MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Similar documents
for ACCUMEASURE Capacitance Probes Standard and Custom Capacitance Probes Available A worldwide leader in precision measurement solutions

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

OPTICAL POWER METER WITH SMART DETECTOR HEAD

2 MHz Lock-In Amplifier

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Flat-Bed Module Recorders

SCALE & WEIGHT DISPLAYS

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Dynatel Advanced Cable Locator 2250

SPECIFICATION NO NOTE

ENC - LKE51 - L I B

Electrical connection

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

3500/42E Vibration Monitor

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

Sensopress LCD Special English

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

ScopeMeter 190 Series Specifications

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

SPECIFICATION NO Model 207 Automatic GTAW Welding System

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

1/3 RACK-MOUNTED BLOCK CONVERTERS

1900/25 Vibration Monitor

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

More Precision. capancdt // Capacitive displacement sensors and systems

MULTIBAND 1/3 RACK-MOUNTED

Industrial Diode Laser (IDL) System IDL Series

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Microwave Counter, Power Meter and DVM in One Portable Package

R&S RT-Zxx High-Bandwidth Probes Specifications

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

More Precision. capancdt // Capacitive displacement sensors and systems

SMT Encoder for High Performance, High Volume Designs Small Size High Resolution Low Cost ChipEncoder Reflective Surface Mount Encoder Features

Wall-/Pipe-Mount Level Indicator

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

HS-509 VIBRATION TRIP MODULE

TABLE OF CONTENTS. Instructions:

800 Displaying Series Flowmeter

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

More Precision. confocaldt // Confocal chromatic measuring system

Agilent 5345A Universal Counter, 500 MHz

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Label Applicator HERMA 400

Full-featured CW Microwave Counters for Field, Factory or Lab

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Subj: General MTI2000 and Piezo Task Setup and Operation. High-Voltage Displacement Meter (HDVM) Configuration.

Guided Wave Radar Level Meter

Linear encoders without bearings incremental System for linear motion feedback

Signal Stability Analyser

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

More Precision. confocaldt // Confocal chromatic measuring system

Process Transmitter RMA 422

The Versatility in Vibration Measurement Datasheet

Modular Lube Lubrication Systems System Controls

MAP Optical Power Meter Module (mopm-b1)

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Measuring Small. The technique of measuring very small Lateral Tape Motion (LTM) Gary Collins, P.E.

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

OTS-300 Express Series Power Meters/Sources and Testers

The measurements are stored in non-volatile memory, which retains data even when the power down.

R&S RT-Zxx High-Voltage and Current Probes Specifications

More Precision. capancdt // Capacitive displacement sensors and systems

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

AF-300 E11 Adjustable Frequency Drive

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

J R Sky, Inc. tel: fax:

FLOMAT Electromagnetic Insertion Flowmeter

SonoruS Audio. ATR10 Analog Tape Reproducer. Operating Manual

Video Digital Optical Converter

WaveDriver 20 Potentiostat/Galvanostat System

Advanced Test Equipment Rentals ATEC (2832)

2016 RIGOL TECHNOLOGIES, INC.

In-process inspection: Inspector technology and concept

2 MHz Lock-In Amplifier

Analog Dual-Standard Waveform Monitor

Model KT 115 Cooling incubators with thermoelectric cooling

JD725A Cable and Antenna Analyzer - Dual Port

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Fluke 279 FC True-rms Thermal Multimeter

WVR500 Waveform/Vector Monitor

Absolute Rotary Encoder E6CP

Transcription:

A worldwide leader in precision measurement solutions MTI-2100 FOTONIC SENSOR High resolution, non-contact measurement of vibration and displacement

MTI-2100 Fotonic TM Sensor Unmatched Resolution and Frequency Response in Non-Contact, Fiber-Optic Measurement The MTI-2100 features advanced fiber-optic and electronic technologies for precise of displacement, position and vibration. It sets new performance standards with resolution as low as 0.01 µin. (2. angstroms) and frequency response from direct-coupled (dc) to 00 khz. The MTI-2100 s modular design has the flexibility to be tailored to specific requirements through the use of a wide range of interchangeable and custom fiber-optic probes. These probes are immune to electromagnetic interference (EMI) and operate on almost any type of surface: metallic, composite, plastic, glass, ceramic or liquid. Dual-channel capability enables the user to make simultaneous, essential for studies of structure dynamics and modal analysis. For increased versatility, all probe modules offer the advantage of two distinct operating ranges: one for high resolution and the other for greater measurement range. Application Solutions for R&D, Quality and Process Control Vibration Modal Analysis Micro-Positioning Run-out Displacement Structural Dynamics Defect Detection Resonance Analysis Reciprocating Motion Speed Sensing Surface Finish Analysis Edge Detection Liquid Surface Motion Profiling Displacement and Timing of Fuel Injectors and Solenoids Bearing Defect Analysis Modal Analysis of Disk Drive Suspensions

System Features & Advantages Single or dual probe module operation allows two simultaneous Backlit LCD display shows output in volts or engineering units, indicates measurement parameters and calibration setup LED position indicator shows at-a-glance probe position Over/under range alarms indicate outof-range conditions Built-in peak-to-peak detector ideal for vibration amplitude selector provides two distinct measurement 7-Position ranges for each low-pass filter probe module Auto zero selector resets display/output to zero for relative 7-Position low-pass filter 3-Position high-pass filter Selectable English/ metric/voltage units Automatic calibration at the push of a button High Resolution Module resolves to 0.01 µin. (2. angstroms) Interchangeable Probe Modules for application flexibility Bent Tip Probes for hard-to-reach areas Reflective Compensated Modules eliminate reflection errors Unique Edge Probe Design for lateral motion High Frequency Measurements to 00 khz Vibration of Ultrasonic Horns Tape and Web Edge Positioning Run-out of Computer Disk Drives

Standard Fotonic Probe Operating Principle Each MTI-2100 Fotonic probe contains a set of light transmitting and light receiving fibers, which can be arranged in three different configurations (random, hemispherical or concentric). A tungsten halogen lamp feeds light down the transmit fibers, where it exits the probe tip and hits the target. Light that is reflected from the target is captured by the receive fibers and transmitted to the MTI-2100. The light intensity is monitored, which is proportional to the distance between the probe tip and the target being measured. At contact, no light is exiting or received by the fibers, giving an output signal of zero. As the probe-to-target distance increases, increasing amounts of light are proportionally captured by the receive fibers. The result is a very sensitive, linear output response ( 1) from the MTI-2100. As the distance is further increased, the amount of light received approaches the maximum or optical peak. After the optical peak is reached, a continued increase in probe gap will proportionally reduce the amount of light received. This results in a sensitive, linear output response ( 2) with a large measurement range and standoff distance. Output Voltage 10 0 1 Standoff 1 Fiber Distribution Optical Peak 2 Target Displacement 2 Standoff Random (R) Hemispherical (H) Concentric (CTI) Receiving Fiber Transmitting Fiber Standard Fotonic Probe Specifications Probe Module Model No. MTI-2020R MTI-2032R MTI-2047R MTI-2062R MTI-2062H MTI-212R MTI-212CTI MTI-212H MTI-2032RX Probe Tip Diameter in. (mm) Meter Resolution 2, 9 µin. (µm) Maximum Output Cable Frequency Signal Length Response Noise in. (mm) 1 Total Active (-3 db) khz mv p-p 1 2 0.020 10 0.032 10 (0.813) 0.047 (1.194) 0.063 (1.600) 0.063 (1.600) 0.12 (3.17) 0.12 (3.17) 0.12 (3.17) 0.032 (0.813) 0.007 (0.178) 0.019 (0.483) 0.027 (0.686) 0.047 (1.194) 0.047 (1.194) 0.090 (2.286) 0.090 (2.286) 0.090 (2.286) 0.019 (0.483) 120 30 120 20 130 10 10 10 190 3 10 3 10 3 100 30 () () () X1 () () () () X10 0.1 (0.001) 3 ( ) µin. µm mv mv 0.6 (0.016) 0.74 (0.019) 0.80 (0.020) (0.02) (0.02) 7.0 (0.178) 13.0 (0.330) 0.20 (0.00) 1 Characteristics 3, 4 4.0 (0.102) 6.0 (0.12) 6.0 (0.12) 70.0 (1.778) 1 Characteristics 1.4 (0.036) Standoff 3 7.0 (0.178) 0.0 (1.270) 1. (0.038) 3 µin. µm mv mv 3.0 (0.076) 8.0 (0.203) 1 (0.381) 2 Characteristics ( ) 40.0 (16) 0.02 (0.000) 3, 4 12.0 (0.30) 29.0 (0.737) 40.0 (16) 60.0 (1.24) 7 (1.90) 140.0 (3.6) 140.0 (3.6) 17 (4.44) 2 Characteristics 0.4 (0.010) Standoff 3 3 (0.889) 44.0 (1.118) 70.0 (1.778) 10.0 (3.810) 1 (3.048) 2 (.88) 300.0 (7.620) 1.0 (0.038) Optical Peak Mid-point 6, 7 8 12.0 (0.30) 18.0 (0.47) 26.0 (0.660) 100.0 (2.0) 32.0 (0.813) 100.0 (2.0) 180.0 (4.72) 9.0 (0.229) 14.0 (0.36) 14.0 (0.36) 0.0 (1.270) 1.0 (0.038) 1. When measuring to a 2 µin. AA electroformed, GAR surface-finish comparator block. Noise given is with low pass adjustable filter set at wide band. Noise decreases as lower filter settings are selected. 2. The analog output resolution is a product of the sensitivity and the noise. 3. Nominal value ± 10%. 4. For approximate ± 1% linear range, multiply by 0.7.. Nominal value ± 10%. 6. Optimal standoff for reflectivity/surface finish. 7. Nominal value ± 1%. 8. Displacement range producing % change from peak output when making reflectivity/surface finish. 9. Highest possible meter resolution shown for intrinsic English and intrinsic metric engineering units. Probe module s intrinsic (English or metric) engineering units must be specified at the time probe module is ordered. Alternate engineering units selected via the front panel UNITS button offer reduced meter resolution. 10. MTI-2020R and MTI-2032R probe modules use a 0.062" diameter sleeve starting 0.20" (6.3 mm) back from the probe tip.

Reflectance Compensated Fotonic Probe MTI also offers a Fotonic probe design that automatically compensates for large changes in reflectivity of the target being measured. This unique design makes it possible to monitor targets over a dynamic reflectance range of 100:1, while maintaining high resolution and accuracy. The probe consists of three integrated glass fiber bundles. One bundle transmits light while the other two receive light, with different response characteristics. The probe module s electronics use the difference between the two receive bundles to compensate for reflectivity changes and provide a linear response proportional to probe gap. This concept allows the MTI-2100 to be used in applications where the target is translating or rotating. Fiber Distribution 0.12 in. Receiving Fiber 0.030 in. Transmitting Fiber 0.041 in. Output Voltage 10 0 Probe Dimensions in. 0.0 in. Target Displacement 1.2 in. 0.197 in. Reflectance Compensated Fotonic Probe Specifications Probe Module Model No. Probe Tip Diameter in. (mm) Meter Resolution Maximum Output 1 µin. (µm) 1 Characteristics 2 2 Characteristics 2 Cable Frequency Signal Length Response Noise Total Active in. (mm) 1 2 3 Standoff 3 (-3 db) khz mv p-p µin. mils mils µm mm mv mv 200RC 0.200 (80) 0.12 x 0.030 (3.17 x 0.762) 100 60 10 (1) 16 100 100 0.406 2.0 2.0 1. The analog output resolution is a product of the sensitivity and the noise. 2. Nominal value ± 10%. 3. For approximate ± 1% linear range, multiply by 0.7. Standoff mm Fotonic Edge Probe The Fotonic Edge probe is a specially designed sensor used to determine displacement and position of thin objects. The high frequency response obtained makes it ideal for dynamic of computer drive disks, magnetic tapes, ultrasonic tools and production line applications. Each sensor consists of a transmit and receive fiber-optic bundle located opposite each other. Light is directed past the edge of the target being measured to the receive fiber-optic bundle. As the target moves between the probes, the amount of light received fluctuates. The MTI-2100 monitors this fluctuation and precisely converts it to a target position. This highly sensitive design provides a larger probe standoff and can resolve to 0.1 µin. (2. nanometers). Prism Probe Configuration Prism Transmit Target Receive Output Voltage 10 0 Bent Tip Probe Configuration Transmit Receive Target Displacement Target Fotonic Edge Probe Specifications Probe Module Model No. Probe Tip Diameter in. (mm) Meter Resolution Maximum Cable Output 1, 4 µin. (µm) 1 Characteristics 2 2 Characteristics 2 Frequency Signal Length Response Noise Total Active in. (mm) 1 2 3 Standoff 3 Standoff (-3 db) khz mv p-p µin. µm µin. µm mv ( mv ) mv ( mv ) MTI-2047E 0.047 (1.194) 0.027 (0.686) 100 13 0.7 (0.019) N/A 0.10 (0.002) 2.0 (0.01) N/A MTI-2062E 0.063 (1.600) 0.047 (1.194) 100 18 1.20 (0.031) 7. (0.191) N/A 0.16 (0.004) 2.4 (0.061) N/A 1. The analog output resolution is a product of the sensitivity and the noise. 2. Nominal value ± 10%. 3. For approximate ± 1% linear range, multiply by 0.7. 4. Highest possible meter resolution shown for intrinsic English and intrinsic metric engineering units. Probe module s intrinsic (English or metric) engineering units must be specified at the time probe module is ordered. Alternate engineering units selected via the front panel UNITS button offer reduced meter resolution.. Actual frequency response and noise levels are dependent upon probe tip separation.

General Specifications Power Requirements 100 to 240 Vac, 0/60 Hz. Maximum Power Dissipation: 3 W. Fuse: 1.2 A, time delay, 20 V, x 20 mm. Dimensions Weight.6 in. (14.2 cm) H. 10 lb. (4. kg). 14.1 in. (3.8 cm) W. 10. in. (26.7 cm) D. Environmental Requirements Instrument Operating Temperature: 0 F to 110 F (10 C to 43 C) non-condensing. Instrument Storage : 0 F to 10 F (-18 C to 6 C) non-condensing. Display Meter: graphic LCD, white on blue background, 100 Hz response, updates 3 times per second. Bar Graph: 20-element green LED (0. Volt step size), 10 Hz response. Displacement Measurements Output Signal: 0 to 10 Vdc, 1 Ω output impedance. Stability at 12 hrs., ± 2 F (± 1 C): drift less than % of full scale. Stability at 60 F to 9 F (16 C to 3 C): drift less than 2.0% of full scale. Vibration Measurements Output Signal: 0 to 10 Vdc full-scale range, 1 Ω output impedance. Accuracy: within % for peak-to-peak readings from 1 Hz to 10 khz (probe-dependent). System Noise: dependent upon probe type and surface reflectivity. High/Low Pass Filters High Pass Filter: DC, 20 Hz, 200 Hz front-panel selectable 4-pole Butterworth response (-3 db at value selected). Low Pass Filter: 100 Hz, 1 khz, 10 khz, 20 khz, 0 khz, 100 khz and wide band, 1-pole response (-3 db at 1.2 X value selected). RS-232 Data Output Displacement Data Accuracy: within 1% for signals from dc to 100 Hz. Vibration Data Accuracy: within 1% for peak-to-peak displacements from 1 Hz to the maximum frequency response of probe module in use. Standard Probe Specifications Temperature : -67 F to 10 F (- C to 6 C). Operating Pressure : vacuum of 29 in. Hg to 00 psig. (MTII does not guarantee leak-proof operation) Tip Length: 3 in. (76.2 mm). Cable Length: in. (1,372 mm) standard. in. Options 0.0 in. Bent Probe Tips: consult factory for minimum bend radius. High-Pressure/High-Vacuum Probes. Standard High Temperature Probes: from -67 F to 900 F (- C to 482 C). Accessories 0.2 in. Ø 3.0 in. Optical Probe Extenders: Precision lens systems that permit operation of standard fiber-optic probes at a greater standoff distance with no loss of probe sensitivity or frequency response. FS-3 Probe Mounting Fixture: Used to position the probe over the target being measured. Consists of a magnetic base, two extension arms, probe mounting clamp for diameters up to 0.12 in. (3.2 mm) and micrometer for fine position adjustment. Contact MTI Instruments for other custom probe temperature ranges. MTI Instruments has been at the forefront of non-contact measurement technology for nearly 0 years. Our application engineers will be happy to work with you to determine the best solution for your measurement needs. MTI Instruments, Inc. 32 Washington Avenue Extension Albany, NY 1220 PH: +1-18-218-20 OR USA TOLL FREE: 1-800-342-2203 FX: +1-18-218-206 EMAIL: sales@mtiinstruments.com www.mtiinstruments.com For information on other non-contact products or custom solutions from MTI Instruments, contact us at 1-800-342-2203 or +1-18-218-20. A subsidiary of Mechanical Technology, Inc. (NASDAQ:MKTY) 300/6 BLC MT1304 6