Signet 2250 Hydrostatic Level Sensor

Similar documents
Mechanical flow switch for On/Off control

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Single Point Flow Monitor SW118 SW119

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

LAUREL ELECTRONICS, INC.

DMP 331i / DMP 333i LMP 331 i

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Modular Lube Lubrication Systems System Controls

Selection matrix for electronic pressure switches

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

2291 Guided Wave Radar Level Transmitter

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

SCALE & WEIGHT DISPLAYS

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

lubricated to facilitate insertion HAND TIGHTEN ONLY.

SIGNET 5500 Flow Monitor ENGLISH

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Wall-/Pipe-Mount Level Indicator

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

The full range of performance

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

T-Series "SMART" Sanitary Pressure Transmitter

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

3 Cleaning. 4 Technical data

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Environmental Technology, Inc.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

USER MANUAL. VDS Video Display System MODEL: P/N: Rev 2

Pressure transmitter COMPACT IO-Link,

Signet 2551 Magmeter. Contents 1.0 Description 1

ODW-621. RS-232 Point-to-point applications

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Level Measurement Point level measurement - RF Capacitance switches

TFRN Industrial RTD temperature sensor. CombiTemp TM

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

Operating Instructions

+GF+ SIGNET 8860 Dual Channel Conductivity/Resistivity Controller

Operating Instructions

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

DLM471S-5.1 MULTICHANNEL AUDIO LEVEL MASTER OPERATION MANUAL IB B. (Mounted in RMS400 Rack Mount & Power Supply) (One of 4 Typical Cards)

Operating instructions Electronic preset counter Type series 717

Digital Input Modules for Compact FieldPoint

TFRH Hygienic RTD temperature sensor. CombiTemp TM

SQM40/41 Actuators for air and gas dampers

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Marshall Electronics. Broadcast A/V Division VAC-HT12-KIT. 4K HDBaseT Extender Kit. User Manual

Electronic converter for level transmitters MT03L Instructions manual

Flow Switch. Flow Switch

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

SPECIFICATION NO NOTE

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

1x12 VGA & Audio over CAT5 Splitter

Capacitance Level Measurement Electronic insert FEC 12

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

EZ Encoder : Optical Incremental

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Material: Weight: IP Rating: Cable: Connector:

HS-509 VIBRATION TRIP MODULE

AF-300 E11 Adjustable Frequency Drive

DISTRIBUTION AMPLIFIER

Signet 8150 Flow Totalizer * * Rev. J 12/12 English

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Smart-Encoder : Optical Incremental

C200H-AD002/DA002 Analog I/O Units Operation Guide

TUC: Universal thermostat

Liquid Level Sensor Type AKS 4100U

Installation and Maintenance Instructions for GC51 Rangeable Pressure Transmitter

TFRN Industrial RTD temperature sensor. CombiTemp TM

Pressure transmitter For applications in hazardous areas Model IS-3

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

MICROMASTER Encoder Module

Level Measurement silometer FMC 420, FMC 423

Signet Chlorine Transmitter

T10 Float Level Switch

ZIG-POC-100. HDBaseT HDMI Extender

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Transcription:

Signet 2250 Hydrostatic Sensor *32250.090* 32250.090 Rev. A 10/06 English English Safety Instructions 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confi rm chemical compatibility before use. 3. Do not exceed maximum temperature/pressure specifi cations. 4. Wear safety goggles or faceshield during installation/service. 5. Do not alter product construction. 6. Dispose of properly; DO NOT INCINERATE! 1. Description The Signet 2250 Hydrostatic Sensor uses a gauge pressure sensor to calculate the level of fl uid in a tank. Gauge pressure sensors measure the difference in pressure between the process on one side of a diaphragm and the atmospheric pressure on the opposite side of the diaphragm. A tiny capillary tube running from inside the sensor body and up the length of the cable provides the reference to atmospheric pressure. Hydrostatic level measurement can be a simple and practical solution to those applications where the fl uid temperature is stable and constant. IMPORTANT! This method of level measurement is not recommended if the fluid is subject to temperature variations or any other variable that causes the density of the fluid to change. The 2250 Hydrostatic Sensor has excellent chemical compatibility. The wetted materials are PVDF, Ceramic and FPM. Several different hardware mounting kits are available to accommodate every installation requirement. 2. Specifications General Compatibility: Signet 82502 and 3 s Signet 8900 MultiParameter Controller Wetted Material Sensor housing: PVDF Diaphragm: Ceramic Diaphragm seal: FPM (optional EPDM) Cable type: Cable length: Operating Temperature: Storage Temperature: Operating Pressure: 22 AWG, 3 conductorcapillary tube 10 m (32.8 ft.) supplied max. extension 120 m (400 ft.) 15 C to 85 C (5 F to 185 F) 20 C to 100 C (4 F to 212 F) XU: 0 to 0.7 bar (0 to 10 psig) XL: 0 to 3.4 bar (0 to 50 psig) Electrical Digital (S 3 L) Output: Format: Serial ASCII, TTL level 9600 bps. Accuracy: ±1% of full scale (±0.001 psi) Power: 5 VDC nominal, 1.5 ma max. current (5 VDC min, 6.5 VDC max) Reverse polarity and short circuit protected Standards and Approvals: CE Manufactured under ISO 9001:2000 for Quality and ISO 14001:2004 for Environmental Management 4 to 20 ma Output: Factory span: XU: 0 to 0.7 bar (010 psig) = 07 m (23 ft.) of water XL: 0 to 3.4 bar (050 psig) = 034 m (115.5 ft.) of water Accuracy: ±1.2% of full scale (±32 µa) Resolution: <5 µa Response Time: <100ms Loop Power Required: 12 to 24 VDC nominal, 22.1 ma max (10.8 VDC min. to 26.4 VDC max.) Max. Loop Impedance: 100Ω @ 12V 325Ω @ 18V 600Ω @ 24V Dimensions ½ in. (ANSI) or 25 mm (ISO) Solvent Socket 53 mm (2.09 in) 115 mm (4.55 in) 34 mm (1.32 in)

Relay 1 Relay 2 Installation The 2250 can be assembled as a blind 420 ma signal connected by cable to a, Chart recorder or other 420 ma device. This type of installation requires no additional hardware. Direct 420 ma output The user must provide the ¾ in. conduit to protect the cable from damage. The 2250 cable is not suitable for direct submersion. 420 ma 322502XYZ The 2250 can be assembled as a digital sensor connected directly to a Signet 8250 or to a Signet 8900 MultiParameter Controller. Direct Digital output 10.00 ft Digital (S3L) 382502 382503 38900 322501XYZ IMPORTANT! A tiny capillary tube inside the sensor body is used to ensure that the back of the diaphragm remains at atmospheric pressure. If the capillary tube is blocked or damaged, the sensor cannot operate properly. If moisture is allowed to propagate down this tube to the rear of the diaphragm, the sensor may be damaged. Do not allow the cable to be bent or compressed. The ceramic diaphragm in the 2250 can be permanently damaged by overpressure conditions or by mechanical contact. HANDLE THESE SENSORS WITH CARE. 2 2250 Hydrostatic Sensor

Relay 1 Relay 2 Relay 1 Relay 2 Relay 1 Relay 2 Relay 1 Relay 2 2250 with 420 ma or Digital Output: Remote mounting The 2250 can provide a digital (S 3 L) signal out to the 8250, to a or to a chart recorder. 420 ma or Digital (S 3 L) signal out Clamped to Tank support 420 ma or Digital (S 3 L) signal out Mounted through Tank Cover 380521 ¾ in. conduit (customer supplied) 420 ma Out OR Digital (S 3 L) 10.00 ft 380501 ¾ in. conduit (customer supplied) 420 ma Out OR Digital (S 3 L) 10.00 ft 32250XX 382502 382503 38900 32250XX 382502 382503 38900 2250 with Digital Output: Integral mounting The 2250 can be assembled as an integral system, with the 8250 mounted directly atop the sensor. This confi guration provides a local display at the measurement site, plus the 420 ma and relay output features of the 8250. Integral Clamped to Tank support Integral Mounted through Tank Cover 382502 382503 10.00 ft 382502 382503 10.00 ft 38052 420 ma Out 38050 420 ma Out AND AND ¾ in. conduit (customer supplied) Control Relay Out C NC NO ¾ in. conduit (customer supplied) Control Relay Out C NC NO 32250XX 32250XX 2250 Hydrostatic Sensor 3

Relay 1 Relay 2 2250 Assembly Detail 1. Glue the union bushing onto the conduit. 6A: Remote system Cut the cable to length and terminate the wires at the terminal block inside the conduit base. CAUTION The capillary tube that runs the length of the sensor cable must remain open to the atmosphere. Do not allow it to be crimped or blocked. 2. Thread the sensor cable through the Oring, Union and through the ¾ in. conduit. 420 ma Out OR Digital (S 3 L) 10.00 ft 3. Thread the Union nut onto the Union bushing. CAUTION Hand tighten the nut. Do not use tools. 6B: Integral system Cut the cable to length and terminate the wires at the terminal block of a fi eld mount 8250. 4. Thread the ¾ in. conduit adapter or the universal adapter onto the top of the conduit. Use a suitable thread sealant to provide a watertight connection. CAUTION The capillary tube that runs the length of the sensor cable must remain open to the atmosphere. Do not allow it to be crimped or blocked. 420 ma Out 5. Mount the conduit base onto the adapter and secure the assembly with the locking ring. AND Control Relay Out C NC NO 4 2250 Hydrostatic Sensor

Digital (S 3 L ) wiring The 2250 provides digital (S 3 L ) output when powered with 5 VDC from the or from the MultiParameter Controller. Connecting the SHIELD to a direct Earth ground may reduce electrical noise interference. The maximum digital (S 3 L ) cable length is dependent upon the instrument to which the sensor is connected. Consult the instrument manual for details. 2250 to 82502 13 Gnd 12 I/O 11 V Black Red White Shield Optional Earth ground 2250 to 82503 18 17 16 15 14 13 Gnd I/O V Gnd I/O V Black Red White Shield Optional Earth ground White Red Black Shield 2250 to 8900 MultiParameter Controller I/O Module 38900.401X Frequency 5VDC (Black) Input Freq. Input (Red) 1 GND (Shield) 5VDC (Black) Frequency Input 2 OR S 3 L Input 2 S 3 L Input 1 Freq. Input 2 (Red) S 3L (Red) GND (White/Shield) 5VDC (Black) S 3L (Red) GND (White/Shield) Analog Output 1 (if applicable) Analog Output 2 (if applicable) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 38900.621C Black White Red Shield Optional Earth ground 2250 Hydrostatic Sensor 5

420 ma Loop Wiring The 225021X and 225022X models provide a 420 ma loop output when powered with 24 VDC. Connecting the SHIELD to a direct Earth ground may reduce electrical noise interference. Black (Loop ) Red (no connection) White (Loop ) Cable shield Power Supply DC 12 24 V Programmable Logic Controller 420 ma loop monitor Chart Recorder Datalogger Optional Earth ground 4 to 20 ma Span The 2250 is available in two factoryset span ranges: Models numbers ending with "U" or "U1" have a factory span of 0 to 10 psig. Model numbers ending in "L" or "L1" are spanned for 0 to 50 psig. The chart below lists the factory span of all available models. The level ranges in meters and feet are based on the mass of water. Mfr. Part No. Code 420 ma Span 3225021U 159 001 248 420 ma = 0 to 0.7 bar (010 psig) 0 to 7 m (0 to 23.09 ft.) 3225021L 159 001 247 420 ma = 0 to 3.4 bar (050 psig) 0 to 34 m (0 to 115.5 ft.) 3225022U 159 001 251 420 ma = 0 to 0.7 bar (010 psig) 0 to 7 m (0 to 23.09 ft.) 3225022L 159 001 252 420 ma = 0 to 3.4 bar (050 psig) 0 to 34 m (0 to 115.5 ft.) 3225021U1 159 001 482 420 ma = 0 to 0.7 bar (010 psig) 0 to 7 m (0 to 23.09 ft.) 3225021L1 159 001 483 420 ma = 0 to 3.4 bar (050 psig) 0 to 34 m (0 to 115.5 ft.) 3225022U1 159 001 484 420 ma = 0 to 0.7 bar (010 psig) 0 to 7 m (0 to 23.09 ft.) 3225022L1 159 001 485 420 ma = 0 to 3.4 bar (050 psig) 0 to 34 m (0 to 115.5 ft.) 6 2250 Hydrostatic Sensor

Respanning the 4 to 20 ma output The 4 to 20 ma span can be set to accommodate any application within the operating range of the sensor. The respanning procedure requires that the sensor be subjected to the actual pressure that will represent 4 ma and 20 ma. The procedure illustrated here assumes that the application requires that the sensor output is 4 ma when the tank is empty and 20 ma when the tank is full. To reverse the range, reverse steps 3 and 5. 1. 2. Black (Loop ) Red (no connection) White (Loop ) Power Supply DC 12 24 V Programmable Logic Controller 420 ma loop monitor Chart Recorder Datalogger Install the sensor. Wire the 420 ma Loop and turn the power ON. 3. 4. Black (Loop ) Red (no connection) White (Loop ) Power Supply DC 12 24 V = 4 ma Programmable Logic Controller 420 ma loop monitor Chart Recorder Datalogger Fill tank to the level represented by 4 ma. Short the RED and WHITE wires together for 15 seconds. 15s 5. 6. = 20 ma Black (Loop ) Red (no connection) White (Loop ) Power Supply DC 12 24 V Fill the tank to the level to be represented by 20 ma. Programmable Logic Controller 420 ma loop monitor Chart Recorder Datalogger Short the RED and BLACK wires together for 15 seconds. 15s 2250 Hydrostatic Sensor 7

Ordering Information Sensor Part Number 32250 Hydrostatic Sensor Sensor Output 1 Digital (S 3 L), 10 m (32.8 ft.) 2 Current (4 to 20 ma), 10m (32.8 ft.) Threaded Connection 1 ½ in. union connector 2 ¾ in. NPT threads Operating Pressure Range U 0 0.7 bar (010 psi) L 0 3.4 bar (050 psi) PVCU Union Connection ¾ in. socket 1 Metric pipe connector 32250 1 1 U Example Part Number Mfr. Part No. Code 3225011U 159 001 242 3225011L 159 001 241 3225012U 159 001 249 3225012L 159 001 250 3225021U 159 001 248 3225021L 159 001 247 3225022U 159 001 251 3225022L 159 001 252 Mfr. Part No. Code 3225011U1 159 001 478 3225011L1 159 001 479 3225012U1 159 001 480 3225012L1 159 001 481 3225021U1 159 001 482 3225021L1 159 001 483 3225022U1 159 001 484 3225022L1 159 001 485 Accessories and Replacement Parts Mfr. Part No. Code Description 55230222 159 000 392 Sensor cable, (per ft.) Consult Factory for assistance 39000.3921 159 000 839 Liquid tight connector kit, NPT (1 pc.) 39000.3922 159 000 841 Liquid tight connector kit, PG 13.5 (1 pc.) 38050 159 000 184 Universal mount kit 38052 159 000 188 ¾ in. Integral mount kit 380501 159 000 753 Universal Mount w/junction terminals 380521 159 000 755 ¾ in. Integral mount w/junction terminals George Fischer Signet, Inc. 3401 Aerojet Avenue, El Monte, CA 917312882 U.S.A. Tel. (626) 5712770 Fax (626) 5732057 For Worldwide Sales and Service, visit our website: www.gfsignet.com Or call (in the U.S.): (800) 8544090 32250.090 Rev. A 10/06 English George Fischer Signet, Inc. 2006 Printed in U.S.A. on Recycled Paper