Explosion Proof Audible Signal db(a) Series YA60

Similar documents
Explosion Proof Audible Signal db(a) Series YA60

Pendant Light Fitting IEC Series 6470/2

Signalling Devices. 516 Signalling Devices KP00 III en Preferred products in stock or available at short notice

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Pendant Light Fittings Series 6050

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Circuit-Breakers for Motor Protection Series 8523/8

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

8 Installation Equipment

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

TYPE APPROVAL CERTIFICATE

EXPlora. Introduction

Motor Protection Circuit Breaker Series 8146/5-V27

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Model JDF Field Indicator

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

7 Lighting Technology

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

PMG. Vibration Energy Harvesters

EXLUX ECOLUX 6480 Series

TECHNICAL DATA. Type. TMC2X Design Specification. Category B ATEX Certificate. Code of Protection. IECEx SIR X Code of Protection

Flow Measurement SITRANS F M

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

EXLUX ECOLUX C-LUX 6480 Series

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Horn loudspeaker, Ex proof, short/long flare

I Ex-protected connectors exlink I

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

ExCam XPT Q6055. User Manual

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Parts List _2.1. Flygt /.190

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

XML LED X M L L E D. Explosionproof Linear LED Lighting

TYPE APPROVAL CERTIFICATE

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Parts List _2.1. Flygt /.890

PRE Series 16 Amp Plugs and Sockets Increased Safety

Level Measurement Point level measurement - RF Capacitance switches

Installation instructions Cable transit device Roxtec RS ES Ex

Inductive sensor With analog output BI15-M30-LI-EXI

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Datasheet EC-750 Ex DOME Camera

Nessie Coils for VDH and VDHT valves

Level Measurement Point level measurement RF Capacitance switches

Operating instructions

Inductive sensor BI1.5-EG08K-Y1

PROPORTIONAL VALVES Sentronic plus

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor NI3-EG08K-Y1-H1341

Pressure transmitter For applications in hazardous areas Model IS-3

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

Level Measurement Continuous level measurement - Radar transmitters

RMA 3000 Remote Meter Assemblies Specifications

General Specifications

Installation instructions Roxtec RS ES Ex

ENCODERS FOR OIL & GAS

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

GENERAL CATALOGUE EN013 E C

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.

Champ-Pak Wall Pack Luminares

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Level Measurement Continuous level measurement Radar transmitters

D Clear communication even under extreme conditions DRÄGER COMMUNICATION SYSTEMS

Inductive sensor NI10-M18-Y1X-H1141

Coils for solenoid valves

Guided Radar (TDR) Level Transmitter for storage and process applications

Modular Lube Lubrication Systems System Controls

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Level Measurement Continuous level measurement - Capacitance transmitters

Installation instructions Ex frames

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Absolute Encoders Multiturn

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Safety Light Curtains GuardShield

ATEX UHF RFID Long Range Reader with Integrated Antenna Zone 2 / 22 ISO

RSCC. Load cells. Special features. Data sheet

TFRH Hygienic RTD temperature sensor. CombiTemp TM

OPTIFLEX 2200 C/F Technical Datasheet

Process Transmitter RMA 422

82540/ /2-way diaphragm valves

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Flow Measurement SITRANS F M

Optical Signal Devices. Free-standing Beacons

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Transcription:

> Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable tones meeting international regulations > Sound selection via DIL switch > Telephone initiate option available www.stahl.de 14718E00 Yodalex range Omnidirectional audible signal designed for use in hazardous or harsh environments. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x x x For use in x x x x For use in x x x x x x WebCode YA60A Signalling Devices /1

Explosion Protection Global (IECEx) Europe (ATEX) +H2 IECEx BAS 05.0087X IECEx BAS 05.0086X +H2, IEC 60079-0: 2011 / IEC 60079-1: 2007-04 / IEC 60079-31: 2008 +H2 Ex d +H2 T4 Gb (Ta = -20 +60 C) Ex tb IIIC T135 C Db IP 66 (Ta = -20 +60 C) Ex d +H2 T6 Gb (Ta = -20 +40 C) Ex tb IIIC T85 C Db IP 66 (Ta = -20 +40 C) Ex d T4 Gb (Ta = -35 +60 C) Ex tb IIIC T135 C Db IP 66 (Ta = -35 +60 C) Ex d T6 Gb (Ta = -35 +40 C) Ex tb IIIC T85 C Db IP 66 (Ta = -35 +40 C) +H2 Baseefa02ATEX0222X Baseefa02ATEX0212X +H2, EN 60079-0: 2009 / EN 60079-1: 2007 / EN 60079-31: 2009 +H2 EII 2 GD Ex d +H2 T4 Gb (Ta = -20 +60 C) EII 2 GD Ex tb IIIC T135 C Db IP 66 (Ta = -20 +60 C) EII 2 GD Ex d +H2 T6 Gb (Ta = -20 +40 C) EII 2 GD Ex tb IIIC T85 C Db IP 66 (Ta = -20 +40 C) EII 2 GD Ex d T4 Gb (Ta = -35 +60 C) EII 2 GD Ex tb IIIC T135 C Db IP 66 (Ta = -35 +60 C) EII 2 GD Ex d T6 Gb (Ta = -35 +40 C) EII 2 GD Ex tb IIIC T85 C Db IP 66 (Ta = -35 +40 C) USA and Canada (UL variants) +H2, E161818 +H2, USL: UL 60079-0 / UL 60079-1 / UL 1203 / UL 1638 CNL: A C22.2 No. 30-M1986 / A C22.2 No. 25-M1966 / A E60079-0-7 / A E60079-1 Russia (GOST R) Certifications and certificates Certificates +H2 Class I, Div. 1, Groups B, C and D Class I, Div. 2, Groups B, C and D Class 1 Zone 1 AEx d + H 2 T4 Class 1 Zone 1 Ex d + H 2 T4 Operating temperature -25... +66 C Audible signal appliance fire alarm service private mode Class I, Div. 1, Groups B, C and D Class I, Div. 2, Groups B, C and D Class 1 Zone 1 AEx d T4 Class 1 Zone 1 Ex d T4 Operating temperature -35... +66 ºC Audible signal appliance fire alarm service private mode Marking and certification based on and line with the ATEX product. IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (GOST K), Russia (GOST R), Taiwan (ITRI), USA (UL) /2 Signalling Devices

Technical Data Electrical data Rated operational voltage Rated operational current 24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters + or -10 % 24 V DC 350 ma 48 V DC 300 ma 115 V AC 110 ma 230 V AC 55 ma Acoustic data Volume 110 db (A) / 1 m Sound selection via DIL-switch Ambient conditions Operating temperature version range Europe T4-35... + 60 C T6-35... + 40 C + H 2 Europe T4-20... + 60 C T6-20... + 40 C USA T4-35... + 66 C + H 2 USA T4-25... + 66 C Mechanical data Material Enclosure aluminium, seawater resistant Horn ABS, flame retardant Fixings stainless steel Mounting bracket mild steel with black polyester powder coat finish; supplied as standard Product label metalised polyester UL certified variants supplied with stainless steel label Degree of protection IP66 IEC 60529 NEMA 4X UL 50 Cable entries 2 cable entries, equipped with stopping plug (1x) and dust cap (1x) UL devices: equipped with M20 / 1/2 adaptors (2x) Signalling Devices /3

Selection Table Version Group Rated operational voltage Order number Art. no. Weight kg + H 2 24 V DC YA60/C/D/EU 205191 5.400 ATEX certification, 115 V AC YA60/C/L/EU 205199 5.400 230 V AC YA60/C/N/EU 205200 5.400 UL certification, IECEx certification, GOST R certification, Selection Table Version devices acc. to specification B, C, D 24 V DC YA60/B/D/UL 205202 5.400 115 V AC YA60/B/L/UL 205204 5.400 230 V AC YA60/B/N/UL 207054 5.400 + H 2 24 V DC YA60/C/D/IN 205197 5.400 115 V AC YA60/C/L/IN 212393 5.400 230 V AC YA60/C/N/IN 212394 5.400 + H 2 24 V DC YA60/C/D/RU 205198 5.400 115 V AC YA60/C/L/RU 212395 5.400 230 V AC YA60/C/N/RU 212396 5.400 Variations in gas group, flash energy, voltage and lens colour are available, please use the Selection Table Variations Type code: please fill in fields Gas group EU, IN and RU units B + H2 UL units C, D gas groups C Rated Operational Voltage Certification B gas groups 24 V DC D 48 V DC F 115 V AC L 230 V AC N ATEX UL Additions IECEx GOST-R activation telephone initiate TI additional approvals Duty + tag labels are available on request. Please contact your local sales office for more details. C B EU UL IN RU L Order Number YA60 / _ / _ / _ / _ /4 Signalling Devices

Accessories and Spare Parts Designation Figure Description Group Order number Art. no. WebCode Cable gland Compound Barrier Cable Glands + H 2 8163/2-20- 138888 8163J and IIC PXSS2K-M20 Unarmoured Cables 14976E00 14742E00 Compound Barrier Cable Glands Armoured Cables Cable Glands Ex d and Ex e for Unarmoured Cables + H 2 and IIC 8163/2-20- PX2K-M20 8163/2-20- A2F-M20 138875 8163I 138772 8163A 14977E00 14978E00 Triton CDS Cable Glands Armoured Cables Approvals of cable entries have to be observed. 8163/2-20- T3CDS-M20 138902 8163K Accessories and Spare Parts Designation Figure Description Art. no. Mounting bracket stainless steel bracket fixing kit accessories 210794 Replacement PCB assembly 15795E00 24 V DC 222969 16672E00 115... 230 V AC 209515 16675E00 Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 75 mm / 3 M8 288 mm / 11.3 145 mm / 5.7 13975E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Signalling Devices /5