DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Similar documents
DMP 331i / DMP 333i LMP 331 i

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Pressure transmitter For applications in hazardous areas Model IS-3

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

TFRN Industrial RTD temperature sensor. CombiTemp TM

Inductive sensor NI3-EG08K-Y1-H1341

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor BI1.5-EG08K-Y1

TFRN Industrial RTD temperature sensor. CombiTemp TM

PROPORTIONAL VALVES Sentronic plus

Inductive sensor With analog output BI15-M30-LI-EXI

PMG. Vibration Energy Harvesters

Process transmitter RMA422

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Process Transmitter RMA 422

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Pressure transmitter COMPACT IO-Link,

RSCC. Load cells. Special features. Data sheet

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Selection matrix for electronic pressure switches

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Photoelectrics Through-beam Type PA18C.T..., DC

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Pendant Light Fitting IEC Series 6470/2

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Mechanical flow switch for On/Off control

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Micro-Machined Silicon Transducers

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

The full range of performance

Linear flow control with actuator IFC

Absolute Encoders Multiturn

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Model JDF Field Indicator

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Single Point Flow Monitor SW118 SW119

CombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Capacitance Level Measurement Electronic insert FEC 12

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Linear flow controls VFC Linear flow controls with actuator IFC

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Wall-/Pipe-Mount Level Indicator

SPACESCAN SERIES SS 02

Signet 2250 Hydrostatic Level Sensor

Level Measurement silometer FMC 420, FMC 423

Operating instructions

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

User manual Version Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../...

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Model KBF 115 Constant climate chambers with large temperature / humidity range

3 Cleaning. 4 Technical data

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

IMPAC Infrared Thermometers

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Model ED 400 Drying and heating chambers Classic.Line with natural convection

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Flow Measurement SITRANS F M

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Speed sensor MiniCoder GEL 2471

IONIVAC Transmitter ITR 90

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

IEPE Premium Accelerometer, Top Connector

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Level Measurement Point level measurement - RF Capacitance switches

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Transcription:

DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request Product characteristics The precision pressure transmitter DMP i and DMP i demonstrate the further development of our industrial pressure transmitters. The signal processing of sensor signal is done by digital electronics with 6bit analogue digital converter. Consequently it is possible to conduct an active compensation and the transmitters with excellent measurements and exceptionally attractive price to offer on the market. thermal error in compensated range 0... 80 C: 0. % FSO TC 0.0 % FSO / 0K TurnDown :0 communication interface for adjusting of offset, span and damping Preferred areas of use are Optional versions ISversions Ex ia = intrinsically safe for gases and dusts adjustment of nominal pressure gauges (factoryprovided) Laboratory Techniques Energy production (gas consumption and thermal energy measurement) BD SENSORS GmbH BDSensorsStraße Tel: +9 (0) 9 / 98 0 www.bdsensors.com D 999 Thierstein Fax: +9 (0) 9 / 98 info@bdsensors.de

DMP i / DMP i Pressure ranges DMP i [bar] gauge / absolute [bar] 0. 0 0 0 60 Overpressure [bar] 0 0 0 80 0 0 Burst pressure [bar]. 0 0 0 0 Vacuum ranges [bar] 0.... 0............. 0 Overpressure [bar] 0 0 0 Burst pressure [bar]. 0 Pressure ranges DMP i [bar] [ gauge / absolute bar] 00 00 00 600 Overpressure [bar] 0 600 000 000 Burst pressure [bar] 0 000 0 0 On request we adjust the device within the turndownpossibility by software on the required pressure range. Output signal / Supply Standard wire:... 0 ma / V S =... 6 V DC Option ISprotection wire:... 0 ma / V S =... 8 V DC Options analogue signal wire:... 0 ma with communication interface wire: 0... 0 V / V S =... 6 V DC 0... 0 V with communication interface only possible with el. connection Binder series (pin) Performance Accuracy performance after turndown TD : TD > : Permissible load IEC 600 : ± 0. % FSO no change of accuracy for calculation use the following formula (for nominal pressure ranges 0.0 bar see note ): ± [0. + 0.0 x turndown] % FSO with turndown = nominal pressure range / adjusted range e.g. with a turndown of :0 following accuracy is calculated: ± (0. + 0.0 x 0) % FSO i.e. accuracy is ± 0. % FSO current wire: R max = [(V S V S min ) / 0.0 A] voltage wire: R min = 0 k Influence effects supply: 0.0 % FSO / 0 V load: 0.0 % FSO / k Long term stability ± (0. x turndown) % FSO / year at reference conditions Response time approx. msec Adjustability configuration of following parameters possible (interface / software necessary ): electronic damping: 0... 00 sec offset: 0... 90 % FSO turn down of span: max. :0 accuracy according to IEC 600 limit point adjustment (nonlinearity, hysteresis, repeatability) except nominal pressure ranges 0.0 bar; for these calculation of accuracy is as follows: ± (0. + 0.0 x turndown) % FSO e.g. turndown of :: ± (0. + 0.0 x ) % FSO i.e. accuracy is ± 0.6 % FSO software, interface, and cable have to be ordered separately (software appropriate for Windows 9, 98, 000, NT Version.0 or higher, and XP) Thermal effects (Offset and Span) / Permissible temperatures Tolerance band [% FSO] ± (0. x turndown) in compensated range 0... 80 C TC, average [% FSO / 0 K] ± (0.0 x turndown) in compensated range 0... 80 C Permissible temperatures medium:... C electronics / environment:... 8 C storage: 0... 00 C Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Materials Pressure port stainless steel.0 (6 L) Housing stainless steel.0 (6 L) Seals FKM; NBR welded version 6 others on request Diaphragm stainless steel. (6L) Media wetted parts pressure port, seal, diaphragm 6 welded version only with pressure ports according to EN 8; welded version not available with pressure ranges > 60 bar pressure and level

DMP i / DMP i Mechanical stability Vibration 0 g RMS (0... 000 Hz) Shock 00 g / msec. Explosion protection (only for... 0 ma / wire) Approvals DX9DMP i IBExU 0 ATEX 068 X / IECEx IBE.00X DX9DMP i zone 0: II G Ex ia IIC T Ga zone 0: II D Ex ia IIIC T 8 C Da Safety technical max. values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 H, the supply connections have an inner capacity of max. nf to the housing Ambient temperature range in zone 0: 0... 60 C with p atm 0.8 bar up to. bar in zone or higher: 0... 6 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: H/m Miscellaneous Current consumption signal output current: max. ma signal output voltage: max. ma Weight approx. 00 g Installation position any Operational life > 00 x 0 6 pressure cycles CEconformity EMC Directive: 0/0/EU Pressure Equipment Directive: 0/68/EU (module A) 8 ATEX Directive 0//EU Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviations in the zero point for pressure ranges PN bar. 8 This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams wiresystem (current) p wiresystem (voltage) p VS VS I U signal + V Pin configuration Electrical connections signal + (only for wire) Communication interface 9 shield RxD TxD GND ISO 00 ground pin Binder (pin) Binder (pin) 6 Mx / metal (pin) pressure port 9 may not be transmitted directly with the PC (the suitable adapter is available as accessory) Dimensions (mm / in) Bayonet MILC 68 (06) field housing wire wire A A IN + B D IN B OUT + cable colours (IEC 60) wh (white) bn (brown) gn (green) gnye (greenyellow) DMPi 0 DMP i 0, DMP i with RS 0 with electrical connection Bayonet MILC68 (06) increases the length of devices by mm for nominal pressure PN > 00 bar increases the length without ISversion by 9 mm and with ISversion by 9 mm www.bdsensors.com

DMP i / DMP i Electrical connections (dimensions mm / in) standard optional ISO 00 Mx pin Binder series Binder series Bayonet (IP6) (IP 6) pin pin MILC68 (06) (IP 6) (IP 6) (IP 6) cable outlet, cable outlet, compact field housing with PVC cable cable with ventilation tube (IP 6) (IP 6) (IP 68) universalfield housing stainless steel 6L with cable gland M0x. (ordering code 880) and other versions on request standard: m PVC cable (without ventilation tube, permissible temperature:... 0 C); others on request different cable types and lengths available, permissible temperature depends on kind of cable Mechanical connection (dimensions in mm / inch) G/" DIN 8 G/" DIN 8 G/" EN 8 G/" EN 8 G/" open port, /" NPT /" NPT PN 0 bar metric threads and others on request Windows is a registered trade mark of Microsoft Corporation 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. DMPi_E_008 pressure Tel: and +9 level (0) 9 / 98 0 www.bdsensors.com Fax: +9 (0) 9 / 98 info@bdsensors.de

Ordering code DMP i/ DMP i DMP i/ DMP i Pressure For DMP i gauge absolute For DMP i gauge absolute Input [mh O] [bar] 0 0 0.0 0 0 0 0.0 0 0 0.0 0 0 0.0 0 0 00 0 0 0 00 0 0 0 00 0 0 0 600 60 6 0 0 For DMP i 00 0 0 00 0 0 00 0 0 600 6 0 0 For DMP i 0.0 0.0 S 0 0 S 0 V 0 V 0 0 V 0 9 9 9 Output 0 ma / wire Intrinsic safety 0 ma / wire 0 0 V / wire Accuracy (at nominal pressure) 0. % Electrical connection Male and female plug ISO 00 0 0 Male plug Binder series (pin) 0 0 Compact field housing 8 0 stainless steel.0 (6L) Male and female plug A 0 0 Binder series (pin) Male plug Mx (pin) / metal M 0 for analog output Male plug Mx (pin) / metal M for digital output Bayonet MILC68 (06); wire B G 0 Bayonet MILC68 (06); wire B G Cable outlet with PVC cable T A 0 Cable outlet Mechanical connection G/" DIN 8 G/" EN 8 G/" DIN 8 G/" EN 8 G/" DIN 8 with flush sensor G/" DIN 8 open pressure port /" NPT /" NPT Seals For DMP i For DMP i Special version measurement starts with ambient pressure pressure ranges 60 bar as DMP i; pressure ranges > 60 bar as DMP i standard: m PVC cable without ventilation tube (permissible temperature: 0 C), optionally cable with ventilation tube cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable only possible for DMP i and P N 0 bar FKM without (welded version) FKM NBR standard RS interface 6 welded version only with pressure ports according to EN 8 RS interface only possible with el. connection Binder serie (pin) Software, Interface and cable for DMP i and DMP i with option RS have to be order separately (Ordering code: CISG; Software appropriate for Windows 9, 98, 000, NT Version.0 or newer and XP) Windows is a registrated trademark of Microsoft Corporation E T R 0 9 9, 6 0 0 0 0 0 0 0 0 F 0 0 H 0 0 N 0 0 N 0 9 9 9 9.0.08 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.