of of Re:connect M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03

Similar documents
Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

M203 LG. Multiroom Planer V2.00. Introduction. New features from software V2.00

of Loewe E 2.10_m1 1

Re:source. Communication Module. SAT Version. Dominating Entertainment. Revox of Switzerland. E2.00

of Switzerland of Switzerland Re:source FM Tuner Module Dominating Entertainment. Revox of Switzerland.

of Switzerland of Switzerland Re:system M51 MK2 Source Management Dominating Entertainment. Revox of Switzerland. V2.00

of t of and Re:connect M300 / M301 Video switch Dominating Entertainment. Revox of Switzerland.

of Switzerland FM Tuner MK2 E 2.01

and Re:system MR-Slave Module Dominating Entertainment. Revox of Switzerland.

CP-255ID Multi-Format to DVI Scaler

CSLUX-300I Multi-Format to HDMI Scaler

Display-Shoot M642HD Plasma 42HD. Re:source. DVS-5 Module. Dominating Entertainment. Revox of Switzerland. E 2.00

CSLUX-300I Multi-Format to HDMI Scaler

CSLUX-300 Multi-Format to HDMI Scaler

SUPERSCALE Multi-Format to HDMI Scaler

HDS-42AVR HDMI Switcher INSTALLATION MANUAL

BeoVision Guide

3-in 1- out DVI Switcher

Installation Guide. HDMI 4x1 Switcher

FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL

CH-2538TXWPKD 4K UHD HDMI/VGA over HDBaseT Wallplate Transmitter. CH-2527RX 4K UHD HDMI over HDBaseT Receiver. Operation Manual

Multi-format to HDMI scaler ID#15107

PRELIMINARY. Orbis CU. Preliminary Data Sheet!

INSTRUCTION MANUAL. 19 HD Widescreen Water Resistant Television VSPA19LCD-AE1B VSPA19LCD-AE1M VSPA19LCD-AE1W. Model No. FINGER TOUCH TECHNOLOGY RATED

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-437N Presentation Switcher/Scaler. P/N: Rev 2

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

Installation Guide SY-MS51. and SY-MS51-AP. Scaling Presentation Switcher

CP-255ID CV, SV, VGA and DVI to DVI Scaler / Converter OPERATION MANUAL

P-2 Installing the monitor (continued) Carry out as necessary

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

CMSDI G-SDI Matrix

isync HD & isync Pro Quick Reference Guide isync HD isync Pro Digital Video Processor and Video/Audio Switcher

USER MANUAL. VP-427 HDBaseT to HDMI Receiver/Scaler MODEL: P/N: Rev 5

Contents. Adaptive Sound Technology, 25 How to set up loudspeakers and optimise the sound experience with Adaptive Sound Technology.

Kramer Electronics, Ltd. USER MANUAL. Model: VP-437xl. Presentation Switcher / Scaler

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-436N Presentation Switcher/Scaler. P/N: Rev 1

Any feature not specifically noted as supported is not supported.

4-in 1-out HDMI v1.3 With Digital Audio Switcher

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

PRO-SDI44/84/124/164. 4x4/8x4/12x4/16x4 3G-SDI Matrix Switchers OPERATION MANUAL

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 Operating Instruction

UHF REMOTE RECEIVER INSTALLATION & PROGRAMMING

GET STARTED. For assistance, call us on or visit manhattan-tv.com/help

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708)

HDMI & VGA Receiver over IP with USB Connections - ID# & 15456

Model CMX3838A2 AV Matrix Switch with DSP audio (firmware 1.0)

Globalmediapro SMR-650

USER MANUAL. VP-427A HDBaseT to HDMI+Audio Receiver/Scaler MODEL: P/N: Rev 1

HDMI Switcher ITEM NO.: HS04, HS07, RC01

CS-801H HD High Resolution Scaler with 3D

HDMI 4x2 Matrix. Operation Manual CHMX-42

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher

VGA AUDIO SWITCHER S MANUAL

H25 DIRECTV Receiver. The New H25 IRD. Overview

EL-41AT. 4 in, 1 out v1.3 HDMI Switcher with Independent Audio OPERATION MANUAL

PR FESSIONAL PROFESSIONAL TERRESTICAL FM-FM PTFF Grundig SAT Systems

VS-TV. User manual. Virtual Matrix ENGLISH

4-in 1-out HDMI With Digital Audio Switcher

VLHDMIEXTFIB_2017V1.0

SY-MS121 SY-MS121-AP

CSC PC/Video/HD to HDMI 1.3 Switcher Operation Manual. Operation Manual CSC-5300

DIGITAL SET TOP BOX STB 7017 INSTRUCTION MANUAL

USER MANUAL. VP-437N Presentation Switcher/Scaler MODEL: P/N: Rev 3

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

GET STARTED. For assistance, call us on or visit manhattan-tv.com/support

HDMI 2x4 Matrix. Operation Manual CHMX-24

SY-HDBT-100 Extender Set

Contents. Adjust picture and sound settings, 32 How to make settings for picture and how to adjust bass, treble, etc. How to use game mode.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

H25 DIRECTV Receiver Mid-America Satellite 3047 Bartold Ave. St. Louis, MO 63143

Copyright 2008~2009 Taifatech Inc. All rights reserved. Version 1.08

USER MANUAL. VP-435 Component / UXGA HDMI Scaler MODEL: P/N: Rev 13

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

HDMI 4x4 Matrix. Operation Manual CHMX-44

USER MANUAL. VP-424 HDMI to HDMI Scaler MODEL: P/N: Rev 2

USER MANUAL. VP-425 PC / Component to HDMI Scaler MODEL: P/N: Rev 3

DT1-LR. for Landrover touch-screen navigation systems version 1

KV-901T & AV-901R. Quick Guide

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

DVB-LR10. Compatible with Land Rover touch-screen navigation systems version 2

RMS 8424S Quick Start

USER MANUAL. VP-422 HDMI to PC Scaler MODEL: P/N: Rev 5

Omega 4K/UHD Three-Input Switcher. Introduction. Applications. for HDMI and USB-C with HDBaseT and HDMI Outputs

CMLUX-4H4CAT. 4 by 4 HDMI V1.3 over CAT 6 Matrix with IR Return Control. Operation Manual CMLUX-4H4CAT

SY-HDBT-SLIM-100S Extender Set

SCART COMMANDER. Channels 2 audio channels 4 video channels 2 digital channels 2 control channels (pin 8 & 16)

Application Note M7L VideoPad-AV Installation Setup (software 9.1 onwards)

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

TV CHANNEL INSTALLATION

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

UNFOLD THE BASE. Quick Start Guide CONTENTS INSTALLING LCD TV ON THE WALL

CSC PC/Video/HD to HDMI 1.3 Switcher Operation Manual. Operation Manual CSC-5300

CS-802D HD High Resolution Scaler

EL-5500 Advanced HDMI/VGA Presentation Switch OPERATION MANUAL

User Manual DV-HDSS-41-TX. 4x1 4K Scaling Presentation Switcher with Dual Outputs. NOTE: See FSR LIT1628 API manual for serial commands.

VIDEO ALARM VERIFICATION UNIT VIVER

PLEASE READ THIS PRODUCT MANUAL CAREFULLY BEFORE USING THIS PRODUCT.

Transcription:

of of M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03

Attention Software Update After updating the M203 firmware to version 2.00 or higher, we recommend completely resetting the M203 interface by pressing the Disable softkey on setup page #2 for several seconds, until setup page #1 automatically appears. Please refer also to page 19 ff. 1

Table of Contents Attention Software update Table of contents M203 interface New features from software V 2.00 Switching between stations Installation and Connection Plan Connection M51 Link IN M51 Link OUT RS 232 IR-LINK Setup key Slot selection Serial Port Mode Serial Interface RS-232 Link RS-232 Filtered Video Controller Connection plan Pioneer Controller with M51 Pioneer Controller with M219 Gefen HDMI Switcher with M51 / M219 Setup # 1 Select Device Auto Standby Overview video products Gefen HDMI-Switcher 4x1/ 4x2 Gefen HDMI-Switcher 6x2 Pioneer models Setup # 2 AV Assignment Unknown audio sources 1. Selecting audio source 2. Assigning video input Disable Setup #2 Reset Technical data Guarantee Included in delivery 1 2 3 3 4 5 6 6 6 7 7 8 9 10 10 10 10 11 12 12 12 13+14 15 15 15 16 17 17 18-20 21 21 21 22 23 23 24 24 24 2

M203 Pioneer With the M203 Pioneer, Revox offers an interface, for the intelligent control of the most widely used Pioneer plasma and LCD devices*. The correct picture input is automatically selected at the television with the help of the interface. Additionally, the next or previous TV programme can be selected for the television, through the M218 wall-mounted keypad. *Please observe the system requirements New Multiroom Planer V2.00 The new Multiroom Planner doesn't just calculate the correct address assignment for the M219 Side room amplifiers and M217 Wall-mounted displays, it also calculates the slot addresses for the M203 series Re:control products in the side room. Take advantage of the possibility to be able to determine in advance, all M203, M217 and M219 addresses simply and quickly and at the same time save the information as system documentation. You will find more information about addressing the M203 in the side room, on Page 10 of this manual. You can download the new Multiroom Planner V2.00 free-ofcharge from the download area of the Revox Homepage, under www.revox.com. New features from software V2.00 From software version 2.00, the M203 can be connected not only to an M51 but also to the M219 Side room amplifier. As a result, a Pioneer television can also be controlled from an side room, using the M219 Side room amplifier. The option of connecting an M203 interface to an M219 exists with the first four Side room amplifiers for each zone. As a result, a total of 16 Side room amplifiers can be connected with an M203 interface in a Revox Multiroom system with 4 different zones. In the same way as with the setup of an M51, you define which video input at the Pioneer plasma TV is activated by which M219 audio source, through the M203 Setup module. The local inputs Local 1 3 at the M219 can be used for the control, as well as the audio sources of the Multiroom Central unit. Important advice: If you want to use the software version 2.00, the complete Revox system must be updated to the level 2.00, or higher. 3

Switching between stations using the Revox wall-mounted keypad The M203 offers the option of selecting specific stations using the skip keys (<>) on an M218 wall-mounted keypad, once the TV tuner has been selected. This comfort function requires two settings: Note: Monitor-only devices This comfort function is only available with TV models with an integrated TV tuner. It cannot be selected in case of monitor-only devices without a TV tuner. 1/2 Audio IN assignment M51 in combination with M203 The sound input, e.g. TV, Aux1, Optical, etc., of the remote device must be assigned to one of the following Remote buttons in the Remote menu: Local Local 1 Local 2 Local 3 Assignment example M219 in combination with M203 There is no need to make an assignment through the Remote menu with an M219, because its local audio inputs (Local 1-3) are always assigned to the IR commands Local, Local 1, Local 2 and Local 3. Continue with point 2/2 2/2 TV Tuner assignment M203 Setup #2 - Input The second assignment affects Setup #2 in the M203. Here, the physical audio source of the TV sound that was assigned to a Local Remote button in the first step, is assigned to the television's TV Tuner. In the example above, the audio source TV calls the television tuner. As well as the Multiroom central unit sources, a side room amplifier also offers its own local Inputs 1-3 for the TV Tuner assignment. 4

Installation The M203 interface can be installed easily and quickly. There are two types of fixing available. 1) The four outside fixing holes are used for a permanent installation. 2) Revox recommends using the two slots on the side for a variable installation. Connection plan Re:system (M51) resp. Further products: M201, M202, etc IR-/ wall-mounted remote control M204/ M218 RS232 seriell interface Fixing hole 4,2 mm Slotted hole 4 x 20 mm / 15 mm Setup button 5

Connection: M203 with M51/ M219 Socket: M51 LINK IN The M203 interface is connected with the M51 LINK socket on the back of the M51 or the M219 LINK socket on the Additional room amplifier, using the supplied telephone cable. If you want to use a different cable, you should only use a non-crossed, 4-core telephone cable with an RJ11 plug (6P4C modular). Connection: M203 with external interfaces Socket: M51 LINK OUT The M203 interface is designed for the connection of further external interfaces: M51 operation In the case of the M51, this can, for example be the M200 Domotic interface, the M201 IR interface, the M202 Ethernet interface or simply a further M203. Max. cable length: 100 m Max. cable resistance: 0.1 Ω /m M219 operation With the M219, the LINK OUT can be used for the connection of an M217 Display. Use a non-crossed, 4-core telephone cable with an RJ11 plug (6P4C modular). Max. cable length: 100 m Max. cable resistance: 0.1 Ω /m 6

Connection: M203 with seriell interface Socket: RS232 The M203 Interface can be used with other (TV) devices, which also have a serial interface. This enables the integration of a large number of Pioneer televisions into the Revox World. Which models are supported and how the integration is achieved described, starting from page 8. The M203 Interface is also suitable as an interface to domestic facility management systems such as AMX or Crestron, which have a special Revox protocol. Even a Windows PC with the M230 control program can be connected to the serial interface on the M203. Serial cables with a maximum length of 10 metres can be used. Connection: M203 with IR controller Socket: IR- LINK The connection to an IR receiver or a wall-mounted remote control is done through the 3-pin, screwfixable Phoenix plug connection. Revox recommends the use of a 2-core screened cable (microphone cable), where the screening is used as ground. This cable may be a maximum of 30 metres in length. Please ensure that you use the correct polarity when setting up as otherwise you might damage your equipment. Symbols: + Pos. voltage. 12-20V (DC) IN IR Signal - Ground The maximum number of IR receivers that can be switched in parallel per M203 is 3. 7

Setup key M51 Slot Selection Using the Setup key, you call up the M203 menu, which is shown in the M51 display. If the M203 interface is connected with an M219 Additional room amplifier, the M51 display is also used. In the case of an M10 installation, display is done using the M230 service program or M-Scope. M51 operation (fig. page 12) A different address must be assigned through the slot address, if a second M203 (M200) is connected to the M51 Link output, so that both don t occupy the same slot address. This would cause errors. In the case of a double address assignment, neither of the two M203s (M200s) would be shown in the Version list. Slot address: #11 or #12 Using the Softkeys you can get to pages #1 and #2 The two slot addresses 11 and 12 are available for selection. The following message appears if the selected address is already assigned: 8

M219 slot selection M219 operation (fig. page 13) In respect of the M219, the slot address defines the assignment to the Additional room amplifier. A M203 can only be connected to an Additional room amplifier within the address range 1 4. In Figure A, an M203 could be connected to each of the Additional room amplifiers 31 34. The M219 amplifiers 35 and 38 on the other hand may not be connected with an M203 interface. The slot address defines which Additional room amplifier the M203 interface should communicate with. This is necessary because of the bus system, although in each case, the M203 is individually connected with the M219. Only one M203 interface can be used per Additional room amplifier. Address assignment: x 1 x 11 x 2 x 12 x 3 x 13 x 4 x 14 x 5 x 6 x 7 x 8 Fig A. Multiroom version list / Zone 3 The figure below shows the Multiroom version list from Zone 3 for the M203 interfaces. You get to this menu by repeatedly pressing the Zone softkey in the sub-menu of: Setup Multiroom Version In this case, an M203 interface was assigned to the Additional room amplifier with address 4, through the slot address 314. Amplifiers 1 3 do not have an M203. x 1 x 4: x 5 x 8: x 11 x 14: only M219 M217 or M219 only M203 Fig B. Multiroom version list / Zone 3 9

Serial Port Mode Important Note: Reset The function of the serial interface (Serial Port) can be configured for the following applications: RS-232 Link RS-232 Filtered Gefen HDMI Switcher 4x2, 4x1 Gefen HDMI Switcher 6x2 Pioneer PDP 5000 EX Pioneer PDP 506 FDE Pioneer PDP 506 XDE - Cable Pioneer PDP 506 XDE - DVBT Pioneer PDP 507 XA Pioneer PDP 507 XD Pioneer PDP 508 XD Pioneer PDP 607 XD Pioneer PDP 60 MXE20 Pioneer PDP 615 EX Pioneer PDP LX5090H Pioneer PDP LX5090 Pioneer LCD KRL-32V Pioneer LCD KRL-37V Pioneer LCD KRL-46V Pioneer KRP 500A* Pioneer KRP 600A* You should always carry out a complete reset with each new configuration as well as when changing to another TV or HDMI switcher model. To do this, press the Disable softkey on Setup page #2 and keep it pressed, until the system automatically returns you to page 1. * with setting PDP LX5090 H 10

Serial Interface RS-232 Link. Standardised serial interface (RS232 protocol) for connection to a PC or another serial interface. RS-232 Filtered. Data-reduced RS232 protocol. Only M51-specific data is transferred, so-called display and broadcast messages. Application: You should select this setting if you want to use the M230 control program for PCs or if you want to access the Revox System through domestic facility management equipment such as Crestron and AMX. Application: Simple controllers with low data traffic requirements. 11

Video Controller. If a video controller for a plasma TV was selected on page #1 Port Mode, a second menu page, Setup # 2 is available. This page enables you to selectively switch on and/or between video inputs on a Pioneer plasma TV or an HDMI Switcher from the Gefen company, dependant on the selected M51/ M219 source. The convenient integration can of course also be used for the M51 s integrated DVD player. In this case, you only need to establish a video connection between the M51 and the TV. Please refer to the picture on the next page Connection : Video 1). Complete reset? Example for M51: A SAT receiver can conveniently be integrated through the automatic selection of the video input on the TV by the M51. Its picture output is connected, for example, to the S-Video input on the plasma TV, while the audio signal is connected to the Optical digital input on the M51. Please also refer to the picture on the next page. If you now select the source SAT (Optical) at the M51, the plasma TV automatically transmits the SAT receiver picture over the S-Video input and the sound from the SAT receiver is transmitted over the M51. Yes You should always carry out a complete reset with each new configuration as well as when changing to another TV model. To do this, press the Disable softkey on Setup page #2 and keep it pressed, until the system automatically returns you to page 1. No A complete reset is not necessary with an assignment change within a TV model. 12

Connection plan: Pioneer controller A with M51 Connection plan: Pioneer controller with M219 13

Connection plan: HDMI switcher with M51 14

Connection A plan: HDMI switcher with M219 Note The HDMI output on the M51 is only available if the DVS module is installed Gefen : Registered trademark of the Gefen Company/ US 15

Setup #1 Select device Auto Standby Using the softkeys Port Mode ± on page 1, select the TV model or the HDMI Switcher that you want to control through the RS232 interface. The Auto Standby function enables the Plasma TV to remain switched on, even in the case of selected audio sources that do not activate a video input at the Plasma TV, e.g. the M51 radio tuner. You will find an exact description of the individual products and their specific cabling, starting from page 10. When you select a video device, the menu point Auto Standby appears automatically. This is described in the following section. On the other hand, this menu point does not appear in Serial Port Mode RS232 Link and RS232 Filtered, because it is only used to control video devices. Auto Standby: ON The Plasma TV switches itself off automatically as soon as an audio source is selected, which either cannot activate a Plasma input, e.g. Tuner, or which is disabled. Auto Standby: OFF After the Plasma TV has been switched on, it remains on permanently until the M51/ M219 is switched off, irrespective of which audio source is selected. 16

Gefen HDMI Switcher 4x2, 4x1 Switcher 6x2 Control software for the HDMI Switcher from the Gefen Company (www.gefen.com) The HDMI inputs on the HDMI switcher are activated, dependant on the M51/ M219 source. If there is no assignment, the HDMI input that was last selected remains active. Setting is done on page #5 in the M200 Setup Product features: - 4 HDMI inputs (4x1,4x2) - 6 HDMI inputs (6x2) - 1 HDMI outputs (4x1) - 2 HDMI outputs (4x2), whereby both outputs can be operated in parallel - Resolution up to 1080p - HDCP-enabled - Optical audio digital output 9-Pol 9-Pol Pin 2 Pin 3 Pin 3 Pin 2 Pin 5 Pin 5 Max. cable length RS232: 10 m Gefen products are freely available through specialist retail outlets. A crossed Sub-D cable (plug plug) is required for the transmission. Type: Plug-Plug For this reason, you should use the enclosed crossover adapter and gender adapter with the supplied Revox cable. + 17

Pioneer Models: PDP 5000 EX PDP 506 FDE PDP 506 XDE-C PDP 506 XDE-DVBT PDP 507 XA/ XD PDP 508 XD PDP 607 XD PDP LX5090 H PDP LX5090 KRP 500A* KRP 600A* Pioneer Models: PDP 615 EX PDP 60 MXE20 LCD KRL-32V LCD KRL-37V LCD KRL-46V The models listed above require a crossover serial cable, also known as a null modem cable, as the control cable between the M203 and the Pioneer TV. Connection type: Plug - Socket For this reason, you should use the enclosed crossover adapter with the supplied Revox 1:1 cable The models listed above require a normal serial 1:1 cable, as the control cable between the M203 and the television. Connection type: Plug - Socket The supplied Revox 1:1 cable conforms to this configuration and can be used directly, without an adapter. 9-Pol 9-Pol Pin 5 Pin 5 Pin 2 Pin 3 Pin 3 Pin 2 9-Pol 9-Pol Pin 5 Pin 5 Pin 2 Pin 2 Pin 3 Pin 3 Max. cable length RS232: 10 m Max. cable length RS232: 10 m * with setting PDP LX5090 H 18

Activating the Pioneer RS232 interface - PLASMA Models: PDP 506 / PDP 507 The RS232 interface must be activated in the Integrator menu, so that these Pioneer models can receive the commands from M203 Pioneer. Please take note of the sequence of activation on the RS232 mode. Under certain circumstances, the Integrator menu doesn t appear the first time. If this happens, please repeat the process. 1) Switch on / switch over the plasma television to TV mode 2) Place the plasma television in standby mode 3) Press and release the i+ (INFO) button on the Pioneer remote control. [Point 3 is not always necessary. It depends on the manufacturing date of the Pioneer Plasma] 4) Press and release the HOME MENU button on the Pioneer remote control. 5) Follow this without delay, by pressing and releasing the (Power) button 6) Deactivate the SR+ mode in the Integrator menu that now appears. This activates the RS232 mode at the same time 7) Confirm the change by pressing the HOME MENU button 8) Switch the device off and restart Model: PDP 508 The PDP 508 model does not have an explicit SR+ mode within the Integrator menu. In fact, the baud rate of the Pioneer interface can be set through the Integrator menu. The baud rate should be set to 9600 for communication with the M203. Model: PDP 5000EX With the PDP 5000 EX, the RS232 interface is activated in the normal user menu (HOME MENU Setup SR+). Models: PDP 615EX / PDP 60MXE / PDP LX 5090 H PDP LX 5090 / KRP 500A / KRP 600A With these models, the RS232 interface is already activated. No further activation settings are required. 19

Activating the Pioneer RS232 interface LCD Models: LCD KRL-xxV Following the initial commissioning of a Pioneer LCD television, its serial interface (RS232) is not yet configured for control by an external device, like the M203 Pioneer in our case. The RS232 interface is only permanently activated once a one-off initialisation command is sent through the M203 interface to the LCD television. Activation is done with the following steps: 1) Carry out a complete reset (see Page 12) 2) Make the settings as described in "Setup #2 AV Assignment", from Page 21. 3) Switch on the M51/M219 with FM Tuner. If no FM Tuner is installed, select a source that is not linked to a television video input in Setup #2. 4) Switch on the LCD television with the original remote control, using the Power button. 5) Wait until the television is ready to receive. 6) Now select a source at the M51 (or at the M219 Side room amplifier), which is linked to a television video input in Setup #2. 7) The LCD television is now initialised and retains the facility to be controlled through the serial interface, even when it is switched off. Please note: If the television is changed, the process described above has to be repeated. Pioneer LCD special characteristic The LCD inputs Input 3 and Input 8 can only be addressed by the M203 if there is already a signal at its input. If this is not the case, the LCD television recognises this and ignores the control command. 20

Setup #2 AV Assignment Unknown audio sources 1. Selecting audio source "Sources unknown" can still be present during the initial configuration, caused by the swap or the de-installation of modules. To start with, select the M51 / M219 audio source that later should activate a particular video input on the Pioneer television/ HDMI Switcher, using the Source ± softkey. Following switch-on, it can take a few seconds until the M203 interface has identified all the M51 / M219 sources and until the "Source Unknown" message disappears. Any remaining unknown sources should be deleted by pressing the Disable softkey twice and then pressing the Delete softkey. If too many unknown sources are present, we recommend completely resetting the M203 interface by pressing the Disable softkey for several seconds, until Page #1 automatically appears. Assignment example Using the Source+ and Sourcesoftkeys, you can step forwards and backwards respectively, through a loop of audio inputs, which are currently available on the M51 / M219. If the name of an audio source has been changed, the modified name also appears in the list. An Unknown Source must be deleted manually. You will find more information about this in the previous section. 21

2. Assigning video inputs In the second step, a video input from the television / HDMI Switcher is assigned to the selected M51/ M219 audio source, using the Input ± softkey. Using the Input ± softkey, you can step through a loop of video inputs that are available to the television. The softkey Store appears as confirmation each time the Input is changed. Press Store if you want to save your changes. Otherwise the original setting is retained. The following display appears, if a video input is called by one or more audio sources: As the televisions that can be selected from have different video inputs, only those video inputs that the corresponding TV device has, are actually displayed. e.g.: S-Video RGB YUV VGA Assignment example This example shows you that, as well as the currently displayed audio source (DVD), a further audio source has also been assigned to this video input (here CVBS). Using the Source ± softkeys, you can search for the audio source that also calls this video input. Several audio sources are always required if, for example, the M300/M301 Video switch is used, which bundles several video sources together to one video input on the television. 22

Disable Setup #2 Reset Using the Disable function, you can undo or disable the assignment of an audio source to a video input. If you want to return the settings in Setup #2 menu to the factory settings, simply press and hold the Disable softkey until the Setup- #1 page appears again. To do this, select the required audio input using the Source ± softkeys and then press the Disable softkey. The Store softkey then appears that you need to press to confirm your change. This resets all input assignments and restores the factory settings. If you don t press Store, the original setting is retained. 23

Technical data IR-LINK: + Positive voltage 10-20V (DC) IN IR signal - Ground (GND) Dimensions: 113 x 25 x 50 mm (WxHxD) Weight: 150 g Power consumption: 35 ma (without IR receiver) Max. cable length: 100 m (M203- M51/ M219) Max. cable length: 30 m (M203 - IR receiver) E & OE Product subject to technical modifications. Guarantee The guarantee period is 24 months from the date of purchase. Your dealer should be your first contact if you need service. If he can't give you the help you need, send your M203 interface carriage free and without any accessories to your national Sales Office. Please supply a complete description of the problem and a full return postal address. Included in delivery M203 Pioneer interface Link cable ( 2 m ) Serial PC cable (1:1 - length 3 m) (Plug-Socket) Crossover adapter Gender adapter Manual 24

GERMANY Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen Telefon +49 7721 8704 0, Fax +49 7721 8704 29 info@revox.de, www.revox.de SCHWEIZ Revox Schweiz AG, Wehntalerstrasse 190, CH-8105 Regensdorf Telefon +41 44 871 66 11, Fax +41 44 871 66 19 info@revox.ch, www.revox.ch Zentralservice Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen Telefon +49 7721 8704 43, Fax +49 7721 8704 49 info@revox.de Manual M203 Pioneer interface / Part no.: 10.30.3074 25