Ali Ghiasi. Nov 8, 2011 IEEE GNGOPTX Study Group Atlanta

Similar documents
Application Space of CAUI-4/ OIF-VSR and cppi-4

Ali Ghiasi. Jan 23, 2011 IEEE GNGOPTX Study Group Newport Beach

CAUI-4 Application Requirements

CAUI-4 Chip to Chip and Chip to Module Applications

CAUI-4 Chip to Chip Simulations

System Evolution with 100G Serial IO

Architectural Consideration for 100 Gb/s/lane Systems

Validation of VSR Module to Host link

Measurements and Simulation Results in Support of IEEE 802.3bj Objective

Measurements Results of GBd VCSEL Over OM3 with and without Equalization

XLAUI/CAUI Electrical Specifications

40G SWDM4 MSA Technical Specifications Optical Specifications

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

CDAUI-8 Chip-to-Module (C2M) System Analysis #3. Ben Smith and Stephane Dallaire, Inphi Corporation IEEE 802.3bs, Bonita Springs, September 2015

500 m SMF Objective Baseline Proposal

40G SWDM4 MSA Technical Specifications Optical Specifications

Architectural Considera1on for 100 Gb/s/lane Systems

Thoughts about adaptive transmitter FFE for 802.3ck Chip-to-Module. Adee Ran, Intel Phil Sun, Credo Adam Healey, Broadcom

Summary of NRZ CDAUI proposals

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

100GEL C2M Channel Reach Update

Practical Receiver Equalization Tradeoffs Applicable to Next- Generation 28 Gb/s Links with db Loss Channels

100G EDR and QSFP+ Cable Test Solutions

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

50 Gb/s per lane MMF objectives. IEEE 50G & NGOATH Study Group January 2016, Atlanta, GA Jonathan King, Finisar

Approach For Supporting Legacy Channels Per IEEE 802.3bj Objective

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

Comparison of NRZ, PR-2, and PR-4 signaling. Qasim Chaudry Adam Healey Greg Sheets

CDAUI-8 Chip-to-Module (C2M) System Analysis. Stephane Dallaire and Ben Smith, September 2, 2015

Need for FEC-protected chip-to-module CAUI-4 specification. Piers Dawe Mellanox Technologies

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

10GBASE-LRM Interoperability & Technical Feasibility Report

M809256PA OIF-CEI CEI-56G Pre-Compliance Receiver Test Application

MR Interface Analysis including Chord Signaling Options

100GBASE-FR2, -LR2 Baseline Proposal

40GBASE-ER4 optical budget

100G-FR and 100G-LR Technical Specifications

PRE-QSFP-LR4L 100G QSFP 28 Dual Range Optical Transceiver, 10km. Product Features: General Product Description:

Brian Holden Kandou Bus, S.A. IEEE GE Study Group September 2, 2013 York, United Kingdom

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

Product Specification 10km Multi-rate 100G QSFP28 Optical Transceiver Module FTLC1151SDPL

40GBd QSFP+ SR4 Transceiver

Comparison of options for 40 Gb/s PMD for 10 km duplex SMF and recommendations

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

100G CWDM Link Model for DM DFB Lasers. John Petrilla: Avago Technologies May 2013

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

COM Study for db Channels of CAUI-4 Chip-to-Chip Link

100G PSM4 & RS(528, 514, 7, 10) FEC. John Petrilla: Avago Technologies September 2012

Performance comparison study for Rx vs Tx based equalization for C2M links

10Gbps SFP+ Optical Transceiver, 10km Reach

Thoughts on 25G cable/host configurations. Mike Dudek QLogic. 11/18/14 Presented to 25GE architecture ad hoc 11/19/14.

Simulations of Duobinary and NRZ Over Selected IEEE Channels (Including Jitter and Crosstalk)

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

400G-FR4 Technical Specification

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

Ver.0.3 Sept NTC2-HFER-3SOH. 100Gbps CFP2 Transceiver 1/7. 100Gb/s CFP2 Optical Transceiver Module. Feature. Application

PAM8 Baseline Proposal

100Gb/s Single-lane SERDES Discussion. Phil Sun, Credo Semiconductor IEEE New Ethernet Applications Ad Hoc May 24, 2017

100G QSFP28 SR4 Transceiver

An Approach To 25GbE SMF 10km Specification IEEE Plenary (Macau) Kohichi Tamura

50 Gb/s per lane MMF baseline proposals. P802.3cd, Whistler, BC 21 st May 2016 Jonathan King, Finisar Jonathan Ingham, FIT

Optical transmission feasibility for 400GbE extended reach PMD. Yoshiaki Sone NTT IEEE802.3 Industry Connections NG-ECDC Ad hoc, Whistler, May 2016

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

The Case of the Closing Eyes: Is PAM the Answer? Is NRZ dead?

Product Specification 56Gbps 60/100m QSFP+ Optical Transceiver Module FTL414QB2C APPLICATIONS

Further information on PAM4 error performance and power budget considerations

Product Specification 100m Multirate Parallel MMF 100/128G QSFP28 Optical Transceiver FTLC9551SEPM

Transmitter Specifications and COM for 50GBASE-CR Mike Dudek Cavium Tao Hu Cavium cd Ad-hoc 1/10/18.

Product Specification 40BASE-SR4 QSFP+ Gen3 Optical Transceiver Module FTL410QE3C

Open electrical issues. Piers Dawe Mellanox

32 G/64 Gbaud Multi Channel PAM4 BERT

DataCom: Practical PAM4 Test Methods for Electrical CDAUI8/VSR-PAM4, Optical 400G-BASE LR8/FR8/DR4

CFPQD010C10D CFP Dual Fibre 1310nm* / 10km / 100GBASE-LR4 & OTN OTU4

PAM4 signals for 400 Gbps: acquisition for measurement and signal processing

Investigation of PAM-4/6/8 Signaling and FEC for 100 Gb/s Serial Transmission

Maps of OMA, TDP and mean power. Piers Dawe Mellanox Technologies

Further Clarification of FEC Performance over PAM4 links with Bit-multiplexing

D1.2 Comments Discussion Document. Chris DiMinico MC Communications/ LEONI Cables & Systems

QSFP28 Series Preliminary. EOLQ-161HG-20-LA2 Series. Features. Applications. Ordering Information

QSFP SV-QSFP-40G-PSR4

Transmitter Preemphasis: An Easier Path to 99% Coverage at 300m?

QSFP-100G-LR4-AR-LEG. 100Gbase-LR4 QSFP28 Transceiver

Product Specification 40BASE-SR4 100m QSFP+ Gen2 Optical Transceiver Module FTL410QE2C

Investigation of PAM-4/6/8 Signaling and FEC for 100 Gb/s Serial Transmission

Clause 74 FEC and MLD Interactions. Magesh Valliappan Broadcom Mark Gustlin - Cisco

Improved extinction ratio specifications. Piers Dawe Mellanox

PAM-2 on a 1 Meter Backplane Channel

Technical Feasibility of Single Wavelength 400GbE 2km &10km application

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Further Investigation of Bit Multiplexing in 400GbE PMA

100Gb/s QSFP28 ER4 Lite Optical Transceiver DC-FC31C-40. Product Specification

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

QSFP+ 40GBASE-LR4 Fiber Transceiver

EVLA Fiber Selection Critical Design Review

New Serial Link Simulation Process, 6 Gbps SAS Case Study

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

10Gbps 10km Range SFP+ Optical Transceiver

Practical De-embedding for Gigabit fixture. Ben Chia Senior Signal Integrity Consultant 5/17/2011

Exceeding the Limits of Binary Data Transmission on Printed Circuit Boards by Multilevel Signaling

Transcription:

Ali Ghiasi Nov 8, 2011 IEEE 802.3 100GNGOPTX Study Group Atlanta 1

Overview I/O Trend Line card implementations VSR/CAUI-4 application model cppi-4 application model VSR loss budget Possible CAUI-4 loss budget cppi-4 simulations and measurements Measurements result of 100G-LR4 link operating unretime Credits TE formally known (Tyco Electronics) for providing test board and connector models Finisar corporation for joint 100Gbase-LR4 testing but Finisar corporation has no specific position on the content of this presentation. 2

100GbE I/O Trends ASIC I/O Technology 10x10G CAUI ASIC I/O Technology 28G-VSR/SR CFP / CXP Module I/O Technology 10x10G CAUI (CFP) 10x10G cppi (CXP) CFP2 (4x25G) I/O Technology 28G-VSR CFP4/QSFP+ (4x25G) I/O Technology 25G: cppi-4 IEEE Standards 100G: LR4/ER4/SR10/ CR10 CAUI, cppi OIF 100G: 28G-VSR IEEE Standards 100GCU: KR4/CR4 IEEE Standards 100G: cppi-4/caui-4 FR4/SR4 IEEE Standards 400GbE Gearbox/Mux/De-mux Retimed Unretimed 2008 2010 2012 2014 3

Typical Line Card on a Scalable System Requirement to simultaneously drive the backplane increases the distance to front panel ports Line card chip to chip application require at least 15 of PCB with one connector which is inline with OIF-28G-SR 8 KR4 KR4 Switch Switch Switch 15 Switch 16 15 18 Switch Switch Switch 6 Switch 10 2 PB PB PB PB PB PB PB PB * PB is port buffer and may contain one or more of the following memory, MACSec, Time stamp, etc. 4

Typical Top of the Rack Switch Top of the rack switch aggregate server uplinks operating at 100G If single ASIC was driving all front panel ports 12 host PCB is required and roles out Cu cabling Alternative approach is to use external retimer when needed at external 8 retimers and support 40G/100G Cu cabling 8 8 Switch 12 Switch 10 2 R* R R 4 R R * R is retimer 5

Current Retimed Applications with CFP2 CFP2 is retimed interfaced designed for LR4/ER4 but could be retrofitted to support 100G-CR4/SR4 as well OIF 28G-VSR only supports 4-6 of PCB and not sufficient for general CAUI chip to chip application where OIF 28G-SR is currently targeted 100GbE Switch, Packet Processor or ASIC CAUI 200-300 mm CAUI Gearbox Gearbox 28G-VSR/ CAUI-4 100-150 mm 28G-VSR/ CAUI-4 100GbE Retimer 100GbE Retimer 100GbE Retimer 100GbE Retimer CFP2/CFP4 Module <25 mm LR4 / ER4 Tx LR4 / ER4 Rx QSFP2/CFP4 100G-CR4 100-150 mm 200-300 mm 6

Possible Applications of CFP2 The 200-300 mm host PCB with one connector would be required Can VSR 10 loss budget enhanced without substantial power increase A retime module to ASIC interface need to support 300 mm of host and would not be compatible with current retime interface OIF-28G-VSR Application model not compatible with passive Cu! CFP2/CFP4 Module 100GbE Switch, Packet Processor or ASIC CAUI-4? 300 mm CAUI-4? 300 mm 100GbE Retimer 100GbE Retimer 100GbE Retimer 100GbE Retimer <25 mm LR4 / ER4 Tx LR4 / ER4 Rx QSFP+ 100G-CR4 7

Next Generation Implementation Based on cppi-4 cppi-4 is unretimed interfaced will be designed to support LR4/ER4 as well as new PMD s in development 100G-CR4/SR4 The 200-300 mm is more inline with OIF 28G-SR, can we retrofit OIF VSR to meet CAUI-4 chip to chip application as well? 100GbE Switch, Packet Processor or ASIC 200-300 mm 200-300 mm CAUI-4? CAUI-4? Retimer Retimer 50-100 mm cppi-4 50-100 mm cppi-4 CFP4/QSFP+ Module LR4 / ER4 Tx LR4 / ER4 Rx CFP4/QSFP+ Module 100G-CR4 8

The Crystal Ball is not so clear! VSR already has defined a retiemd 10 db interfaced VSR could be enhanced to about 12 db and still be compatible To support retime back to one large ASIC or chip to chip applications an OIF 28G-SR loss budget (15.4 db) is needed For a pluggable non-engineered link CTLE receiver is not sufficient! OIF VSR was created because OIF-SR was too high a power Host Trace Length * Total Loss (db) Host Loss(dB) FR4-6 N4000-13 N4000-13SI Megtron 6 Nominal PCB Loss at 28G/in N/A N/A 2.0 1.5 1.2 0.9 OIF 28G-LR with two connector 25.5 23.1 11.6 15.4 19.3 25.7 OIF 28G-SR with one connector & HCB 15.4 12.5 6.3 8.3 10.4 13.9 OIF 28G-VSR with one connector & HCB 10 7.1 3.6 4.7 5.9 7.9 cppi-4 with one connector & HCB 7 4.1 2.1 2.7 3.4 4.6 * Assumes connector loss is 1.2 db and HCB loss is 1.7 db. 9

Highlight of OIF 28G-VSR Host transmitter assumes 3 tap FFE with pre and post Transmit amplitude of 600 mv Host output measured at HCB output with reference CTLE and must meet certain vertical and horizontal opening Module transmitter assumes it will deliver certain vertical and horizontal opening at MCB output Assume sensitivity at chip ball is 100 mv when measured with software CTLE There is no back channel Host will optimize far end eye through reference CTLE by adjusting pre and post The module will utilize its pre/post or peaking filter and faster rise time to deliver min vertical and horizontal opening at TP4 (MCB Output) Specification assumes MCB and HCB similar to 802.3ba Good starting point for CAUI-4 and it can be tweaked to better fit Ethernet applications. 10

OIF 28G-VSR Architecture and Reference Points Follows 802.3 CL83B (CAUI) Connector Up to 1.2 db Host PCB Budget 7.1 db Mod PCB +Cap 1.5 db A Driver VSR Host IC Receiver D B C B C Receiver VSR Module IC Driver Chip Compliance Point 1.25 db@14ghz Module Compliance Point Propose 1.25 db@14ghz Host Compliance Point Propose 1.7 db@14ghz 11

VSR Channel Loss Budget Table Assumes 10 db loss from host IC balls to module IC balls If the CPPI-4 loss budget is in the 12 db range a level of compatibility with VSR could be achieved With 12 loss budget 9 host PCB is possible on Meg 6 Traces FR4-6 N4000-13 N4000-13SI Megtron 6 Loss at 14 GHz /in 2.0 1.5 1.2 0.9 Worst Case Connector loss at 14 GHz Loss allocation for 2 Vias in the channel DC Block Max Module PCB Loss 1.2 0.5 0.5 1.7 Host PCB Trace Length Assuming 10 db Loss Budget 3.0500 4.0667 5.0833 6.7778 Host PCB Trace Length Assuming 12 db Loss Budget 4.0500 5.4000 6.7500 9.0000 12

How To Increase OIF VSR Loss Budget Transmitter TP1a (Host Output) Transmit output is measured with 0-8 db CTLE requiring 100 mv post EQ eye height Minimum transmit amplitude is 600 mv Increasing transmit amplitude, reducing jitter, or reducing rise time can deliver the same eye opening across 12 db channel Further increase would require adding more equalization to the module or possibly increasing sensitivity from 100 mv to 75 mv which will result incompatible interface Receive TP4a (Module Output) Current OIF test method only require near end testing with small value of CTLE gain 1 or 2 db There is trivial option to extend the VSR reach assuming just compliant module The most straight forward way would be design the host PCB based on the capability of the receiver, since this is done at design phase it will be interoperable with all VSR modules 13

Target CAUI-4 Channel VSR loss can be extended for CAUI-4 to 12 db and have a level of compatibility Channel was based on measured 5 of FR4 370-HR stripline, with two vias, Quattro connector, and HCB VSR RL mask shown on the left diagram does not include host IC where the VSR mask include the host IC VSR Mask CAUI-4 Mask 14

OIF VSR Reference Receiver Is based on a family of 0-8 db CTLE having two poles and one zero Will also submit the same model to be posted under model/channel area 1.00E+00 1.00E+00 0.00E+00 0.00E+00-1.00E+00-1.00E+00-2.00E+00-2.00E+00-3.00E+00 7 db -3.00E+00 8 db -4.00E+00-5.00E+00 "5 db" "3 db" "1 db" -4.00E+00-5.00E+00 6 db 4 db 2 db -6.00E+00 0 db -6.00E+00 0 db -7.00E+00-7.00E+00-8.00E+00-8.00E+00-9.00E+00-9.00E+00-1.00E+01 0.1 1 10 100-1.00E+01 0.1 1 10 100 15

Far End Eye 12 db CAUI-4 Channel Just increasing TX amplitude to 800 mv with standard VSR near end jitter would fail the far end Far end equalized eye measured with OIF VSR CTLE Fails 16

Far End Eye 12 db CAUI-4 Channel Using 2 nd gen transmitter similar to cppi with 600 mv Alternatively a combination better transmitter and amplitude can be used Far end equalized measured with OIF VSR CTLE 17

cppi-4 Architecture and Reference Points Follows 802.3 CL86(nPPI) and CL85 Will be compatible with 100G-CR4 Driver VSR Host IC Receiver A D Host PCB Budget 4.1 db B C Connector Up to 1.2 db Mod PCB +Cap 1.7 db B C Receiver VSR Module IC Driver Chip Compliance Point 1.25 db@14ghz Module Compliance Point Propose 1.25 db@14ghz Host Compliance Point Propose 1.7 db@14ghz 18

cppi-4 Proposed Channel Loss Budget Attach cppi-4 with 7 db loss budget can support unretimed optical PMDs as well as100gcu copper cables Traces FR4-6 N4000-13 N4000-13SI Megtron 6 Nominal Loss at 14 GHz /in 2 1.5 1.2 0.9 Connector loss at 14 GHz* Loss allocation for 2 Vias in the channel Max Module PCB Loss/DC Blocks at 14GHz* 1.2 0.5 1.7 PCB Trace Length Assuming 7 db Loss Budget 1.8000 2.4000 3.0000 4.0000 * For 100 GbE operation since the HCB and connector are specified for operation up to 28GBd there will be 0.2-0.3 db unallocated margin. 19

cppi-4 Channel Based on TE Quattro II VSR mask also shown Host PCB Material =N4000-13SI Trace Length =4 Traces = 5 mils stripline Connector Quattro II Plug PCB Material =N4000-13SI Trace Length =1.5 Traces = 5 mils Microstrip 20

Far End Transmitter Eye Simulated and measured eye for 4 Quattro II Channel at 25.7 GBd Channel loss 7.1 db @14 GHz 21

Simulation Block Diagram Host Module to Host Channel based on s16p and includes worst case FEXT in the simulation 100Gbase-ER4 TP3 stress input with 3.5 db VECP VECP for 1310 nm FR4 PMD expected to be 1.5-2.5 db VECP for 850 nm SR4 PMD could be 3.5 db TP5 sensitivity with minimum optical receiver sensitivity 0.7 UI TJ at slicer and one with 0.65 UI at slicer A linear interface will relax the requirement of 0.7/0.65 UI jitter at 25G TP3 Stress Input 20 db LA ESD PKG Channel s16p ESD PKG Output XTALK Source 20 db LA ESD PKG FEXT 22

TP3 Stress Input Based on 100Gbase-ER4 definition which has higher 3.5 db VECP, J2=0.3 UI, J9=0.47 UI 23

Limiter Output For minimum required sensitivity and slightly better receiver with 0.4 UI opening at sampling point instead of 0.3 UI 24

75 mm cppi Like Channel Results at TP5 with 0.3 and 0.4 UI at sampling point Increasing sampling point by 0.1 db equates to ~2 db sensitivity increase 25

175 mm Channel Unretimed 175 mm channel with 0.3 and 0.4 UI at sampling point 26

100GBase-LR4 Stress Sensitivity Test Tested @25.78GHz Tyco HCB + Quattro-II connector + 4 Host PCB channel (IL 7dB @14G) BER tested with PRBS31 25G CDR 6 cable Tyco Quattro 4 Host 23GHz DC block 6 cable LR4 ROSA LR4 TP3 Stress Gen 27

LR4 ROSA Driving 4 TE Channel Real time scope results at -6 dbm AOP Unequalized Eye PN7 Equalized Eye 2 Taps DFE PN31 Equalized Eye 6dB CTLE/2 Taps DFE PN31 28

cppi-4 BER Measurements Test chip with CTLE shows about 4 db of optical penalty which is high Real time scope result with just 2 tap DFE looks promising and expect the penalty could be reduced to more reasonable level like 1-2 dbo 1.E-04 1.E-05 Finisar SRS L0 no SJ Finisar SRS L0 100K/5UI +5inch Tyco Finisar SRS L0 100K/5UI 1.E-06 1.E-07 BER 1.E-08 1.E-09 1.E-10 1.E-11 1.E-12 1.E-13-17 -16-15 -14-13 -12-11 -10-9 -8-7 -6 AOP (dbm) 29

Summary After investigating line card application space a retime space meeting majority of applications is in line with OIF 28G-SR with loss of 15.4 db OIF VSR was specifically created to lower the module PD with agreed loss of 10 db As identified here OIF VSR loss budget can be increased to 12 db for CAUI-4 and still maintain a level of compatibility Alternatively we can define a 10 db and 15.4 db chip to chip/module interface CAUI-4 must operate with BER 1E-12 or better without FEC as it must support existing PMDs such as LR4/ER4 FEC option must be combine with new PMDs such as 100G-SR4/nR4 100GNGTOPTX project needs to define retiemd interface as well as an investigate unretimed interface which is in sync with 100GCU project In 802.3ba retimed interfaces was defined in CL83A/83B and unretimed interfaces CL85 (CR4/CR10) and CL86 (nppi) were defined Simulation and measurements shown here indicate feasibility of unretime interface specially in case of new PMDs and with FEC But we have also shown feasibility of unretime with LR4. 30