DFT. Rotating Vane Flow Meter, Counter, Doser. for liquids l/min. Measuring accuracy: 2.5% f. s. : 16 bar; t max

Similar documents
DFT. Compact Paddle Flow Sensor

OVZ. Economical Oval-Gear Flow Meter. For Viscous Oils

Electronic Pulse Counter Combination device

DVZ. Compact Vortex Flowmeter. for Low Viscosity Liquids

Oscillation Flowmeter Model DOG-4

Speed sensor MiniCoder GEL 2471

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Arc Detecting and Protection System

Arc-fault Protection System

Single Point Flow Monitor SW118 SW119

Separate Thin Amplifier type. AP-V40AW Series

Bimetal Temperature Switch

Lt DELTA USA, Inc

Selection matrix for electronic pressure switches

PROPORTIONAL VALVES Sentronic plus

Mechanical flow switch for On/Off control

Multifunction devices

Installation Instructions. What This Option Provides

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Level Measurement silometer FMC 420, FMC 423

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Global pay TV revenues crawl to $200 billion

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Linear flow control with actuator IFC

2.9 Sigma/ 2 Plunger Metering Pumps

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES 400 SERIES 620

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

48x24. Options ORDER NUMBER OF TYPE PFL B

Sensor technologies Proximity sensors Series ST4. Brochure

Modular Lube Lubrication Systems System Controls

Interconnections. General characteristics. Plug

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Photoelectric Sensors E3F2

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Linear flow controls VFC Linear flow controls with actuator IFC

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

02/11/2015

Preset counters, electronic

W 9-2: A Versatile, Complete and Compact Series

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Hour Meters / Timers, electronic

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

IMPAC Infrared Thermometers

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

Micro-Machined Silicon Transducers

Pressure transmitter COMPACT IO-Link,

FLOMAT Electromagnetic Insertion Flowmeter

INNOVATION IN MAGNETICS DS3434/5. Mag612. Miniature Three-Axis Fluxgate Probe.

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

TUC: Universal thermostat

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Panel-mounting thermostats, type series EM

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Gear Pump Units For single-line centralized lubrication systems

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

100 : 1. Digital Flow Switch. PFMB Series 66 % 67% 76 % 81% 2-Color Display (Only 200 L type) Compact, Space saving

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Operating instructions Electronic preset counter Type series 717

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

APPLICATIONS. Automatic warehouse. Trasportation lines

Digital Flow Switch for Air/Water

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Digital Flow Switch for Large Flow

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Flow Switch. Flow Switch

BFI RESEARCH AND STATISTICS PUBLISHED AUGUST 2016 THE UK FILM MARKET AS A WHOLE. Image: Mr Holmes courtesy of eone Films

Pressure Sensors SPAB, with Display

263 Series LED Bargraph Indicator and Controllers

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

QUICK START GUIDE FLEXSLICE MODULES

DMP 331i / DMP 333i LMP 331 i

APPLICATIONS. Automatic warehouse. Trasportation lines

High performance circuit breakers

Innovation in Magnetic Field Measuring Instruments. Magnetometer Power Supplies

Process Transmitter RMA 422

Magnetic Sensor - Incremental EHP

NEW. Cable/Pipe sizes. InsertStrip. MainBlock

Solution Selection Guide

Magnetic Stirrers Magnetic Stirr

Time meter electronic

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Transcription:

Rotating Vane Flow Meter, Counter, Doser for liquids measuring monitoring analysing DFT OMeasuring O range: 0.2-2.0... 3-60 l/min OO Measuring accuracy: 2.5% f. s. OO p max : 16 bar; t max : 80 C OProcess O connection: G ¼, G ½, G ¾ female ¼" NPT, ½" NPT, ¾" NPT S4 OMaterials: O PTFE housing or brass housing KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.de@kobold.com www.kobold.com 1

Brass Housing PTFE Housing Working Method The established vane technology has proven itself a million times worldwide for measuring and monitoring the flow of different media through piping. KOBOLD flowmeters/monitors work with this proven principle and offer may benefits. The heart of the new KOBOLD vane is an embedded ring magnet; it is hermetically sealed from the flow medium. It transfers, in a non-contacting manner, the rotary motion of the vane to a Hall sensor attached to the case (in order to save space). This converts the rotary motion to a frequency signal that is proportional to the flow rate. The downstream KOBOLD evaluating electronics can output this signal to a display, convert it to (0(4) -20 ma, 0-10 V) analogue signal, or count it. It may also be used to switch up to two limit contacts. The ready and control states of the limit value relay are indicated by LEDs. The modular design of KOBOLD flow monitors and measuring instruments is a system that can be universally applied; it is reasonably priced; and requires minimum space when in service. Very precise measurement results can be achieved, under tough operating conditions along with the KOBOLD electronics. The system is assembled with the electronics and delivered ready for service. The electronics are adjusted and tuned for use with the sensor. When retrofitted for other measuring ranges, the system may be readjusted with a similar device at any time. Fields of Application The KOBOLD meters/monitors are suitable for the following applications: OOcooling water monitoring OOgeneral mechanical engineering OOwaste water treatment OOall heavy goods industry OOchemical industry Technical Details Sensor Measuring accuracy: 2.5% f. s. 5% f. s. (DFT-.. 0000) Medium temperature: -20...+80 C Ambient temperature: -20...+80 C Max. operating pressure: Max. pressure loss: Protection: IP 65 Materials: Housing/cover: Vane: Axle: Bearing: Gasket: 5 bar (PTFE housing) 16 bar (brass housing) see table PTFE or brass PTFE ceramics Al 2 O 3 or sapphire PTFE NBR (DFT-11..; DFT-16..) FEP-O-seal with silicone (DFT-13..; DFT-18..) Front- and back panel: aluminium, black anodised (DFT-13..; DFT-18.. only; not media-contacting) Screwing: stainless steel Electronics OOFrequency output (OEM) Power supply: 5-24 V DC approx. 5 ma Signal amplitude high: approx. power supply Signal amplitude low: 0.2 V Output loss: max. 2.5 mw Electrical connection: connector DIN 43650 Pulse output: NPN, open collector, max.15 ma OOFrequency output (option frequency divider) Power supply: 24 V DC ± 20% 40-50 ma Signal amplitude high: approx. power supply Signal amplitude low: 0.2 V Output loss: max. 2.5 mw Electrical connection: connector DIN 43650 Division factor (option): 0.25... 2 factory set Pulse output: PNP, open collector, max. 20 ma OOAnalogue output (L electronics) Power supply: 24 V DC ±20% Output: 0-20 ma or 4-20 ma, 3-wire or 2-wire (2-wire 4-20 ma only) Max. load: 500 Ω Electrical connection: connector DIN 43650 2 www.kobold.com

Technical Details (continued) OOAnalogue output (MA electronics) Power supply: 24 V DC +15% / -10% 24/115/230 V AC ±20% 3.5 W max. Output: Max. load: Electrical connection: 0(4)-20 ma or 0-10 V (floating, 24 V DC non-isolated) 500 Ω 1.5 m cable connection or connector OOSwitching output (WM electronics) Power supply: 24 V DC +15% / -10% 24/115/230 V AC ±20% 3.5 W max. Output: changeover contact, max. 250 V/5A Contact resistance: <100 mω Electrical connection: 1.5 m cable connection or connector O O K electronics with digital display, MIN/MAX contact, analogue output Power supply: 24 V DC +15% / -10% 5 W max. Analogue output: 0(4)-20 ma or 0-10 V Max. load: 500 Ω Switching output: MIN- and MAX-changeover contact, max. 24 V/2A Hysteresis: 2.5% of measured value Electrical connection: 1.5 m cable connection Electronics OODFT-...Exxx (counter electronics) Display: LCD module, 2 x 8-digit, illuminated, total, part and flow quantity; units of measurement selectable Quantity meter: 8-digit Analogue output: (0)4... 20 ma selectable Load: 0... 500 Ω or 0-10 V DC, Load: > 100 kω Relay outputs: 2 relays, max. 250 V/5 A/1000 VA Control elements: 4 keys Functions: Power supply: Electr. connection: OODFT-...Gxxx (Dosage electronics) reset, MIN/MAX-memory, flow monitor, part and total quantity monitoring, language 24 V DC ± 20%, 3-line approx. 100 ma 10-pin cable connection or 2 x plug M12 (5-/ 8-pin) Display: LCD module, 2 x 8-digit, illuminated, total, part and flow quantity; units of measurement selectable Quantity meter: 8-digit Dosage meter: 5-digit Analogue output: (0)4...20 ma selectable Load: 0...500 Ω or 0-10 V DC, Load: > 100 kω Relay outputs: 2 relays, max. 250 V/5 A/1000 VA Control elements: 4 keys Functions: Power supply: Electr. connection: dosage (relay S2), start, stop, reset, fine dosage, correction quantity, flow monitor, total quantity monitoring, language 24 V DC ± 20%, 3-line approx. 100 ma 10-pole cable connection or 2 x plug M12 (5-/ 8-pin) Frequency/Pressure-loss Table Measuring range Brass housing PTFE housing [l/min] Oriface [mm] Frequency Pressure loss Oriface [mm] Frequency Pressure loss 0.2-2.0 2.0 approx. 70 Hz 0.8 bar 2.0 approx. 80 Hz 0.7 bar 0.5-7 4.3 approx. 85 Hz 0.6 bar 4.3 approx. 95 Hz 0.5 bar 1-16 5.9 approx. 130 Hz 0.8 bar 5.9 approx. 140 Hz 0.7 bar 2-36 9.0 approx. 130 Hz 0.8 bar 9.0 approx. 120 Hz 0.9 bar 3-60 13.5 approx. 85 Hz 0.8 bar 13.5 approx. 80 Hz 0.9 bar www.kobold.com 3

Order Details (Example: DFT-1103 G2 F400) Measuring range Model Connection [l/min] 0.2-2.0 0.5-7 1-16 Brass housing ceramic axle DFT-1103.. DFT-1107.. DFT-1116.. PTFE housing ceramic axle DFT-1303.. DFT-1307.. DFT-1316.. Brass housing sapphire axle DFT-1603.. DFT-1607.. DFT-1616.. PTFE housing sapphire axle DFT-1803.. DFT-1807.. DFT-1816.. 2-36 DFT-1136.. DFT-1336.. DFT-1636.. DFT-1836.. 3-60 DFT-1160.. DFT-1360.. DFT-1660.. DFT-1860.. female thread..g2.. = G ¼..G4.. = G ½..N2.. = ¼" NPT..N4.. = ½" NPT..G4.. = G ½..G5.. = G ¾..N4.. = ½" NPT..N5.. = ¾" NPT..G5.. = G ¾..N5.. = ¾" NPT Evaluating electronics OEM frequency output (OEM)...0000 = NPN, connector DIN 43 650 Frequency output...f400 = PNP, connector DIN 43 650...F4 = PNP, connector DIN 43 650, frequency divider 0.25...2 Analogue output...l403 = connector DIN 43 650, 0-20 ma, 3-wire...L443 = connector DIN 43 650, 4-20 ma, 3-wire...L442 = connector DIN 43 650, 4-20 ma, 2-wire MA electronics with analogue output Electronic type Auxiliary power Analogue output..0.. = 230 V AC..MK.. = 1.5 m cable connection..0 = 0-20 ma..1.. = 110 V AC..MS.. = connector..4 = 4-20 ma..2.. = 24 V AC..MG.. = connector and mating connector..1 = 0-10 V..3.. = 24 V DC WM electronics with 1 contact Electronic type Auxiliary power Analogue output..0.. = 230 V AC..WK.. = 1.5 m cable connection..1.. = 110 V AC..WS.. = connector..2.. = 24 V AC..WG.. = connector and mating connector..3.. = 24 V DC..X = without analogue output K electronics (display, MIN/MAX-contact, analogue output) Electronic type Auxiliary power Analogue output..kk.. = 1.5 m cable connection..3.. = 24 V DC..4 = 4-20 ma..0 = 0-20 ma..1 = 0-10 V Counter electronics / dosage electronics Electronic type Electrical connection / power supply Analogue output E = counter electronics (2 x changer) G = dosage electronics (2 x changer) 3 = plug 2x M12 / 24 V DC 1 = 1.5 m cable / 24 V DC 9 = x m cable / 24 V DC 4R =0(4)-20 ma 1R =0-10 V 4 www.kobold.com

Dimensions Brass Housing [mm] DFT-... 0000 35 48 approx. ca. 60 60 DFT-... F4... / DFT-... L4... approx. ca. 108 108 35 48 DFT with MA- / WM- / K- / E- / G- electronics 35 108,9 48 www.kobold.com 5

Dimensions PTFE Housing [mm] DFT-... 0000 47 58 approx. ca. 60 60 DFT-... F4... / DFT-... L4... approx. ca. 122 122 47 58 DFT with MA- / WM- / K- / E- / G- electronics approx. ca. 121 121 47 approx. ca. 164 164 6 www.kobold.com