 717

COVER PAGE FOR TEST REPORT

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Operating Instructions

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

SQM40/41 Actuators for air and gas dampers

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

SIM 5 series Lamp Kit

Inductive sensor NI3-EG08K-Y1-H1341

Circuit-Breakers for Motor Protection Series 8523/8

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Sales guideline for PROTECT SELECT Version 1.0 of

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

R&S ZN-Z85 Switch Matrix Specifications

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

istep STEPPER MOTOR PUMP

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

EX-IQ-Box Digital Signal Interface Module Specifications

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Safety Light Curtain C 4000

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Gear Pump Units For single-line centralized lubrication systems

X-ray inspection system Dymond

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Digital Input Modules for Compact FieldPoint

Transcription:

DILMS Safety Contactor www.eaton.eu Safe Switching with Safe Contactors DILMS Safety Contactors

The DILMS Safety Contactor is Safe, Proven and Stands out The auxiliary contact blocks of Eaton s DILMS safety contactor are now permanently front-mounted. Their conspicuous yellow color make them highly visible and easily identifiable. Monitoring of open hazardous areas through light curtains Safe operation with twohand control Monitoring of movable guards via guard monitoring without interlock/guard locking Emergency-stop circuits Safety first! Eaton s DILMS safety contactor is the reliable choice for safety-relevant applications. In these applications, user safety is always the most important aspect. By combining a proven technology with the most up-to-date safety standards, the DILMS safety contactor is the right choice for any installation. Features All versions of the DILMS safety contactor are equipped with a top-mounted auxiliary contact that is non-detachable. The integrated mirror contacts and interlocked opposing contacts make this contactor even safer. The contactor s yellow cover allows for quick and easy identification. The built-in inspection window directly above the switch-position indicator makes it possible to monitor the operating status at any point in time. This reliably prevents the contactor from being activated manually. Comprehensive & Targeted The DILMS range of contactors comprises four different sizes and covers the power range between 7 and 150 A. The DILAS safety relay, available in three different coil voltages, rounds out Eaton s product range in this area. The following drive options are available: 1. 110V 50Hz, 120V 60Hz 2. 230V 50Hz, 240V 60Hz 3. 24VDC The safety contactors have been approved and certified for global use (including CE, UL, CSA, and SUVA certification). At a Glance Safe status monitoring of the contactor (inspection window) manual activation is not possible Eligible to be used for Emergency-stop application with controlled start (category 4) Reliable and self-monitoring machine-control circuits Interlocking opposing contacts, in line with IEC 60947-5-1, Annex L Mirror contacts in line with IEC 60947-4-1, Annex F Highlighted in yellow (RAL1004) Reliable screw terminals Top-mounted and non-detachable auxiliary contact (at the front) SUVA - Certified EATON FL34004 Safety Contactors Flyer January 2018

Safety Applications Example Applications and safety related characteristics EN ISO 13849 Safety of machinery Safety-related part of control systems EN ISO 12100 Safety of machinery Risk assessment and risk reduction Functional and safety requirements for safety related control systems IEC 60204 Safety of machinery Electrical equipment of machines IEC 62061 Safety of machinery Functional safety of safety related electrical, electronic and programmable electronic control systems 3 Stages to reduce the risk of a machine Risk parameters to determine the required PL are the severity of injury, the frequency and/or exposure to hazard and the possibility of avoiding hazard or limiting harm in accordance to EN ISO 13849-1. Functional safety During it s entire life cycle a machine poses danger to man, machine and environment. It is therefore necessary to identify these dangers already when the machine is designed and reduce them by means of suitable measures. The EU Machinery Directive 2006/42/EC stipulates that a machine should not pose any danger. However, as there is no 100% safety in engineering, the aim is to reduce these dangers to a tolerable level or residual risk by means of risk reduction measures. The overall safety of a machine defines the state in which it can be considered as being free of unwarranted risks to persons or as free of danger The functional safety is part of the overall safety of a system which depends on the correct functioning of the safety related systems, other technology and external risk reduction facilities The SIL performance is driven by the frequency and duration, the probability of hazard and the avoidance resulting in the risk class CL. Performance Level ISO EN 13849-1 PLr Risk parameter 1 a = low risk... e = high risk S1 S2 F1 F2 F1 F2 a b c d e S S1 S2 F F1 F2 P Severity of injury Slight (Normally reversible injury) Serious (Normally irreversible injury or death) Frequency and/or exposure to hazard Seldom-to-less-often and/or exposure time is short Frequent-to-continous and/or exposure time is long Possibility of avoiding hazard or limiting harm Possible under specific conditions Scarcely possible Safety Integrity Level IEC 62061 Frequency and duration, Fr 1 hour 5 > 1h - day 5 > 1 day - 2 weeks 4 > 2 weeks - 1 year 3 > 1 year 2 Probability of hzd. event, Pr Avoidance, AV Very high 5 Likely 4 + Possible 3 + Impossible 5 = Rarely 2 Possible 3 Negligible 1 Likely 1 Class CL 11-13 The result in the example is SIL 3: Consequences Severity Class CI S 3-4 5-7 8-10 11-13 14-15 Death, losing an eye or arm 4 SIL2 SLI2 SIL2 SIL3 SIL3 Permanent, losing fingers 3 AM SIL1 SIL2 SIL3 Reversibel, medical attention 2 AM SIL1 SIL2 Reversibel, first aid 1 AM SIL1

Safety Applications Example Applications and safety related characteristics Sample Application Emergency Stop dual channel with safety relay ESR5 E-stop Safety relay ESR5 M22 Push buttons Safety Contactor XTSE/ DILMS Safety Contactor XTSE/ DILMS Safety related characteristics Independent of the application, safety related characteristics of the components are necessary to calculate the Performance Level or Safety Integrity Level. Tools like SISTEMA from the Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA) provide assistance in the evaluation of safety-related control components and simplifies risk assessment analysis. Applicable values for safety contactors are B10/ B10d. The Eaton safety contactors provide up to 1.3/ 1.7 million switching cycles until 10% of tested and worn components have failed. Cat B 1 2 3 4 PL a b c d e SIL 1 2 3 En ISO 13849-1 B10d EN 62061 B10 DILMS7-12/XTSE007B-012B 1.782.229 1.336.672 DILMS17-32/XTSE018C-032C 966.617 724.963 DILMS40-65/XTSE040D-065D 1.341.161 1.005.871 DILMS80-95/XTSE080F-095F 1.058.707 772.856 DILMS115-150/XTSE115G-150G 1.705.268 1.278.951 M 3~ Fast and secure detection Safe monitoring and processing Reliable shutdown Input Logic Output EATON FL34004 Safety Contactors Flyer January 2018

Overview of Data Complete units Safety control relay DILAS Current AC-15 [A] Auxiliary 230 V 400 V contacts 110 V 50 Hz, 120 V 60 Hz 230 V 50 Hz, 240 V 60 Hz DC operation 24 V DC 4 4 4NO,4NC DILAS-44 (110V50HZ, 191700 DILAS-44 (230V50HZ, 191739 DILAS-44 (24VDC) 191760 4 4 4NO,4NC DILAS-R44 (110V50HZ, 191732 DILAS-R44 (230V50HZ, 191753 DILAS-R44 (24VDC) 191720 Safety contactors DILMS Current output A kw Auxiliary contacts 7 3 2NO,3NC 9 4 2NO,3NC 12 5.5 2NO,3NC 7 3 9 4 12 5.5 18 7,5 2NO,3NC 25 11 2NO,3NC 32 15 2NO,3NC 18 7,5 25 11 32 15 1) 40 18,5 2NO,2NC 50 22 2NO,2NC 65 30 2NO,2NC 80 37 2NO,2NC 95 45 2NO,2NC 110 V 50 Hz, 120 V 60 Hz DILMS7-23 (110V50HZ, DILMS9-23 (110V50HZ, DILMS12-23 (110V50HZ, DILMS7-R23 (110V50HZ, DILMS9-R23 (110V50HZ, DILMS12-R23 (110V50HZ, DILMS17-23 (110V50HZ, DILMS25-23 (110V50HZ, DILMS32-23 (110V50HZ, DILMS17-R23 (110V50HZ, DILMS25-R23 (110V50HZ, DILMS32-R23 (110V50HZ, DILMS40-22 (110V50HZ, DILMS50-22 (110V50HZ, DILMS65-22 (110V50HZ, DILMS80-22 (110V50HZ, DILMS95-22 (110V50HZ, 191701 191702 191703 191733 191734 191735 191704 191705 191706 191736 191737 191738 191707 191708 191727 191728 191729 230 V 50 Hz, 240 V 60 Hz DILMS7-23 (230V50HZ, DILMS9-23 (230V50HZ, DILMS12-23 DILMS7-R23 DILMS9-R23 DILMS12-R23 DILMS17-23 DILMS25-23 DILMS32-23 DILMS17-R23 DILMS25-R23 DILMS32-R23 DILMS40-22 DILMS50-22 DILMS65-22 DILMS80-22 DILMS95-22 (230V50HZ, DC operation 24 V DC 191740 DILMS7-23 (24VDC) 191761 191741 DILMS9-23 (24VDC) 191762 191742 DILMS12-23 (24VDC) 191709 191754 DILMS7-R23 (24VDC) 191721 191755 DILMS9-R23 (24VDC) 191722 191756 DILMS12-R23 (24VDC) 191723 191743 DILMS17-23 191710 191744 DILMS25-23 191711 191745 DILMS32-23 191712 191757 191758 191759 115 55 2NO,2NC DILMS115-22 (RAC120) 191730 DILMS115-22 (RAC240) 191751 150 75 2NO,2NC DILMS150-22 (RAC120) 191731 DILMS150-22 (RAC240) 191752 DILMS17-R23 DILMS25-R23 DILMS32-R23 191724 191725 191726 191746 DILMS40-22 191713 191747 DILMS50-22 191714 191748 DILMS65-22 191715 191749 DILMS80-22 191716 191750 DILMS95-22 191717 DILMS115-22 DILMS150-22 191718 191719 1) 1NO1NC Electronic compatible EATON FL34004 Safety Contactors Flyer January 2018

At Eaton, we are solution-driven, supplying energy to a world that is ever more demanding. With over 100 years of expertise in electrical power management, we have the expertise to see beyond today. Core industries all around the globe rely on Eaton and on our pioneering products, comprehensive solutions and engineering services. Companies know they can always trust our reliable, efficient, and safe power management solutions. Together with our personalized service and support, as well as our forwardlooking attitude, these solutions meet the needs of tomorrow, today. Follow the charge. Visit eaton.eu. Eaton Eaton Industries GmbH Hein-Moeller-Str. 7 11 D-53115 Bonn / Germany 2018 Eaton Corporation All rights reserved Printed in Germany Publication : FL034004EN-EN / CSSC-799 number: 197157 January 2018 The products, information and prices contained in this document are subject to change. The same is true for any errors or omissions. Only the order confirmation and the technical documentation received from Eaton are binding. Photos and illustrations are indicative only and do not serve as proof of any appearance or functionality. Their use in any form must be approved in advance by Eaton. The same applies for brand names (in particular Eaton, Moeller, Cutler-Hammer, Cooper and Bussmann). Eaton s terms of sale, as published on Eaton s websites and included with order confirmations received from Eaton, apply. Eaton is a registered trademark. All other trademarks are property of their respective owners.