PRE-INSTALLATION ELECTRICAL POWER GUIDE

Similar documents
Benchmark and Benchmark Platinum Electrical Power Guide

Figure 1: Device components


DIGITAL TIME CLOCK. used with the Meal-Time Control Panel. AGRI-TIME TM Control Instruction Page 1

Ultra Quiet Series Electric Air Handler

Operating Instructions Dimmer for V Incandescent Lamps

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

KRF EMC Filters Installation, Operation and Maintenance Manual

TRF STEP-DOWN TRANSFORMER USER MANUAL

YLAA YLAA0175 AIR-COOLED SCROLL CHILLERS STYLE A, B or C (60 Hz) TON KW

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Installation Manual Original Instructions - IW4001

Model Number Structure

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

Identification - electrical services

Trusted 40 Channel 120 Vac Digital Input FTA

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Trusted 40 Channel 120 Vac Digital Input FTA

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

Table of Contents 5.0 WARRANTY. 1.0 Introduction Unpacking 1.2 Repacking and Storage

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Master Time Clock MTC Users Manual

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

/ PAT01 USER MANUAL

EG4015. Digital Generator Governor Controller User Manual

MATE3 Owner s Manual Addendum

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Trusted 40 Channel Analogue Input FTA

Caution. Hanging the Screen:

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

TAC1 Telephone Entry System

AGS Low profile capacitive air gap measuring sensor for rotating machines

INSTRUCTION BOOK FOR. Lectern

Digital Economy Seven Programmer

Environmental Technology, Inc.

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

Backlight Replacement

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Sprite TL Quick Start Guide

Model /29S RF Splitter

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

STEVAL-IHM025V1. 1 kw 3-phase motor control demonstration board featuring the IGBT SLLIMM STGIPL14K60. Features. Description

STEVAL-IHM043V1. 6-step BLDC sensorless driver board based on the STM32F051 and L6234. Features. Description

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

7 Day Digital Programmer 3 Channel Surface Mount

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

Split System Air Conditioner

Prodigy Eclipse ECC and EH222 Service Parts EH222 Cabinet - C Series

INSTALLATION INSTRUCTIONS FOR

16 Amp Electronic 24 Hour/7 Day Time Controller

LBS-1 (Lowrance Broadband Sounder)

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

DisplayPort to VGA Converter

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

3M Sensored Termination (15 kv) QX-T15I-vi1-E

POINTS POSITION INDICATOR PPI4

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

STEVAL-IHM021V W, 3-phase inverter based on the L6390 and UltraFASTmesh MOSFET for speed FOC of 3-phase PMSM motor drives. Features.

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Portable Automatic Satellite System. Model VQ2000

STEVAL-IHM008V1. BLDC & AC motor control Power board SEMITOP 2 1kW. Features. Applications

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:

Colour Explosion Proof Video Camera USER MANUAL VID-C

WIRING INSTRUCTIONS CROP-LINK Drip Installation

DisplayPort Extender over 2 LC Fibers

Installation Manual SaVi Note Underwater LED Light

SPECIAL SPECIFICATION 2344 TMC Support Equipment

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

Power Injector 1520 Series

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

MaxLite LED Wall Packs (Cutoff & Standard)

Aspect 2 Circuit Digital Scene Control

FD932DVD-LP. Installation and Operation Manual Low-Profile DVD/CD/MP3 Player MAN FD932DVD-LP. TECHNICAL SUPPORT , or

Warner Photoscanner MCS-500 Series LED Photoelectric Control

ELECTRICAL SERVICE ORDER FORM

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

Sevenlogic Comfort Timer Switch

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Electronic 1-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

Portable In-Motion Automatic Satellite System. Model VQ3000

DisplayPort Extender over 2 LC Fibers

VS-201H VS-401H VS-801H

NEA WIRING CENTRE NEA HT 230V /24 V

Single Station Waterproof Timer

LED Driver Compact dimming

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Operating Manual RISH OPTIMA VAF

OWNER'S MANUAL MYCRO SUB

Chore-Tronics 2 Breeder Edition Override Box

SQM40/41 Actuators for air and gas dampers

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Transcription:

Benchmark Series Boilers GF-2060 Pre-Installation PRE-INSTALLATION ELECTRICAL POWER GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers This document applies to the Following Benchmark and Benchmark Platinum models: BENCHMARK & Benchmark Platinum Gas-Fired Boilers BMK 750 BMK 1000 BMK 1500 BMK 2000 BMK 2500 BMK 3000 BMK 5000 BMK 6000 Last Update: 12/01/2016 DISCLAIMER The information contained in this manual is subject to change without notice from AERCO International, Inc. AERCO makes no warranty of any kind with respect to this material, including, but not limited to, implied warranties of merchantability and fitness for a particular application. AERCO International is not liable for errors appearing in this manual, nor for incidental or consequential damages occurring in connection with the furnishing, performance, or use of these materials. 09/30/2016 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 1 of 8

GF-2060 Benchmark Series Boilers Table of Contents 1. GENERAL... 3 2. Boiler Electrical Requirements... 3 3. Provisions for Service... 5 4. Boiler Wiring... 5 5. Multiple Unit Wiring... 7 Technical Support: (Mon Fri, 8am-5pm EST) 1-800-526-0288 www.aerco.com Page 2 of 8 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 12/01/2016

1. General Benchmark Series Boilers GF-2060 Benchmark (BMK) Gas Fired Boilers are fully factory wired packaged units which require simple external power wiring as part of the installation (Diagram 1). This technical guide is intended to help designers provide electrical power wiring (line voltage) to Benchmark units. Control wiring details are provided in other publications, depending upon unit application. This document is intended only as a guide and therefore cannot include all possible alternatives, or unit applications. In order to comply with all codes and authorities having jurisdiction, designers and installers must plan the electrical wiring carefully and execute the installation completely. Emergency shutoffs, fusible fire switches, break glass stations, and other electrical requirements should be considered and installed whenever necessary. 2. Boiler Electrical Requirements Benchmark boilers are available with the following power options: BMK Model Voltage Phase Amperage BMK 750-2000 120V 1 / 60 Hz 20 BMK 2500-3000 208-230V 3 / 60 Hz 20 460V 3 / 60 Hz 15 208V 3 / 60 Hz 30 BMK 6000 460V 3 / 60 Hz 20 575V 3 / 60 Hz 20 Voltages lower than those specified in the table above will result in increased wear and premature failure of the blower motor. Wire size and type should be made per the National Electrical Code based on length and load. For all Benchmark models, the power box for field wiring connections is located in the upper right corner behind the unit front panel (see Diagram 2). All copper wire must be connected to the power box. Control Panel Service Disconnect Switch Diagram 1: Service Switch Typical Location 12/01/2016 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 3 of 8

GF-2060 Benchmark Series Boilers TRANSFORMER FUSE BLOCKS TERMINAL BLOCKS 12V POWER SUPPLY POWER BREAKER NOTE: BMK 1500/2000 units have 1 Power Breakers (not shown). Diagram 2: Power Box Connections for BMK 1500/2000/2500/3000/6000 FUSE BLOCKS POWER BREAKER 120V OUTPUT, 6 AMP MAXIMUM 12V POWER SUPPLY TERMINAL BLOCKS TRANSFORMER Diagram 3: Power Box Connections for BMK 750/1000 Page 4 of 8 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 12/01/2016

3. Provisions for Service Benchmark Series Boilers GF-2060 Designers must provide emergency shutoffs and other devices to satisfy electrical codes. It is also recommended to provide an electrical shutoff disconnect switch of suitable load carrying characteristics on or near each BMK boiler. No electrical boxes or field components should be mounted to the surface of the boiler or where they would interfere with the removal of the side or top panels for maintenance. The service disconnect switch should be mounted near the unit, as illustrated in Diagram 1. Wiring conduit, EMT, or other wiring paths should not be secured to the unit, but supported externally. Electricians should be instructed as to where the wiring conduit should be located, such as away from the relief valve discharge, drains, etc. All electrical conduit and hardware should be installed so that it does not interfere with the removal of any covers, inhibit service or maintenance, or prevent access between the unit and walls or another unit. 4. Boiler Wiring A dedicated protected circuit should be provided from the power source to the boiler. No other electrical devices should be permanently wired on the same circuit. The protected circuit and circuit breaker switch must be sized for the amperage values below. An emergency switch (electrical shutoff) must be in series with the power to the unit. For applicable wiring connections, refer to the following Diagrams: Diagram 4 - BMK 750/1000/1500/2000: 120V / 1 /60 Hz @ 20 amps Diagram 5 - BMK 2500/3000: 208-230V / 3 / 60 Hz @ 20 amps Diagram 6 - BMK 2500/3000: 460V / 3 / 60 Hz @ 15 amps Diagram 7 - BMK 6000: 208V / 3 / 60 Hz @ 30 amps Diagram 8 - BMK 6000: 460V / 3 / 60 Hz @ 20 amps & 575V / 3 / 60 Hz @ 20 amps 1 POLE 20 AMP CIRCUIT BREAKER DISCONNECT SWITCH 1 POLE 20 AMP 3 WIRE 120V/1 /60 Hz Diagram 4 - BMK 750/1000/1500/2000: 120V / 1 / 60 Hz Wiring Schematic 3 Wire 12/01/2016 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 5 of 8

GF-2060 Benchmark Series Boilers Diagram 5 - BMK 2500/3000: 208-230V / 3 / 60 Hz Wiring Schematic- 5 Wire Diagram 6 - BMK 2500/3000: 460V / 3 / 60 Hz Wiring Schematic- 4 Wire Page 6 of 8 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 12/01/2016

Benchmark Series Boilers GF-2060 4 WIRE 208V/3 /60 Hz Diagram 7: BMK 5000/6000: 208V / 3 / 60 Hz Wiring Schematic- 4 Wire 3 POLE 20 AMP CIRCUIT BREAKER DISCONNECT SWITCH 3 POLE 20 AMP 460V/3 /60Hv OR 575V/3 /60 Hz Diagram 8: BMK 5000/6000: 460V / 3 / 60 & 575V / 3 / 60 Hz Wiring Schematic- 4 Wire 5. Multiple Unit Wiring Whenever multiple units are installed within the same mechanical spaces, electrical code requirements call for a single electrical shutoff for emergency use. It is the responsibility of the electrical designer to comply with local codes and regulations affecting an individual installation. 12/01/2016 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 7 of 8

GF-2060 Benchmark Series Boilers Change Log Date Description Changed By 11/08/2013 12/01/2016 Rev I: Changed 460V BMK 6000 from 15A to 20A and added Diagram 8 wiring and table column. Rev J: PIR 998-1: Addition Of 575V Option For BMK 6000. Clarified Power Options in Section 2 and in Diagrams. DIR 359: Addition restriction added to section 4 Boiler Wiring Curtis Harvey Chris Blair AERCO International, Inc., 2016 Page 8 of 8 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 12/01/2016