INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

Similar documents
LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

LANmark-OF ENSPACE Patch Panel

Optical Distribution Box 300 Installation Guide. Version : R0.0

Medium Box for Cable Termination

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

HCS - HES Cabling Systems

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Cable Installation Tips

Cable Installation Tips

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

RetractaNet XS. Extractable Solutions for OSP. October 2012

3M Distribution Box (DDB)

IP-LINX. Installation Guide

Preferred ordering guide for NETCONNECT

3M Fiber Optic Wall Mount Enclosure 8430 Series

Panduit Recommended Best Case Practice Split Fibre

Gel-sealed in-line fiber optic closure

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Connectix Cabling Systems

OPTICAL FIBRE CABLE NETWORK 2004/1

INSTALLATION INSTRUCTIONS

Installation Instructions

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

IP-LINX Fiber :: X-XXXX

Section Communications Optical Fiber Backbone Cabling

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

INSTALLATION INSTRUCTIONS MO023A

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

FIBRE OPTIC CABLE SOLUTIONS

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

SECTION 4 TABLE OF CONTENTS

Termination Instructions. FO Patch panel OV-A / OV-AT 19 /1U. Cabling Solutions

Connectivity accessories by Nestor Cables

Smart Choices. for Data Center

LANmark. Copper Cabling Solutions

Ordering Guide. for FIST-GSS2 product range

FOSC 450 C6 and D6 Closures

Follow The Leader In Shielded Technology

Public Works Division Lighting District Fiber Optic Specifications April 2009

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Crimp & Cleave Termination Instructions for SEL ST Connectors

3M Coupling Tray FDTC-10S-COUPLINGTRAY

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

Enterprise Networks. Comms Room and Backbone. in DETAIL

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

Fiber Optics Redefined

Triax TechInfo. Installing and pulling Fibre Optic cables

Fiber Optic Splice Closure GPJ Instruction Manual

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

FACT Cable Termination Unit

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

HI-DEX PRODUCT SET DATASHEET

3M No Polish Jacketed SC/APC Connector

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

3M Fiber Closures BPEO

18mm ECAM Cable Entry Port

FIST-GCO2 GCO2-BC8 GCO2-BD8 GCO2-BE8 GCO2-BF8. 5 Heatshrink installation. 1 Introduction. Content. 6 Fiber routing. 2 General. 7 Fiber routing on tray

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

SLiC Fiber Aerial Closure System

Customer-Owned Outside Plant

Opterna. Sliding Fiber Optic Patch Panel. Sliding Fiber Optic Patch Panel. Visit: Opterna.com. Data Center Solutions. Introduction

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

Best Friends General Trading FZE

INSTALLATION INSTRUCTIONS

SPECIAL SPECIFICATION 6559 Telecommunication Cable

Product Range Nexans Cabling Systems

Fibre Optic Cable & Connector Guide

SPECIAL SPECIFICATION 8540 Telecommunication Cable

27mm ECAM Double Cable Entry Port

Data Centres. Smart Solutions for 300 M OM4 120 M 120 M 400 M. Cat 8 30 M 85 M. Cat 7A 30 M OM3. Cat 6A 100 M OM4 OM3 85 M OM3 900 M 40G 40G 25G 100G

UQ ICT Cabling Specification

LGX Compatible (LSX) Connector Module) User Manual)

Optimax Field Installable Connectors and Installation Tool Kits

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Min Dynamic Bend mm. Min Static Bend mm. EF 008 Uni4 L STA LU FS. EF 008 Uni8 L STA LU FS. EF 008 Uni12 L STA LU FS. EF 008 Uni16 L STA LU FS

ULTRA HIGH DENSITY SOLUTION GUIDE

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter

Transcription:

LANmark-OF Zone Distribution Box INSTALLATION GUIDE LANmark-OF Zone Distribution Box

Document information Release November 2004 Published by Contact address Nexans Cabling Solutions Alsembergsesteenweg 2, b3 1501 Buizingen Belgium Phone +32 2 363 38 00 Fax +32 2 365 09 99 Website E-mail www.nexans.com/ncs info@nexans.com Important Notice The information contained in this document has been carefully checked and is assumed to be entirely correct and reliable at the time of publishing. However, Nexans Cabling Solutions reserves the right to make such changes to its products or its documentation as it deems necessary, in order to make improvements. Nexans Cabling Solutions rejects all responsibility for the use made of its products or of its documentation. In this document, no mention is made of rights with respect to trademarks or tradenames which may attach to certain words or signs. The absence of such mention, however, in no way implies that there is no protection. 2004 Nexans Cabling Solutions

INSTALLATION GUIDE FOR LANmark-OF Zone Distribution Box TABLE OF CONTENTS Preparation of the ZDB...3 Choosing connector types...4 Fibre termination...6 Direct connectorisation...6 Termination with fusion splicing...8 Finalization of the installation...11 Important Remark Installation is to be performed by qualified service personnel Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 1

LANmark-OF Zone Distribution Box The Installation of a Fibre Zone Distribution Box must be carried out with care and precision. Make shure to work on a clean and level work surface. In the package following items are included: 1 Zone Distribution Box 2 small bolts 1 Nut to fix splicetrays on the fixed bolt All other products must be purchased seperatly, the product numbers are mentioned where needed. Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 2

Phase 1 Preparation of the Zone Distribution Box Leave some extra cable (± 5m) at different places on the cable link. This makes it easier to repair in case of a broken cable. A minimum of 3 meters OF cable should be foreseen at the ZDBox side the as this will facilitate the termination of the cable in the OF ZDBox. Preferably do the termination of the OF in the ZDBox on a table before screwing the ZDbox into it s final place. Always cut the first meter of cable as this part can be damaged after pulling the cable, bending, water damage... More specific installation guidelines on indoor optical fibre cable can be obtained from our Optical Fibre Indoor Cable INSTALLATION GUIDE which is available from our NCS website. Remove the top cover. Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 3

Fixation of the ZDBox can be done with four optional screws. Special holes are foreseen in every corner. The advantage of the Snap-in ZDBox is the flexibility to accept different types of couplers and connectors. Four versions can be installed by using the LANmark snap-in couplers. These couplers must be purchased seperatly. Available couplers are: DSC, SC, 2LC and MT-RJ Please be aware that patchcords with a DSC connector are not compatible with two separate SC couplers. The orientation of the key member is different. Please consult the list below. Phase 2 Choosing connector types N205.611 LANmark-OF Snap-in Adapter 2LC-2LC Multimode N205.621 LANmark-OF Snap-in Adapter 2LC-2LC Singlemode N205.614 LANmark-OF Snap-in Adapter DSC-DSC Multimode N205.624 LANmark-OF Snap-in Adapter DSC-DSC Singlemode N205.612 LANmark-OF Snap-in Adapter MT-RJ - MT-RJ N205.613 LANmark-OF Snap-in Adapter SC-SC Multimode N205.623 LANmark-OF Snap-in Adapter SC-SC Singlemode LC Duplex SC MT-RJ SC Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 4

First remove the protective caps on the front of the couplers. Snap the couplers into the ZDBox by hooking the top of the coupler under the front mounting plate and then lowering the coupler into its aperture.! Make sure to keep the protective caps in place on the back of the couplers during installation to avoid ingress of dust. Do not remove the shutters. To remove the coupler: put a small screwdriver under the connector in the opening to unlock. Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDBl - 5

Phase 3 Fibre termination Two termination practices are supported depending the used construction of your fibre cable. In case of loose tube construction we advice to fusion splice to pigtails using a splice tray for protection. Due to the fragile nature of the 250µm fibre we advice not to use direct connectorisation a special microtube (N890.045) must be used to protect the fibre when direct termination is chosen. In case of tight buffer constructions both fusion splicing with pigtails and connectorisation are possible. Following table may help you choose the preferred method. Loose tube 250µm fibres SC LC MT-RJ Fusion Splicing MM Yes Yes Yes Connectorisation MM Yes, with microtube Yes with microtube NO Fusion Splicing SM Yes Yes NO Connectorisation SM Not advised or with microtube Not advised or with microtube NO Tight Buffer 900µm fibres SC LC MT-RJ Fusion Splicing MM Yes, Yes, Yes, using Heatshrink splice protectors using Heatshrink splice protectors using Heatshrink splice protectors Connectorisation MM Yes Yes No Fusion Splicing SM Yes, Yes, Yes, using Heatshrink splice protectors using Heatshrink splice protectors using Heatshrink splice protectors Connectorisation SM Yes Yes No Phase 3A Direct connectorisation Remove 1 meter of the outer sheath and the aramid/glass yarns from the cable. Consult specific guidelines on removing the outer jacket depending the construction. Avoid damaging the fibres while cutting the outer jacket and yarns. For 250µ fibres the tube must be removed leaving at least two loops in the ZDBox. Make sure to clean the fibres with De-Solv-It to remove the gel. 1000 Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 6

You must use an optional cable gland (PG-16) to bring in the fibre cable at the back. Fix a permanent label on the fibre cable for future identification. Make sure the cable is fixed in the cable gland. Provide at least two spare loops in the ZDBox. Measure the length of each fibre to the coupler respecting both bending radius and the color order and cut the rest of the fibre. Take the fibres out of the ZDBox and mount the connectors on the fibres. When mounting connectors on 250 µ fibre you will need to use an optional microtube (N890.045) to reduce risk of damaging the fibre. It is advisable to label the fibres for easy identification. Remove the dust protection caps on backside of the couplers where connectors will be inserted. A quick cleanness check of the couplers may be advisable. Compressed air or alcohol can be used to clean the couplers if there is ingress of dust. Loop the fibres back in the ZDBox and insert while respecting the colour coding the mounted connectors in the couplers. The fibres can be held together with tie wraps. The Recommendations to maintain duplex OF channel polarity technical paper, which is available from our NCS website, should be considered when choosing the colour order. Continue with Phase 4 Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 7

Phase 3B Termination with fusion splicing In case of tight buffer fibre: Un-strip the fibre cable to a length of at least 1 meter to allow enough spare fibre for later maintenance purposes. Consult specific guidelines on removing the outer jacket depending the construction. Avoid damage to the fibres while cutting the outer jacket and yarns. 1000 In case of loose tube fibre: Remove 1 meter of outer sheath from the tube. Use the correct tools in order not to damage the fibres while cutting the tube. An optional cable gland (PG-16) has to be used to affix the cable to the ZDBox. Fix a permanent label on the fibre cable for future identification. Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 8

Up to 2 splice trays may be installed to hold up to 24 fibre splices. Splicetrays for fibre splice protections are available in metallic or heatshrink versions. It is advisable to install a maximum of 12 splice protections per tray. Fix the first splicetray over the bolt in the ZDBox with the nut. Remove the tube from the fibre over a length to allow fixation in the splicetray (A) by means of tie wraps. Clean the fibres with De-Solv-it to remove the gel. Make sure to have at least two loops of loose fibres in the splicetray. Up to twelve fibres can be installed using a heat shrink or a metallic protection splicetray. In case of using a fibre cable with more than 12 250µm fibres separation of extra fibres is needed. This can only be done by splitting the fibres with an optional Y- Splitter module N890.144 (C) + 2 lengths of empty tube for splicetrays N890.145 to insert the fibres for protection. Remove the dustcaps from the couplers on the inside of the ZDBox. A quick cleanness check of the couplers may be advisable. Compressed air or alcohol can be used to clean the couplers if there is ingress of dust. Insert the connectors of the pigtails in the couplers. Measure the length of the 900µ buffer needed to fix the pigtail in the comb (B) of the splicetray keeping in mind a minimum bending radius. The fibres from the pigtails should make at least two loops in the opposite direction. Our Maxi strip pigtails allow to remove the 900µ buffer in one go after being cut at the right length. Cut the first 12 fibres to the right length and joint them by fusion splicing with pigtails respecting the colour sequence. The Recommendations to maintain duplex OF channel polarity technical paper, which is available from our NCS website, should be considered when choosing the colour order. C A B Up to 2 splice trays can be installed if needed. Don t forget to label the pigtails. Close the splice tray with the cover and fix with the nut. Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 9

Protect the splices with a metallic N890.003 or a heat shrink splice protector N890.021. Fixate the splice protector into the correct splicetray at the designated place and gently loop the fibres back in the splice tray. For splicetray with metallic splice protection use N890.010 For splicetray with heat shrink protection use N890.020 For splicetray cover use N890.022 After installation of the first splicetray you may insert the other fibres from the same cable in the empty tube and fix the tube to the second splicetray and fusion splice the left over fibres. Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 10

Phase 4 Finalization of the installation The ZDBox can now be gently closed, fix the top lid with the 2 small bolts on the sides and then install the ZDBox in the designated place by means of screws if not already done. Loop the extra fibre cable back in a safe place while respecting minimum bending radius. Label the ports conform the company policy. The ZDBox is now installed. The ZDBox also has a bolt at the back if connection to the earth is requested Do not remove the shutters on the front of the ZDBox because they prevent ingress of dirt in the couplers. Patchcables can be connected easily just by opening the shutters at the front. Nexans Cabling Solutions Installation Guide Optical Fibre LANmark-OF ZDB - 11