Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

Similar documents
Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

R&S ZN-Z85 Switch Matrix Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S HF907DC SHF Downconverter Specifications

R&S ZN-Z154 Calibration Unit Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S ZN-ZTW Torque Wrench Specifications

R&S DST200 RF Diagnostic Chamber Specifications

R&S FSW-K144 5G NR Measurement Application Specifications

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S GU221 Filter Control Unit Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

R&S AVG050 DVB Satellite Receiver Specifications

R&S DDF200M Digital Direction Finder Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

R&S RT-Zxx Standard Probes Specifications

R&S ZVA110 Vector Network Analyzer Specifications

R&S FSV-K40 Phase Noise Measurement Application Specifications

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

R&S EDS300 DME/Pulse Analyzer Specifications

R&S FPC1000 Spectrum Analyzer Specifications

R&S ZND Vector Network Analyzer Specifications

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

R&S FPS-K18 Amplifier Measurements Specifications

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

R&S SGU100A SGMA Upconverter Specifications

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

R&S NRPM Over-the-Air (OTA) Power Measurement Solution Specifications

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S ZNBT Vector Network Analyzer Specifications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

R&S RSC Step Attenuator Where precise signal levels count

R&S EDST300 TACAN/DME Station Tester Specifications

EUTRA/LTE Downlink Specifications

R&S SGS100A SGMA RF Source Specifications

EX-IQ-Box Digital Signal Interface Module Specifications

EUTRA/LTE Measurement Application Specifications

R&S ZNrun Automated Test Software PC-based server platform for automated VNA tests

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

R&S BBL200 Broadband Amplifier Specifications

R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

R&S VSE Vector Signal Explorer Base Software Specifications

R&S GX465 Digital Wideband Storage Device Recording and replaying of I/Q data with up to 80 MHz bandwidth

R&S TS-PSM5 High-Power Switching Module Automotive DUT supply and load switching up to 50 A

R&S GX460 Digital Wideband Storage Device Recording and replaying device for I/Q data with up to 40 MHz bandwidth

R&S Spectrum Rider FPH Handheld spectrum analyzer

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

RF amplifier testing from wafer to design-in

WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications

R&S TS-PSM3 High-Power Switching Module Automotive DUT supply and load switching up to 30 A

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

Be ahead in 5G. Turn visions into reality.

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

Your partner in testing the Internet of Things

Oscilloscopes for debugging automotive Ethernet networks

Scope of the art Scope Rider Handheld digital oscilloscope

R&S TS-PFG Function Generator Module Dual-channel arbitrary waveform generator with isolated outputs

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S RT-ZM Modular Probe System

Rohde & Schwarz Service that adds value

R&S CONTEST ITS Test cases and applications

Test Port Adapter Rohde & Schwarz Interchangeable Port Connector Application Note

R&S TS-PIO4 Digital Functional Test Module 32-channel programmable digital I/O module

R&S CA210 Signal Analysis Software Offline analysis of recorded signals and wideband signal scenarios

R&S VSE Vector Signal Explorer Base Software Specifications

R&S M3TR R&S VT3050C 50 W VHF/UHF Compact Power Amplifier Specifications

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

Test Device Containment Module (TCM) Optimal conditions for reliable results

R&S SGMA Product Family Compact fast reliable

R&S FPC-Z10 Teaching Kit Getting Started

R&S NESTOR-FOR Crime Scene Investigation

DOCSIS 3.1 Full channel loading Maximizing data throughput

Product Brochure Version R&S AdVISE Visual Inspection Software A new way to eliminate human inattention

R&S AVG050 ISDB-T BTS Gateway Specifications

R&S FPC Spectrum Analyzer Unexpected performance in entry class

R&S NESTOR-FOR Alibi Verification

Multi-port calibration by using a two port calibration unit. Application Note. Products: R&S ZVT R&S ZNB

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Configuring the R&S BTC for ATSC 3.0 Application Note

Transcription:

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications R&S TC-TA18 cross-polarized Vivaldi test antenna, R&S TC-TA85CP cross-polarized Vivaldi test antenna, R&S TC-TA85LP linear-polarized Vivaldi test antenna, R&S TC-CA6 linear-polarized communications antenna Data Sheet Version 04.00

CONTENTS Definitions... 3 Test antennas... 4 R&S TC-TA18 cross-polarized Vivaldi test antenna... 4 R&S TC-TA85CP cross-polarized Vivaldi test antenna... 10 R&S TC-TA85LP linear-polarized Vivaldi test antenna... 10 Communications antenna... 13 R&S TC-CA6 linear-polarized communications antenna... 13 General data... 15 Ordering information... 15 2 Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Device settings and GUI parameters are indicated as follows: parameter: value. Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System 3

Test antennas R&S TC-TA18 cross-polarized Vivaldi test antenna VSWR specified at the SMA connectors of the R&S TC-TA18 400 MHz to 700 MHz < 3 700 MHz to 18 GHz < 2 Impedance 50 Ω (nom.) Power rating 400 MHz to 18 GHz < 4 W CW (meas.) Polarization dual linear (nom.) Port-to-port isolation 400 MHz to 18 GHz > 20 db RF connector ANT1, ANT2 2 SMA (f) Outer dimensions (W H D) without transport case 248 mm 248 mm 193 mm (9.76 in 9.76 in 7.60 in) with transport case 400 mm 365 mm 380 mm (15.75 in 14.37 in 14.96 in) Weight without transport case approx. 1.6 kg (3.5 lb) with transport case approx. 6.1 kg (13.4 lb) Mounting interface of the R&S TC-TA18 cross-polarized Vivaldi test antenna. 4 Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System

VSWR of the R&S TC-TA18 cross-polarized Vivaldi test antenna (meas.). Port-to-port isolation of the R&S TC-TA18 cross-polarized Vivaldi test antenna (meas.). Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System 5

Directivity and gain of the R&S TC-TA18 cross-polarized Vivaldi test antenna; port ANT1 (meas.). Directivity and gain of the R&S TC-TA18 cross-polarized Vivaldi test antenna; port ANT2 (meas.). 6 Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System

Cross-polarization discrimination of the R&S TC-TA18 cross-polarized Vivaldi test antenna (meas.). Half-power beamwidth of the R&S TC-TA18 cross-polarized Vivaldi test antenna; port ANT1 (meas.). Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System 7

Half-power beamwidth of the R&S TC-TA18 cross-polarized Vivaldi test antenna; port ANT2 (meas.). 8 Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System

Partial directivity of the R&S TC-TA18 cross-polarized Vivaldi test antenna at 3 GHz; port ANT1 (meas.). Partial directivity of the R&S TC-TA18 cross-polarized Vivaldi test antenna at 3 GHz; port ANT2 (meas.). Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System 9

R&S TC-TA85CP cross-polarized Vivaldi test antenna VSWR specified at the R&S TC-MMPX-A2 RF adapter connected to the MMPX connector of the R&S TC-TA85CP 4 GHz to 7 GHz < 2.5 7 GHz to 67 GHz < 2.2 67 to 85 GHz < 2.2 (meas.) 1 Impedance 50 Ω (nom.) Polarization dual linear (nom.) Port-to-port isolation > 25 db RF connector ANT1, ANT2 2 MMPX (f) Durability (matings) 100 Outer dimensions (H D) 77.3 mm 28 mm (3.04 in 1.10 in) Weight approx. 14 g (0.031 lb) R&S TC-TA85LP linear-polarized Vivaldi test antenna VSWR specified at the R&S TC-MMPX-A2 RF adapter connected to the MMPX connector of the R&S TC-TA85LP 4 GHz to 67 GHz < 2.2 67 to 85 GHz < 2.2 (meas.) 1 Impedance 50 Ω (nom.) Polarization linear (nom.) RF connector MMPX (f) Durability (matings) 100 Outer dimensions (H D) 79.6 mm 28 mm (3.13 in 1.10 in) Weight approx. 12 g (0.027 lb) Dimensions of the R&S TC-TA85CP cross-polarized (left) and the R&S TC-TA85LP linear-polarized (right) Vivaldi test antennas. 1 Measurements above 67 GHz were performed using R&S TC-MMPX-A1 RF adapter. 10 Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System

Mounting interface of the R&S TC-TA85CP and the R&S TC-TA85LP Vivaldi test antennas. VSWR of the R&S TC-TA85CP cross-polarized Vivaldi test antenna (meas.). Antenna gain of the R&S TC-TA85CP cross-polarized Vivaldi test antenna (meas.). Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System 11

Port-to-port isolation of the R&S TC-TA85CP cross-polarized Vivaldi test antenna (meas.). VSWR of the R&S TC-TA85LP linear-polarized Vivaldi test antenna (meas.). Antenna gain of the R&S TC-TA85LP linear-polarized Vivaldi test antenna (meas.). 12 Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System

Communications antenna R&S TC-CA6 linear-polarized communications antenna VSWR specified at the SMP connector of the R&S TC-CA6 antenna 600 MHz to 700 MHz < 6 (meas.) 700 MHz to 2.4 GHz < 4 (meas.) 2.4 GHz to 6 GHz < 2 Impedance 50 Ω (nom.) Polarization linear (nom.) RF connector SMP (m) Outer dimensions (W H D) without RF cable 80 mm 70 mm 8 mm (3.15 in 2.76 in 0.31 in) Weight without RF cable approx. 24 g (0.05 lb) Antenna mounting self-adhesive hook and loop tape 20 mm 60 mm (0.79 in 2.36 in) RF cable length 1 m (39.37 in) connectors 1 SMP (f), 1 SMA (m) VSWR of the R&S TC-CA6 linear-polarized communications antenna (meas.). Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System 13

Gain of the R&S TC-CA6 linear-polarized communications antenna (meas.). 14 Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System

General data Environmental conditions Temperature operating temperature range +5 C to +35 C storage temperature range 25 C to +70 C Damp heat +30 C/70 % rel. humidity/constant, in line with EN 60068-2-78 Mechanical resistance Vibration sinusoidal 5 Hz to 55 Hz, 0.3 mm double amplitude, 55 Hz to 150 Hz, 0.5 g const., in line with EN 60068-2-6 random 8 Hz to 500 Hz, acceleration 1.2 g RMS, in line with EN 60068-2-64 shock 45 Hz to 2000 Hz: max 40 g, in line with MIL-STD-810, method 516, procedure I Ordering information Designation Type Order No. Cross-Polarized Vivaldi Test Antenna for the R&S TS8991 R&S TC-TA18 1530.8075.02 Linear-Polarized Communications Antenna for the R&S TS8991 R&S TC-CA6 1530.8069.02 Cross-Polarized Vivaldi Test Antenna, 4 GHz to 85 GHz R&S TC-TA85CP 1531.8627.02 Linear-Polarized Vivaldi Test Antenna, 4 GHz to 85 GHz R&S TC-TA85LP 1531.8610.02 Recommended extras for R&S TC-TA85CP and R&S TC-TA85LP RF Adapter, MMPX (m) to 1.00 mm (f) R&S TC-MMPX-A1 3652.0435.02 RF Adapter, MMPX (m) to 1.85 mm (f) R&S TC-MMPX-A2 3652.0441.02 RF Cable, MMPX (m) to 1.85 mm (f), length 180 mm R&S TC-MMPX-C1 3652.0387.02 RF Cable, MMPX (m) to 1.85 mm (m), length 230 mm R&S TC-MMPX-C2 3652.0406.02 RF Cable, MMPX (m) to 2.92 mm (f), length 180 mm R&S TC-MMPX-C3 3652.0412.02 RF Cable, MMPX (m) to 2.92 mm (m), length 230 mm R&S TC-MMPX-C4 3652.0429.02 For R&S TS8991 product brochure, see PD 5213.8796.12 and www.rohde-schwarz.com Rohde & Schwarz Test and Communications Antennas for the R&S TS8991 OTA Performance Test System 15

Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability Rohde & Schwarz The Rohde & Schwarz electronics group offers innovative solutions in the following business fields: test and measurement, broadcast and media, secure communications, cybersecurity, monitoring and network testing. Founded more than 80 years ago, the independent company which is headquartered in Munich, Germany, has an extensive sales and service network with locations in more than 70 countries. Sustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownership Certified Quality Management ISO 9001 Certified Environmental Management ISO 14001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Rohde & Schwarz training www.training.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 82 28 +86 400 650 58 96 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD 3607.5102.22 Version 04.00 February 2018 (fi) Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Data without tolerance limits is not binding Subject to change 2016 2018 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany 3607.5102.22 04.00 PDP 1 en 3607510222