WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Similar documents
1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Cylindrical Photoelectric Sensor CY-100 SERIES

Digital pressure sensor PPX series

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

GC61 Digital Pressure Gauge. Operation Manual

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

GC30 Digital Differential Pressure Gauge Operation Manual

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Separate Thin Amplifier type. AP-V40AW Series

Digital Flow Switch for Large Flow

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

100 : 1. Digital Flow Switch. PFMB Series 66 % 67% 76 % 81% 2-Color Display (Only 200 L type) Compact, Space saving

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Digital Flow Switch for Water 3 -color/2-screen display

APPLICATIONS. Automatic warehouse. Trasportation lines

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button.

Digital Flow Switch for Air/Water

Operating Instructions

Absolute Rotary Encoder E6CP

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Electrical connection

Photoelectrics Through-beam Type PA18C.T..., DC

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Self--powered Time Counter

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Digital Flow Switch for Water

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

3 -color/2 -screen display

3-color/ 2-screen display 1

APPLICATIONS. Automatic warehouse. Trasportation lines

Type F70AB F70ABPN. Digital display. Simple operation featured

Multifunction Digital Timer

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

LED Type Optical Displacement Sensor

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Inductive sensor NI3-EG08K-Y1-H1341

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DF-G3 Long Range Expert Dual Display Fiber Amplifier

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Photoelectric Sensors E3F2

Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. Teaching button

Inductive sensor NI10-M18-Y1X-H1141

Electromagnetic Type Digital Flow Switch

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Q3X Laser Contrast Sensor

Electromagnetic Digital Flow Switch

Signet 2250 Hydrostatic Level Sensor

Solid-State Digital Timer

D12 Expert Series TEACH-Mode Fiber Optic Sensors

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

K3NX Process Meter OPERATION MANUAL

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Digital Flow Monitor PFG3#0

02/11/2015

Inductive sensor BI1.5-EG08K-Y1

Digital Indicating ORP Meter AER-101-ORP. Instruction Manual

SU17 Series Fiber Optic Sensors

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Detect Color and Shape for various inspection

Inductive sensor With analog output BI15-M30-LI-EXI

Q3X Laser Contrast Sensor

Electromagnetic Type Digital Flow Switch

Mechanical flow switch for On/Off control

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

PROPORTIONAL VALVES Sentronic plus

panasonic-electric-works.net/sunx Machine safeguarding without sacrificing productivity

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Type. NPN output F71R F71G F71B F71W F71RH F71GH F71BH F71WH. Manual setting general-purpose type. Manual setting high-speed type

Electrical connection

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Lt DELTA USA, Inc

SA1J-F: Full Color Fiber Optic Sensors

Digital Gap Checker. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air STEP 2 STEP 3

Assembly. Front view. LEDs. Parametrization interface. Power Bus

USER S MANUAL. FX2N-8AD Analog input block

Transcription:

INSTRUCTI MANUAL Sensor High-performance Digital Display DP-1 Series Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference. WARNING Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Japanese Measurement Laws prohibit the use of this product in Japan. 1 2 NAMES OF EACH PART 1 operation indicator Lights up when comparative is 2 / analog voltage operation indicator : Lights up when comparative is : Lights up when analog voltage is set PIPING DP-1 Main display Sub-display Setting value DOWN key Setting value UP key Mode selection key MJE-DP1 No.691- Connection connector port DP-1 type: R 1 8 M5 female screw DP-1-E type: G 1 8 M5 female screw DP-1-N type: NPT 1 8 M5 female screw When connecting a commercial coupler to the pressure port, attach a 12mm spanner (14mm for DP-1-E type) to the pressure ports hexagon section to fix the port, and then tighten with a tightening torque of 9.8Nm or less. The commercial coupler or pressure port section will be damaged if the tightening torque is excessive. Wrap sealing tape around the coupler when connecting to prevent leaks. 12mm spanner For use outside Japan 4 WIRING Connection method Insert the cable with connector CN-14A-C into this products connection connector section as shown in the right figure. Disconnection method Pressing the release lever of the cable with connector, pull out thecable. Cable with connector CN-14A-C Release lever Note: Do not pull by holding the cable without pressing the release lever, as this can cause cable break. <Connection connector pin arrangement> 5 NPN type I/O CIRCUIT DIAGRAMS <Recommended product> Contact: SPHD-1T-P.5 Housing: PAP-4V-S [JST Mfg. Co., Ltd.] Connector pin No. Terminal name V : : Analog voltage or external input V When using the analog voltage, take care to the input impedance of the connected device. Furthermore, note that if the cable is extended, the cable resistance will cause the voltage to drop. 5V 1kΩ (Brown)V (Black) (White) Users circuit (Brown)V (White) Analog voltage or external input (Black) Users circuit PNP type 3 MOUNTING The sensor mounting bracket (MS-DP1-1) is available as an option. When mounting the sensor onto the sensor mounting bracket, etc., the tightening torque should be 1.2Nm or less. M3 (length 6mm) screws with washers (Accessory with MS-DP1-1) (Brown)V (Black) (White) Sensor mounting bracket MS-DP1-1 (Optional) Users circuit (Brown)V The panel mounting bracket MS-DP1-2 (optional) and front cover MS-DP1-3 (optional) are also available as options. M3 (length 12mm) pan head screw (Accessory with MS-DP1-2) 1kΩ (Black) (White) Analog voltage or external input Users circuit Front cover MS-DP1-3 (Optional) Panel cut-out size (Unit: mm) 31 Panel mounting bracket MS-DP1-2 (Optional) 31

6 OUTPUT AND OUTPUT OPERATI The EASY, hysteresis or window can be selected as the for comparative and comparative. Refer to /2 setting in 9 MENU SETTING for details. EASY / of the comparative is controlled in this. P H () H fixed (Note 1) Notes:1) can be fixed in 8 steps. Refer to < fixed value selection> in PRO 1 for setting. 2 is displayed for comparative and for comparative. The comparative / state can be controlled with randomly set hysteresis in this. Notes:1) can be fixed in 8 steps. Refer to < fixed value selection> in PRO 1 for setting. 2 or is displayed for comparative and or for comparative. 7 Lo SETTING <Setting procedures> RUN This is the pressure detection state. Refer to 8 RUN. Hi H () Note: or is displayed for comparative and or for comparative. In this, the or state of the comparative is controlled with a pressure in the set range. Hi Lo H () H: 1 digit or more 2 digits or more when using psi unit H () H fixed (Note 1) 8 RUN Setting the threshold value Refer to /2 setting and Analog voltage / external input selection in 9 MENU SET- TING for setting conditions. Since only the sub-display changes in the threshold setting, the following shows only the sub-display. Note: If the set pressure range is exceeded, (exceeds the upper limit) or (exceeds the lower limit) will appear on the sub-display. will also appear if the Hi side threshold value exceeds the Lo side threshold value when setting the hysteresis / window threshold value. <Setting condition 1> : : <Setting condition 2> : : <Setting condition 3> : : <Setting condition 4> : : () ( ) or ( ) ( ) or ( ) () DP-1 Press for 2 sec. MENU SETTING This is the setting for simple setting. Refer to 9 MENU SETTING. <Setting condition 5> : : ( ) or ( ) Press for 4 sec. PRO This is the setting for detailed setting. Refer to 1 PRO. <Setting condition 6> : : ( ) or ( ) ( ) or ( )

<Setting condition 7> : Analog voltage / external input selection: (Analog voltage ) <Setting condition 8> : Analog voltage / external input selection: (Auto-reference input) or (Remote zero-adjustment input) 9 MENU SETTING When the selection key is held for two seconds in the RUN, the menu setting will open. The will change to the RUN when the selection key is held during this setting process. The leftmost setting items are the default settings (factory settings). Press for 2 sec. < setting> (Note) (EASY ) < setting> (Note 1) <Setting condition 9> : ( ) or ( ) Analog voltage / external input selection: (Analog voltage ) ( ) (EASY ) <Analog voltage / external input selection> <Setting condition 1> : ( ) or ( ) Analog voltage / external input selection: (Auto-reference input) or (Remote zero-adjustment input) Analog voltage Auto-reference input <N.O. / N.C. selection> (Note 1) (Note 2) Remote zero-adjustment input 1: N.O. 2: N.O. 1: N.C. 2: N.C. <N.O. / N.C. selection> (Note 2) 1: N.O. 2: N.C. 1: N.C. 2: N.O. (Note) Note: Auto-reference value and remote zero-adjustment value are displayed. For details, refer to 12 AUTO-REFERENCE FUNCTI and 13 REMOTE ZERO-ADJUSTMENT FUNCTI. Common Zero-adjustment function The zero-adjustment function forcibly sets the pressure to zero when the pressure port is opened. (N.O.) (N.C.) <Response time setting> (2.5ms) (5ms) (5,ms) <Display color of the main display selection> Key lock function The key lock function prevents key operations so that the conditions set in each setting are not inadvertently changed. <Key lock set> (Key lock set) Red when Green when Red when Green when (Always red) MPa(Note 3) (kpa) (kgf/cm 2 ) (bar) (Always green) <Key lock released> (Key lock released) Peak / bottom hold function The peak / bottom hold functions display the peak value and bottom value of the fluctuating pressure. The peak value is displayed on the main display and the bottom value is displayed on the sub-display. Notes: 1) If the comparative setting is set to, the display of N.O. / N.C. selection is the same as the high-function type. 2) The default setting of the high pressure type is, and that of the low pressure type is. 3) The default setting of the low pressure type is. is not displayed. 4) This is not displayed on the high-pressure type. Setting item setting setting ( only) Analog voltage / external input selection ( only) N.O. / N.C. selection Response time setting Displayed color of the main display selection Unit selection (inchhg)(note 4) Description Sets the operation of comparative. Sets the operation of comparative. Selects analog voltage, auto-reference input, or remote zero-adjustment input. Normal open (N.O.) or normal close (N.C.) can be selected. Sets the response time. The response time can be selected from 2.5ms, 5ms, 1ms, 25ms, 5ms, 1ms, 25ms, 5ms, 1,ms or 5,ms. Displayed color of the main indicator can be changed. unit can be changed. (mmhg) (psi)

1 PRO When the selection key is held for four seconds in the RUN, the PRO will open. The will change to the RUN when the selection key is held during this setting process. In this case, the changed item is entered. The leftmost settings are the default settings (factory setting). for four seconds <PRO > <Sub-display selection> <Sub-display selection> When is set. When is set. Change the displayed details with and. List of code settings Code First digit N.O. / N.C. 1 selection N.O. / N.C. 2 selection Second digit High-func- tion type Analog voltage / external input Third digit Threshold display Analog voltage N.O. P-1, Lo-1 EASY Auto reference N.C. N.O. Hi-1 EASY Remote zeroadjustment N.O. N.C. P-2, Lo-2 N.C. N.O. Hi-2 N.O. N.C. ADJ. N.C. N.O. N.C. Fourth digit Standard Indication color of the main display type only Displayed color connection Red when Green when Always red Always green (Standard) (Display ) (Unit display) (Custom display) (No. display) Setting item Description Changes the indication of the sub-display. : Displays nothing. Sub-display selection Presently selected pressure unit is displayed. Desired No. can be shown Desired alphabets, numbers and signs can be shown. Display speed selection Changes the speed of the displayed pressure value on the main display. fixed value selection Displayed color relation selection ( only) Eco setting Setting check code Copy setting Reset setting <Display speed selection> 25ms (5ms) (1,ms) < fixed value selection> <Displayed color relation selection> Relating with comparative <Eco setting> (Standard) (Max.) <Setting check code> <Setting copy > <Reset setting> Relating with comparative (Max.) -L Sets hysteresis of the EASY and the window. (8 steps) The setting contents set at the displayed color setting in Menu setting can be related with either comparative or comparative. Current consumption can be lowered. : Normal operation (ECO is off.) : If any key operation is not carried out for approx. 5 sec. in RUN, the display becomes dark. : If any key operation is not carried out for approx. 5 sec. in RUN, the display is turned off. Press any key to return to the normal indication. Current setting contents can be checked. For codes. refer to List of code settings. The setting of the master side sensor can be copied to the slave side sensors. For details, refer to SETTING 11 COPY FUNCTI The setting contents are copied. The setting contents are copied, and the slave side sensor goes into key-lock state. Returns to default settings (factory settings). (Min.) Copy ready state Code Fifth digit 6th digit 7th digit 8th digit Response time Unit selection Display speed Eco 2.5ms MPa 25ms 5ms kpa 5ms Std 1ms kgf/cm 2 1,ms Full 25ms bar 5ms psi 1ms mmhg 25ms inchhg 5ms 1,ms 5,ms 11 SETTING COPY FUNCTI This can copy the settings of the master side sensor to the slave side sensor. Be sure to use the setting copy function between the identical ls. This function cannot be used between different ls. Only one sensor can be connected on slave side with a master side sensor for the setting copy function. <Setting procedure> Set the setting copy function of the master side sensor to or -L, and then press the selection key so that the sensor is in copy ready state. For details, refer to <Setting copy > in 1 PRO. Turn off the master side sensor. Connect the master side sensor with the slave side sensor as shown below. Power supply Master side sensor Slave side sensor (Brown)V (Brown)V (Black) (Black) (White) (Note 1) (White) (Note 1) Notes: 1) For the high-function type, analog voltage / external input. Turn on the master side sensor and the slave side sensor at the same time. (Note2) (Note 3) Set contents (16-bit coded) are shown in orange on the main display of the master side sensor and the copying starts. The same code explained above is shown in green on the the main display of the slave side sensor, and is shown on the sub-display (When copying is complete.) Turn off the power of the master side sensor and the slave side sensor and disonnect the wire. If copying the setting to another sensor repeatedly, follow steps to. Notes: 2) Take care that if the power is not turned on at the same time, the setting contents may not be copied. 3) Note that when the power is on, pulse is to comparative. <To cancel the setting copy of master side sensor> Whilst the slave side sensor is disconnected, turn on the power of the master side sensor. Press the selection key for approx. two seconds.

12 AUTO-REFERENCE FUNCTI (LY HIGH-FUNCTI TYPE) The auto-reference function corrects the setting value using the detected pressure value during Auto-reference input auto-reference input as the reference pressure. = P-A = P-A Using the setting value P-A fluctuation as a reference, the setting value is automatically corrected to setting value P-A. Atmospheric pressure P-A Settable range and set pressure range after correction The setting pressure range is wider than the rating pressure range so that the auto-reference function can be handled. If the corrected setting value exceeds the set pressure range during autoreference input, the setting value will be automatically corrected to within the set pressure range. Thus, take care not to exceed the set pressure range. Operation chart During normal operation (each comparative set to N.O.) Displayed value (kpa) 1 2 3 4 5 6 1 2 During remote zero-adjustment input (each comparative set to N.O.) Auto-reference input: 3kPa : Applied pressure (kpa) Displayed value (kpa) 1 2 3 4 5 6 1 2 3 4 5 6 P-A 3 4 5 Note: The setting values shift in the same manner during the EASY or the window. The auto-reference input value becomes zero when the setting of the analog voltage / external input selection is changed or the power is turned again. The auto-reference input value can be checked when setting the threshold value in RUN. Refer to the threshold value setting in 8 RUN for details.. 13 REMOTE ZERO-ADJUSTMENT FUNCTI (HIGH-FUNCTI TYPE) The remote zero-adjustment function forcibly sets the pressure value to zero when the external signal is input. The setting value is not corrected when remote zero-adjustment is input. Make sure that the pressure and setting value during remote zero-adjustment do not exceed the settable pressure range. Operation chart During normal operation (each comparative set to N.O.) Displayed value (kpa) 1 2 3 4 5 6 Displayed value (kpa) 1 2 3 4 5 6 1 2 4 5 Note: The setting values shift in the same manner during the EASY or the window. The remote zero-adjust input value is cleared when the setting of the analog voltage / external input selection is changed or the power is turned again, and normal operation based on the atmospheric pressure is resumed. The remote zero-adjustment value can be confirmed when setting the threshold value in RUN. Refer to the threshold value setting in 8 RUN. 14 ERROR INDICATI Error message Cause The load is short-circuited causing an overcurrent to flow. is applied during zero-point adjustment. The pressure during threshold setting exceeds the set pressure range. Communication error (Disconnection, faulty connection, etc.) Communication error (Incorrect l.) The applied pressure exceeds the upper limit of the display pressure range. The applied pressure exceeds the lower limit (reverse pressure) of the display pressure range. During remote zero-adjustment input (each comparative set to N.O.) Remote zero-adjustment input: 3kPa : Corrective action Turn the power and check the load. Applied pressure at the pressure port should be brought to atmospheric pressure and zero-point adjustment should be done again. Applied pressure range should be brought within the rated pressure range. Check the wiring when using the copy function. Make sure that the system is configured of the same ls when using the copy function. Applied pressure range should be brought within the rated pressure range. 14 MAIN SPECIFICATIS Model DP-1--- None: Cable with connector enclosed, J: No cable with connector None: NPN type, P: PNP type Type Item type Rated pressure range Set pressure range Withstand pressure Applicable fluid Supply voltage Power consumption operation Repeatability Response time Analog voltage External input None: R 1 8M5 female screw, E: G 1 8M5 female screw, N: NPT 1 8M5 female screw None:, A: 1: Low-pressure type, 2: High-pressure type Low-pressure type High-pressure type Low-pressure type High-pressure type Gauge pressure -1 to 1 kpa -.1 to 1. MPa -1 to 1 kpa -.1 to 1. MPa -1 to 1 kpa -.1 to 1. MPa -1 to 1 kpa -.1 to 1. MPa 5 kpa 1.5 MPa 5 kpa 1.5 MPa Non-corrosive gas 12 to 24 V DC 1% Ripple P-P 1 % or less Normal operation: 84W or less (current onsumption 35mA or less at 24V supply voltage) ECO (STD): 6mW or less (current onsumption 25mA or less at 24V supply voltage) ECO (FULL): 48mW or less (current onsumption 2mA or less at 24V supply voltage) <NPN type> NPN open-collector transistor Maximum sink current: 1mA Applied voltage: 3V DC or less (between comparative and V) Residual voltage: 2V or less (at 1mA sink current ) <PNP type> PNP open-collector transistor Maximum source current: 1mA Applied voltage: 3V DC or less (between comparative and V) Residual voltage: 2V or less (at 1mA source current ) Selectable either N.O. or N.C., with key operation 1 digit (min.) (however, 2 digits when using psi units).1% F.S..2% F.S..1% F.S..2% F.S. within 2 digits within 2 digits within 2 digits within 2 digits 2.5ms, 5ms, 1ms, 25ms, 5ms, 1ms, 25ms, 5ms, 1.ms or 5,ms selectable with key operations <High-function, low-pressure type> voltage: 1 to 5V Zero point: Within 3V 5%F.S. Span: Within 4V 5%F.S. Linearity: Within 1%F.S. impedance: 1kΩ approx. <High-function NPN type> voltage:.4vdc or less voltage: 5 to 3VDC or open Input impedance: 1kΩ approx. Input time: 1ms or more <High-function, high-pressure type> voltage:.6 to 5V Zero point: Within 1V 5%F.S. Span: Within 4.4V 5%F.S. Linearity: Within 1%F.S. impedance: 1kΩ approx. <High-function PNP type> voltage: 5V to V DC voltage:.6v DC or less or open Input impedance: 1kΩ approx. Input time: 1ms or more Ambient temperature -1 to 5 C (No dew condensation or icing allowed), Storage: -1 to 6 C Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH ±.5% F.S. ±1% F.S. ±.5% F.S. ±1% F.S. Temperature characteristics (2 C reference) (2 C reference) (2 C reference) (2 C reference) Material Enclosure: PTB (with glass fiber), LCD display: Acrylic, port: Brass (nickel-plated), Mounting screw section: Brass (nickel-plated), Switch: Silicon rubber Weight 4g approx.(dp-1-e type: 45g approx.) (Main body only) Accessories CN-14A-C2 (Cable with a connector, 2m long)optional for J type), Unit switching label: 1 pc. 15 CAUTIS SUNX Limited WARNING DP-1 series is designed for use with non-corrosive gas. It cannot be used for liquid or corrosive gas. Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Make sure that the power supply is off while wiring. Take care that wrong wiring will damage the sensor. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Do not use during the initial transient time (.5 sec.) after the power supply is switched on. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. The specification may not be satisfied in a strong magnetic field. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc, into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the keys with pointed or sharp objects. Make sure that stress by forcible bend or pulling is not applied directly to the sensor cable joint. This is a CE conformity product complying with EMC Directive. The standard with regard to immunity that applies to this product is EN 61-6-2, and in order to meet the standard, every cable connected to this product must be within 1m with.3mm 2, or more, cable. However, in case CE conformity is not required, the cable length can be up to 1m with.3mm 2, or more, cable. Head Office 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-91, Japan Phone: 81-()568-33-7211 FAX: 81-()568-33-2631 Overseas Sales Dept. Phone: 81-()568-33-7861 FAX: 81-()568-33-8591 http://www.sunx.co.jp/ PRINTED IN JAPAN