- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Similar documents
LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i / DMP 333i LMP 331 i

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Pressure transmitter For applications in hazardous areas Model IS-3

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor BI1.5-EG08K-Y1

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Micro-Machined Silicon Transducers

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Quality products from a single source

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Selection matrix for electronic pressure switches

PROPORTIONAL VALVES Sentronic plus

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Single Point Flow Monitor SW118 SW119

PMG. Vibration Energy Harvesters

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Level Measurement silometer FMC 420, FMC 423

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Mechanical flow switch for On/Off control

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

RSCC. Load cells. Special features. Data sheet

Process Transmitter RMA 422

Pressure transmitter COMPACT IO-Link,

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Linear encoders without bearings incremental System for linear motion feedback

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Process transmitter RMA422

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Photoelectrics Through-beam Type PA18C.T..., DC

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

APPLICATIONS. Automatic warehouse. Trasportation lines

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

The full range of performance

Signet 2250 Hydrostatic Level Sensor

Quality products from a single source

Panel-mounting thermostats, type series EM

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

Eddy Current Probe System

Panel-mounting Thermostats EM Series

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

SERIES 400 SERIES 620

Gear Pump Units For single-line centralized lubrication systems

Capacitance Level Measurement Electronic insert FEC 12

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Linear flow control with actuator IFC

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

APPLICATIONS. Automatic warehouse. Trasportation lines

Level Measurement Point level measurement - RF Capacitance switches

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Panel-Mounted Thermostat

Flow Switch. Flow Switch

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Photoelectric Sensors E3F2

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

IONIVAC Transmitter ITR 90

Linear flow controls VFC Linear flow controls with actuator IFC

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

>Inductive. REFERENCE guide. Proximity

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Transcription:

DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0. % FSO IEC 60770) nominal pressure ranges from 0... 40 mbar up to 0... 40 bar The DMP is a pressure transmitter for universal use in all branches of industry. Permissible media are compressed air, non-aggressive gases, steam, water, heating and diesel oil as well as all with stainless steel.457 resp..445 compatible media. A piezoresistive stainless steel sensor, which features small thermal effect and excellent linearity generate the basis of the DMP. So it is possible to meet accuracy demands up to 0, % FSO (IEC 60770). A variety of standard output signals as well as mechanical and electrical connections make the DMP covering a wide field of applications. Additional it is possible to use the DMP in explosive area (zone 0 / 0). Typical areas of use are: pneumatics / hydraulics process control and chemical industry environmental engineering measurement technology Characteristics small thermal effect excellent linearity option Ex-version (only for 4 0 ma / -wire) TÜV 0 ATEX 006 X option: flush pressure port specific versions: - special pressure ranges - variety of electrical and mechanical connections - other versions on request DMP BD SENSORS GmbH BD-Sensors-Strasse Telefon +4 (0) 5 / 8-0 www.bdsensors.de D - 5 Thierstein Telefax +4 (0) 5 / 8 - info@bdsensors.de

DMP Input pressure range Nominal pressure gauge [bar] -...0 0.04 0.06 0.0 0.6 0.5 0.4 0.6.0.6.5 4.0 6.0 0 6 5 40 Nominal pressure abs. [bar] - - - 0.0 0.6 0.5 0.4 0.6.0.6.5 4.0 6.0 0 6 5 40 Permissible overpressure [bar] 0. 0. 0.5 0.5 6 6 0 0 0 60 00 00 Output signal / Supply Standard -wire: 4... 0 ma / V S =... 6 V DC Ex-protection: V S = 4... 8 V DC Optional -wire: 0... 0 ma / V S = 4... 6 V DC 0... 0 V / V S = 4... 6 V DC Performance Accuracy Permissible load standard: nominal pressure > 0.4 bar nominal pressure 0.4 bar option : nominal pressure > 0.4 bar option : nominal pressure bar option : nominal pressure 0.6 bar current -wire: R max = [(V S V S min ) / 0.0] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω IEC 60770 ± 0.5 % FSO ± 0.50 % FSO ± 0.5 % FSO ± 0.0 % FSO ± 0.0 % FSO Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability Response time ± 0. % FSO / year < 5 msec BFSL ± 0.75 % FSO ± 0.50 % FSO ± 0.5 % FSO ± 0.00 % FSO ± 0.050 % FSO Thermal errors (Offset and Span - standard) Nominal pressure P N [bar] -... 0 0. 0.5 0.4.0 >.0 Tolerance band [% FSO] ± 0.75 ±.0 ±.5 ±.0 ±.0 ± 0.75 TC, average [% FSO / 0 K] ± 0.07 ± 0. ± 0. ± 0.4 ± 0. ± 0.07 in compensated range [ C] 0... 70 0... 50 0... 70 Thermal errors (Offset and Span - optional for -0... 50 C) Nominal pressure P N [bar] -... 0 0.5 0.4.0 >.0 Tolerance band [% FSO] ±.5 ±.0 ±.5 ±.0 ± 0.75 TC, average [% FSO / 0 K] ± 0. ± 0. ± 0. ± 0. ± 0.07 in compensated range [ C] -0... 50 Electrical protection Short-circuit protection Reverse polarity protection permanent no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Option Ex-protection only with 4... 0 ma / -wire DX-DMP zone 0 : II G EEx ia IIC T4 zone 0: II D T 85 C safety technical maximum values: V i = 8 V, I i = ma, P i = 660 mw, C i nf, L 0 µh i Permissible temperatures Medium -5... 5 C Electronics / environment -5... 85 C Ex-protection: application in zone 0: -0... 60 C application in zone or higher: -5... 70 C Storage -40... 00 C accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) with optional accuracy 0. % FSO the response time is 00 msec approved for atmospheric pressure from 0.8 bar up to. bar pressure measurement

DMP Mechanical stability Vibration 0 g RMS (0... 000 Hz) Shock 00 g / msec Mechanical connection Standard Optional G/ EN 87 G/4 DIN 85 G/4 EN 87 / NPT /4 NPT M0 x.5 M0 x M x M x.5 G/ DIN 85 G/ flush (DIN 85) 4 G/ open port M0 x.5 Total length of devices with Ex-protection increases by 0 mm! Total length of devices with accuracy 0. % FSO IEC 60770 increases by 7 mm! (standard and Ex-protection) Electrical connection Standard Optional DIN 4650 (IP 65) Binder Series 7 (IP 67) Mx 4-pin (IP 67) Cable gland (IP 67) 5, 6 M6x.5 (for cable- 4 up to mm) Cable outlet (IP 68) 5 Buccaneer (IP 68) 7 Field housing (IP 67) 4 impossible for nominal pressure PN < 0. bar and for vacuum ranges 5 different cable types and lengths available 6 standard: m PVC cable without ventilation tube, optionally cable with ventilation tube 7 for gauge pressure cable with ventilation tube required www.bdsensors.de

DMP Materials Pressure port stainless steel.457 (6Ti) Housing standard: stainless steel.40 (04) field housing: stainless steel.405 (0), cable gland: brass, nickel plated Seals (media wetted) Diaphragm Media wetted parts standard: FKM optional: EPDM; welded version 8 ; others on request stainless steel.445 (6L) pressure port, seals, diaphragm Miscellaneous Cable capacitance cable without air tube: signal line/shield: 60 pf/m signal line/signal line: 0 pf/m cable with air tube: signal line/shield: 50 pf/m signal line/signal line: 00 pf/m Cable inductance cable without air tube: signal line/shield: 0.65 µh/m signal line/signal line: 0.65 µh/m cable with air tube: signal line/shield:.0 µh/m signal line/signal line:.0 µh/m Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight Installation position any 0 Operational life approx. 40 g > 00 x 0 6 cycles Pin configuration Electrical connection DIN 4650 Binder 7 (5-pin) -wire-system Supply + Supply 4 -wire-system Supply + Supply Signal + Ground Wiring diagrams -wire-system (current) -wire-system (current) Mx (4-pin) Buccaneer (4-pin) Ground ground pin 5 4 4 4 ground pin 5 4 4 -wire-system (voltage) 8 welded version only with pressure ports according to EN 87; welded version not available with pressure ranges 0.6 bar if the electrical connection is a mounted cable by factory cable colours (DIN 4700) white brown yellow / green (shield) white brown green yellow / green (shield) This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. 0 Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviations in the zero point for pressure ranges P N bar. DMP_E_0006 Telefon +4 (0) 5 / 8-0 Telefax +4 (0) 5 / 8 - www.bdsensors.de info@bdsensors.de

Fax: +4 (0) 5 / 8 - Ordering code DMP DMP - - - - - - - Pressure gauge 0 absolute Input [bar] 0,04 0 4 0 0 0,06 0 6 0 0 0,0 0 0 0 0,6 6 0 0 0,5 5 0 0 0,40 4 0 0 0 0,60 6 0 0 0,0 0 0,6 6 0,5 5 0 4,0 4 0 0 6,0 6 0 0 0 0 0 6 6 0 5 5 0 40 4 0 0-0 X 0 Output 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire E Accuracy standard for P N > 0,4 bar 0,5 % standard for P N 0,4 bar 0,5 % 5 option for P N > 0,4 bar 0,5 % option for P N bar 0, % B option for P N 0,6 bar 0, % Electrical connection Male and female plug DIN 4650 Binder series 7 (5-pin) 0 0 0 0 Cable gland incl. Cable, 4 0 0 Cable outlet T R 0 Male plug Buccaneer IP68 4 Mx (4-pin) Field housing stainless steel 5 0 0 M 0 0 8 0 0 Mechanical connection G/" DIN 85 G/" EN 87 G/4" DIN 85 G/4" EN 87 G/" DIN 85 with 5 flush sensor G/" DIN 85 open pressure port /" NPT /4" NPT Seals FKM EPDM without (welded version) Special version standard special compensation -0... 50 C absolute pressure possible from 0, bar different cable types and lengths deliverable standard: m PVC cable without ventilation tube, optionally cable with ventilation tube 4 for gauge pressure cable with ventilation tube required 0 0 0 0 0 0 4 0 0 F 0 0 H 0 0 N 0 0 N 4 0 6 5 Mechanical connection G/" DIN 85 flush impossible for nominal pressure PN < 0. bar and for vacuum ranges 6 welded version only with pressure ports according to EN 87; not possible with pressure ranges 0.6 bar 0 0 0 0 0 6 BD SENSORS GmbH BD-Sensors-Straße Telefon +4 (0) 5 / 8-0 www.bdsensors.de D - 5 Thierstein Telefax +4 (0) 5 / 8 - info@bdsensors.de 0006 This ordering code contains product specification; properties are not guaranteed. Subject to change without notice.