DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, DUMMY STOWAGE, SERIES III, METRIC

Similar documents
DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, JAM-NUT MOUNTING, REMOVABLE CRIMP CONTACTS, SERIES III, METRIC

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, JAM-NUT MOUNTING, REMOVABLE CRIMP CONTACTS, SERIES III, METRIC

DETAIL SPECIFICATION SHEET CONNECTORS, PLUG, ELECTRICAL, RFI SHIELDED, SERIES 2, CRIMP TYPE, BAYONET COUPLING, CLASSES A, D, L, T, W AND K

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, SOLDER OR WELDED FLANGE MOUNT, BAYONET COUPLING, SOLDER PIN CONTACT, CLASS H, SERIES 2

INCH-POUND MIL-PRF-39012/29H w/amendment 3 25 January 2018 SUPERSEDING MIL-PRF-39012/29H w/amendment 2 21 November 2016

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES BNC (CABLED), PIN CONTACT, CLASS 2)

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES TNC (CABLED), PIN CONTACT, RIGHT ANGLE, CLASS 2)

INCH-POUND MIL-PRF-39012/28H w/amendment 4 25 January 2018 SUPERSEDING MIL-PRF-39012/28H w/amendment 3 15 April 2017

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES BNC (CABLED), PIN CONTACT, CLASS 2)

PERFORMANCE SPECIFICATION SHEET

INCH-POUND MIL-PRF-55629/21G 10 March 2010 SUPERSEDING MIL-PRF-55629/21F 21 September 2005 PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, CATHODE RAY TYPE 7AGP19

The requirements for acquiring the product described herein shall consist of this specification sheet and FF-N-836.

DETAIL SPECIFICATION SHEET CONNECTOR, FIBER OPTIC PLUG, CIRCULAR HERMAPHRODITIC, IN-LINE MOUNT, 2 AND 4 POSITIONS, EXPANDED BEAM

MILLITARY SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE THREE-POLE, AUXILIARY CONTACTS

PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSHBUTTON, ULTRA-COMPACT, LED ILLUMINATION, NVIS, SEALED

DEPARTMENT OF DEFENSE STANDARD PRACTICE

TE Connectivity DEUTSCH DL Series MIL-DTL Series III Connectors

MILITARY SPECIFICATION SHEET

Jul03 Rev C EC

AMERICAN NATIONAL STANDARD

PERFORMANCE SPECIFICATION SHEET

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH

ENGINEERING COMMITTEE

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

Downloaded from

bmam connectors DIVIDER PAGE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

The Next Generation Connector

Mar11 Rev E

DETAIL SPECIFICATION CABLES, LIGHTWEIGHT, LOW SMOKE, ELECTRIC, FOR SHIPBOARD USE, GENERAL SPECIFICATION FOR

EVERY TWO YEARS 24 November 2000 SUPERSEDING QPL June 1998 QUALIFIED PRODUCTS LIST PRODUCTS QUALIFIED UNDER DETAIL SPECIFICATION

8D with High Frequency Coaxial Contact

TE Connectivity DEUTSCH ACT Series MIL-DTL Series III Composite Connectors

TITLE: FIBER OPTIC SHOCK FIXTURES

GT Dual-Row Nano Vertical Thru-Hole High Speed Characterization Report For Differential Data Applications

Drop Passives: Splitters, Couplers and Power Inserters

TE Connectivity DEUTSCH DJT Series MIL-DTL Series I Connectors

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Specification for F Connector, Male, Pin Type

PERFORMANCE SPECIFICATION SHEET

AMERICAN NATIONAL STANDARD

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Type "N" Connectors. Type "N" Interface Dimensions

Non Magnetic Connectors Product Catalog

EXPlora. Introduction

Medium Weight Shock and Vibration Test Report on 3 x 1 1/2 x 6 15 HP Pump for Sims Pump Valve Company Hoboken, NJ

Series SMPM-T. Description. Compatibility. Content. Interface dimensions (mm/inches) SMPM-T male (pin contact), smooth bore

ENGINEERING COMMITTEE

Interface Practices Subcommittee SCTE STANDARD SCTE Specification for Mainline Plug (Male) to Cable Interface

Medium Weight Shock and Vibration Test Report on 3 x 1.5 x 8 Pump with 30 HP Motor for Sims Pump Valve Company, Inc. Hoboken, NJ

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

CLT-353R & CLT-353L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.1, 4/19/2013 preliminary

SMA - 50 Ohm Connectors

Pivot Power RJ45 Modular Plug Connectors

Aerospace Fiber Optics

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Connector, OPTIMATE*, FSMA 905 & 906, Fiber Optic

eclipse HYBRID POWER & SIGNAL THE SCIENCE OF CERTAINTY M06U-NC For use in power supplies, server equipment and related hardware

SERIES HPQN CONNECTORS

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

ADF Module. Installation Guide. 1.1 Overview

Fibre Optic Connectors

DS1 Cross-Aisle Panel

INSTALLATION INSTRUCTIONS FOR

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. Test Method for Moisture Inhibitor Corrosion Resistance

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

Cable Retention Force Testing of Trunk & Distribution Connectors

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

EZ-MATE CONNECTORS The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems

Non Magnetic Connectors

RF/Microwave Connectors & Cable Assemblies

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Mustang Series Fast Ethernet, TFOCA II, 100Base- TX / FX Media Converter, Multimode, 1310nM, USB Powered - 5.0VDC

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Look No Further... Materials & Finishes. Specifically made for all your: Gigabit Ethernet, HDMI, USB 2.0/3.0 Needs! onnectors

Parameter Input Output Min Typ Max Diode Option (GHz) (GHz) Input drive level (dbm)

TGL2209 SM 8 12 GHz 50 Watt VPIN Limiter

SECTION 9 BNC/BNC 75 HDTV/BNC-TRX R141/R142/R266 SIMPLIFICATION IS OUR INNOVATON. Visit for more information

Tape and Reel Packaging for Semiconductor Devices. Technical Data

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

GT Dual-Row Nano Vertical SMT High Speed Characterization Report For Differential Data Applications

ENGINEERING COMMITTEE

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

SECTION 10 BNC / BNC 75 HDTV / BNC-TRX R141 / R142 / R266

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

The University of Texas at Austin September 30, 2011

Interface Practices Subcommittee SCTE STANDARD SCTE Hard Line Pin Connector Return Loss

The Custom Interconnect Leader TM

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

GaAs MMIC Double Balanced Mixer

Installation and Operation Manual. for the. SM-6 Programmable Stereo Mixer

PERFORMANCE SPECIFICATION ELECTRON TUBES GENERAL SPECIFICATION FOR

Transcription:

METRIC MIL-DTL-38/22J 18 February 2015 SUPERSEDING MIL-DTL-38/22H 14 June 2013 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, DUMMY STOWAGE, SERIES III, METRIC This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-38. mm Inches 0.13.01 12.40.4 12.5.51 14.50.57 14.73.58 FIGURE 1. Dummy stowage receptacle, classes F, G, J, K, M, R, S, T, W, X and Z. AMSC N/A FSC 535

Dimensions size size code P ±.20 PP ±.20 R1 (see note 4) R2 (see note 5) A (see note 8) 5.4 (.216) 18.26 (.71) 15.0 (.54) A1 (see note 6) 5.4 (.216) 18.26 (.71) 15.0 (.54) A2 (see note 7) 5.4 (.216) 18.26 (.71) 15.0 (.54) 11 B 4.3 (.14) 20.62 (.812) 18.26 (.71) 13 C 4.3 (.14) 23.01 (.06) 20.62 (.812) 15 D 4.3 (.173) 24.61 (.6) 23.01 (.06) 17 E 4.3 (.14) 26.7 (1.062) 24.61 (.6) 1 F 4.3 (.14) 2.36 (1.156) 26.7 (1.062) 21 G 4.3 (.14) 31.75 (1.250) 2.36 (1.156) 23 H 3.1 (.154) 6.15 (.242) 34.3 (1.375) 31.75 (1.250) 25 J 3.1 (.154) 6.15 (.242) 38.10 (1.500) 34.3 (1.375) FIGURE 1. Dummy stowage receptacle, classes F, G, J, K, M, R, S, T, W, X and Z Continued. 2

Dimensions size size code S ±.3 V + 0.00-0.13 V + 1.4-0.0 W ±.3 W A (see note 8) 23.8 (.37) 3.65 (.144) 2.2 (.087) A1 (see note 6) 23.8 (.37) A2 (see note 7) 23.8 (.37) 11 B 26.2 (1.031) 13 C 28.6 (1.126) 15 D 31.0 (1.220) 17 E 33.3 (1.311) 1 F 36.5 (1.437) 21 G 3.7 (1.563) 20.07 (.70) 18.7 (.736) 3.2 (.126) 4.35 / 2. (.171 /.114) 23 H 42. (1.68) 20.07 (.70) 18.7 (.736) 3.2 (.126) 4.35 / 2. (.171 /.114) 25 J 46.0 (1.811) 20.07 (.70) 18.7 (.736) 3.2 (.126) 4.35 / 2. (.171 /.114) NOTES: 1. Dimensions are in millimeters. Inch equivalents are given for information only. 2. Flange is solid. 3. Dummy receptacles are used when unmated plugs must be protected. 4. Dimensions required for intermountability with front or rear mounting series I. 5. Dimensions required for intermountability with front mounting series II. 6. size code A1 is for use with size plug mating key polarizations C, E and N, only. 7. size code A2 is for use with size plug mating key polarizations A, B and D, only. 8. size code A (inactive for new design) is for use with legacy systems with size plug mating key polarizations A, B, C, D, E and N. FIGURE 1. Dummy stowage receptacle, classes F, G, J, K, M, R, S, T, W, X and Z Continued. 3

SHELL SIZE (SHELL SIZE CODE A, UNIVERSAL CONFIGURATION FOR MATING TO PLUGS WITH KEY POLARIZATIONS A, B, C, D, E AND N (INACTIVE FOR NEW DESIGN)) SHELL SIZE, SHELL SIZE CODE A FIGURE 2. Dummy stowage receptacle, keyway arrangements, classes F, G, J, K, M, R, T, S, W, X and Z (shell size ). 4

SHELL SIZE, SHELL SIZE CODE A1 FIGURE 2. Dummy stowage receptacle, keyway arrangements, classes F, G, J, K, M, R, T, S, W, X and Z (shell size ). 5

SHELL SIZE, SHELL SIZE CODE A2 NOTES: 1. Dimensions are in millimeters. 2. Inch equivalents are given for information only. FIGURE 2. Dummy stowage receptacle, keyway arrangements, classes F, G, J, K, M, R, T, S, W, X and Z (shell size ) - Continued. 6

SHELL SIZES 11, 13 AND 15 size size code A dia B dia 11 B 15.88/15.60 (.625/.614) 14.66/14.45 (.577/.56) 13 C 1.66/1.38 (.774/.763) 17.50/17.30 (.68/.681) 15 D 22.84/26 (.8/.888) 20.65/20.44 (.813/.805) NOTES: 1. Dimensions are in millimeters. 2. Inch equivalents are given for information only. FIGURE 3. Dummy stowage receptacle, keyway arrangement, classes F, G, J, K, M, R, S, T, W, X and Z (shell sizes 11, 13 and 15). 7

SHELL SIZES 17, 1, 21, 23 AND 25 size size code A dia B dia 17 E 26.01/25.73 (1.024/1.013) 23.85/23.64 (.3/.30) 1 F 28.63/28.40 (1.127/1.118) 26.55/26.31 (1.045/1.036) 21 G 31.85/31.57 (1.254/1.243) 2.70/2.4 (1.16/1.161) 23 H 35.03/34.75 (1.37/1.368) 32.85/32.66 (1.23/1.286) 25 J 38.20/37.2 (1.504/1.43) 36.00/35.84 (1.417/1.411) FIGURE 4. Dummy stowage receptacle, keyway arrangement, classes F, G, J, K, M, R, S, T, W, X and Z (shell sizes 17, 1, 21, 23 and 25). 8

REQUIREMENTS: Dimensions and configurations: See figures 1 thru 4. Interface dimensions shall conform to MIL-DTL-38, except as noted. This dummy stowage receptacle (DSR) mates with qualified plugs in accordance with MIL-DTL-38/26, MIL-DTL-38/2, MIL-DTL-38/30, and MIL-DTL-38/31. Air leakage: Testing shall be in accordance with EIA-364-02, except the minimum period of measurement shall be 10 seconds. The air leakage rate shall be no greater than 1 atmospheric cubic inch per hour (4.55 X 10-3 cm 3 /s) Stowage receptacles shall be mated to connectors having either contacts or inserts removed so that a pressure of 10 lbft/in 2 (.703 Kg/cm 2 ) can be applied against the insides of the stowage receptacles. Qualification (all classes): Qualification shall be in accordance with MIL-DTL-38, conducted on two samples of each shell size, except only the following sequence of tests shall be required: Examination of product Coupling torque Dynamic salt spray (corrosion) Air leakage (see requirement) Visual and mechanical Qualification (classes J and M only): Qualification shall be in accordance with MIL-DTL-38, except that in addition to the test sequence specified for all classes above, the following tests shall be required: Temperature cycling Hydrolytic stability Group A sampling inspection. Sampling for group A inspection shall be as specified in table I. TABLE I. Group A sampling plan. Lot size Sampling size 1 to 13 100 percent 14 to 150 13 units 151 to 280 20 units 281 to 500 2 units 501 to 1,200 34 units 1,201 to 3,200 42 units 3,201 and up 54 units

Part or Identifying Number (PIN) example: MIL-DTL-38/22J D38/ 22 B W DoD number prefix Specification sheet number size code (for shell size codes A, A1 and A2, see note) Class NOTE: size codes A, A1 and A2 for shell size only: size code A is a universal configuration for use with plugs with mating key polarizations A, B, C, D, E and N. size code A1 is for use with plugs with mating key polarizations C, E or N. size code A2 is for use with plugs with mating key polarizations A, B or D. Class F is not for Navy use. Class F is inactive for use in Air Force new design. size code A (shell size ) is inactive for new design. Use shell size codes A1 or A2 for new design. NOTE: The term PIN is equivalent to the term (part number, identification number, and type designator) which was previously used in this specification. Application note: 1. size, shell size code A (universal configuration), is not recommended for blind mate applications due to the possibility for misalignment between the DSR keyways and the plug keys. Misalignment can potentially damage plug EMI bands. Change effectivity. Unless otherwise specified by the preparing activity and/or the qualifying activity, all changes from the previous revision of this specification sheet shall become effective within 0 days of the date of publication of the latest revision. If unable to implement changes within the 0 day time period, the manufacturer or value added distributor shall notify the qualifying activity. The qualifying activity shall determine if an extension may be granted. Disposition of stock. Unless otherwise specified by the qualifying activity and coordinated with the preparing activity, qualified manufacturers and their selling agents or distributors may continue to ship stowage receptacles which were manufactured in accordance with the previous revision of this specification sheet for a period of 18 months from the date of the latest revision, provided that form, fit and function are not affected. Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. 10

Referenced documents. In addition to MIL-DTL-38, this document references the following: MIL-DTL-38/26 MIL-DTL-38/2 MIL-DTL-38/30 MIL-DTL-38/31 EIA-364-02 CONCLUDING MATERIAL Custodians: Preparing activity: Army - CR DLA - CC Navy - AS Air Force 85 (Project 535-2015-031) DLA - CC Review activities: Army - AR, MI Navy - EC, MC, OS Air Force - 1, NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.dla.mil. 11