Minicontactorrelay,2NO/2NC,DCoperated

Similar documents
Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM12 10(24VDC) Article No.:

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

AS09..S 3-pole Contactors - Spring Terminals

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Series CT7N Bimetallic Overload Relays

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

A V 50Hz / V 60Hz

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Bulletin 190 IEC Modular Starter System

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

02/11/2015

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Datasheet - SRB301LC 24VAC/DC

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Magnecraft Power Relays

Datasheet - SRB-E-201ST

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

Pluggable interface relays CR-M Miniature relays

AC1036. Definite Purpose Contactors

Ordering details. Approval. Classification

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Data Sheet Definite Purpose Contactors Ex9CK Series

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Magnetic and Hydraulic-Magnetic Circuit Breaker

GV2ME. Main. Device short name. Device application

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

ALLEN BRADLEY TIMING RELAY

Kuhnke Technical Data. Contact Details

Pluggable interface relays CR-M Miniature relays

Bulletin 100-G IEC Contactors

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Interface Relays and Optocouplers Product group picture

High performance circuit breakers

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Series CDP2 Definite Purpose Contactors

.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

GV2ME. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application

Manual Motor Starter Specifcations

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

Process transmitter RMA422

8 Installation Equipment

Modular pulse operated latching relay 16 A

Process Transmitter RMA 422

Series CDP2 Definite Purpose Contactors

Bulletin 100-G IEC Contactors

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Circuit-Breakers for Motor Protection Series 8523/8

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

Type Contact form Model

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

16 A and 25 A power contactors with or without handle

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

Nessie Coils for VDH and VDHT valves

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Generator protection relay

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

Transcription:

Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique Screw terminals Rated operational current -15 220 V 230 V 240 V I e A 6 380 V 400 V 415 V I e A 3 Contacts N/O = Normally open 2 N/O N/C = Normally closed 2 NC Contact sequence Code number and version of combination Distinctive number 22E For use with - Actuating voltage 24 V DC Voltage /DC DC operation Instructions Contact numbers to EN 50011 Coil terminal markings to EN 50005 Integrated diode-resistor combination Coil rating 2.6 W InformationrelevantforexporttoNorthAmerica Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Approvals Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical operated Operations x 10 6 10 DC operated Operations x 10 6 20 Maximum operating frequency Ops./ h Maximum operating frequency Operations/ h 9000 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 01/10/2014 HPL-ED2013 V2.11 EN 1 / 7

Ambient temperature C Open C - 25-50 Enclosed C - 25-40 Mounting position Mounting position As required, except vertical with terminals A1/A2 at the bottom Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 10 ms Basic unit with auxiliary contact module g N/O contact g 10 N/C contact g 8 Protection type IP20 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Weight operated kg 0.17 DC operated kg 0.2 Terminal capacities mm 2 Screw terminals Solid 2 mm 1 x (0.75-2.5) 2 x (0.75-2.5) Flexible with ferrule 2 mm 1 x (0.75-1.5) 2 x (0.75-1.5) Solid or stranded AWG 18-14 Terminal screw M3.5 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1 x 6 Max. tightening torque Nm 1.2 Spring-loaded terminals Solid 2 mm 1 x (1-2.5) 2 x (1-2.5) Flexible with or without ferrule DIN 46228 2 mm 1 x (1-2.5) 2 x (1-2.5) Solid or stranded AWG 1 x (16-14) 2 x (16-14) Standard screwdriver mm 0.6 x 3.5 Contacts Positive operating contacts to ZH 1/457, including auxiliary contact module Yes Rated impulse withstand voltage U imp V 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V Rated operational voltage U e V 690 600 Safe isolation to EN 61140 between coil and auxiliary contacts V between the auxiliary contacts V 300 300 Rated operational current A Conventional free air thermal current, 3 pole, 50-60 Hz Open Conv. thermal current I th A 10-15 220 V 230 V 240 V I e A 6 380 V 400 V 415 V I e A 3 500 V I e A 1.5 DC current DC-13 L/R - 15 ms 01/10/2014 HPL-ED2013 V2.11 EN 2 / 7

Contacts in series: A 1 24 V A 2.5 2 60 V A 2.5 3 110 V A 1.5 3 220 V A 0.5 Short-circuit rating without welding Maximum overcurrent protective device 220/240 V PKZM0 4 380/415 V PKZM0 4 Short-circuit protection maximum fuse 500 V A gg/ gl 500 V A fast 6 10 Current heat loss at I th operated W 0.2 DC operated W 0.3 Magnetsystems Voltage tolerance x U c operated x U c Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Pick-up x U c 0.8-1.1 Dual-frequency coil 50/60 Hz Pick-up x U c 0.85-1.1 DC operated x U c Pick-up voltage Pick-up x U c 0.85-1.3 at 24 V: without auxiliary contact component (40 C) Pick-up x U c 0.7-1.3 Power consumption 50 Hz Pick-up VA 25 50 Hz Sealing VA 4.6 50 Hz Sealing W 1.3 60 Hz Pick-up VA 25 60 Hz Sealing VA 4.6 60 Hz Sealing W 1.3 50/60 Hz Pick-up VA 30 29 50/60 Hz Sealing VA 5.4 3.9 50/60 Hz Sealing W 1.6 1.1 DC operated Pull-in = sealing W 2.6 duty factor % DF 100 Switching times at 100 % U c (approximate values) operated closing delay ms 14-21 operated N/O contact opening delay ms 8-18 operated With auxiliary contact module Max. closing delay ms 45 DC operated closing delay ms 26-35 DC operated N/O contact opening delay ms 15-25 DC operated With auxiliary contact module Max. closing delay ms 70 Notes NotesMaking and breaking conditions to DC-13, time constant as stated See transparent overlay "Fuses" for time/current characteristics (please enquire) Use only equal cross-sections TechnicaldataETIM5.0 Low-voltage industrial components (EG000017) / Contactor relay (EC000196) Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Contactor relay (ecl@ss8-27-37-10-01 [AAB716010]) Rated control supply voltage Us at 50HZ V 0-0 01/10/2014 HPL-ED2013 V2.11 EN 3 / 7

Rated control supply voltage Us at 60HZ V 0-0 Rated control supply voltage Us at DC V 24-24 Voltage type for actuating DC Rated operation current Ie, 400 V A 3 Connection type auxiliary circuit Screw connection normally closed contact normally open contact normally closed contact, delayed switching normally open contact, leading change-over contact 2 2 0 0 0 Characteristics 01/10/2014 HPL-ED2013 V2.11 EN 4 / 7

1: Suppressor Characteristic curves 01/10/2014 HPL-ED2013 V2.11 EN 5 / 7

Component lifespan (operations) Ie = Rated operational current Dimensions DILER- DILER- -G 01/10/2014 HPL-ED2013 V2.11 EN 6 / 7

DILER- + DILE DILER- -G + DILE Additionalproductinformation(links) IL03407009Z(AWA2100-0882)Minicontactorrelay IL03407009Z (AWA2100-0882) Mini contactor relay ftp://ftp.moeller.net/documentation/awa_instructions/il03407009z2010_10.pdf http://de.ecat.moeller.net/flip-cat/?edition=hplte&startpage=5.84 01/10/2014 Eaton Industries GmbH http://www.eaton.eu 12/2013 by Eaton Industries GmbH HPL-ED2013 V2.11 EN 7 / 7