Introduction. All Neutrik Patch Panels are able to handle digital audio signals acc. AES3, 48kHz sampling rate. setting standards

Similar documents
Introduction. Audio Normalling

Introduction. Audio Normalling

Definitions, Abbreviations & Useful Information innovative solutions I superior quality

INSTRUCTION MANUAL NPPA-TT-S PATCH PANEL Easy Patch 96 Bantam (TT) Jacks, Solder lugs

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes

140 innovative solutions I superior quality. are registered trademarks of Neutrik AG.

setting standards registered trademarks of Neutrik AG.

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

DIN EUROCARD CONNECTORS

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

HighBand 25. TrueNet Category 6 Solutions

Digital Wireless Audio Solution

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

134 innovative solutions I superior quality

HARTING Ethernet cabling cables and connectors, 4 wire

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

8D with High Frequency Coaxial Contact

PREMIUM 5e F/UTP PRODUCTS

Non Magnetic Connectors

Data Centre & Communications Room. Category 6. Data Centre & Communications Room. 1 0 / B E TrueNet Structured Cabling

DINTEK LAN Cabling Systems

CATEGORY 6 CABLING SOLUTIONS

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

LCS 2 RJ 45 Cat. 6A HD panels and units

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

High-Performance Patching Systems

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

TNC Connectors. RF Coax Connectors. Product Facts

ASF 1x32 AV 3/1 xxx Blueline ASF 1x32 AV 3/1 xxx Light ** ASF 1x24 AV 3/1 xx Econom

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

CATEGORY 5e CABLING SOLUTIONS

DN1248PLS-FM features transformer-balancing on all outputs, and is fitted with dual redundant power supplies as standard.

Broadband Connectivity System II

EXPlora. Introduction

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

CATEGORY 6A CABLING SOLUTIONS

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

LCS2 Cat. 6 RJ 45 Patch panels and units

BNC 75 RF CONNECTORS. Simple steps to guide you in using this catalogue. Applications. Options. Ordering Codes BNC 75 RF CONNECTORS

SUHNER QMA SUBMINIATURE CONNECTORS

STRUCTURED CABLING SYSTEMS (SCS)

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

ANALOG RADIO MIXER. Flexible. Affordable. Built To Last.

Enterprise Networks. Comms Room and Backbone. in DETAIL

Mounting Set ACCESSORIES

CATEGORY 6A CABLING SOLUTIONS

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

Small Circular Connector. JN1W / JN2W Series

4320 SS-25 Self-Strip Terminating Block

What is the E560? Connecting to the power supply

DS1 Cross-Aisle Panel

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

CAT EXT-CAT USER MANUAL

Series MCX 50 micro miniature connectors

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

Category Index. Category Page# Category Page# Category Page# Audio Audio XLR Connecter

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

MCX Miniature Coaxial Connectors

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

NewScope-7A Operating Manual

ZDC RF Coax Connector Series 50 & 75 Ohm

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

Highlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors

Connecting cables NEBS, for sensors

110LP MOON Series. Phono Preamplifier. Owner s Manual

BNCpro for 3G and Ultra-HD/4K

Unipole and Multipole Connectors

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Small Circular Connector. JN1/JN2 Series. Dust Cap

Cat.6 4 Pair UTP Cable

AudioJoG (TM) Rack 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

Ribbon Cable connector Compliant with MIL Standard

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

MUK REAR PANEL ASSEMBLY ASSEMBLY INSTRUCTIONS

Volition TM RJ45 K5e Jacks

LED Backlight for Technics amplifiers

PL Series. Plastic Push Pull Interconnects

btnet new products Modular and preloaded patch panels btnet

BCS 4R DSX-3 Connectivity System. Models , , and User Manual

MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors. NOT the LATEST REVISION

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

MCX - 75 Ohm Connectors

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

INSTALLATION AND OPERATION MANUAL

Type "N" Connectors. Type "N" Interface Dimensions

SECTION 9 BNC/BNC 75 HDTV/BNC-TRX R141/R142/R266 SIMPLIFICATION IS OUR INNOVATON. Visit for more information

SPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

Technical Specifications

QMA and QN connectors, patented products, become some real standard for the RF Telecommunications industry.

Transcription:

Patch Panels 165

i n n o v a t i v e s o l u t i o n s Content Page Introduction NPPA-eries - 96 Bantam () Jacks... 168 Configuration, Grounding, Wiring... 169 NPP-B-eries - 48 B-Gauge Jacks... 170 Configuration, Grounding, Wiring... 171 1/4" Patch Panel NY eries... 172 Configuration, Grounding... 173 MA 96 and XPM 96 Bantam Patchbays... 174 MAJ 501 Bantam Jack ocket... 175 LF 48 B-Gauge Patchbays... 176 LFJ 501 B-Gauge Jack ocket... 177 echnical Data... 178 Operating Accessories, Labeling software... 178 Ordering Information... 179 Patch Panels are central switching gears between audio equipments. hey are used to switch and route analog and digital audio signals from and to equipments in recording or broadcast studios, OB vans, churches, theatres, stadiums, arenas, etc. Neutrik Patch Panels are available in a varety of jack types, wiring and grounding possibilities. Common versions accommodating Bantam, 1/4 A-gauge and longframe B-gauge jacks on the front rows are available. he mechanical size is designed to fit into 1U 19 standard racks. All Neutrik patch panels offer various normalling possibilities between top and bottom row. All Neutrik Patch Panels are able to handle digital audio signals acc. AE3, 48kHz sampling rate. NEUIK, crystalcon, ethercon, maxcon, minicon, nanocon, neutricon, opticalcon, powercon, Profi, rearwi, silentplug, speakon, DIWA, XIIUM, are registered trademarks of Neutrik AG. 166 setting standards

s u p e r i o r q u a l i t y Audio Normalling Audio Normalling is usually used with audio patch panels and is a wiring pattern in which a circuit path is established from one piece of audio equipment to another without the use of a patch cord. his pattern is then considered to be the normal circuit path that is desired most of the time. If a patch cord is inserted, the normal circuit path is interrupted and rerouted to a different circuit path. Normalled patch panels are most commonly found in vertical jack pairs: the top jack is designated as the source and the bottom jack is the destination. Normalling example: HALF NOMALLED BOOM OW his is the most common configuration, very often called HALF NOMALLED. In this configuration internal normalling contacts connect the top jack contact with the corresponding bottom jack contact. Inserting a plug in the bottom jack will interrupt this internal normalling connection, while inserting a patch cord into the top jack doesn t interrupt the circuit. (Can be used to monitor the normalling circuit) Other versions of normalling are Half Normalled op ow, Full Normalled, Parallel and Isolated. www.neutrik.com 167

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 25 26 27 28 48 Half Normalled Bottom N N Half Normalled op N N Full Normalled N N N N Parallel Isolated Key Grounding Upper ow Common ignal Ground Chassis Ground Bottom ow Common ignal Ground ModuleArrangement opview oldering Pads to connect Individual Grounds to Common Ground NPPA--P N P P A e r i e s obust front design Easy assembly Jack-pair IDC terminals Push terminals ELCO connectors NPPA-eries - 96 Bantam () Jacks NPPA--P Innovative and compact patching system (just 1U high) for 19 rack mounting obustly housed in a black coated steel shell Features 2 x 48 long life gold plated size (bantam) Neutrik NJ3A double contact point jacks Available in all common normalling configurations (default Half Normalled Bottom) Qualified for analog and digital signals according to AE3, 48 khz sampling frequency emove the front panel for quick changes of the NJ3A-** modules for reconfiguration or repair even when "on air" Includes two built in cable bars and two wide channel ID strips PatchLink oftware for printing onto labeling strips is on Neutrik website (available for PC only) Dimensional Drawing 168 setting standards

N P P A e r i e s Design Criteria All NPPA patch panels are fitted with high quality, long life NJ3A gold plated double contact jacks (2x48), featuring best contact integrity. he unit, robustly housed in a black coated steel shell, is finished off with a built in cable bar and two large channel identification strips for perfect management of the system. he NPPA patch panels are an innovative and compact patching system (just 1U high) for 19" rack mounting. Configuration he standard version of the NPPA Panel is delivered bottom row half normalled for each jack pair by default. Further patch versions are available with fully loaded jack-pairs as: Full Normalled Half Normalled Isolated Parallel For individual normalling single pre-configured jack-pairs are offered. NPPA--IDC is equipped with jumper blocks for individual switching configurations of each jack channel. Note: ake care when handling digital signals. Do not use parallel configuration and avoid other parallel paths when using half normalled configurations. Parallel paths may lead to mismatching. Half Normalled Bottom Half Normalled op Full Normalled Parallel Isolated Grounding he flexible grounding system provides the following versions: Individual: Each channel is individually grounded by its corresponding cable shield (default configuration). Group: elected channel grounds are connected via the ground bus on the PCB using solder bridges and track cuts to form a group that is connected to one common cable shield. Central: All channel grounds (individual top and bottom row) are connected via the ground bus on the PCB using solder bridges and wired with only one cable shield. Chassis-Common: he same as central grounding but with the addition of the common ground bus (top and / or bottom rows) connected to the patch panel chassis by means of jumpers Wiring erminations patch panels offer different choices of wiring: pring loaded push terminals 56 pin Elco/Edac male connectors 90 pin Elco/Edac connectors 50 pin D-UB connectors 25 pin D-UB connectors IDC-Krone terminals older lugs he spring loaded terminal blocks enable fast and easy wiring. No soldering and screwing necessary. imply insert the stripped wire after pressing down the white key. erminals accommodate stranded wires up to AWG 20 (0.5 mm 2 ) and solid wires up to AWG 18 (0.75 mm 2 ). Push terminals are gas tight connections. For Pin assignment of ELCO / EDAC and D-UB connectors please see drawings on www.neutrik.com www.neutrik.com 169

N P P - B e r i e s Individual colour coding Galvanized metal housing NPP-B-eries - 48 B-Gauge Jacks NPP-B-HN NPP-B + NPP-LB* Features 2 x 24 Neutrik NJ6B-V long frame 1/4 jacks according to BPO316/MIL-P-642/2 Very robust and compact galvanized metal housing Compact, cost effective system qualified for both analog and digital signals acc. AE3, 48 khz sampling frequency High quality long life gold plated Neutrik jacks Easily programmable for any of 6 configurations with 4 grounding choices ear terminations include solderless terminal blocks or solder lugs (solder for non-programmable half-normalled versions only). Center marking strip is removable; ee Neutrik website to download PatchLink labeling software for PCs Color coded tabs, dust cover and rear extension strain relief bars are optional accessories Dimensional Drawing NPP- (Accessories) NPP- 170 setting standards

N P P - B e r i e s Design Criteria he NPP-B patch panels are equipped with gold plated, high quality long life NJ6B-V Jacks for BPO/MIL style plugs. he panels are easily programmable for six switching configurations and offer a flexible grounding system. he NPP-B patch panels are very robust and compactly designed for 19" rack mount (19" x 1U) with galvanized metal housing and a built-in cable bar on the rear for securing wires. here is a rear extension bar (NPP-) available as an option. On the front side there is an attractive additional lettering area for each channel pair with a marking strip and individual snap-on colour coding plates. Configuration Due to the jumper blocks capability provided, the switching configurations available per jack channel are: Half Normalled Bottom ow Full Normalled Parallel Isolated he B Panel is delivered in a full normalled configuration for each jack channel. A non-configurable half normalled ("-HN") bottom row version with solder lugs is also available. NOE: ake care when handling digital signals. Do not use Parallel configuration and avoid other parallel paths with Half / Double Normalled configurations. Parallel paths may lead to mismatching. Half Normalled Bottom Half Normalled op Full Normalled Parallel Isolated Double Normalled Grounding he flexible grounding system allows four possibilities to fit your needs: Individual: Each channel ground is separately connected with the corresponding cable shield (default configuration). Group: ome channel grounds are PCB connected by making soldering joints on the PCB and by cutting tracks respectively to form a group that is connected to one common cable shield. Central: All channel grounds are PCB connected by making soldering joints and wired with only one cable shield. Chassis-Common: ame as central grounding with additional connection of the common ground to the Patch Panel chassis by means of a jumper. Wiring erminations B patch panels are available with: pring loaded push terminals (NPP-B) older lugs (NPP-B-HN) he spring loaded terminal blocks are fast and easy to connect and disconnect the wires. No soldering and screwing necessary. imply insert the stripped wire after pressing down the white key. Accommodates stranded wires up to AWG 20 (0.5 mm 2 ) and solid wires up to AWG 18 (0.75 mm 2 ). www.neutrik.com 171

N Y e r i e s uggedized metal housing Imprinted grounding instruction Module NY-PC1 1/4" Patch Panel NY-PP-L1 Individual grounding available for each channel separately uggedized metal housing Improved contact design minimises wear on mated plugs Economic and versatile designed 1/4" modular patch panel with 2 rows of jack sockets 48 balanced channels with fully PCB wired jack (24 vertical PC boards), 24 front pairs and corresponding 24 rear pairs Jack PC card contains 4 balanced 1/4" jacks with non-tarnishing contacts, is held securely in place without the use of nuts - no little pieces to drop, break or lose Easy to change configuration by just flipping individual PC board Normalling jack is coloured grey for easy identification 4 designation strips included for front and rear panel Dimensional Drawing 172 setting standards

N Y e r i e s Design Criteria he NY-PP-L1 is a economical and remarkable sleek designed 1/4 modular patch panel for 19 rack mount (19 x 1U) with a reinforced metal housing. Each of it s 48 PCB wired balanced channels (24 front pairs and corresponding 24 rear pairs) can either be grounded separately or in groups of inividually chooseable channel numbers (detailed information see below). he PCBs are held securely in place by being clamped between the front and the rear panel, this grants an easy reconfiguration of the patch panel without the danger of loosing any small parts (e.g. nuts). he grey jack serves as an easy and distinguishable normalling identification. Configuration tandard configuration, when delivered, is Half Normalled bottom row. he configuration can easily be changed by just flipping the individual PCB. Inserting a plug into the grey jack will always isolate the top against the bottom row. Alternative solution for send / return applications by use of NY-PC1 module (see accessories below). he following configurations are available: tandard urned plit Print front rear front rear front rear front rear A A A A A A A B B B Plug B Front jack A for "listen in" Grey B jack for signal insertion Allows: 1 output to feed 2 inputs Upper (A) and lower (B) channel separated B B B B Plug A A front Mono - end B front Mono - eturn (ed Jack) NY-PC1 With witching Contacts ear end - eturn (tereo Jack) olution for insert jack of mixing consoles plit print by-passes the use of a specially wired Y-cable. Grounding he flexible grounding system, applicable for each channel separately by simply attaching the loose supplied grounding clips to the grounding pad of the corresponding channel, offers the following alternatives: Individual (without grounding clip): Each channel ground (sleeve contact) is connected to the dedicated ground contact of the incoming 1/4 plug only. his is the standard configuration for delivery. Chassis common : he relevant channel grounds (sleeve contacts; top and bottom row) is connected to the ground flat tab via grounding clip and chassis. Chassis top : he dedicated top channel ground (sleeve contact) is connected to the ground flat tab via grounding clip and chassis. Chassis bottom : he dedicated bottom channel ground (sleeve contact) is connected to the ground flat tab via grounding clip and chassis. ear view detail: Ground flat tab to be used with FAON receptacle or to solder the wire. grounding clip (slide onto the print) www.neutrik.com 173

B a n t a m P a t c h P a n e l s tandard 4.4mm bantam jack Long frame jack socket MA 96 and XPM 96 Bantam Patchbays obust designed patchbay to accept standard 4.4 mm Bantam jack connectors (acc. MIL-D-642/13) Fitted with 96 ean die-cast jack sockets Constructed from rigid aluminium extrusion which includes 2 integral slots for designation strips 96 channels grouped in two row 12 x 8 stereo jacks XPM96 features traditional 2 row, 4 x 24 stereo jacks Available in 4 colours: black, silver, red or blue uitable for audio, broadcast, data and industrial applications XPM96 Dimensional Drawing 174 setting standards

B a n t a m P a t c h P a n e l s Die-cast frame inned tags MAJ 501 Bantam Jack ocket 5-point Bantam jack socket (ip, ing, leeve, ip Normal, ing Normal) igid nickel plated die-cast frame, featuring considerable frame strength eliminating physical distortion when plug is inserted Nickel-silver spring contacts, palladium plated switch contacts inned tags for easy soldering ermination End Elevations Plan Elevations Circuit Detail www.neutrik.com 175

L o n g f r a m e B - G a u g e P a t c h P a n e l s B-Gauge patchbay 48 way longframe LF 48 B-Gauge Patchbays 48 way Longframe B-Gauge patchbay Accepts both European BPO 316 and U MIL-P-642/2 style phono plugs 2 rows of 24 LF501 jack connectors Jack designed from rigid nickel-plated die-cast aluminium with nickel-silver spring contacts Available in 4 colours: black, silver, red or blue eliable support for connecting looms by steel lacing bar Dimensional Drawing 176 setting standards

L o n g f r a m e B - G a u g e P a t c h P a n e l s older lugs LFJ 501 B-Gauge Jack ocket 5-point B-Gauge jack socket Nickel-silver spring contacts Palladium plated switch contacts Durable die-cast body with bright nickel plated nose ermination solder lugs LFJ 501 Plan Elevations Circuit Detail www.neutrik.com 177

e c h n i c a l D a t a pecifications NPPA NPP-B NY MA 96 and LF 48 eries eries eries XPM 96 eries Electrical Contact resistance: < 20 mω < 10 mω < 10 mω < 24 mω < 20 mω witch contact resistance: < 25 mω < 15 mω < 10 mω < 26 mω < 15 mω Insulation resistance: > 1 GΩ @ 500 V dc Dielectric strength: > 500 V ac > 1`000 V dc - - Frequency range: DC to > 50 MHz Channel separation: > 100 db @ 10 khz 600 Ω terminated > 40 db @ 6 MHz 110 Ω terminated AE / EBU ignals (digital) suitable: Handles Phantom Power: Mechanical Life time: > 20`000 cycles - - - > 10`000 cycles - - - - > 5`000 cycles - - - Insertion force: < 25 N - - - < 20 N - - - - < 10 N - - - Withdrawal force: > 10 N > 8 N - - - Dimensions: 482 x 44 mm (19" x 1U) Depth: 178 mm (7") 140 mm (5.5") 64 mm (2.52") 110 mm (4.33") 115 mm (4.53") Dimension Patch Box: 168 x 77 x 77 mm (6.0 x 3 x 3") emperature range: - 30 C to + 80 C Mating plug: 4.4 mm (0.173") B-Gauge 1/4" plug A-Gauge 1/4" plug 4.4 mm (0.173") Longframe Bantam plug acc. EIA -453 Bantam plug B-Gauge plug according MIL-P-642/13 BPO316/MIL-P-642/2 EC60603-11 MIL-P-642/13 BPO316/MIL-P-642/2 Grounding wiring flat tab for 3/16" - - - - FAON (4.8 x 0.8 mm) Material Housing: teel teel teel anodised Al anodised Al Front panel: anodised Al Pocan B 3225 teel anodised Al anodised Al Lacing bar: Brass teel N / A coated steel coated steel Jack housing: PA 66 blend PA 6.6 30% G AB diecast alloy diecast Al Jack contacts: Cun6 Cun6 Cun6 Ni-ilver Ni-ilver ribor plated Au plated tin plated (CuNi18Zn20) (CuNi18Zn20) witch contacts: Au plated Au plated Bronze, tin plated Palladium plated Palladium plated Grounding clip: - - Cun6, ncu plated - - Operating Accessories Labeling software Patchlabel is a program to Label Patch Panel designation strips. Free Download of Patch Label Program (ZIP 347 KB) on the Web "www.neutrik.com" section "Patch Panels". 178 setting standards

O r d e r i n g I n f o r m a t i o n Part Number Description NPPA eries Configuration* Wiring Grounding NPPA--P** 2 x 48 jacks half normalled bottom 288 push terminals individual NPPA--P-FN** 2 x 48 jacks full normalled 288 push terminals individual NPPA--P-HN** 2 x 48 jacks half normalled top row 288 push terminals individual NPPA--P-I** 2 x 48 jacks isolated 288 push terminals individual NPPA--P-P** 2 x 48 jacks parallel 288 push terminals individual NPPA--** 2 x 48 jacks half normalled bottom 288 solder terminals individual NPPA---FN** 2 x 48 jacks full normalled 288 solder terminals individual NPPA---HN** 2 x 48 jacks half normalled top row 288 solder terminals individual NPPA---I** 2 x 48 jacks isolated 288 solder terminals individual NPPA---P** 2 x 48 jacks parallel 288 solder terminals individual NPPA--P-PH 2 x 48 jacks half normalled bottom 288 Phoenix push terminals individual NPPA--D50 2 x 48 jacks half normalled bottom 4 x 50 pole D-UB groups of 12 channels NPPA--D25 2 x 48 jacks half normalled bottom 12 x 25 pole D-UB groups of 12 channels NPPA--E56 2 x 48 jacks half normalled bottom 6 x 56 pole ELCO male connectors individual NPPA-48-E56 2 x 24 jacks half normalled bottom 3 x 56 pole ELCO male connectors individual NPPA--E90 2 x 48 jacks half normalled bottom 4 x 90 pole ELCO male connectors individual NPPA--IDC 2 x 48 jacks programmable by jumpers 288 IDC terminals (KONE-ype) individual * : fully loaded jack pairs only, to built patch panels with mixed configuration use pre-config jackpairs **: in case of need added normalling bars can be used to reconfigure up to 4 jackpairs Pre-configured Jack-Pairs NJ3A-4-HNB blocks of 2 channels half normalled bottom row cover ident color: clear NJ3A-4-HN blocks of 2 channels half normalled top row cover ident color: yellow NJ3A-4-FN blocks of 2 channels full normalled cover ident color: green NJ3A-4-P blocks of 2 channels parallel cover ident color: red NJ3A-4-I blocks of 2 channels isolated cover ident color: orange Accessories NPPA- NK* train elief bar Patch cords with NP3-1 plugs. Available in black, blue, green, red and yellow. Lenght: 30, 40, 60, 90, 120 cm NPP-B eries Configuration Wiring NPP-B 2 x 24 B (BP0316/MIL-P-642/2) jacks programmable for all commonly used configurations push terminals NPP-B-HN 2 x 24 B (BP0316/MIL-P-642/2) jacks half Normalled Bottom ow solder tags Accessories NPP-LB-** NPP-C NPP- NKB* Channel identification and status plates, pack of 100 per color, 9 different colors Metal dust cover A second rear extention bar for fix the very large cables. Patch cord with NP3B plugs. Available in black and red. Length: 30, 40, 60, 90 cm **: 0 - Black, 1- Brown, 2 - ed, 3 - Orange, 4 - Yellow, 5 - Green, 6 - Blue, 7 - Violet, 8 - Grey, 9 - White; Must be ordered in multiples of 100. NY PPL NY-PP-L1 NY-PC1 1/4" Patch Panel, 2 x 24 channels, configuration half normalled, isolated, split end / eturn module (plit Print) www.neutrik.com 179

O r d e r i n g I n f o r m a t i o n Part Number Description MA96 and XPM-96 MA96-1A 96 way, ed front panel grouped 12 x 8 MA96-1D 96 way, Blue front panel grouped 12 x 8 MA96-1O 96 way, Black front panel grouped 12 x 8 MA96-1 96 way, ilver front panel grouped 12 x 8 XPM-96 96 way, ilver front panel grouped 4 x 24 XPM-96O 96 way, Black front panel grouped 4 x 24 Bantam Jack ocket MAJ-501 tandard older ag LF48 Longframe B-Gauge Patchbays LF48-1A LF48-1D LF48-1O LF48-1 LFJ-501 48 way, ed front panel 48 way, Blue front panel 48 way, Black front panel 48 way, ilver front panel Longframe B-Gauge jack socket, standard solder tag 180 setting standards