General & Technical Specifications:

Similar documents
General & Technical Specifications

Technical Specifications

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Specifications

Technical Specifications

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Concert Hall Technical Specifications

Marjorie S. Deane Little Theater

Patriots Theater at the War Memorial Technical Data

Dale F. Halton Theater Technical Specifications

Concert Hall Technical Specifications

Technical Specifications

Technical Services and Specification

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Sandusky State Theatre Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Bloomington Center for the Performing Arts. Technical Specifications

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Arcadia Performing Arts Center Technical Specifications and Information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

SAINT ANSELM COLLEGE DANA CENTER

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

NORTH CHARLESTON PERFORMING ARTS

Main Stage Technical Specs - Hall #2

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

SHUBERT THEATER 247 College Street, New Haven, CT

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Technical Specifications

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

NORTH CHARLESTON PERFORMING ARTS

TECHNICAL PACKAGE.

Technical Specifications

Technical Information

Technical Specifications and Inventory Spring 2018

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Dr JOHN GALLAGHER CONCERT CHAMBER

Clayton Center for the Arts Ronald and Lynda Nutt Theater Technical Specifications December 2014

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Hard Rock Cafe Times Square Sound System Advance Sheet

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

Facility Information

Technical Information

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Technical Specifications

Technical Specifications. Taylor Little Theater

TECHNICAL INFORMATION & SERVICES

Dinkelspiel Auditorium - Technical Specifications

Bologna Performing Arts Center Technical Information Package Delta & Pine Land Theatre

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Downtown Arts Center Tech Packet. General Information

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

PARAMOUNT ARTS CENTER ASHLAND, KENTUCKY

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Baker Hall Technical Information Package

P.O Box 1171 Box Office & Theatre: (903) Main St Texarkana, TX TRAHC Office: (903) Texarkana, TX Fax: (903)

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Ferst Center for the Arts Technical Specifications (Revised May 2016)

ROBERT M. MERRYMAN PERFORMING ARTS CENTER TECHNICAL INFORMATION PACKET

FOX THEATRE ST. LOUIS

NORTH CHARLESTON PERFORMING ARTS

Camden Opera House Theater. Technical Information

PRODUCTION INFORMATION

Center Theater Technical Information 9/1/12

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

SECREST AUDITORIUM TECHNICAL PACKAGE

Contact Information. Karen Jones Accounting Specialist Phone:

JOHN W.H. BASSETT THEATRE

PARAMOUNT ARTS CENTER ASHLAND, KENTUCKY

Dr. Fred Speckeen Theatre. Information and Technical Specifications

GENERAL INFORMATION. Front of House Services: Theater Director Peter Palermo O:

Vern Riffe Center for the Arts Technical Information Packet for Users Seating capacity Stage configuration CONCERT HALL PROSCENIUM THEATER

Performing Arts Theatre

Lighting Information

FIVE FLAGS THEATER SERVICES STATEMENT

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Jacoby Auditorium - Technical Rider UCC Special Events Office Phone:

Technical Informa on.zack Theater

STAGE ELECTRICAL 1 OF 1. - COMPANY SWITCH - SERVICE OPTIONS: - 3-Phase, 4-Wire, 208V Amps per Leg: Phase, 4-Wire, 208V

Jane Mallet Theatre Technical Specifications

The Temple Hoyne Buell Theatre

Schauer Arts and Activities Center Technical Information Touring Companies

Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

Matt Dann Cultural Centre

Stephen B. Humphrey Theater

The Port Theatre Technical Specifications

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

THE MORTENSEN HALL. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Transcription:

General & Technical Specifications: Physical Address: Seating Capacity Proscenium Opening: Stage Depth: Stage Width: Stage Height: Orchestra Pit: Stage Floor: Crossover: Loading Door: East side of San Carlos Street between Eighth and Tenth Avenues Carmel-by-the-Sea, California 93921 718 seats, including: 12 balcony box seats 13 removable seats for ADA wheelchair access 48 seats located on the Orchestra lift (These 48seats are permanently attached to three seat wagons which store under the main seating area in order to use orchestra pit or thrust stage.) 40 wide by 37 high at the peak of the arch. (Note: main valance reduces opening height to 18 9 ). 39 plaster line to back wall. 42 7 apron to back wall 54 orchestra pit/ thrust stage down stage edge to back wall (Note: front edge of apron and thrust stage are curved and measurements are taken on centerline at the furthest down stage point of the arc). 33 Centerline to locking rail stage right 62 centerline to stage left wall, (50 clear and useable) 40 stage floor to batten high trim 43 stage floor to grid 9 below stage floor 14 deep by 28 wide (approx~390sq.ft.) Pine tongue and groove floor sprung on rubber bushings for dance with matte black finish Hallway upstage of backstage wall with entrances to stage right/left wing areas 10 high x 10 wide, Direct access from ground level to up stage left wing area 1

Rigging: Soft Goods: 38 single purchase line sets 56 long including house hang Locking rail is stage right 33 working line sets; first two are main valance and main drape Three more dedicated line sets for orchestra Wenger Diva shell clouds are interspersed at 1/3 rd intervals through the line set schedule 1700 lb. Maximum load per arbor 50,000 lb. of counter weight available Main drape and Main valance red/wine color 150% fullness both travel Legs and borders are sewn flat (fullness can be tied in) 4 sets of legs 15 w X 23 h 5 borders 85 w X 10 h 1 border 85 w X 5 h 1 Traveler (mid stage) 150% fullness 1 black seamless scrim 50 w X 22 h 1 leno filled seamless white cyclorama 50 w X 24 h Lighting Equipment: Dimmers: ETC Sensor Dimmers 3 SR96 racks loaded with 240 dimmers 119 D20E dual 20A 800ms rise time dimmers 2 D50AF single 50A 800ms rise time dimmers Control: ETC Expression3 800 800 channels 1536 dimmers Software V3.1 1 remote focus unit House Lights: controlled by ETC unison system or Expression3 DMX Distribution: 6 ETC DMX Net2 nodes (up to 4 DMX inputs/outputs) 1 ETC DMX Net2 portable node (up to 4 DMX inputs/outputs) 24 network ports for portable and additional nodes (Note: Nodes normally operate in Net2 mode.) Circuits: 208, 20A 2P& G (stage pin) 2, 50A 2P& G (stage pin) Distributed as follows: 2 Spot booth 9 Balcony rail 48 FOH catwalk 2 50A @ FOH catwalk 2

Lighting Instruments: Sound Equipment: 15 6 circuit multi drops stage left (for electrics battens) 2 6 circuit multi drops stage right (for electrics battens) 24 Located in floor pockets (4 SR/4 SL, 3 circuits per) 6 Down stage wall (3SR/3SL offstage of proscenium arch) 12 Up stage wall (4 groups of 3 SL-SR) 3 Wall mounted circuits in orchestra pit # Brand Unit Wattage 58 ETC source-4 ellipsoidal bodies 750 Source-4 ellipsoidal lenses (or barrels): 19 degree = 12 26 degree = 24 36 degree = 23 50 degree = 7 14 ETC 15-30 source four zoom 750 23 ETC source four Parnell 750 4 Altman 6X22 Ellipsoidal 1K 8 Altman 6X12 Ellipsoidal 750 18 Altman 6X9 Ellipsoidal 750 6 Altman 4 ½ X 6 Ellipsoidal 500 2 Altman 3 ½ X 6 Ellipsoidal 500 25 Altman 8 Fresnel 1K 18 Altman 6 Fresnel 500 16 Altman PAR 64 1K (MFL) 6 Strand PAR 64 1K (MFL) 20 Altman 1 window Sky Cyc 1K 9 Altman 6 R/40 Strip light 150 MISC. 8 50lb. Boom Base w/ pipe for 12 trees Various extra ETC source four barrels for ellipsoidal instruments 6 & 8 barn doors, side arms, pattern holders: 17Altman, 19 source4 Approximately 1000 12/3 cable various lengths 5-40 Console: Crest X Eight: 40 mono input channels sweep able HPF, HF bell curve, parametric HM& LM EQ, LF bell@ 80hz, 4 stereo input, 8 sub groups, 8 aux 3

Speakers: Amplifiers: Speaker Management: 6 EAW kf740p loudspeakers flown in clusters of two Left, Right, and one left/right in the center cluster 2 EAW SB 750 Subwoofers in orchestra pit or can be moved onstage 4 Meyer UPM-1P self powered front fill speakers on down stage lip 6 EAW SM129z monitor wedge speakers 2 tweeter 12 woofer 2 EAW SM159z monitor wedge speakers 2 tweeter 15 woofer (permanent install, cannot be moved or reconfigured) 3 Crown MA1202 (HF) 3 Crown MA2402 (MF) 3 Crown MA3600VZ (LF) 2 Crown MA5002VZ (Sub) 2 Crown MA1202 (stage monitors) 2 Crown USM-810 (No access to house curve or crossover) Microphone Inventory: - Signal Processing- 2 DBX 1046 Quad compressor/limiters (total of 8 channels) 2 DBX 1074 Quad noise gates (total of 8 channels) 2 Yamaha SPX 990 reverb units 4 Klarke Tecknik DN 360 graphic equalizers (total of 8 bands) -Dynamic Microphones- 4 Shure SM- 57 4 Shure SM- 58 2 Shure Beta 57 4 Shure Beta 58 2 Electro Voice RE-20 2 Sennheiser 421 - Condenser Microphones- 1 Shure VP- 88 stereo two input channel (Left-Right) 2 Shure SM- 81 2 Neumann KM- 184 2 AKG C414B-XLS 2 AKG C300B (CK 92 capsule) 2 Langevin CR-3A - Wireless microphones 1 Shure U4D-M4/B87 dual wireless receiver (662-692 MHz) (This unit has two Beta 87A, and two body pack transmitters with standard Shure, or optional countryman mic elements.) 4

- Miscellaneous Microphones - 1 Shure MX412S/S podium microphone 1 Shure SM- 58 with switch (Located at front of house for talk back to monitors) 3 Crown PCC- 160 boundary microphones - Miscellaneous - 4 Type 85 Countryman direct boxes 1 Whirlwind Direct2 dual input direct box 1 Pro-Co model AV-1 (AV sound interface) 10 Atlas boom stands round base 6 AKG boom stands tripod large 4 AKG boom stands tripod small 2 Atlas boom stands w/large round base 2 small boom stands w/ round base Playback: Sound Power: Sound Wiring: Control Locations: Hearing Assist: Monitor/Paging: 1 Dennon DN-D6000 dual CD player 1 Sony PCM-R300 2 track dat player/recorder 1 Sony Single minidisk player/recorder 1 Marantz PMD-320 CD player 1 Marantz PMD-501 cassette player/recorder All sound power is on the same branch with its own isolated ground 32 channel console input snake 24 channel console output snake 32 channel monitor input snake (transformer isolated split) (Note: all house channels are terminated at a patch bay in the FOH sound booth.) Booth is~ 10X10 with a 9 X4 window Aux mix position #1 is located at balcony lip center of house Aux mix position #2 is located house left under balcony (Note: #2 position is not recommended) Listen lt-800vhf transmitter Coverage/zones: Large outer lobby, front of house areas i.e. inner lobby, hallways bathrooms etc, dance studio/ warm up room, back of house areas: greenroom, dressing rooms, various production offices, etc Program inputs: Console matrix #1, Hanging Sheops mics, lobby mic input, and backstage paging mic 5

Production COM: Clear-com SB-440 4 channel with 10 output matrix 2 RM-400 remote master stations 10 RS-502 dual channel belt packs with headsets 4 WTR-680 wireless headsets Variable Acoustics: Acoustic dampening curtains on back and side walls of auditorium 9 Wenger Diva acoustic shell towers 20 high 3 Wenger Diva acoustic ceiling panels clouds with 16 ETC source four par in each LARES (Lexicon Acoustic Reinforcement and Enhancement System) Company Switch: (1) 120V 3phase 200Amp (bare wire or cam-lock connector) located stage left (1) 120V 3phase 400Amp (bare wire or cam-lock connector) located up stage left wall near crossover 6