Technical Specification Adrian Sweeney Technical and Buildings Manager Office: 01483 739063 Stage Door: 01483 739040 Email: asweeney@glive.co.uk Web: GLive.co.uk 1. Auditorium Capacity Fully seated with 5 rows on the orchestra lift 1031 Fully seated with 4 rows on the orchestra lift 1003 Fully seated with 3 rows on the orchestra lift 975 Fully seated with 2 rows on the orchestra lift 947 Fully seated with 1 row on the orchestra lift 919 Fully seated with no rows on the orchestra lift 891 Fully seated with no seats on floor 851 Fully seated in circle only 393 Maximum capacity with stalls seating retracted 1700 There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated. Mixer Positions For seated events and concerts the FoH mixer position is situated within the first three rows of the Circle seating. M1 is our large mixer position and requires the removal of seat numbers 11-22 in rows BB, CC, DD. This would be 3 rows of seating with 12 seats in each row removed. M2 is our Medium mixer position and requires the removal of seat numbers 15-22 in rows BB, CC, DD. This would be 3 rows of seating with 8 seats in each row removed. M2 M3 is our small mixer position and requires the removal of seat numbers 17-22 in rows BB, CC, DD. This would be 3 rows of seating with 6 seats in each row removed. M3 M4 means no seats have been removed from any of the mixing positions and any mixing required would be from the Control box or from stage. Please note that the mixer position could result in the loss of a maximum of 36 seats from the circle seating block. For standing events and concerts decking can be used to create mixing positions at stalls level. Please see Staging Equipment for information on decking. It may also be necessary to hire barriers for stall level mixing. Please contact Technical Department to discuss.
2. Dimensions Height from stage to grid underside Clear height under galleries Clear width between PS and OP wall Clear width between galleries Stage height from auditorium floor Orchestra pit width Orchestra pit depth Orchestra pit travel Orchestra pit maximum load (dynamic) 10550mm 10550mm 22150mm 19050mm 1100mm 17800mm 4900mm 2400mm 5000kg 3. Flying Please note that G Live is a non-flying House. For purposes of rigging only, all bars and trusses are rigged on chain motors, with 2 different motor control systems dependant on whether bars or trusses are required. Please further note that ACS reflectors are stored on bars in the grid. The reflectors cannot be removed from their storage bars in the grid under any circumstances. Bar Description SWL Dist./mm Length Motor 1A SR Line Array 1000kg -1300 Motor 1B SL Line Array 1000kg -1300 Motor 2 Concert Lighting Bar 1 500kg -250 17.6 Setting line 0 Motor 3 DS Reflector storage not re-moveable 1800kg +500 16m Truss 1 GP20 Truss 1800kg +1600 (DS chord) 14m +2120 (US chord) Motor 4 DS Reflector useable bar 1800kg +2650 16m Motor 5 Concert Lighting Bar 2 500kg +3400 17.6m Motor 6 MS Reflector storage not re-moveable 1800kg +4090 16m Truss 2 GP20 Truss 1800kg +4950 (DS chord) 14m +5470 (US chord) Motor 7 MS Reflector useable bar 1800kg +6200 10m Motor 8 Concert Lighting Bar 3 500kg +7050 17.6m Motor 9 US Reflector storage not re-moveable 1800kg +7690 10m Truss 3 GP20 Truss 900kg +8400 (DS chord) 12m +8920 (US chord) Motor 10 US Reflector useable bar 12m Motor 11 Concert Lighting Bar 4 500kg +9800 10m Motor 12 Full Black 500kg +10500 13.3m 4. Rigging Over stage rigging: There are eight rolling beams with girder trolleys, with a point load of 1Tonne SWL on each point. Over auditorium rigging: There are five I-beams running north - south from stage above the auditorium with girder trolleys, with a point load of 1Tonne SWL on each point.
5. Stage Equipment 36 x 2m x 1m Maltbury MetroDeck staging units 12 x 3500mm wide x 9000mm drop NDFR black wool serge legs 2 x 7000mm wide x 9000mm drop NDFR black wool serge tabs with 50% fullness 6. Music Stands 1 x conductor s podium (1m x 1m, c/w DS rail) 60 x Manhasset music stands 140 x fabric covered chairs 7. Access Equipment 1 x Tallescope max platform height 7.5m 1 x 12 rung Zarges Industrial Skymaster 1 x 8 rung Zarges Trade Skymaster 2 x 6 rung Zarges 8. Stage Management 1 x Stage Manager remote prompt desk.desk complete with cue light control, calls to all areas and working light control. 12 x Tecpro BP111 single circuit beltpacks 12 x Tecpro SMH210 single muff headsets 8 x cue light outstations 9. Lighting Equipment 1 x Avolites Pearl Expert running Titan v4.0 142 x 3kW dimmers 16 x 5kW dimmers 28 x 3kW non-dims 12 x 5kW non-dims Please note that all 3KW dimmer outlets are 16A sockets and 5KW are 32A sockets. Socapex multicores are also available with 16A breakout sockets. 10 x ETC Source 4 10 750W profile 10 x ETC Source 4 19 750W profile 4 x ETC Source 4 36 750W profile 10 x ETC Source 4 15-30 750W profile 4 x Selecon Rama 150 7-50 1200W Fresnel 10 x Selecon Arena 7-60 2000W Fresnel 40 x ProCan III PAR cans c/w CP62 2 xrobert Julliat Aramis 2500W followspots Each Profile comes with a hook clamp, safety bond, colour frame and four shutters. Each Fresnel s comes with a hook clamp, safety bond, colour frame and four leaf barn doors. All PAR cans come with a hook clamp, safety bond and colour frame. Also available are: 10 x ETC Source 4 gobo holders (GH59) for B size gobo 4 x ETC Source 4 adjustable iris A selection of socapex multicore cable and breakout spiders are available, along with 16A TRS, 16A -15A adapters and DMX cable. Please ask Technical Department for details.
10. Sound Equipment 1 x Allen & Heath GL3800 32 mono channel mixing desk 1x Yamaha O1V 96i 16 channel mixing desk 1 x Denon DNC635 CD Player 1 x Tascam MD350 MD player 1 x Yamaha SPX2000 1 x BSS FCS966 GEQ 1 x Klark Teknik compressor/gate SQ1D 8 channel processor Stage left and stage right FoH Line Array consists of the following: 8 x Martin Audio W8LM cabinets and 2 x Martin Audio W8LMD cabinets each side. Suspended from Motor bars 1A (SR) and 1B (SL). Please see above for distance from stage. 4 x Martin Audio WS218 subs and 6 x Martin Audio DD6 front fills are also available on request 4 x Martin Audio LE1200 monitors 4 x loudspeaker stands 4 x microphone floor stands 6 x microphone boom stands 2 x microphone table stands 8 x AKG C 391 B condenser microphones 4 x Shure SM58 dynamic microphones 4 x Shure SM57 dynamic microphones 6 x EMO 520 single passive DI boxes All line array and sub speakers are driven by Powersoft M Series amplifiers and managed by Bi- Amp Nexia SP processing. All other speakers are driven by QSC amplifiers. 11. Temporary Electrical Supplies 400A 3Ø temporary lighting supply located upstage left and comprising of: 1 x 200A 3Ø supply terminated with PowerLock source connectors, protected by key switchable variable ELCB 2 x 125A 3Ø supply terminated with Cee Form socket, protected by 30mA 30mS RCD 2 x 63A 3Ø supply terminated with Cee Form socket, protected by 30mA 30mS RCD 200A 1Ø temporary sound supply located upstage left and comprising of: 2 x 125A 1Ø supply terminated with Cee Form socket 2 x 63A 1Ø supply terminated with Cee Form socket All above sound supplies are protected by key switchable variable ELCB 63A 1Ø temporary sound supply located in the grid on SR terminated with Cee Form socket 200A 3Ø temporary outside broadcast supply located upstage right and comprising of: 2 x 125A 3Ø supply terminated with Cee Form socket, protected by key switchable variable ELCB 3 x 63A 3Ø temporary rigging supplies located in the grid, two on SL and one on SR terminated with Cee Form socket
12. Dressing Rooms No Location Accommodation Facilities 1 Stage level 2 persons WC, shower, TV 2 Stage level 2 persons WC, shower, TV 3 Stage level 2 persons WC, shower, TV 4 Stage level 3 persons WC, shower, TV 5 First floor 6 persons Sink 6 First floor 6 persons Sink 7 First floor 6 persons Sink 8 First floor 6 persons Sink Dressing rooms 5-8 are close to toilet and shower facilities. The laundry is located on the first floor and is equipped with 1 x domestic Zanussi washing machine and 1 x domestic Zanussi tumble dryer. Please check with Technical Department regarding usage and any charges. 13. Studio The studio is a completely self-contained space that has its own bar and will accommodate up to 100 people seated in theatre style. Dimensions of the Studio are: Floor space: Height to grid: Height to working light fixtures: 10383mm x 10662mm 4948mm 4643mm Stage lighting consisting of scaffold grid with 36 x 16A sockets distributed on six socket boxes and 12 x 16A sockets at floor level, all hard wired back to 24 channels of Zero 88 Betapack 3 dimmers controlled by Zero 88 Jester 12/24. Sound and light requirements on request. This version was reviewed on 28/02/12 and will be reviewed again in three months.