specification hyperion colorimeter

Similar documents
specification hyperion colorimeter

specification MSE series MSE and MSE+ colorimeter

specification display applications cronus spectrometer & colorimeter

technical note flicker measurement display & lighting measurement

NEW. Display Color Analyzer CA-410. Broad measurement support for today's ever-evolving displays CA-310 successor with major improvements

Measurement of Microdisplays at NPL

DISPLAY COLOR ANALYZER MODEL 7123 MODEL Display Color Analyzer. Key Features:

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

OPTICAL POWER METER WITH SMART DETECTOR HEAD

LED TEST. ATX Hardware GmbH West and Feasa Enterprises Limited a long-standing partnership. SPECIALIST FIXTURE SOLUTIONS

Flash Single Color Datasheet

Description. Kingbright

Display Color Analyzer

Description. Kingbright

SURFACE MOUNT DISPLAY. Description. Features. Package Dimensions& Internal Circuit Diagram. Green. Part Number: ACSA02-41SGWA-F01. Super Bright Green

1.0X0.5X0.2mm (0402)SMD CHIP LED LAMP. Features. Descriptions. Package Dimensions

1.6X1.25mm BI-COLOR SMD CHIP LED LAMP. Description. Features. Package Dimensions

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

SURFACE MOUNT DISPLAY. Features. Descriptions. Package Dimensions& Internal Circuit Diagram

1.6x0.6mm RIGHT ANGLE SMD CHIP LED LAMP. Features. Description. Package Dimensions. Part Number: APA1606SGC. Super Bright Green

LCD MODULE SPECIFICATION

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Description. Kingbright

Cree XLamp 4550 LEDs BENEFITS

Description. Kingbright

YJ-BC-3030-G01 High CRI LED

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

Home Cinema LCD Projector with 4K Enhancement and HDR

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

YJ-VTC-5730-G02 High CRI LED

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

127mm (5.0INCH) SEVEN SEGMENT DISPLAY. Features. Description. Package Dimensions& Internal Circuit Diagram

Transmitter optics with 9x white light LED (optics cover made of glass)

YJ-BC-2835L-G02 High CRI LED

Scanning For Photonics Applications

IFM65UG OPS-COMPLIANT 16/7 400 NITS ULTRA HD INTERACTIVE FLAT PANEL DISPLAY

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

DPD80 Visible Datasheet

27" 10-point multi-touch interactive display

Full-featured CW Microwave Counters for Field, Factory or Lab

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

AA3528VR4AS-W2 3.5 x 2.8 mm Surface Mount LED Lamp

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

YJ-VTC-2835-G01 High CRI LED

DPD80 Infrared Datasheet

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

CAEN Tools for Discovery

OpticalProducts. Illuminating Your Network. Testing the World s Networks

SPECTRO Series SPECTRO /0 -MSM-ANA-VIS. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p. 8-9) Product name:

Showcasing Brilliant Photos with Superb High- Definition Clarity

EdiPower II CAC Series Datasheet

Photometric Test Report

LUT Luminescence scanners: Seeing what no-one else can

interactive displays

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS


USB Smart Power Sensor

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

EdiPower II HM Series Datasheet

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

PLCC Series EMC 3030 Single color

EdiPower II HM Series (PAR) Datasheet

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

SURFACE MOUNT DISPLAY. Descriptions. Features. Package Dimensions& Internal Circuit Diagram

CBF500 High resolution Streak camera

HDMI Extender via Single SC Fiber Support 3D/4K2K Up to 200m in one Single-mode Fiber

Fluorescence Spectrophotometer

43 Professional Monitors

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

WP36BHD T-1 (3mm) Blinking LED Lamp

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

UniVision Engineering Limited Modpark Parking System Technical Description. Automatic Vehicle Access Control by Video Identification/

DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

LAUREL ELECTRONICS, INC.

LMG EG01B - 17"

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

S195AVGC-2BM 1.6x0.8mm, Red & Yellow Green LED Surface Mount Bi-Color Chip LED Indicator

Data Sheet. HDSP-573x Seven Segment Displays for High Light Ambient Conditions. Description. Features

WQHD 2560 x 1440 Resolution 99% srgb color coverage and 87% AdobeRGB color coverage provide richer and more precise

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

The ViewSonic VX2778-smhd is a 27 WQHD LCD monitor with 2560x1440 resolution and SuperClear IPS Panel technology. This monitor offers best-in-class

IH49V01D. 49" IPTV Hotel Series

USB Smart Power Sensor

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA

PicoScope 6407 Digitizer

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

SPECTRO Series SPECTRO-3-5-DIF-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

HDMI Extender Via One MPO Fiber MPO Connector Extends HDMI Link Up To 200 Meters

IH43W01E. 43" IPTV Hotel Series

DRAFT. Proposal to modify International Standard IEC

medlab One Channel ECG OEM Module EG 01000

Transcription:

specification hyperion colorimeter

Contents Hyperion... 3 2 Highlights... 3 3 General specifications... 4 4 Typical spectral sensitivity... 4 0mm measurement specifications... 6 0mm improved measurement specifications... 6 7 0mm measurement data... 7 8 0mm improved measurement data... 9 9 Hyperion 0mm dimensions... 0 Hyperion 0mm improved dimensions... 2 Hyperion M8 fibre dimensions... 3 2

Hyperion The Hyperion colorimeter offers a unique combination of high speed and accurate colour measurement capabilities packed in a robust package. In comparison to its predecessors, the Hyperion has a significant improvement on filter characteristics and an incredible speed upgrade. It is actually four times faster than previous models making accurate colour measurements possible at cd/m 2 in only 0ms. The Hyperion colorimeter is available with a 0mm spot size. A fiber version is also available with several optics, custom optics can be applied on request. Added to the filter characteristics the high sensitivity, ultralow noise electronics and a huge dynamic range make it the ideal device for display measurements even at low levels. 2 Highlights Highly accurate colour measurement according to human eye (CIE93) Fast colour measurement even at low luminance level Flicker luminance (Y) function: 2000 samples/second Autorange function Powerful MCU enables internal JEITA flicker calculation Mechanical shutter USBMTC standard compliant Windows, Linux and MAC OSX compatible Directly supported in Labview, LabWindows, Visual Studio via VISA library 3

3 General specifications Interfaces USB 2.0 RS 232 Trigger in & out USBMTC compliant, SCPI command set, high speed device For PC and embedded purposes, using same command set as USB V compliant 4 Typical spectral sensitivity Power ratings Min voltage Typical voltage Max voltage Max current USB power 4.7V.00V.2V 300mA 9V power 8.7V 9.00V 9.2V 300mA Measurement system Photo detector Spectral response Measurement parameters Size (HxWxD) Weight Mounting 3 silicon photo diode using XYZ interference filter Approximates CIE 93 colour matching functions XYZ, Yxy, Yuv, correlated colour temperature (CCT), dominant wavelength DWL, Flicker, Response time 3x70x47 mm (without lens system) 670 gram 2 M3 threat holes spread over four sides 4

0mm measurement specifications Measurement system Optical system Acceptance angle º (+/ 2.6) Measurement spot size 4 mm at 0 mm distance 9 mm at mm distance Flicker measurement speed (sample mode) Luminance 2000 samples / second, XYZ 2000 samples / second Correct detected frequency of at least Hz Colour measurement speed Colour 22 ms or higher, depending on luminance level (including communication) 0 cd/m² with DC level light at 6 ms. PWM requires longer integration (multiple frames) Sample mode signal frequency response Parameter a F 3db Gain DC 00 Hz Gain 2 DC 00 Hz Gain 3 DC 00 Hz Colorimeter specification Parameter Range Accuracy Repeatability Resolution 6 bit for X, Y and Z >80 db without averaging Luminance (Y) 0.00 cd/m² 20,000 cd/m² +/2% of measured value, measured at white image Y +/ 0.% at 0. cd/m² ¹ integration time between of LCD display, Luminance of app. 0 cd/m², Y +/ 0.2% at cd/m² ¹ 0.ms s x=00 y= 2 Y +/ 0.% at cd/m² ¹ Y +/ 0.% at 0 cd/m² ¹ Chromaticity (x,y) +/ 0.00 after calibration, measured at white image of LCD display, Luminance of app. 0 cd/m², x=00 y= 2 x,y +/ 0.00 for Y at 0. cd/m² ¹ x,y +/ 0.0002 for Y at cd/m² ¹ x,y +/ 0.0002 for Y at cd/m² ¹ x,y +/ 0.0002 for Y at 0 cd/m² ¹ Measurement speed samples / s for Y at 0. cd/m² ¹ 020 samples / s for Y at cd/m² ¹ samples / s for Y at cd/m² ¹ samples / s for Y at 0 cd/m² ¹ Flicker (contrast method) cd/m² or higher +/ % flicker frequency 30Hz AC/DC 0% sine +/ 0.2% wave. Sine wave at 0 cd/m² Flicker (JEITA method) cd/m² or higher +/ db flicker frequency 30Hz AC/DC 0% sine +/ 0.2dB wave. Sine wave at 0 cd/m² Operating temperature 03 C ² Shutter lifetime >0000 Shutter speed 20300 ms depending on temperature and lifetime All measurements are performed 20 times on a LED display with sufficient signal noise ratio, value is based on 2 sigma. Sample speed depends on the measured sample. If the sample uses PWM, it will take longer. Use of lower rated values is strongly recommended to ensure repeatability. 2 Operating temperature reaches from 0 to degrees. Dark level compensation is optimized for operating in temperatures between 0 and 3 degrees.

6 0mm improved measurement specifications Measurement system Optical system Acceptance angle º (+/ 2.) Measurement spot size 4.4 mm at 0 mm distance 8.7 mm at mm distance Flicker measurement speed (sample mode) Luminance 2000 samples / second, XYZ 2000 samples / second Correct detected frequency of at least Hz Colour measurement speed Colour 22 ms or higher, depending on luminance level (including communication) 0 cd/m² with DC level light at 6 ms. PWM requires longer integration (multiple frames) Sample mode signal frequency response Parameter a F 3db Gain DC 00 Hz Gain 2 DC 00 Hz Gain 3 DC 00 Hz Colorimeter specification Parameter Range Accuracy Repeatability Resolution 6 bit for X, Y and Z >80 db without averaging Luminance (Y) 0.003 cd/m² 2,000 cd/m² +/2% of measured value, measured at white image Y +/ % at 0. cd/m² ¹ integration time between of LCD display, Luminance of app. 0 cd/m², Y +/ 0.% at cd/m² ¹ 0.ms s x=00 y= 2 Y +/ 0.% at cd/m² ¹ Y +/ 0.% at 0 cd/m² ¹ Chromaticity (x,y) +/ 0.00 after calibration, measured at white image of LCD display, Luminance of app. 0 cd/m², x=00 y= 2 x,y +/ 0.0007 for Y at 0. cd/m² ¹ x,y +/ 0.0003 for Y at cd/m² ¹ x,y +/ 0.0003 for Y at cd/m² ¹ x,y +/ 0.0002 for Y at 0 cd/m² ¹ Measurement speed samples / s for Y at 0. cd/m² ¹ 020 samples / s for Y at cd/m² ¹ samples / s for Y at cd/m² ¹ samples / s for Y at 0 cd/m² ¹ Flicker (contrast method) cd/m² or higher +/ % flicker frequency 30Hz AC/DC 0% sine +/ 0.2% wave. Sine wave at 0 cd/m² Flicker (JEITA method) cd/m² or higher +/ db flicker frequency 30Hz AC/DC 0% sine +/ 0.2dB wave. Sine wave at 0 cd/m² Operating temperature 03 C ² Shutter lifetime >0000 Shutter speed 20300 ms depending on temperature and lifetime All measurements are performed 20 times on a LED display with sufficient signal noise ratio, value is based on 2 sigma. Sample speed depends on the measured sample. If the sample uses PWM, it will take longer. Use of lower rated values is strongly recommended to ensure repeatability. 6 2 Operating temperature reaches from 0 to degrees. Dark level compensation is optimized for operating in temperatures between 0 and 3 degrees.

7 0mm measurement data Luminance Setting : max integration time ms Setting 3: max integration time 2ms Setting 2: max integration time 0ms Measurement range from to level level from to level level from to level level (%) (%) (%) 0.00 0.00 0.00 Accuracy (for white) Repeatability (2 sigma) 0.0 0. 0 0.0 0. 0 +/% +/% +/4% +/3% +/3% +/2% +/2% +/2% +/% +/% +/.2% +/0.6% +/% +/% +/0.2% +/% +/ 0.000 +/0.00 +/ 0.0036 +/0.006 +/0.0 +/0.04 +/0.0 +/0 0.0 0. 0 0.0 0. 0 +/% +/% +/4% +/3% +/3% +/2% +/2% +/2% +/3% +/0.6% +/0.% +/0.% +/% +/% +/0.2% +/0.08% +/0.0003 +/0.0006 +/0.00 +/0.00 +/0.0 +/0.04 +/0.06 +/0.08 0.0 0. 0 0.0 0. 0 +/% +/% +/4% +/3% +/3% +/2% +/2% +/2% +/% +/0.% +/0.2% +/0.2% +/0.% +/0.3% +/0.07% +/0.07% +/0.000 +/0.000 +/0.0006 +/0.002 +/0.007 +/0.09 +/0.03 +/0.07 7

Chromaticity Setting : max integration time ms Setting 3: max integration time 2ms Setting 2: max integration time 0ms Measurement range from to level from to level from to level 0. 0. 0. Accuracy (for white) Repeatability (2 sigma) 0. 0 0. 0 +/0.00 +/0.002 +/0.002 +/0.00 +/0.00 +/0.00 +/0.00 0.006 0.0026 0.0006 0.00066 0.0003 0.0007 0.0004 0. 0 0. 0 +/0.00 +/0.002 +/0.00 +/0.00 +/0.00 +/0.00 +/0.00 0.0037 0.004 0.0006 0.00067 0.00028 0.0002 0.0002 0. 0 0. 0 +/0.003 +/0.002 +/0.00 +/0.00 +/0.00 +/0.00 +/0.00 0.00 0.00022 0.00033 0.00066 0.00033 0.00022 0.000 Speed Setting : max integration time ms Setting 3: max integration time 2ms Setting 2: max integration time 0ms from to times/sec from to times/sec from to times/sec xylv 0. 0 8 8 0 0. 0 3.7 3.7 0 0. 0 0.6 0.9 0.6 0.9 0 8

8 0mm improved measurement data Luminance Setting : max integration time ms Setting 3: max integration time 2ms Setting 2: max integration time 0ms Measurement range from to level (%) level from to level (%) level from to level (%) level 0.003 2000 0.003 2000 0.003 2000 Accuracy (for white) Repeatability (2 sigma) 0.0 0. 0 0.0 0. 0 2000 2000 +/% +/% +/4% +/3% +/3% +/2% +/2% +/2% +/3% +/0.9% +/0.9% +/0.6% +/% +/% +/0.2% +/% +/0.0003 +/0.0009 +/0.0027 +/0.006 +/0.0 +/0.04 +/0.0 +/0 0.0 0. 0 0.0 0. 0 2000 2000 +/% +/% +/4% +/3% +/3% +/2% +/2% +/2% +/2% +/0.% +/0.% +/0.4% +/% +/% +/0.2% +/0.08% +/0.0002 +/0.000 +/0.00 +/0.004 +/0.0 +/0.04 +/0.06 +/0.08 0.0 0. 0 0.0 0. 0 2000 2000 +/% +/% +/4% +/3% +/3% +/2% +/2% +/2% +/0.6% +/0.4% +/0.2% +/0.% +/0.3% +/0.% +/0.06% +/0.06% +/0.000 +/0.0004 +/0.0006 +/0.00 +/0.006 +/0.062 +/0.030 +/0.06 9

Chromaticity Setting : max integration time ms Setting 3: max integration time 2ms Setting 2: max integration time 0ms Measurement range from to level from to level from to level 0.003 2000 0.003 2000 0.003 2000 Accuracy (for white) Repeatability (2 sigma) 0. 0 0. 0 2000 2000 +/0.00 +/0.002 +/0.002 +/0.00 +/0.00 +/0.00 +/0.00 0.004 0.0020 0.0004 0.0006 0.00032 0.0007 0.0004 0. 0 0. 0 2000 2000 +/0.00 +/0.002 +/0.00 +/0.00 +/0.00 +/0.00 +/0.00 0.002 0.0009 0.00043 0.000 0.00028 0.0002 0.0002 0. 0 0. 0 2000 2000 +/0.003 +/0.002 +/0.00 +/0.00 +/0.00 +/0.00 +/0.00 0.0007 0.00022 0.00033 0.00066 0.00033 0.00022 0.000 Speed Setting : max integration time ms Setting 3: max integration time 2ms Setting 2: max integration time 0ms from to times/sec from to times/sec from to times/sec xylv 0. 0 2000 8 8 0 0. 0 2000 3.7 3.7 0 0. 0 2000.2. 0

9 Hyperion 0mm dimensions

0 Hyperion 0mm improved dimensions 2

Hyperion M8 fibre dimensions 3

Admesy B.V. Sleestraat 3 604 CA Ittervoort The Netherlands T +3 (0)47 600 232 F +3 (0)47 600 36 www.admesy.com info@admesy.com The material in this document is subject to change. No rights can be derived from the content of this document. All rights reserved. No part of this document may be reproduced, stored in a database or retrieval system, or published in any form or way, electronically, mechanically, by print, photo print, microfilm or any other means without prior written permission from the publisher. Version.. /207 4