Theatre Technical Specifications

Similar documents
CENTRE FOR PERFORMING ARTS

Technical Specifications

Matt Dann Cultural Centre

Mics, DIs, Stands, and Cables

RPAC REDLANDS PERFORMING ARTS CENTRE

2017 TECHNICAL SPECIFICATIONS

Technical Specification for the Alley Theatre, Strabane

Technical Data Sheet

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Access to back stage is off Fletcher St on the eastern side of the building

Dr JOHN GALLAGHER CONCERT CHAMBER

Downtown Arts Center Tech Packet. General Information

Technical Specifications

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Technical Specification

Concert Hall Technical Specifications

Technical Services and Specification

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Concert Hall Technical Specifications

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Summary. Access and Parking

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

Technical Pack. Attenborough Arts Centre

HIRE AND TECHNICAL INFORMATION

Technical Specification

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

There are 10 dressing rooms in Theatre Kerkrade.

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Anvil Theatre. Technical Information

Sandusky State Theatre Technical Specifications

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Marjorie S. Deane Little Theater

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Patriots Theater at the War Memorial Technical Data

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Specification (Studio Theatre)

Arcadia Performing Arts Center Technical Specifications and Information

350 fixed seats with the capabilities of an additional 50 removable seats.

Technical Specification

Main House Technical Specification

Technical Specification (Studio Theatre)

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

TECHNICAL SPECIFICATIONS

INFORMATION FOR VISITING COMPANIES

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

The Haymarket Basingstoke Technical Specifications

ISLAND HALL TECHNICAL INFORMATION

Technical Specifications. Taylor Little Theater

Technical Information

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Jane Mallet Theatre Technical Specifications

A Technical Guide to the Faith Center

DEREHAM MEMORIAL HALL

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Main Stage Technical Specs - Hall #2

Main House Technical Specifications

Technical Specification Pavilion Dance

Latrobe Performing Arts Centre

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Cornerstone Technical Specifications 2018 / V1

Technical Director of Production Andrew Quick Ext 252

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

CHELSEA THEATRE. Technical Specifications

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

332 fixed seats (max capacity) with reserved space for disable access

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Dinkelspiel Auditorium - Technical Specifications

Technical Informa on.zack Theater

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Zach Vander Missen Muhammad Farooq Garrett McMindes

Camden Opera House Theater. Technical Information

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Hopgood Theatre NOARLUNGA CENTRE

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Technical Information

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Technical Specifications

John Leslie Theatre. Technical Specifications. Updated July 2018

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

AUDIO SPEAKERS / AMPLIFICATION

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Technical Specifications Nov 2016

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Monty Kultuurfaktorij Technical Rider

Visy Theatre technical information and general specifications 2019

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Ed Blackwell Production Manager Mike Weller Head of Music

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Shouson Theatre Venue Specifications (updated Jan 2017)

TECHNICAL PACKAGE.

Project manager (PM): Pamela Næss Mail: Phone:

THEATRE EQUIPMENT DECEMBER 2017

Transcription:

Theatre Technical Specifications

The Lakes Theatre STAGING INFORMATION Seating Capacity: Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height 6.8m Stage Floor: Sprung floor of 19mm ply (painted black) House Draperies: House Curtain 1 x black wool 2 piece Left & Right Draw pulley system Front Gauze 1 x black wool 2 Piece Left & Right Draw Rear Gauze 1 x black wool 2 Piece Left & Right Draw Wings 4 x black wool 1 Piece 2 x Right, 2 x Left Cyclorama 1 x white filled cloth 5.8mt x 13.4mt Elevated Work Platform: 1 x Genie 2032 Scissor Lift (Authorised use only) 1 x Aluminium Scaffold 5m working height platform Dressing Rooms/ Green Room: 1 x Male complete with shower and toilet (Stage Level) 4 x makeup stations with lighting & mirrors 1 x Female complete with shower and toilet (Stage Level) 4 x Makeup stations with lighting & mirrors Loading Dock: 1.8mt wide x 2.9mt high dock door Loading Dock is at stage Level and can open up onto stage

AUDIO INFORMATION The Sound Desk is located Centre Back of Theatre, Sound, Lighting, Av are all operated from the same location. The system is a D&B line array system driven by a Midas Pro 2 Desk. Any additional equipment needed is easily added as the Theatre has been future proofed. Main control: Midas Pro 2 IP 1 x Midas DL151 fixed format I/O Unit -24 in stage box 2 x Midas DL153 fixed format I/O 16 remote control mic inputs & 8 outs each. Input (external): 3.5mm stereo input jack Tascam CD-200SB CD/MP3/USB Player Speakers and Amps: 2 x D&B professional Line Array (L&R), each side consisting of 2 x D&B V8 Speakers, 8 x D&B V12 Speakers 2 x D&B V subwoofer Floor positioned, 2 x D&B J infra subwoofer 6 x D&B D12 dual channel mainframe amplifier controllers/ep5. 1 x D&B R70 Ethernet to CAN Interface 1 x D&B QI7 4 x D&B D6 dual channel mainframe amplifier controllers 2 x D&B Q7 Side fill Speakers 9 x D&B Max 12 monitors 1 x D&B s18 Sub (Drum infill) Video Specs: Roland V800HD Video Switcher 2 x imac Desk top 1 x MacBook Pro 1 x Black Magic URSA EF Cinema Camera Microphones Wireless: 3 x Shure ULXD Quad Channel Digital Receivers 6 x Shure ULXD1 Wireless Digital Body pack 6 x JTS Headsets 2 x Shure SLX receivers 6 x KSM9 wireless handheld s 2 x Beta58 Wireless Handheld s 3x MiPro dual channel receivers 6x MiPro Belt packs 6x JTS Headsets

Microphones Cabled: 5 x Shure SM58 Mics 4 x Shure SM57 Mics 2 x Rode M3 Condenser Mics 4 x Rode NTG1 Shotgun Mics Roof Mounted 4 x Crown PCC160 Plate Mics 1 x PG 52 Kick Drum Mic 3 x PG 56 Snare/ Tom Mic 2 x PG 81 Condenser Mics 2 x Australian Monitor DI Box 2 x Behringher Ultra DI Box 12 x Grey K&M Starline mic stands & Booms 1 x K&M Round Base Mic Stand Patching: 2 x Midas DL153 fixed format I/O 16 remote control mic inputs & 8 outs each. 1 x Midas DL151 fixed format I/O Unit -24 in stage box 3 x Pits - Stage Front Centre, Stage Front Left, stage front right Each Pit Contains 2 x XLR Inputs and 2 x NL4 Returns LIGHTING INFORMATION The Theatre incorporates two fixed Jands 12 channel dimmer units (total 24 channels) controlled via a Jands vista control system. The House system is operated from the control Desk at the rear of the seating. Dimmers are located backstage in a storeroom. All lighting outlets are above stage on lighting bars each bar has DMX connectivity. Dimmers: 2 x Jands 12 ch Control Board: Mac Computer running Jands Vista V2.3 with S1 work surface. Luminaries: 32 x LED ProShop Multipar Quadcolour 18x4w RGB+CW 8 x LED ProShop Quadcolour Bars 18 x 4w RGB+CW 8 x ETC Source 4 x 750w Profile zoom Spots

6 x Martin RUSH MH1 Profile Plus Moving Heads Follow Spot 1 x DTS Moon 1200 Lighting bar Positions: 1 x FOH Lighting Bar 5 x Over stage Lighting Bars Stage Lighting can be modified as per Show requirements Data Projector: AUDIO VISUAL INFORMATION 2 x Hitachi Fixed projectors Stage Left and Right 1 x BenQ Fixed Projector Stage Centre Screens: 2 x Fixed Front Projection 130 4:3 Computer: 1 x Mac Computer (Running Pro Presenter software) Lectern: 1 x Lectern Additional information: 1 x VGA Input connection Available stage front centre 1 x VGA Output connection Available stage front centre 1 x Stereo Pc Audio input available stage front centre (XLR to 3.5mm jack) 3 Phase Power located Stage Rear Right and backstage in storeroom Single Phase Power located Stage Rear Left and Right Stage Front Centre Pit Contains 1 x 2 Outlet PowerPoint

Technical Staff Contact: James Waldeck jameswa@mbc.wa.edu.au Nathan Cox - nathanc@mbc.wa.edu.au Telephone: 08 9583 7000

Site plan of Theatre and surrounding College. THE LAKES THEATRE

Stage lighting Amp Rack Loading Dock Cable Patch Sound Lighting / Projector Control