Nanotechnology Solutions Partner

Similar documents
Nanotechnology Solutions Partner

Nanotechnology Solutions Partner

The Most Accurate Atomic Force Microscope. Park NX-PTR Fully Automated AFM for Accurate Inline Metrology of Hard Disk Head Sliders.

Wafer defects can t hide from

Developing an AFM-based Automatic Tool for NanoAsperity Quantification

B-AFM. v East 33rd St., Signal Hill, CA (888)

Agilent 87075C Multiport Test Set Product Overview

NP-AFM. Samples as large as 200 x 200 x 20 mm are profiled by the NP-AFM system, and several stage options are available for many types of samples.

Standard Operating Procedure of nanoir2-s

Figure 1: AFM image of a Tip-check sample

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

In-process inspection: Inspector technology and concept

EXPRESSION OF INTREST

Advanced Test Equipment Rentals ATEC (2832)

Revolutionary AOI Technology, Unbelievable Speed World's Fastest and Most Accurate 3D SPI

Scanning Probe Microscope Training. Wenhui Pang

TT-2 AFM. This compact, second. generation tabletop Atomic. Force Microscope has all the. important features and benefits. expected from a light

Electron Beam Technology

SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University

Scanning System S-2100

Keysight Technologies Intrinsic Contact Noise: A Figure of Merit for Identifying High Resolution AFMs. Application Note

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Figure 2: components reduce board area by 57% over 0201 components, which themselves reduced board area by 66% over 0402 types (source Murata).

Figure 1. MFP-3D software tray

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Preface. The information in this document is subject to change without notice and does not represent a commitment on the part of NT-MDT.

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

Standard AFM Modes User s Manual

About... D 3 Technology TM.

TT-AFM. For: up to 1 X 1 X 1/4. Vibrating, Non Vibrating, Phase, LFM. 50 X 50 X 17 μ, 15 X 15 X 7 μ. Zoom to 400X, 2 μ resolution

DIRECT DRIVE ROTARY TABLES SRT SERIES

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

R-1580A Microwave Downconverter. Product Brochure

Agilent 81600B Tunable Laser Source Family

Quick Start Bruker Dimension Icon AFM

Ultrasonic Testing adapts to meet the needs of the Automotive Tube Industry

Perfecting the Package Bare and Overmolded Stacked Dies. Understanding Ultrasonic Technology for Advanced Package Inspection. A Sonix White Paper

UV Nanoimprint Tool and Process Technology. S.V. Sreenivasan December 13 th, 2007

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

YXLON Cougar EVO PLUS

Nova NanoSEM Superior Imaging and Analytical Performance

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

All-in-one solutions For applications with imaging challenges, we offer a wide range of TDI solutions.

-Technical Specifications-

TT AFM LongBeach Procedures and Protocols V2.1

LD OEM/LD PDS/LD PeCo

Characterization and improvement of unpatterned wafer defect review on SEMs

University of MN, Minnesota Nano Center Standard Operating Procedure

LASER SCANNING PRODUCT GUIDE. Industrial Holographic and Conventional Laser 1D, Omnidirectional Bar Code Scanners

DML 5000 Inline Laser Thickness Measurement for Quality and Production Assurance

Revitalize Indoor Content Delivery through Clearer and More Vivid Picture Presentation

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

SC24 Magnetic Field Cancelling System

MEMS METROLOGY USING A STROBED INTERFEROMETRIC SYSTEM

Signal Stability Analyser

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Precision Nano Displacement System (PNDS)

BTC and SMT Rework Challenges

3. Fibre Gripper - Includes a simple adaptor to fit 70mm glass slides to the OFDA 4000 for measuring fibre snippets (not shown)

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

SC24 Magnetic Field Cancelling System

SMT Encoder for High Performance, High Volume Designs Small Size High Resolution Low Cost ChipEncoder Reflective Surface Mount Encoder Features

Magnetic Force Microscope (MFM)

HyPrecision Waterjet. Optimizing waterjet performance

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

OM2000N INSTALLATION MANUAL

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

METROTOM. Visible Metrology.

EMC-Scanner. HR-series

I n d u s t r i a l M e t r o l o g y f r o m C a r l Z e i s s. METROTOM. Visible Metrology.

HSR-1 Digital Surveillance Recorder Preliminary

Digital BPMs and Orbit Feedback Systems

LD-V4300D DUAL STANDARD PLAYER. Industrial LaserDisc TM Player

Auto classification and simulation of mask defects using SEM and CAD images

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

CORONA & PLASMA FOR NARROW WEB

ZEBRA SE960HP OEM MINIATURE HIGH PERFORMANCE 1-D SCAN ENGINE. FEATURES Large working range from near contact to 100 in./254 cm. Small and lightweight

World s smallest 5MP stand-alone vision system. Powerful Cognex vision tool library including new PatMax RedLine and JavaScript support

Introduction. An AFM/NSOM System with Fluorescence Lifetime Imaging. Application Note

HyPrecision Waterjet. Optimizing waterjet performance

Advanced Sensor Technologies

Tape scales or glass scales for a wide range of applications. Linear or rotary. Resolutions from 5µm to 1.2nm.

HOT LINKS Trade Show Schedule ISO Certification Contact

STANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM

The Transition to Patterned Media in Hard Disk Drives

TR7500 SIII SERIES. AutomAted optical InsPeCtIon

Model: AV D Keyboard Controller. User Manual. Please Read this User Manual throughout before using.

Spectroscopy Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

AFM Standard Operating Procedure

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

MILLENNIA. The Benchmark In Diode-Pumped Solid-State Lasers.

RECOMMENDATION ITU-R BT.1201 * Extremely high resolution imagery

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

General Specifications

ABRS Series. Air-Bearing Rotary Stage. Direct-drive, slotless brushless servomotor. Zero cogging motor for outstanding velocity stability

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Transcription:

Nanotechnology Solutions Partner Park Systems Corp. KANC F, Iui-Dong 96-1, Suwon, Korea 3-27 Tel. +82-31-56-68 Fax. +82-31-56-685 www.parkafm.co.kr Park Systems Inc. 3 Olcott St. Santa Clara, CA 955 Tel. +1-8-986-111 Fax. +1-8-986-1199 www.parkafm.com Park Systems Japan. NK Dai-ichi Bldg. 1F 1-17-1 Kanda-Nishikicho, Chiyoda-ku, Tokyo, 11-5 Japan Tel. +81-3-3219-11 Fax. +81-3-3219-12 www.parkafm.co.jp Park Systems Singapore. 33, Ubi Avenue 3, #7-7 Vertex Tower A Singapore 8868 Tel: +65-663-77 Mobile: +65-9821-8868 www.parkafm.com 211 Park Systems Corp. All rights reserved.

AUTOMATIC DEFECT REVIEW Decoupled XY & Z Scanners Automatic Defect Review AFM for Hard Disk Media and Substrates The is a general automated industrial XE-series AFM, with features specifically designed to address hard disk media, substrate analysis, and other industrial applications. With capabilities Automatic Defect Review (ADR) and Sub-nano Roughness Analysis, the combines the superb performance of the XE-series with the high throughput and high accuracy demanded by the hard disk media industry and beyond. Park Systems is an automatic defect review AFM that speeds and improves the way defects in HDD substrates and media are identified, scanned, and analyzed. BENEFIT PROBLEMS For researchers working with in hard disk media and other flat substrates, the process of identifying nanoscale defects is time consuming with conventional tools, hindering throughput. The new significantly increases throughput for the defect review process; test runs with real defects demonstrate a 1x increase in throughput for defect review in an automated process when compared with more traditional methods of defect review. SUB-NANO ROUGHNESS PROBLEMS PARK SYSTEMS SOLUTION Suppliers to the HDD industry are developing ultra-flat substrates to address the ever-increasing need for reduced slider flying height. However, there has never been a metrology tool capable of providing accurate and reliable measurements for the sub-nanoscale roughness of these substrates. PARK SYSTEMS SOLUTION By delivering the industry lowest noise floor (less than.5 A) and combining it with True Non-Contact Mode? the makes it possible to acquire consistent, repeatable, and reproducible sub-nanoscale roughness measurements. 211 Park Systems Corp. All rights reserved. 1 2 3 Artifact Free Metrology by Crosstalk Elimination Unique decoupled XY scanning system provides a flat scanning stage Flat and linear XY scan removes artifacts from background curvature Accurate feature measurements with industry leading gauge statistics Superior tool to tool matching True Non-Contact Mode and Longer Tip Life Reduces Cost of Ownership 1 times or longer tip life for general purpose & defect imaging Less tip wear for prolonged high-quality and high-resolution imaging Minimized sample damage or modification Immunity from parameter-dependent results observed in tapping imaging Automatic Defect Review for Media and Substrates Automated survey scan of defects mapped by optical inspection tools Automated zoom-in scan of specified defects Automated profiling of imaged defect types Automated analysis of imaged defects HGA fixture and sample tilting stage (optional) Nanotechnology Solutions Partner Trusted partnership with customers to meet the fast changing requirements Application specific solutions that maximize throughput Modular software and hardware platform enable rapid response BENEFIT The makes it possible for the substrate & media manufacturers to monitor the flattest substrates being developed for the HDD industry. 2-3 -

APPLICATION FEATURES 2 1 2 3-2 - -6 1 2 3 8-1 2 3 1 2 3 8-1 2 3 1 2 3 d2 Candela Map with Defect Coordinates r1 q1 d3 d1 reference point Automated Search Scan & Zoom-in Scan Defect Coordinates Remapped in the AFM d2 d3 d1 reference point Transferring Candela Defect Maps to AFM Utilizing a proprietary remapping technique, the defect map obtained from a KLA Tencor Candela tool can be accurately transferred to the AFM, allowing full automation for high throughput defect imaging. -1 8..8 1.2 1.6 2-2 -3..8 1.2 1.6 2 Automatic Defect Review for Substrates & Media - -8..8 1.2 1.6 2..8 1.2 1.6 2 1 7.5 5 2.5..8 1.2 1.6 2..8 1.2 1.6 2 Optimized scan parameter allows for a two step scan; a fast, low resolution search scan to find the defect, and then a high resolution zoom-in scan to obtain defect details. Parameters of scan size and scan speed are adjustable to match user s needs. Fully Automated Pattern Recognition Utilizing a powerful combination of high resolution digital CCD camera and pattern recognition software, a fully automated pattern recognition and aligent is made possible for user applications. Using the defect location map provided from a Candela tool, the automatically goes to the defect location and images the defects in two steps; a larger, survey scan image to refine the location and then a smaller, zoom-in scan image to obtain the details of the defect. Automatic Measurement Control pxl 6 2-5 -25 pm 25 Automated software makes the operation effortless. Measurement recipes provide multi-site analysis with optimized settings for cantilever tuning, scan rate, gain, and set point parameters. Industry s Lowest Noise Floor Sub-Nano Roughness Measurements of Substrates & Media Industry s lowest system noise, combined with the innovative True Non-Contact Mode, the most accurate roughness measurement can be obtained for the flattest of the substrate and media samples details of the defect. To detect the smallest sample features and image the flattest surfaces, Park Systems has engineered instruments which hold the industry s lowest noise floor specification of <.5Å. Noise floor data is determined using a zero scan. With the cantilever in contact with the sample surface, the system noise is measured at a single point under the following conditions: x scan, staying in one point.5 gain, in contact mode 256 x 256 pixels l 5 - Decoupled XY & Z Scanners pxl 211 Park Systems Corp. All rights reserved.

2 6 ( CROSSTALK ELIMINATION ( XE ACCURATE AFM RESULTS BY CROSSTALK ELIMINATION (XE) Challenges of Accurate AFM Measurement Artifact Free Imaging A Software flattening leaves residual bow Artifact Free Imaging: Flat XY Scan Without Scanner Bowing The conventional AFM uses a piezoelectric tube for the x-y-z scanner, where x-y motion relies on the bending of the tube. The bending motion, however, introduces background curvature and therefore causes z position errors. Conventional systems regularly use software flattening to hide the background curvature; this can be an impossible task since the amount of curvature depends not only on scan size and scan speed, but also on x-y offset, z position, etc. Therefore, even after software flattening, a flat surface does not look flat as shown in the figure. Feedback Control Low residual bow Results less dependent on scan location Less than 1 9 9 No need for software processing (raw data) Accurate height measurements and sample imaging Flat XY Scan Without Scanner Bowing The Crosstalk Elimination (XE) fundamentally removes the scanner bowing, hence attaining flat XY scan with out-of-plane motion less than 1 regardless of scan locations, scan rates, and scan sizes. It shows no background curvature even on scans of the flattest samples such as that of an optical flat as shown in the figure, also with various scan offsets. Thus, the XE-AFM enables very accurate height measurement and precision nanometrology for the most challenging problems in research and industry. Laser 9 PSPD Highly Linear and Orthogonal XY Scan Mirror Sample Cantilever Non-destructive Scan: Tip and Sample Preservation by Non-Contact AFM 9 A B E C D D 1 Standard (5 x 5 scan),96 x,96 pixel image 9 The flexure XY scanner decouples the X and Y scan motion so that the coupling between X and Y movement is minimized regardless of scan locations, scan rates, and scan sizes. Position sensors provide linear feedback control for the high accuracy and high precision measurements. X-Y-Z Piezo Tube Scanner X Y -X Z X-Y Scan Control The tube scanner is a slow actuator with highly limited Z-scan bandwidth of only 5 Hz or so. Therefore, the Z-servo response is too slow to implement Non-Contact Mode, a critical requirement for preservation of sharp tips and non-destructive imaging of soft biological samples. Non-destructive Scan Less tip wear for prolonged high-resolution imaging Minimized sample damage or modification Immunity from parameter-dependent results Imaging of soft sample surface XE Technology: Park Systems Answer to Accurate AFM Measurement Challenges of accurate AFM measurement calls for a completely new approach in the design of an AFM. Park Systems developed the Crosstalk Eliminated (XE) AFM based on decoupled flexure scanners where the XY scanner only moves the sample and the Z Scanner drives the probe. The XE-AFM fundamentally removes the scanner bowing, hence attaining flat XY scan, and dramatically improves the Z-servo response, resulting in superb tip preservation by True Non-Contact Mode. Mechanical Design Features Advantages Decoupled XY and Z Scanners 2D XY Flexure Scanner High Force Z Scanner Super Luminescent Diode (SLD) 6 l 7 - Decoupled XY & Z Scanners 211 Park Systems Corp. All rights reserved. XY scanner only moves the sample and the Z scanner drives the probe Minimal Z Runout (Out-of-plane Motion) Large Z Servo Bandwidth Low Optical Coherence Flat XY Scan Without Scanner Bow Highly Linear and Orthogonal XY Scan Enabling True Non-Contact Mode Eliminates Optical Interference True Non-Contact Mode is Now a Reality True Non-Contact Mode, one of the distinctive advantages only realized by Park Systems Crosstalk Eliminated (XE) AFM, is a powerful method that enables AFM users to image and measure samples. Longer Tip Life and Less Sample Damage The sharp end of an AFM tip is so brittle that once it touches a sample, it becomes instantly blunt and limits the resolution of an AFM and reduces the quality of the image. U Contact Mode Non-Contact Mode z Distance, Z Repulsive Attractive Total interaction In True Non-Contact Mode, the tip-sample distance is successfully maintained at a few nanometers in the net attractive regime of inter-atomic force. The small amplitude of tip oscillation minimizes the tip-sample interaction, resulting in superb tip preservation and negligible sample modification. µm. 3.5 3. 2.5 2. 1.5 1..5. XE-AFM 2.5 5 7.5 1 12.5 µm 3.7 Before After taking 2 images For softer samples, the tip will damage the sample and also result in inaccuracies of sample height measurements. Consequently, preserving tip integrity enables consistent high resolution and accurate data. True Non-Contact Mode of the XE-AFM superbly preserves the tip, resulting in much longer tip life and less sample damage. The figure, displayed in 1:1 aspect ratio, shows the unprocessed raw data image of a shallow trench isolation sample imaged by the XE-AFM, whose depth is also confirmed by scanning electron microscope (SEM). The same tip used in the imaging of the sample shows no tip wear even after taking 2 images.

AFM SOLUTIONS PARK SYSTEMS RELIABILITY Data Storage HDD-Optimize The HDD-Optimize is the state-of the-art product solution program for the hard disk drive (HDD) industry who, until now, had very limited choices for industrial grade in-line inspection tools. Under the systematic approach of the program, Park Systems ensures rapid aligent and performance of its automated AFM solutions with the specific requirements of its HDD customers, matching the highest resolution AFM in the world with the lowest gauge sigma value for repeatability and reproducibility. Technology leaders in the hard disk drive (HDD) industry have chosen Park Systems as their AFM solutions partner to enable next-generation hard drive design and manufacturing. Sample Range UCL LCL Gage Repeatability and Reproducibility Due to the ever-decreasing size of components, manufacturers now require the highest level of quality control. Park Systems can provide 1 gage σ of less than 1 Angstrom. Part Automation Accuracy Correlation Throughput Cost of Ownership Thanks to its revolutionary platform designed for industrial metrology, the XE-AFM will correlate with any existing Park industrial AFMs that have been previously used for manufacturing, inspection, analysis, or research. System 2 R2 >.95.95 < Slope < 1.5 Accuracy Like Never Before System 1 Shrinking form factors are driving the need to design at the nanoscale level in the hard disk drive. Traditional metrology tools have lacked the accuracy needed for nanoscale design and manufacturing. Park Systems has met this challenge in industrial metrology with enabling breakthroughs. Crosstalk Elimination (XE) enables artifact-free and non-destructive imaging New 3D AFM enables high resolution imaging of sidewall or undercut features Throughput Like Never Before AFMs that have enabled nanoscale design have traditionally not been fast enough for use in production quality control. All that has changed with Park Systems revolutionary gains in throughput enabling AFMs for use in automatic in-line manufacturing. System Uptime Our engineers and scientists adopted the most rigorous industry standard of product development to ensure the highest level of system reliability. The can be seamlessly incorporated as either an inline or offline inspection tool with minimal maintenance requirements. These include 5-8% gain in throughput for defect review of media and substrates, where automated defect identification with raw data and partnership process enables successful defect analysis, and programmable data density for high-throughput feature measurement, where we enable much faster measurement of the tiny writer pole on individual HDD sliders by selectively focusing on critical areas with high-resolution imaging. Cost-Effectiveness Like Never Before Accuracy and throughput in nanometrology must be delivered in a cost-effective solution to move successfully from research to inline manufacturing. Park Systems have met this cost challenge with industrial AFM solutions that address the need for complete automation, faster imaging, and longer tip life. We cut costs by replacing spatially limited optical profilers with high resolution imaging and fully automated AFM, and by replacing slower and expensive SEM with efficient, automatic, and affordable 3D AFM for industrial in-line manufacturing. Also, we significantly lower the cost of ownership with at least 2% longer AFM tip life. The tapping forces of conventional AFMs cause faster tip wear, but our True Non-Contact Mode AFMs maintain tip quality resulting in the lower total cost of ownership. Service & Maintenance Park Systems is committed to the highest level of service and support, and every effort is made to understand our industrial customers needs. We place the utmost importance on meeting promised delivery dates, guaranteed quality, and faithful after-sales service. 8 l 9 - Decoupled XY & Z Scanners 211 Park Systems Corp. All rights reserved.

XEA & OPTIONS SPECIFICATIONS Software & User Interface Footprint XEA - Industrial Automation & Analysis XEA is a system software for automation that carries out the AFM measurement of a sample following the preset procedure written in a recipe file. User-friendly XEA architecture provides flexibility to operator to perform various system-wide functions. Supports auto, semi-auto, and manual mode Editable measurement method for each automated procedure Live monitoring of the measurement process Automatic analysis of acquired measurement data 7 or more 3 82 8 5 or more Control Cabinet Acoustic Enclosure with System XEP Data Acquisition 92 8 All the user controls on AFM measurements are operated through XEP, the data acquisition program. The user-oriented interface provides easy operation of AFM. 3 Simultaneous data acquisition of up to 16 images Maximum 96 96 image size Dedicated Force-distance and Cantilever spring constant calibration I-V spectroscopy with batch processing Script-level control through external program (LabVIEW, C++) XEI Image Processing and Analysis Entrance 1 or more XEI is the AFM image processing and analysis program. The powerful processing algorithms make the analysis easy and streamlined. With its most advanced and versatile imaging features, XE users can obtain essential and critical information from their experiment. Image analysis of line profile, region, 3D rendering Spectroscopy data analysis module (F-d, I-V) Multiple image comparison Directly copy/paste to presentation program Image overlay of two different images Options Double-sided Sample Chuck System Specification AFM and XY Stage Control Electronics Facility Requirements A non-damaging sample chuck allows user to finally analyze both sides of a substrate or media sample. State of the art design allows a firm hold of a substrate or media sample without a vacuum to hold it down. Ionization System 1 l 11 - Decoupled XY & Z Scanners 211 Park Systems Corp. All rights reserved. Non-damaging Customized HGA Fixture HGA fixture can be custom built to firmly fit a specific HGA design provided by the customer, providing the most stable fixture in the industry. The non-damaging fixture allows users to easily load and unload the entire HGA, without causing any damage to the HGA. HGA then can be dismounted, and further tested. Up to 5 HGA samples of the same type can be mounted at the same time. Ionization system effectively removes electrostatic charges. It ionizes the charged objects and is very reliable since the system always generates and maintains an ideal balance of positive and negative ions without causing any contamination to the surrounding area. It also reduces the accidental electrostatic built-in charge that may occur during sample handling. Magnetic Force Microscopy It is vital for HDM manufacturers to study the magnetic domain distributions in a fabricated magnetic structure. Magnetic Force Microscopy (MFM) images magnetic domains by measuring the spatial variation of the magnetic force. Park Systems AFM can acquire both a topographic and magnetic image that correlates to the sample under investigation. Motorized XY stage: travels up to 15 mm 15 mm, 1 resolution Motorized Z stage: ~3 mm Z travel distance ~.8 resolution, <1 repeatability Motorized Focus Stage: 11 mm Z travel distance for on-axis optics Sample Thickness Allowance: up to 2 mm Full scan range Z run-out: < 2, repeatability <1 COGNEX Pattern Recognition: pattern align resolution of 1/ pixel Scanner Performances XY Scanner Range: 1 1 (high voltage mode) 1 1 (low voltage mode) XY Scanner Resolution: 1.5 (high voltage mode <.2 (low voltage mode) Z Scanner Range: 12 (high voltage mode) 1.7 (low voltage mode) Z Scanner Resolution: <.2 Z Scanner Noise Floor: <.5 (w/ Active Vibration Isolation System) Controller Processing Unit: 6 MHz and 8 MIPS Signal ADC & DAC: 16-bit, 5 khz bandwidth, internal lock-in Vibration, Acoustic Noise, and ESD Performances Floor Vibration: <.5 /s (1 Hz to 2 Hz w/ Active Vibration Isolation System) Acoustic Noise: >2 db attenuation w/ Acoustic Enclosure Dimension & Weight Acoustic Enclosure: 82(w) 92(d) 16(h) 6 kg approx. (incl. basic XE-HDD System) Control Cabinet: 8(w) 8(d) 1(h) 16 kg approx. (incl. controllers) System Floor Space: 172(w) 92(d) Ceiling Height: 2 or more Operator Working Space: 2(w) 25(d), minimum (dimension unit: mm) Room Temperature (Stand By): 1 C ~ C Room Temperature (Operating): 18 C ~ 2 C Humidity: 3% to 6% (not condensing) Floor Vibration Level: VC-E (3 /sec) Acoustic Noise: Below 65 db Pneumatics: Vacuum: -6 kpa Power Supply Rating: 1/12 V/ 28~2 V, single phase, 15 A (max) Total Power Consumption: 2 KW (typical) Ground Resistance: Below 1 ohms * Specification for upgrade packages (media, slider, wafer) also available, contact Park Systems for more information