EC Series Creativity Accessories Safety and Installation Guide

Similar documents
M1, M2GO and M2PC MIDI PCB Module Installation Guide SMPTE PCB Module Installation Guide

Cyclo DMX HO High Output. user manual

PAR 2 RGBW Zoom User Manual

FiberSource 1 User Manual

X 5 / XC 5 LED STROBE

Site Installation Model MP-8424

Galaxias. Flex LED display. User Manual

Vibratory Deck Sieves 15 in. (380 mm)

Site Installation Model MP-8433

Cyclo Series. user manual. MartinArchitectural

Atomic 3000 LED User Manual

RUSH Scanner 1 LED User Manual

PIXEL BAR 40. user manual 1.0. ELATION PIXEL BAR 40 user manual 1.0

Power Injector 1520 Series

Exterior Projection 500. User Manual

FOSC 450 C6 and D6 Closures

Stage Cyclo User manual

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

TV Lift System Model CL-65 Installation Instructions

Exterior Projection 500. User Manual

MH 2 Wash User Manual

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

MAC Aura XB. User manual

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

RUSH MH 6 Wash. User Manual

Stagebar 54. user manual

C 303W-RF Tri-element Array Microphone Instructions

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

3M Locator Plate N

Installation Instructions

Optical Distribution Box 300 Installation Guide. Version : R0.0

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

3M Distribution Box (DDB)

Exterior Wash 300 Series. User manual

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

USER MANUAL Table of Contents

Hardware installation

G-SPOT MOVING HEAD PROFILE

Photovoltaic Module Installation Manual (IEC)

HD1-DX HDMI Extender

Q-10 USER MANUAL REV. C

Chip3 Inline Ultraslim RGB Multi Pixel

Electric Motorized Projection Screen PowerMax Tension Series

P-10 USER MANUAL REV. A

MH 1 Profile. User Manual. Professional Entertainment Technology

LWX-1. Satellite Weather Radio Module Installation Instructions A

USER AND INSTALLATION MANUAL ENGLISH SWITCHPACK. PART01245 CONTROL GEAR. rev 01-00

Exterior Projection 1000

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

PIXEL NET 4. user manual. ELATION PIXEL NET 4 user manual

Instrukcja montażu. FLEX LED Neon Instalacja

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

1. Before You Begin... 3

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Photovoltaic Module Installation Manual (IEC)

DLP200M 2 Relay Module for Heating and Cooling Plants

FOREST SHUTTLE S / L / M RECEIVER

1 x 10 Component Video with Stereo and Digital Audio Distribution Amplifier over CAT5/6 compatible with AT-COMP300RL AT-COMP10SS

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector Installation Instructions

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

MH 3 Beam User Manual

EWDMX IP. user manual. ELATION EWDMXIP user manual

1440/2880 HP RGB+WW+CW

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

Liner Quattro AC XB RGBW

120cm (4x36 Watt) incl. Splitter Instruction Manual

STROBE 1 5x5 User Manual

COMBINATION UNITS MARCH 2018

C 303-RF Tri-element Array Microphone Instructions

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Home Kit. Model XM101HK

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

User Manual. AtlonA. 1 x 10 VGA with Stereo Audio Distribution Amplifier over CAT5/6 compatible with AT-VGA300RL AT-VGA10SS

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7

LED IP65 Slimline Par RGBWA +UV 7x12W

TeamWork Installation Guide

User Guide. HDMI Active Cable Extender. DVI-7370c

Quick Release Roof-Mount Kit MB700

LC 1140/2140 Video Curtain user manual


AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

INSTALLATION INSTRUCTIONS FOR

E15X-SUB Manual (1.2 EN)

In-Wall Control Mount for ipod Touch

PNP300 / PNP300UN / PNP350

18W Low Energy Dusk-Dawn Bulkhead E-290B

MP Maker Pro Mk.1. Quick Start Guide

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

Medium Box for Cable Termination

HD1-LX HDMI & IR Extender

Installation instructions Cable transit device Roxtec RS ES Ex

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Tube Rotator. User Guide. Version 1.2

Transcription:

EC Series Creativity Accessories Safety and Installation Guide Safety precautions Warning! Before installing Martin EC Series video panels using the accessories described in this guide, read the Safety Information section of the EC Series Safety and Installation Guide. The Guide is supplied with each EC Series flightcase and is also available for download from the Support pages for the EC Series on www.martin.com. Warning! Installation must be carried out by qualified professionals only. Contact your Martin supplier for assistance if you have any questions about how to install this product safely. Warning! The safety and suitability of lifting equipment, installation location, anchoring method, mounting hardware, suspension structures and electrical installation is the responsibility of the installer. All local safety regulations and legal requirements must be observed when installing EC Series video panels. Check that all cables, chains, hoist, trusses and other supporting structures can bear at least 10 times the total weight (panels, clamps, cables, auxiliary equipment, etc.) that they will have to support. If installing overhead, block access under the work area. Warning! EC Series panels must be fastened to a suitable supporting structure and secured against falling with at least one approved secondary attachment as directed in this guide. The Input and Output Connectors described in this guide must not be used to support the weight of an EC Series panel or any other item. An EC Series panel must be supported by either a Martin EC Series Header or the EC Series Panel Clamp described in this guide. Warning! Isolate the installation from AC mains power and ensure that power cannot be reapplied during installation work. Warning! Two-pole neutral fusing. Warning! The supplied rubber caps must remain installed at all times on any unused power and data throughput sockets. Keep unused caps safely and re-install them as soon as an installation is taken down. Warning! No more than one EC Series panel may be suspended from one EC Series Panel Clamp. A maximum of eight (8) EC Series panels in total may be connected to AC mains power in a chain using the throughput and input sockets described in this guide. 2013 Martin Professional A/S. Information subject to change without notice. Martin Professional A/S and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. The Martin logo, the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional A/S or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional A/S or its affiliates or subsidiaries. P/N 35000627, Rev. A

Dimensions Panel Clamp 32 141 80 Input Connector 96 480 125 Output Connector 125 480 96 2

Overview Input Connector A B C A - Power input socket Accepts AC mains power for input to panel. Accepts an Amphenol IP67- rated power input (female) connector. B - P3 video input socket Accepts P3 video signal for input to panel. RJ-45 type. Accepts IP67-rated Amphenol RJF RB 6 Ethernet cable connector. C - Connector locks Lock Input and Output Connectors to panel. D - Clamp fastener handle E - Rigging clamp attachment point For fastening a half-coupler rigging clamp (M12 thread). F - Power throughput socket AC mains power output for relay to other EC Series panels. Accepts an Amphenol IP67- rated power output (male) connector. G - P3 video throughput socket P3 video signal for relay to other EC Series panels. panel. RJ-45 type. Accepts IP67-rated Amphenol RJF RB 6 Ethernet cable connector. EC Series panel D E Output Connector F C G Figure 1: EC Series Creativity Pack overview Introduction The EC Series Creativity Pack consists of the following accessories that must be ordered individually: EC Series Panel Clamp, P/N 90354340 EC Series Input Connector, P/N 90354350 EC Series Output Connector, P/N 90354330 The accessories allow a single EC Series panel to be installed in any orientation, offering creative possibilities for video display. EC Series Panel Clamps allow panels to be fastened to rigging clamps and mounted on trusses or other suitable structures. EC Series Input and Output Connectors allow AC mains power and P3 video data to be input to panels and relayed to other panels. EC Series Creativity Accessories Safety and Installation Guide 3

Physical installation Warning! Follow the directions given in Safety precautions on page 1 of this Guide and in the EC Series Safety and Installation Manual when installing EC Series panels using the Creativity Pack accessories. One single EC Series panel can be installed in any orientation using an EC Series Panel Clamp fastened to the center of the spine and fastened to a truss with a rigging clamp. Preparing panels If installing on a truss, obtain one truss rigging clamp per panel clamp. The rigging clamp must be approved for the weight it will support and have an M12 threaded for fastening to the panel clamp. The rigging clamp must be half-coupler type that completely encircles a chord of the truss. See Figure 2. The Martin Half-Coupler Rigging Clamp, P/N 91602005, is recommended. Obtain at least one safety cable per panel. Safety cables must be approved by an official body such as TÜV as a safety attachment for the weight of all the equipment they secure. To prepare an EC-Series panel for mounting on a truss or support, you first need to install an EC Series Panel Clamp, a rigging clamp and an EC Series Input Connector. If you will need to relay power and data to another panel, you must also install an EC Series Output Connector. 1. See Figure 3. Open the jaws of the panel clamp by loosening the fastener handle. Note the label with the arrow and the word UP on the clamp. Place the jaws around the panel spine midway between the top and the bottom of the panel, with the UP arrow pointing towards the top of the panel. The top of the panel is the end with two guide posts (arrowed). Fully tighten the fastener Figure 2: Martin Half-Coupler Rigging Clamp UP Figure 3: UP orientation for clamp 4

handle. Check that there is no gap between the clamp and the spine and that the clamp is fastened securely to the panel. 2. See Figure 4. Remove the rubber input connections cap from the top of the panel and store it for re-use. 3. Place the panel face down on a soft, flat surface such as a table covered by a mat. Figure 4: Input connections cap 4. See Figure 5. Turn both the locks on an EC-Series Input Connector fully counter-clockwise to the released position. 5. Press the Input Connector onto the top of the panel so that the two guide posts in the top of the panel engage in the corresponding holes in the Input Connector. Turn both Input Connector locks fully clockwise until tight. Check that both locks are correctly engaged and that the Connector is securely locked to the panel. Input Connector Engaged Released Figure 5: Input Connector locks 6. If AC mains power and the P3 video link will be continued to another panel, remove the rubber throughput connections cap from the bottom of the panel and store it for re-use. 7. See Figure 6. Turn both the locks on an EC Series Output Connector fully counter-clockwise to the released position. Press the Output Connector onto the bottom of the panel so that the two guide posts in the top of the Output Connector engage in the holes in the panel. Turn both Output Connector locks fully clockwise until tight. Check that both locks are correctly engaged and that the Connector is securely locked to the panel. Output Connector Engaged Released Figure 6: Output Connector locks Installing the panel on a truss 1. See E in Figure 1. Bolt an approved half-coupler rigging clamp securely to the panel clamp using a grade 8.8 minimum M12 bolt. Martin clamps are supplied with a suitable bolt. 2. Use the rigging clamp to fasten the panel to the truss. 3. Loop an approved safety cable around the truss or other secure anchoring point and through the panel so that it is secured against falling if the rigging clamp fails. EC Series Creativity Accessories Safety and Installation Guide 5

Making connections Warning! Follow the directions given in Safety precautions on page 1 of this Guide and in the EC Series Safety and Installation Manual when connecting EC Series panels using the Creativity Pack accessories. Warning! Do not connect more than eight (8) EC Series panels in total to AC mains power in one interconnected chain. Warning! Make sure that all unused sockets on panels and on Input and Output Connectors remain sealed with their waterproof caps at all times. Warning! Support the weight of cable runs so that no strain is placed on connections. AC mains power connections EC Series panels accept AC mains power at 200-240 VAC, 50/60 Hz, from one of the following three-wire systems: a single-phase 200-240 V system (live, neutral, ground/earth), or two phases of a 3-phase delta or split-phase mid-point neutral system (phase, phase, ground/earth) that give 200-240 V Power figures are given in the EC Series Safety and Installation Guide. Allow a sensible safety margin when calculating the current headroom required on power distribution circuits for an EC Series installation. EC Series Input and Output Connectors have Amphenol IP-67 rated sockets for power input and throughput (see Figure 1 on page 3). To connect panels to power: 1. Check that the installation is isolated from power. 2. See Figure 1. Unscrew the waterproof cap on the power input socket A and connect a power input cable to it. Suitable cables are available from Martin (see Power input cables on page 7). 3. To relay power to other EC Series panels in a chain, unscrew the waterproof cap on the power throughput socket F and connect a power throughput cable to it. Suitable cables are available from Martin (see Power throughput cables on page 7). Connect the throughput cable to the next power input socket A in the chain. Do not connect more than eight (8) EC Series panels total in one chain that draws AC mains power via the first panel. Support the weight of cables so that no strain is placed on connections. P3 video connections EC Series Input and Output Connectors have an Ethernet socket mounted in an Amphenol IP67-rated reverse bayonet-mount housing for P3 video data input and throughput (see Figure 1 on page 3). RJ-45 plugs installed in Amphenol RJF RB 6 housings or in an indoor environment non-ip-rated standard RJ-45 Ethernet connectors may be used as connectors on the P3 link. Suitable IP67-rated and non IP-rated patch cables in various lengths with suitable connector housings are available from Martin (see P3 video data cables on page 7). Separate connectors are also available for customers who need to produce custom-length cables (see P3 video data connectors on page 7). To connect panels to P3 video data: 1. Check that the installation is isolated from power. 2. Connect an Ethernet patch cable from the P3 system controller s P3 signal output socket to an input socket on a 1GB unmanaged Ethernet Switch. 3. See Figure 1. Connect an Ethernet cable from an output on the Ethernet Switch to the P3 video input socket B. In outdoor or humid environments, an IP67-rated Amphenol RJF RB 6 housing must be installed on the RJ-45 plug. 4. To relay P3 video data to other EC Series panels in a chain, connect an Ethernet cable to the P3 video throughput socket G and connect this cable to the P3 video input socket B on the next panel in the chain. 5. Check that all unused sockets are sealed with their caps. 6. The system is now ready for power to be applied. 7. Set up the panels to display video as described in the P3 system controller s user manual. Dismantling an installation When tearing down an installation, reinstall caps on all sockets. 6

Specifications Related Items Power input cables Mains Power Input Cable, EU, 5.0 m (16.4 ft.).................................... P/N 11521030 Mains Power Input Cable, US, 5.0 m (16.4 ft.).................................... P/N 11521034 Power throughput cables Power Throughput Cable, EU, 1.5 m (4.9 ft.)..................................... P/N 11521031 Power Throughput Cable, US, 1.5 m (4.9 ft.)..................................... P/N 11521033 Power Throughput Cable, EU, 2.5 m (8.2 ft.)..................................... P/N 11521044 Power Throughput Cable, US, 2.5 m (8.2 ft.)..................................... P/N 11521043 Power Throughput Cable, EU, 5.0 m (16.4 ft.).................................... P/N 11521045 Power Throughput Cable, US, 5.0 m (16.4 ft.).................................... P/N 11521046 P3 video data cables Ethernet patch cable, STP, with IP67-rated RJ-45 connectors, 1.5 m (4.9 ft.)............ P/N 11840147 Ethernet patch cable, STP, with IP67-rated RJ-45 connectors, 2.5 m (8.2 ft.)............ P/N 11840148 Ethernet patch cable, STP, with IP67-rated RJ-45 connectors, 5.0 m (16.4 ft.)........... P/N 11840152 Ethernet input cable, STP, Neutrik RJ-45 to Amphenol IP67-rated RJ-45, 30 m (98.4 ft.)... P/N 11840145 P3 video data connectors Amphenol Ecomate Connector Male C016 20H003 100 12......................... P/N 05347205 Amphenol Ecomate Connector Female C016 20D003 100 12....................... P/N 05327243 Amphenol RJF RB 6 Connector.............................................. P/N 05343521 Ordering Information EC Series Panel Clamp..................................................... P/N 90354340 EC Series Input Connector.................................................. P/N 90354350 EC Series Output Connector................................................. P/N 90354330 7

www.martin.com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel: +45 8740 0000 Fax +45 8740 0010 8