Similar documents
Time meter electronic

Multifunction devices

Pulse Counters, electronic

Preset counters, electronic

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Preset counters, electronic

Operating instructions Electronic preset counter Type series 717

Electronic Pulse Counter Combination device

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Preset counters, electronic

Pulse Counters, electromechanical

Counting and Process Technology 2009 / 2010

Linear encoders without bearings incremental System for linear motion feedback

Bedienungsanleitung KCT2-6ST-V KC-LED-96-1T-24VDC

Eaton Durant. Counters, process instruments and hour meters.

Flexible Counter Series in DIN size 24 x 48 mm

CODIX 560. Elektronischer Vorwahlzähler mit zwei Vorwahlen. Electronic Preset Counter With two presets

48x24. Options ORDER NUMBER OF TYPE PFL B

Flexible Counter Series in DIN size 24 x 48 mm

02/11/2015

Multifunction Digital Timer

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

Operating Instructions

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

Material: Weight: IP Rating: Cable: Connector:

Operating Instructions

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

Counting Technology Counters, Timers, Tachometers

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Solution Selection Guide

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218


Solution Selection Guide

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

SPECTRO Series SPECTRO-1-50-DIL. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

Operating Instructions

SIGNET 5500 Flow Monitor ENGLISH

263 Series LED Bargraph Indicator and Controllers

SPECTRO Series SPECTRO-3-50-FCL. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 10)

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Transmitter optics with 9x white light LED (optics cover made of glass)

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

SPECTRO Series SPECTRO-1-30-UV/UV. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

Displacement Measuring System for Cylinder Series OSP-P

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Electrical connection

VAT 20 Adjustable Frequency Drive

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Data Sheet SPECTRO-3-SLU-BA-ANA + SI-SLU-16. Receiver optics incl. 3-color filter detector (True Color), scratch-resistant optics cover made of glass

Electrical connection

SPECTRO Series SPECTRO /0 -MSM-ANA-VIS. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p. 8-9) Product name:

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

Single Axis Position Controller

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

MICRO SERIES COUNTERS & TIMERS LARGE DIGIT MODEL

L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

DCP100 Digital Control Programmer Specifications

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

SPECTRO Series SPECTRO-3-5-DIF-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Self--powered Time Counter

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

AF-300 E11 Adjustable Frequency Drive

Operating instructions Electronic Preset Counter with two presets LCD positive, green backlighting relay outputs E89005

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Counters. 1/32 DIN), programmable preset counter/timer with an integrated RS-485 communication port.

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

FIELD MOUNTED RATE TOTALISER MODEL 202D

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

SCALE & WEIGHT DISPLAYS

Standard signal metering in wall-mounting case

ENC - LKE51 - L I B

Solid-State Digital Timer

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

Selection matrix for electronic pressure switches

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

SPECTRO Series SPECTRO-1-POF. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Accessories: (p ) Product name:


Detect Color and Shape for various inspection

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Simply clever! The digital DIN-rail time switches by Grässlin

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

Separate Thin Amplifier type. AP-V40AW Series

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Transcription:

Hour Meters / Timers, electronic LED Timers Codix 523 For use as a timer, hour meter or short-time meter Pulse width measurement (operating time) Time interval measurement (start/stop) DC 000000 0... 30V DIN 24 x 48 Power supply Front bezel DC dimensions -20 +65 Wide temperature range Powerful High accuracy Thanks to quartz time base Robust housing IP 65 protection LED display Very bright, 8 mm high Time base can be set individually Hours, minutes or seconds can be set even more precisely thanks to the max. 3 decimal places. Smallest attainable resolution: milliseconds Fast start-up time Detects incoming pulses just 6 ms after being switched on > so no pulses are lost with a simultaneous motor start-up Time measurements such as hours run recording on all machines and plant, e.g. compressors, solariums, special lights and lamps Accessories, OEM equipment or retrofitting to production machine High IP protection rating 65 ms Menu-driven programming User-friendly Timer/ Hour Meter Applications for time and hour meters, short-time meters Resolution Big keys Pressing either of the keys switches between displays Can also be operated when using gloves Easy to programme Easy menu-driven programming and operation Possibility to enter the programming mode during operation, with authentication query Measurement of short times on processes and procedures, time recording (stopwatch function) at sporting events Hours run recording for motor vehicles and time monitoring for rally vehicles RoHS Universal Individually programmable start/stop function By means of 2 start/stop inputs, up to 4 different measuring principles can be achieved, e.g. active or passive pulse width measurement, time interval measurement with one input or with separate inputs Manual or electrical reset Tamper-proof, due to lockable reset function User-programmable setpoint Start time at which the time counting should begin DC power supply With sensor power supply Inputs As an alternative to the HTL inputs, devices with a 4... 30 V DC input level are available, for use as parallel displays for PLCs Optional output Hz clock pulse for active time measurement START FINISH Hours run of UV lamps Operating hours Short time measurement > ms Clearwater Tech - Phone: 800.894.042 - Fax: 208.368.045 - Web: www.clrwtr.com - Email: info@clrwtr.com

Hour Meters / Timers, electronic LED Timers Codix 523 Technical data: Supply voltage: Current consumption: Display: Data backup: 0... 30 V DC, with reverse polarity protection max. 55 ma 6-digit 7-segment red LED; 8 mm [0.35 ] high EEPROM Housing: dimension 48 x 24 mm [.89 x 0.945 ] according to DIN 43 700; RAL 702, grey Polarity of Inputs: programmable, npn or pnp for all inputs Input resistance: approx. 5 kw Resolution: up to 0.00 s Reset time: 5 ms low: 0... 0.2 x U B high: 0.6 x U B... 30 V DC low: 0... 2 V DC 4... 30 V DC version high: 4... 30 V DC Optocoupler output: max. 30 V, 0 ma Accuracy: <50 ppm Ambient temperature: -20... +65 C [4... 49 F] at Ub = 0...26 V DC -20... +55 C [4... 3 F] at Ub = >26... 30 V DC non condensing Storage temperature: 25... +70 C [ 3... 58 F] EMC: Immunity to interference: EN550 class B Emitted interference EN6000-6-2 Protection: IP65 front side Weight: approx. 50 g [.764 oz] Block diagram: Power supply: 0...30 V DC Display 523.0 2 Timers Count input Reset input A B µ-processor optional output Dimensions: 28 [.03] 40 [.575] 32 [.26] 48 [.89] 22.2 +0.3 x 45 +0.6 mm [0.874 +0.02 x.772 +0.024 ] Front bezel 53 [2.087] 56 [2.205] [0.866 x.772] [0.039] 59 [2.323] 25 [0.984] Keyboard max. 9.3 [0.76] 25 +0.5 [0.984 +0.02 ] 50 +0.6 [.969 +0.024 ] [0.04] M3 50 [.969] 22.2 +0,3 [0.874 +0.02 ] Panel cut-out 32 ±0. [.26 ±0.004 ] 45 +0,6 [.772 +0.024 ] Counter sinking Af3, DIN 74 without optocoupler 0... 30 VDC with optocoupler (npn) 0... 30 VDC 6 Emitter 7 Collector Delivery specification: Digital display Panel mounting clip Bezel for screw mounting, panel cut out 50 x 25 mm [.969 x 0.984 ] Bezel for clip mounting, panel cut out 50 x 25 mm [.969 x 0.984 ] Gasket Multilingual operating instruction Order code: 6.523.0X.3X0 * Standard stock model Input switch level 0 = Standard* A = 4... 30 V DC Output = Optocoupler 2 = No output* Clearwater Tech - Phone: 800.894.042 - Fax: 208.368.045 - Web: www.clrwtr.com - Email: info@clrwtr.com

Multifunction Counter, electronic LED Multifunction Counters Codix 524 programmable as: Pulse counter Position display / speed display Timer/ short time meter DC 000000 0... 30V DIN 24 x 48 Power supply Front bezel DC dimensions -20 +65 Wide temperature range Powerful Fast count input Input frequency max. 60 khz Robust housing IP 65 protection LED display Very bright, 8 mm high HRA High Rate Accuracy System Frequencies up to 38 Hz are calculated using time-interval (period duration) measurement. Frequencies > 38 Hz are calculated using a special time base (gate time) measurement. A very high accuracy of < 0.% is achieved, even with very short gate times. The resulting measurement is available after a max. of 50 ms. Fast start-up time Detects incoming pulses just 6 ms after being switched on > so no pulses are lost with a simultaneous motor start-up Applications for Multi-function Display Counting tasks such as quantity and piece counting, measuring and recording of speed and of operating and processing times Piece counting or tool-life measurement on die cutters, presses, extruders, woodworking machines, drilling machines, 65 High IP protection rating Menu-driven programming User-friendly max. 00000 60 khz POSITION /sec /min Pulse counter/ Totaliser Position display Big keys Can also be operated when using gloves Easy to programme Easy menu-driven programming and operation Possibility to enter the programming mode during operation, with authentication query pick-and-place machines, guillotines, special-purpose vehicles etc. Positioning tasks on processing machines, such as sawing machines, milling machines, bending and folding machines, etc. RoHS meter/ Tachometer Timer/ Hour Meter t Hz HRA meter HRA Universal Individually programmable scaling Multiplication and division factor (0.000 to 99.9999), to display corresponding engineering units, e.g. position in /0 mm and speed in RPM 4 different count input modes 2-channel input for detecting count direction, difference or adding mode, quadrature x, x2 or x4 measurement Display in /min or /sec Time counting Pulse width or time interval measurement in hours, minutes or seconds, as well as real-time display DC power supply Inputs As an alternative to the HTL inputs, devices with a 4... 30 V DC input level are available, for use as parallel displays for PLCs. Optional output Zero signal for position and count, zerospeed monitoring, Hz clock pulse for active time measurement Production data acquisition by means of piece counting (using difference or adding), or measurement of production times or production speeds Totalizing flow, quantity and other scaleable media, or display of current flow rates Position or rotary speed on milling machine Piece count on conveyor or production speed Drilling machine head, speed or drilling depth Clearwater Tech - Phone: 800.894.042 - Fax: 208.368.045 - Web: www.clrwtr.com - Email: info@clrwtr.com

Multifunction Counter, electronic LED Multifunction Counters Codix 524 Technical data: Supply voltage: 0... 30 V DC, with reverse polarity protection Current consumption: max. 55 ma Display: 6 digit red 7-segment LED; 8 mm [0.35 ] high Data backup: EEPROM Housing: dimension 48 x 24 mm [.89 x 0.945 ] according to DIN 43 700; RAL 702, grey Polarity of inputs: programmable, npn or pnp for all inputs Input resistance: approx. 5 kw Counting frequency: 60 khz, can be damped to 30 Hz Display range timer: 0.00 s... 999999 h Reset time: 5 ms low: 0... 0.2 x U B [V DC] high: 0.6 x U B... 30 V DC low: 0... 2 V DC (4... 30 V DC version) high: 4... 30 V DC Optocoupler output: max. 30 V, 0 ma Accuracy: tachometer: <0. % timer: 50 ppm EMC: Emitted interference: EN550 Class B Immunity to interference: EN6000-6-2 Ambient temperature: -20... +65 C [4... 49 F] at Ub = 0...26 V DC (non condensing) -20... +55 C [4... 3 F] at Ub = >26... 30 V DC Storage temperature: -25... +70 C [ 3... 58 F] Protection: IP 65 front side Weight: approx. 50 g [.764 oz] Block diagram: Power supply: 0...30 V DC Display 52402 Count input Reset input A B µ-processor optional output Keypad Dimensions: 28 [.03] 40 [.575] 32 [.26] 48 [.89] 22.2 +0.3 x 45 +0.6 mm [0.874 +0.02 x.772 +0.024 ] Front bezel 53 [2.087] 56 [2.205] [0.866 x.772] [0.039] max. 9.3 [0.76] 59 [2.323] 25 +0.5 [0.984 +0.02 ] 25 [0.984] [0.04] M3 48 [.89] 50 +0.6 [.969 +0.024 ] 50 [.969] 22.2 +0,3 [0.874 +0.02 ] Panel cut-out 32 ±0. [.26 ±0.004 ] 45 +0,6 [.772 +0.024 ] [0.866 x.772] Counter sinking Af3, DIN 74 without optocoupler 0... 30 V DC max. 9.3 [0.76] with optocoupler 0... 30 V DC 5 RESET 6 Emitter 59 [2.323] 7 Collector Delivery specifications: Digital display Panel mounting clip Bezel for screw mounting, panel cut out 50 x 25 mm [.969 x 0.984 ] Bezel for clip mounting, panel cut out 50 x 25 mm [.969 x 0.984 ] Gasket Multilingual operating instruction Order code: 6.524.0X.3X0 * standard stock model Input switch level 0 = Standard* A = 4... 30 V DC level Output = Optocoupler output* 2 = No output* Clearwater Tech - Phone: 800.894.042 - Fax: 208.368.045 - Web: www.clrwtr.com - Email: info@clrwtr.com Multifunction

Time meter electronic Universal with dual functions CODIX 52U DC 000000 0... 30V DIN 24 x 48 Power supply Front bezel DC dimensions -0 +50 65 Wide temperature range High IP protection rating Powerful Fast count input Input frequency max. 60 khz Robust housing IP 65 protection LED display Very bright, 8 mm high HRA High Rate Accuracy System Frequencies up to 38 Hz are calculated using time-interval (period duration) measurement. Frequencies > 38 Hz are calculated using a special time base (gate time) measurement. A very high accuracy of > 0.% is achieved, even with very short gate times. The resulting measurement is available after a max. of 50 ms. Fast start-up time Detects incoming pulses just 6 ms after being switched on so no pulses are lost with a simultaneous motor start-up 4 dual functions in one device Counter with 2 totalizing ranges > solves all applications where Totaliser and time counter 2 different values must be displayed simultaneously. Totaliser and frequency counter Timer with 2 time ranges Menu-driven programming RoHS User-friendly max. 00000 60 khz /sec /min Pulse counter/ Totaliser meter/ Tachometer Big keys Can also be operated when using gloves Easy to programme Easy menu-driven programming and operation Possibility to enter the programming mode during operation, with authentication query Pressing the right key switches between displays Timer/ Hour Meter t Hz HRA meter HRA Universal Individually programmable scaling Multiplication and division factor (0.000 to 99.9999), to display corresponding engineering units, e.g. position in /0 mm and speed in RPM Separate factors for frequency- and pulse counting DC power supply Inputs As an alternative to the HTL inputs, devices with a 5 VDC input trigger level are available, for use as parallel displays for PLCs Timer specials Timer or hours-run meter with various Start Stop measurements, time range settings in hours, minutes or seconds, with decimal point. Resolutions up to /000 can be programmed Applications for dual functions Pulse and frequency (speed) e.g. production data acquisition: total piece count and speed on OEM equipment, flow rate measuring systems total flow and current flow 2 pulse counters Measurement of batch and total piece count or of daily production count and total count values Pulse and time (Maintenance counter) Used in the lift industry as trip counters and hours-run meters and on production machines for piece and time counting, flow and time measurement, materials handling time and quantities 2 timers Measurement of total time and orderspecific times, maintenance intervals and total time, time of day and total time. Piece count on conveyor and production speed Trip counter and hours-run Flow rate and total volume Clearwater Tech - Phone: 800.894.042 - Fax: 208.368.045 - Web: www.clrwtr.com - Email: info@clrwtr.com

Time meter electronic Universal with dual functions CODIX 52U Technical data: Supply voltage: Current consumption: Display: Data backup: 0... 30 V DC, with reverse polarity protection max. 40 ma 6-digit red 7-segment LED; 8 mm [0.35 ] high EEPROM Housing: dimension 48 x 24 mm [.89 x 0.945 ] according to DIN 43 700; RAL 702, grey Polarity of inputs: programmable, npn or pnp for all inputs Input resistance: approx. 5 kω Display range: 0.00 s... 999999 h Reset time: 5 ms Low: 0... 0.2 x U B [V DC] High: 0.6 x U B... 30 V DC Low: 0... 2 V DC 5 V version High: 4... 30 V DC Optocoupler output: Max. 30 V, 0 ma Accuracy: <0. % ( display, tachometer) EMC: according to EC EMC directive 89/36/EWG Immunity to interference: EN 6000-6-4/EN 550 class B Emitted interference: EN 6000-6-2 Ambient temperature: 0... +50 C [4... 22 F] Storage temperature: 25... +70 C [ 3... 58 F] Protection: IP 65 front side Weight: approx. 50 g [.764 oz] Block diagram: Power supply: 0...30 V DC Display 52U.0 2 Count input Reset input A B μ-processor Timers Keypad Dimensions: 48 [.89] [0.866 x.772] max. 9.3 [0.76] Panel cut-out 45 +0,6 [.772 +0.024 ] without optocoupler 0... 30 V DC 22.2 +0,3 [0.874 +0.02 ] 22.2 +0.3 x 45 +0.6 mm [0.874 +0.02 x.772 +0.024 ] 28 [.03] Front bezel 53 [2.087] 56 [2.205] [0.039] 25 +0.5 [0.984 +0.02 ] 50 +0.6 [.969 +0.024 ] 50 [.969] Delivery specifications: Digital display Panel mounting clip Bezel for screw mounting, panel cut out 50 x 25 mm [.969 x 0.984 ] Bezel for clip mounting, panel cut out 50 x 25 mm [.969 x 0.984 ] Seal Multilingual operating instructions 40 [.575] 32 [.26] 25 [0.984] [0.04] M3 32 ±0. [.26 ±0.004 ] Counter sinking Af3, DIN 74 Order code: 6.52U.02.3X0 * standard stock model Input switch level 0 = Standard* A = 5 V Clearwater Tech - Phone: 800.894.042 - Fax: 208.368.045 - Web: www.clrwtr.com - Email: info@clrwtr.com