Ten Tec RX320 Control Panel. Operation Manual (V2.0)

Similar documents
Noise Detector ND-1 Operating Manual

FM sensitivity, for 12 db SINAD Frequency Preamp off Preamp one Preamp two

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

DIVERSITY DVB-T RECEIVER (DDR)

W0EB/W2CTX Firmware for the Micro BITX meter Transceiver for NON I2C Release V2.02R

ST-4000 SIGNAL LEVEL METER

LinTronic. TableTop series. Hardware version 6. Updated

Before you can install your LCD TV on the wall, you must fi rst remove the base using the steps below:

USB Smart Power Sensor

KCAT Users Manual 1.1. Generated by Doxygen Wed Jun :41:40

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

CVM-WM300. UHF Wireless Microphone USER MANUAL

User Manual Wireless HD AV Transmitter & Receiver Kit

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER. User s Guide (Please read carefully before using for the first time!)

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

UNFOLD THE BASE. Quick Start Guide CONTENTS INSTALLING LCD TV ON THE WALL

WDP02 Wireless FHD Kit User Manual

ST-4000D SIGNAL LEVEL METER

TV CHANNEL INSTALLATION

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DC-103(1080P)/DC-102(720P) DTV CAM Bare bone

USB Smart Power Sensor

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

DC-099 FPV/UAV DTV CAM Module

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com OPERATION MANUAL. The Best Thing on Cable

PAL B to VGA/ HDTV Tuner Box ID# 051

FRQM-2 Frequency Counter & RF Multimeter

USB Smart Power Sensor

C-MAX. TSG200 Time signal generator TSG200. Time Signal Generator. Manual TSG200. RF Technology Specialist. Version. Revision. SPEC No.

VGA AUDIO AUDIO MATRIX SWITCHER S MANUAL

WiNRADiO. G305 VHF/UHF Receiver. User s Guide

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

DC-103 FPV 1080P Full HD DTV CAM

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

RIGOL. 快速指南 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL Technologies, Inc. All Rights Reserved.

User Guide USING THE REMOTE CONTROL ABOUT THE REMOTE CONTROL. Page 3-2

Scan Converter Quick Installation Guide

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

RA-RS232, RB-RS232. Setup and Installation Guide Addendum For RadioRA RS232 Interface

Wireless Multi-Format input Transmitter to HDMI Receiver Box ID # 718

Operating Instructions

PC/HDTV to Video Scan Converter Operations Manual

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

OTR-3550 FREQUENCY AGILE - F.C.C. COMPATIBLE TELEVISION PROCESSOR INSTRUCTION MANUAL

USB-TG124A Tracking Generator User Manual

VMA ACTIVE MATRIX TFT COLOR LCD MONITOR OWNER S MANUAL INSTALLATION GUIDE

R-1550A Tempest Wide Range Receiver

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

CM-392-Video to HDMI Scaler Box ID#481

The PK Antenna Analyzer

R-1580A Microwave Downconverter. Product Brochure

CAR-5N / CAR-5P Video to RGB Converter for CAR display. Operation Manual

Manual PVA 4307, PVA 4310, PVA 4316 Video conferencing loudspeaker

iremote ts Frequently asked questions

HD-CM HORIZON DIGITAL CABLE METER

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

ASKING FOR ASSISTANCE

VIVID TV BOX VTB-101 Operation Manual

VNS2200 Amplifier & Controller Installation Guide

Instruction Manual Model Block Downconverter

User s Manual of Signal Level Meter TABLE OF CONTENTS

GENESIS RADIO CALIBRATION PROCEDURES

Quick Use and Hookup Guide

ASP-FIBRS1 User Manual

Linrad On-Screen Controls K1JT

CAT EXT-CAT USER MANUAL

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

Introduction. Introduction

HDMI Extender via Single SC Fiber Support 3D/4K2K Up to 200m in one Single-mode Fiber

Technical Description

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

Single & Dual Input HD Digital DVB-T Modulators

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Coax A/V Agile Demodulator Tuner W/IR Remote Control. User Manual (Model: RFDM2 PDK)

Xsarius Satmeter Pro. Manual

Coda Audio. DNC260 Digital Loudspeaker Processor. User Guide version 0.1

CWHDI-TX2 & RX2 Wireless Multi-Format input Transmitter to HDMI Receiver Box

Instruction Manual Model Downconverter

RF Explorer RackPRO. User Manual. Introduction. Greetings fellow traveler on the RF spectrum.

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Introduction 2. Installation 3. Suggested Configuration 4. Using the Remote 5. Adjustment Mode 6. Technical Specifications 7. Technical Support 8

PIM Master. Maintenance Manual

USER MANUAL. VP-427A HDBaseT to HDMI+Audio Receiver/Scaler MODEL: P/N: Rev 1

REMOTE DISPLAY WIRELESS DECODER MK II

HDS-42AVR HDMI Switcher INSTALLATION MANUAL

Learning to Use The VG91 Universal Video Generator

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

3-in 1- out DVI Switcher

Agilent FieldFox RF Analyzer N9912A

RIGOL. 快速指南 DSA800 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

DataSAT ACU-2 Controller Wiring Configuration - Operation

Instructions when using for the first time 1. Installation (3) 2. Using the Televiewer (4)

User Manual. AVA-EX11-70TX AVA-EX11-70RX 70m HDMI Extender. Version: V1.0.2

Operating Manual WRX-137 Weather Satellite Receiver WRAASE electronic GmbH, Germany

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

Transcription:

Ten Tec RX320 Control Panel Operation Manual (V2.0)

RX320 Control Panel Key functions: 1. Rx Mode key to select LSB, USB, CW, AM 2. Volume Up 3. Volume Down 4. Decreasing Key (for the selected function) 5. Function Mode Down (see Table 1) 6. Frequency/Tuning step/ham band 7. Function Mode Up 8. Increasing Key (for the selected function) 9. Frequency tuning knob with mechanical encoder

Description for the N5/7 key (Function mode ) Mnemonic on Description LCD AGC Automatic Gain Control: key 4 and 8 perform Agc Slow,Medium & Fast AUT Automode: if ON, to any RX mode, is joined the typical selectivity, and tuning step value. Keys 4 and 8 perform ON and OFF Flt Selectivity Filter: Keys 4 and 8 select selectivity: 300 Hz 8 KHz.34 bandwidth with value displayed in Hz (see table) MemR Memory Read: Use Keys 4 (down) and 8 (up) for selecting the memory location from channels 1 to 20 (any location stores Freq. Filter, RX Mode and Tuning Step) MemW Memory Write: Key 8 selects memory location 1 to 20; Key 4 stores the channel received Scan1 Scanning Mode 1: The receiver scans from F1 to F2 frequency. Key 8 stores F1 (F1s on LCD) and F2 (F2s on LCD). Key 4 starts and stops scanning. If field exceede S7 scanning stops. Scan2 Scanning Mode 2: as Sc1 mode but without stop for squelch ScanM Scanning Memory:the receiver scan from channels memory location 1 to 20 ; Key 4 starts and stops scanning. If field exceede S7 scanning stops. BFO - / + 3000 Hz Frequency tuning for CW mode only. Can be used to receive USB/LSB and to adjust the BFO position manually. With BFO = 0 Hz the carrier is centered in the IF filter. With BFO -/+ 3000Hz the carrier is -/ + 3000 Hz out from filter center. The BFO step is 50 Hz. (For LSB adjust BFO about +1500 Hz, for USB about -1500 Hz) LSB and USB RX mode adjust BFO automatically. Ham Band Use Keys 4 (down) and 8 (up) for selecting the Ham bands (with Key 6) T.Lock Key 8 perform On and Off tuning lock on the tuning encoder LineV Key 8 and 4 perform audio control on the Line out of RX320 Selectivity table Filter # Bandwidth Hz Filter # Bandwidth Hz Filter # Bandwidth Hz 0 6000 12 2700 24 900 1 5700 13 2550 25 750 2 5400 14 2400 26 675 3 5100 15 2250 27 600 4 4800 16 2100 28 525 5 4500 17 1950 29 450 6 4200 18 1800 30 375

7 3900 19 1650 31 330 8 3600 20 1500 32 300 9 3300 21 1350 33 8000 10 3000 22 1200 11 2850 23 1050 Scan function The frequency scanning function works in two modes: Scan1: Scans with stop on channel busy Scan2: Scans without stop on channel busy Scanning mode 1 (Scan1 on LCD) To set up scanning proceed as follows: 1. Tune the first frequency (F1) with normal key for tuning 2. With function mode Key (key 5) select Sc1 3. With Key N8 store this frequency; LCD displays F1s. Press the key only once 4. With encoder or with Key 6 (frequency/step) and Keys 4/8 select a new frequency (F2) (F2 must be higher then F1) 5. With function mode key 5 return to Sc1 mode 6. With key N8 store this new frequency; LCD displays F2s. Press the key only once 7. To start scanning press key 4; LCD displays Stop 8. To stop scanning press key 4; LCD displays Str 9. When scanning stops you can change frequency up and down with the encoder

Scanning stops if a carrier overcomes a Squelch level S7. Scanning is performed at the frequency step size selected. Select the appropriate step size for the reception mode selected as follows: 100 Hz step for USB, LSB and CW 3KHz for AM When scanning is running it is possible to change other operating modes: the tuning step, the reception mode and so on. To stop scanning you must always return to Sc1 or Sc2 and press Key 4. Scanning mode 2 (Scan2 on LCD) As for Sc1 mode without stop on channel busy. Start and stop scanning are controlled only with Key 4. Memory scanning (ScanM on LCD) Memory scanning i also possible: the receiver scan from channels memory location 1 to 20 ; Key 4 starts and stops scanning. If squelch threshold is exceeded scanning stops. Description for the Key 6 (Frequency/tuning step toggle) Key 6 toggles frequency or tuning step. The action of Keys 4 and 8 increases and decreases the frequency or tuning step. Description for the N9 Knob The N9 knob performs the frequency tuning with the tuning resolution selected with 6/4/8 key. Tuning step available: 1, 10,50, 100,500, 1000 Hz, 2.5,5, 10, 100,500 KHz, 1MHz Keys 4 and 8 can be used too.( Key 6 togle freq. Tuning or step tuning with key 4 and 8) The knob uses a mechanical encoder. Power-up restore (v 1.2) During tuning, the frequency on use and the Rx mode, are stored in the cnannel memory position M0. When the controller is turned on, the last frequency used is restored. To preserve the EEprom memory durance,(1 Milions writing ) the memory write isn t performed during scanning or during fast tuning. (This feature is added up V1.2 version) Ham Band default restore The last frequency used on each Ham band is stored on EEPROM. To restore Default central Ham band switch the controller ON with the RX Mode Key ( #1 ) hold

Sleep mode The controller is enough quiet so, normally, if you use an external antenna, any RF interference is received. In any case, if necessary, it is possible put the controller on Sleep mode. To do this it is necessary connect to GND Pin 15 of PIC. The sleep mode is displayed with zzzz on the S-meter field. If you remove GND the controller return on normal functionality. Cables & Connections and dimentions Connect the Control Panel unit to the RX320 receiver with the RS-232 with the male DB9 connector supplied Power supply is 8-12v DC. Power request with normal LCD display: 150 ma with LCD light on. The panel dimensions are 150 x 52 x 40 mm

Field strenght meter The field strenght meter uses S scale. In the following table S units, dbm and µv corrispondence. S unit dbm µv note 1-118 0,28 Faint signal, barely perceptible 2-112 0,56 Very weak signals 3-106 1,12 Weak signals 4-100 2,23 Fair signals 5-94 4,46 Fairly good signals 6-88 8,91 Good signals 7-82 17,7 Moderately strogh signals 8-76 35,5 Strong signals 9-70 70,7 Extremely strong signals 9+ -60 223 Extremely strong signals 9++ > -50 >700 Extremely strong signals

RX320 REMOTE CONTROL RX320 mute 1 2 3 Numeric key pad 4 5 6 Clear Freq. on LCD display 7 8 9 0 Store frequency Rx Mode: LSB, USB, CW,AM Function Mode Dw. Function Mode UP Increment mode key (i.e. Freq, sqelch etc) Volume DW Volume UP Freq. or Tunig key toggle Step Tunig DW Decrement mode key Step Tunig UP UNIVERSAL REMOTE CONTROL IR controller for T.T. RX320 The RX320 works also with an IR remote controller. If an infrared sensor is wired to pin 15 of PIC board all the functions are available from the remote controller. The standard 8 keys or the encoder can also be used. Because the operation is much easier with the remote controller it is also possible not to install the keyboard and/or the tuning encoder. The main feature is the possibility to set the frequency directly from the numeric keypad.

RX320 REMOTE CONTROL WITH Credit Card size remote controller

Function Modes/Buttons on Remote Control Mnemonic on Description LCD AGC Med. Or Slow AUT Automatic Gain Control: buttons and perform Agc Fast, Automode: if ON, in any RX mode the typical selectivity, and tuning step value is selected. Buttons and perform ON and OFF FLT Selectivity Filter: Buttons and select selectivity: Range 300-8000 Hz.300 Hz 8 KHz.34 bandwidth with value displayed in Hz MemR MemW Scan1 Scan2 ScanM BFO Ham Band (with Key 6) T.Lock LineV (see table) Memory Read: Use buttons (down) and (up) for selecting the memory location from channels 1 to 20 (each location stores Freq. Filter, RX mode and Tuning Step) Memory Write: Button selects memory location 1 to 20; button stores the channel received Scanning Mode 1: The receiver scans from F1 to F2 frequency. Button stores F1 (F1s on LCD) and F2 (F2s on LCD). Button starts and stops scanning. If field exceede S7 scanning stops. Scanning Mode 2: as Sc1 mode but without stop for squelch Scanning Memory:the receiver scan from channels memory location 1 to 20 ; Button starts and stops scanning. If field exceede S7 scanning stops. + / - 3000 Hz Frequency tuning for CW mode only.. Can be used to receive USB/LSB and to adjust the BFO position manually. With BFO = 0 Hz the carrier is centered in the IF filter. With BFO -/+ 3000Hz the carrier is -/ + 3000 Hz out from filter center. (For LSB adjust BFO about +1500 Hz, for USB about -1500 Hz) The BFO step is 50 Hz. LSB and USB RX mode adjust BFO automatically. Use Keys 4 (down) and 8 (up) for selecting the Ham bands Key 8 perform On and Off tuning lock on the tuning encoder Key 8 and 4 perform audio control on the Line out of RX320 Scan function The frequency scanning function works in two modes: Scan1: Scans with stop on channel busy Scan2: Scans without stop on channel busy Scanning mode 1 (Scan1 on LCD) To set up scanning proceed as follows:

1. Tune the first frequency (F1) with normal key for tuning 2. With function mode (button ) select Sc1 3. With button store this frequency; LCD displays F1s. Press the key only once 4. With button (frequency/step) and buttons / select a new frequency (F2) (F2 must be higher then F1) 5. With function mode button return to Sc1 mode 6. With button store this new frequency; LCD displays F2s. Press the key only once 7. To start scanning press button ; LCD displays Stop 8. To stop scanning press button ; LCD displays Str 9. When scanning stops you can change frequency up and down with Keys Memory scanning (ScanM on LCD) Memory scanning i also possible: the receiver scan from channels memory location 1 to 20 ; Button 4 start and stops scanning. If squelch threshold is exceeded scanning stops. 1.o start scanning press button ; LCD displays Stop 2. stop scanning press button ; LCD displays Str

Universal remote controller can also be used. The PHILIPS RC5 standard should be selected. Be careful to use a controller with the same key dispositions. An utility help to determine if the controller is set to the correct standard is included. If the standard is correct the key code is displayed on the LCD (in the S-meter field) and must verified in the following table. Function key Key code Rx-320 off key 12 Numeric key pad 0 to 9 0 to 9 Clear frequency on LCD display 56 Store frequency key 10 RX mode 30 Function mode DOWN 19 Function mode UP 41 Volume DOWN 17 Volume UP 16 Increment mode key UP 32 Increment mode key DOWN 33 Freq. tuning step toggle key 13 Step tuning DOWN 43 Step tuning UP 18

For the hardware manual see the PICBOARD ed3.pdf