Oscilloscopes. the new hmo 3000 SerieS 300 Mhz 400 Mhz 500 Mhz

Similar documents
Great Value in Test & Measurement. Mixed Signal Oscilloscopes HMO 3000 SerieS 300 MHz 400 MHz 500 MHz

100MHz 2[4] Channel Digital Oscilloscope HMO1022 [HMO1024]

350MHz 2[4] Channel Digital Oscilloscope HMO3522 [HMO3524]

Mixed Signal Oscilloscopes 300 MHz 400 MHz 500 MHz HMO3000 Series

HMO3000 Series Mixed Signal Oscilloscopes 300/400/500 MHz Bandwidth

R&S HMO3000 Series Mixed Signal Oscilloscopes 300/400/500 MHz Bandwidth

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

Digital Storage Oscilloscopes 2550 Series

R&S HMO Compact Series Mixed Signal Oscilloscopes 70/100/150/200 MHz Bandwidth

R&S HMO3000 Series Mixed Signal Oscilloscopes 300/400/500 MHz Bandwidth

R&S HMO1002, R&S HMO1202 Two-channel digital oscilloscopes 50 MHz to 300 MHz bandwidth. Test & Measurement Product Brochure 02.01

R&S HMO1002 Digital Oscilloscope 50/70/100 MHz Bandwidth

R&S HMO1002, R&S HMO1202 Two-channel digital oscilloscopes 50 MHz to 300 MHz bandwidth

SDS1000C Specifications

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

Portable Performance for Debug and Validation

Product Brochure Test & Measurement. R&S HMO1002 Digital Oscilloscope 50/70/100 MHz Bandwidth

2016 RIGOL TECHNOLOGIES, INC.

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

Max. sampling rate (realtime) channel. interleaved. 1 Gsample/s. interleaved. 2.5 Gsample/s per channel 5 Gsample/s. 5 Gsample/s per channel

Expect to Make Waves.

Agilent Technologies 54522A

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

ScopeMeter 190 Series Specifications

ADS1000C, CAL / CML Series

DataSheet. SDS1000DL Series Digital Oscilloscope

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

50 MHz Digital Storage Oscilloscope

DataSheet SDS1000CFL Series Digital Oscilloscope

WaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz

DataSheet SDS1000CML Series Digital Oscilloscope

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Advanced Test Equipment Rentals ATEC (2832)

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

SDS1000CNL+ Series Digital Oscilloscope. DataSheet

WAVERUNNER 104XI AND 204XI

Analog Arts SA985 SA975 SA935 SA915 Product Specifications


Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

2 MHz Lock-In Amplifier

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

PicoScope 6407 Digitizer

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

4 MHz Lock-In Amplifier

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

PicoScope 6407 Digitizer

What is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

R&S RTM Digital Oscilloscope Scope of the art

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

SDS1000DL+/CML+ Series Digital Oscilloscope. DataSheet

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

PicoScope 6000 Series HIGH-PERFORMANCE USB OSCILLOSCOPES

WaveSurfer 3000 Oscilloscopes 200 MHz 500 MHz

Meeting your needs R&S RTO2000 Digital Oscilloscope

R&S RT-Zxx High-Bandwidth Probes Specifications

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

R&S RTB2000 Digital Oscilloscope Specifications

~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.

3000 Series. PicoScope. USB oscilloscopes

2 MHz Lock-In Amplifier

PicoScope 3000 Series

Agilent 6000 Series Oscilloscope Demo Guide

SMS3000X Series Spectrum Analyzer

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

2000 Series. PicoScope. The compact alternative to a benchtop oscilloscope

SX-METRO A software package to meet all your needs

Fluke /

R&S RTM Digital Oscilloscope Specifications

DSO7032A Oscilloscope: 350 MHz, 2 channels

R&S RTC1000 Oscilloscope Specifications

WaveSurfer MXs-B and MSO MXs-B Oscilloscopes

Digital Oscilloscope. Characterisation, Measurement & Analysis

20 years of ScopeMeter Test Tool Innovation Introducing the complete 190 Series II Technical Data. New 500 MHz

Data Pattern Generator DG2020A Data Sheet

Datasheet SHF A

R&S RTO Digital Oscilloscopes Scope of the art

Analog Dual-Standard Waveform Monitor

Agilent Series Oscilloscopes

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

R3267/3273 Spectrum Analyzers

User Manual. Digital Oscilloscope V1.9

Agilent 5345A Universal Counter, 500 MHz

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

Operator s Manual. WaveJet Touch Oscilloscopes

HX0074 DEMO Kit for METRIX Oscilloscopes

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

WAVESURFER XS SERIES. The Everyday Oscilloscope that s Easy to Use

Data Pattern Generator

Transcription:

Oscilloscopes the new hmo 3000 SerieS 300 Mhz 400 Mhz 500 Mhz

HMO 3004 SERIES, 500 MHz with 4 Channels Intelligent User Interface To optimize the screen display, the instrument shows and hides menus FFT Superb FFT functionality Quick View Automatic signal measurement at the push of a button Setup Intuitive, multi-lingual user menu Help Context-sensitive help Slope Direct selection of trigger edge at the push of a button Zoom Memory Zoom up to 200.000 : 1 Analog Channels Vertical Sensitivity of just 1mV/div. Display Superb 16.5cm (6.5 ) LED-backlit TFT Display Logic Channels Connections for up to 16 logic channels Bus Signal Source To create SPI, I 2 C, UART and counter test-signals Math Wide range of programmable math functions Fan Maximum noise reduction by temperature-controlled fan

the new HMO 3000 Series up to 500 MHz The new HMO3000 series by HAMEG Instruments offers our usual excellent performance at an attractive price. The standard MSO functionality allows you to analyze all analog channels plus up to an additional 16 digital channels. The 6 different models are available in a bandwidth of 300 MHz to 500 MHz with 2 or 4 channels. 4 GSa /s Real Time, Low Noise Flash A /D Converter 8 MPts Memory, oom up to 200,000:1 MSO: Mixed Signal Option HO3508 [HO3516] with 8 [16] Logic Channels Serial Bus Trigger and Hardware accelerated Decode including List View. Options: I 2 C + SPI + UART/RS-232 (HOO10/HOO11), CAN + LIN (HOO12) Vertical Sensitivity 1 mv/div., Offset Control ±0.2 ±20 V 6-Digit Hardware Counter real-time FFT (dbm, dbv, V eff ), up to 64 kpts Automatic Search for user-defined Events Pass/Fail Test based on Masks Auto-Measurement: max. 6 Parameters incl. Statistic, Formula Editor, Ratio Cursor Display Range: 12 div. x-axis, 20 div. y-axis (VirtualScreen) trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event, Hold-Off Automatically or manually adjustable Memory Depth 3 x USB for Mass Storage and Remote Control

UPGrADe At AnY time! Bandwidth Upgrade All models in the HMO3000 series with 300 MHz or 400 MHz can be extended via software upgrades to 500 MHz bandwidth whenever required: For 300 MHz models with options HOO352 (2 channels) and HOO354 (4 channels). For 400 MHz models with options HOO452 (2 channels) and HOO454 (4 channels). Options: HOO352 / HOO354 300 MHz >>> 500 MHz HOO452 / HOO454 400 MHz >>> 500 MHz 500 Mhz 300 Mhz 400 Mhz

APPLiCAtiOn Serial Bus Analysis I 2 C, SPI, CAN or LIN in terms of interaction with the outside world for embedded systems, it is safe to say that these are the most commonly used communication protocols. The new HMO3000 series by HAMEG Instruments offers you hardware-accelerated signal triggering and decoding for all of these protocols. You can upgrade your instrument via software licence keys with those functions required to develop your application: HOO10: Analysis of I 2 C, SPI and UART/RS232 signals on analog and logic channels HOO11: Analysis of I 2 C, SPI and UART/RS232 signals on all analog channels HOO12: Analysis of CAN and LIN signals on analog and logic channels The image shows an I 2 C communication between a machine controller and a payment unit, triggered to the start of a I 2 C data package. Furthermore, you can choose from a variety of additional trigger options: I 2 C: Start, Stop, ACK, nack, Address/Data SPI: Start, End, Serial Pattern (32Bit) UART/RS232: Startbit, Frame Start, Symbol, Pattern LIN: Frame Start, Wake Up, Identifier, Data, Error CAN: Frame Start, Frame End, Identifier, Data, Error

HMO3004 Series 4 Channel Digital Oscillscope HMO3002 Series 2 Channel Digital Oscillscope HMO3032 [HMO3034] 300MHz HMO3042 [HMO3044] 400MHz HMO3052 [HMO3054] 500MHz Display Display: 16.5 cm (6.5") VGA Color TFT Resolution: 640 x 480 Pixel Backlight: LED 500 cd / m 2 Display area for traces: 50 Pkt / div. without menu 400 x 600 Pixel (8 x 12div.) with menu 400 x 500 Pixel (8 x 10div.) Color depth: 256 colors Intensity steps per channel: 0 31 Channel display: False color, inverse brightness Bus display: up to 2 busses, parallel busses, serial busses (option), decoding of the bus values in ASCII, binary, decimal or hexadecimal format; Table view of the decoded data Virtual Screen 20 div. vertical for all Math-, Logic-, Busand Reference Signals LED brightness: 2 steps Vertical System Channels: DSO mode CH 1, CH 2 [CH 1 CH 4] MSO mode CH 1, CH 2, LCH 0 15 (logic channels) with 2 x Option HO3508 Auxiliary input: Front side [Rear side] Function External Trigger Impedance 1 MΩ 14 pf ±2 pf Coupling DC, AC Max. input voltage 100 V (DC + peak AC) XYZ-mode: All analog channels on individual choice Invert: CH 1, CH 2 [CH 1 CH 4] Y-bandwidth (-3 db): 300/400/500 MHz (5 mv...5 V) /div. 200 MHz (1 mv, 2 mv) /div. Lower AC bandwidth: 2 Hz Bandwidth limiter (switchable): approx. 20 MHz Rise time (calculated): 300 MHz: < 1.166 ns 400 MHz: < 0.875 ns 500 MHz: < 0.7 ns DC gain accuracy: 2 % of full scale Input sensitivity: 12 calibrated steps CH 1, CH 2 [CH 1 CH 4] 1mV/div. 5V/div. (1 2 5 Stepping) Variable Between calibrated steps Inputs CH 1, CH 2 [CH 1 CH 4]: Impedance 1 MΩ II 13 pf ±2 pf (50 Ω switchable) Coupling DC, AC, GND Max. input voltage 1 MΩ: 200 V p, 50 Ω < 5 V rms, max. 30 V p Measuring circuits: Measuring Category 0 Position range: ± 8 divs Offset control: 1 mv, 2 mv ± 0.2 V - 8 div. * sensitivity 5 mv 20 mv ± 1 V - 8 div. * sensitivity 50 mv ± 2.5 V - 8 div. * sensitivity 100mV, 200mV ±20V - 8div. * sensitivity 500 mv...5 V ± 50 V - 8 div. * sensitivity Logic channels: With Option HO3508 / HO3516 Select. switching thresholds TTL, CMOS, ECL, 2 x User -2 V +8 V Impedance 100 kω < 4 pf Coupling DC Max. input voltage 40 V (DC + peak AC) Triggering Trigger modes: Auto Triggers automatically even when no trigger event occurs for a certain time Norm Always triggers when a trigger event occurs Single Triggers once on a trigger event Trigger display: LED Trigger sensitivity: Intern 0.8 div. (1 div. for sensitivity < 5 mv / div.) Ext. trigger via Auxiliary Input [Aux. Input rear side] Ext. Sensitivity 0.5 V 10 V pp Trigger level range: With auto level Adjustability of the level between the peak values of the signal Without auto level -8 div. +8 div. External -5 V...+5 V Trigger types: Slope: Slope direction Rising, falling, both Sources CH 1, CH 2, Line, Ext [CH 1 CH 4, Line, Ext.] Coupling Auto level Adjustability of the level between the peak values of the signal, 5 Hz...300/400/400 MHz AC 5 Hz...300/400/400 MHz DC 0...300/400/400 MHz HF 30 khz...300/400/400 MHz LF 0 5 khz, selectable for DC, Auto level Noise rejection (low-pass) 100 MHz, selectable for DC, AC, Auto level Pulse width: Polarity Positive, negative Functions ti>t, ti<t, ti=t, ti/=t, t1<ti<t2, not (t1<ti<t2) Pulse duration 16 ns 8.589 s, resolution 4 ns/1 µs Video Pos./neg. sync. impulse Standards PAL, SECAM, NTSC, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p Fields Upper, lower, both Line All, line number selectable Source CH 1, CH 2, Ext. [CH 1 CH 4] Logic: Logic functions AND, OR, WAHR, UNWAHR mit oder ohne Auswertung der Dauer der Logikverknüpfung Duration functions ti>t, ti<t, ti=t, ti/=t, t1<ti<t2, not (t1<ti<t2), Timeout Duration 4 ns...1 s Source LC0 15 State LC0 15 X, H, L Serial Busses: (Options) I 2 C Start, Stop, ACK, NACK, Address/Data SPI Start, End, Serial Pattern (32Bit) UART/RS232 Startbit, Frame Start, Symbol, Pattern LIN Frame Start, Wake Up, Identifier, Data, Error CAN Frame Start, Frame End, Identifier, Data, Error Trigger Holdoff: 50 ns...>10 s 2 nd Trigger (B): Type Slope trigger Slope direction Rising or falling Min. signal height 0.8 div. Source CH 1, CH 2, Ext. [CH 1...CH 4] Coupling (source B/=A): DC, HF, NR Coupling (source B=A): see trigger A Level (source B/=A): -8 div.. +8 div. (adjustable separately by A) Level (source B=A): see level A Frequency range 0 300 / 400 / 500 MHz Operating modes: Time based 16 ns...8,589 s, resolution 4 ns/1 µs Event based 1 216 Horizontal System Domain representation: Time, Frequency (FFT), Voltage (XY) Representation Time Base: Main-window, main- and zoom-window Memory Zoom: Up to 200,000:1 Time Base: Accuracy 15 ppm Aging ±5 ppm/year Refresh operating modes 1 ns/div. 20 ms/div. Roll operating modes 50 ms/div. 50 s/div. Deskew: -62,5 ns +61,5 ns Step size 500 ps Search functions: Slope, Pulse, Peak, Rise-/Falltime, Runt Marker: up to 8 user definable marker for easy navigation; automatic marker function based on search criteria Digital Storage Sampling rate: Resolution (vertical): Memory: Operation modes: Interpolation: Persistence: Delay pretrigger: posttrigger Display refresh rate: Display: 2 x 2 GSa/s, 1 x 4 GSa/s [4 x 2 GSa/s, 2 x 4 GSa/s] Logic channels: 16 x 1 GSa/s 8 Bit, HiRes 10 Bit 2 x 4 MPts [4 x 4 MPts], 1x 8 MPts [2 x 8 MPts] Refresh, Average (1024), Envelope, Peak-Detect (500ps), Filter, Rol (free run/ triggered from time base 50 ms/div. and slower), HiRes CH 1...CH 4: Sinx/x, Pulse, Linear; LC0...15: Pulse Off, 50 ms 0 4 Million x (1/samplerate), Interlaced x2 0 8,59 Billion x (1/samplerate) Up to 5,000 waveforms/s Dots, vectors (interpolation), persistence Operation/Measuring/Interfaces Operation: Menu-driven (multilingual), Autoset, help functions (multilingual) Frequency counter: 0.5 Hz 300/400/500 MHz 6 Digit resolution Accuracy 15 ppm Aging ±5 ppm/year

Auto measurements: Statistic Cursor measurements: Application memory: Interface: Internal Exchangeable Video OUT: Trigger OUT: Optional: Mathematic functions Quickmath: Editor for formula sets: Label for: Sources: Targets: Functions: Display: Mask test: Quickview: V pp, V p+, V p-, V rms, V avg, V top, V base, amplitude, phase, frequency, period, risetime 80 / 90 %, falltime 80 / 90 %, pos./neg. pulse width, pos./neg. duty cycle, standard deviation, delay, pos./neg. edge count, pos./neg. pulse count, trigger period, trigger frequency Min., max., mean, standard deviation, number of measurements for up to 6 Functions simultaneously V, t, 1/ t (f), V to GND, Vt related to Trigger point, ratio X and Y, pulse count, edge count, peak to peak, peak+, peak-, mean value, RMS value, standard deviation, rise time, duty cycle 8 MByte for references, device settings and formulars 2x USB-Host (type A) (1x front side, 1x rear side), Mass storage (FAT16/32) HO730 Dual-Interface Ethernet/USB- Device/RS-232 (type B) DVI-D (480 p, 60 Hz) for external display, HDMI compatible BNC (rear side), Modes: Trigger, Mask USB-Device/RS-232 Dual-Interface (HO720), IEEE-488 (GPIB) Interface (HO740) ADD, SUB, MUL, DIV Max. 5 formulas per formula set Math. memories All channels and math. Memories, constants Math. memories ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS, NEG, INV, SQR, MIN, MAX, LOG 10, LN, Integral, Differential, High-pass filter, Low-pass filter Up to 4 math. memories with label Signal test (pass/fail) based on previously defined mask Display of V p+, V p-, RMS value, rise time, fall time General Information Probe ADJ Output: 1 khz/1mhz square wave signal approx. 0,2V pp (ta <4 ns) Bus Signal Source (4Bit): SPI, I 2 C, UART, retangle, 4Bit counter, 4 Bit random pattern Internal RTC (Realtime clock): Date and time for stored data Power consumption: 100...240 V, AC 50 60 Hz, CAT II Protective system: Max. 70 [90] W Protective system: Safety class I (EN61010-1), CSA (pending) Operating temperature: +5 +40 C Storage temperature: -20 +70 C Rel. humidity: 5 80 % (non condensing) Theft protection: Kensington Lock Dimensions (W x H x D): 285 x 175 x 220 mm Weight: 3.6 kg All data valid at 23 C after 30 minute warm-up. Accessories supplied: Line cord, printed operating manual, 2 [4] Probes, 10:1 with attenuation ID (HZ350 400/300MHz, HZ355 500MHz), Software-CD Recommended accessories: HOO10 Serial bus trigger and hardware accelerated decode, I 2 C, SPI, UART/RS-232 on Analog channels and Logic channel HOO11 Serial bus trigger and hardware accelerated decode, I 2 C, SPI, UART/RS-232 on Analog channels HOO12 Serial bus trigger and hardware accelerated decode, CAN, LIN on Logic channels and Analog channels HO3508 Active 8 Channel Logic Probe HO3516 2 x HO3508, active 8 Channel Logic Probes HO720 Dual-Interface USB-Device/RS-232 HO740 Interface IEEE-488 (GPIB), galvanically isolated HZ46 4RU 19" Rackmount Kit HZ99 Carrying Case for protection and transport HZ355 Slimline Probe 10:1 with automatic identification HZ355DU Upgrade from 2 x HZ350 to 2 x HZ355 HZO20 High voltage probe 1000:1 (400MHz, 1000Vrms) HZO30 Active probe 1GHz (0.9pF, 1MΩ, including many accessories) HZO40 Active differential Probe 200MHz (10:1, 3,5pF, 1MΩ) HZO41 Active differential Probe 800MHz (10:1, 1pF, 200kΩ) HZO50 AC/DC Current probe 30A, DC 100kHz HZO51 AC/DC Current probe 100/1000A, DC 20kHz Accessories Carrying Case HZ99 Active Probe HZO30 HOO10/HOO11 SPI / I 2 C / UART Bus Analysis for all Oscilloscopes of the HMO Series SPI Bus Trigger Setup I 2 C Bus Hex Decoding on the Analog Channel HOO12 CAN/LIN Bus Analysis for all Oscilloscopes of the HMO Series I 2 C Bus ASCII und Binäry 8 Channel Logic Probe HO3508 CAN Bus Configuration CAN Bus List Display CAN Bus Hex

new!! the hmo 3000 SerieS Bandwidth Upgrade to 500 Mhz available at any time Please visit our website for further details and technical data or scan the Qr code Great Value in test & Measurement 02 / 2013 Subject to change without notice www.hameg.com blog.hameg.com hameg instruments Gmbh industriestr. 6 63533 Mainhausen Germany tel +49 (0) 6182 8000