SERVICE 1 A2 KEY TELEPHONE SYSTEM PANELS 601-, 602-, AND 603-TYPE

Similar documents
SPEAKERPHONE SYSTEM-3-TYPE 630-TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE

400A, 8, C, AND D TYPE KEY TELEPHONE UNITS IDENTIFICATION, INSTALLATION, CONNECTIONS, AND MAINTENANCE

400A, B, C, AND D TYPE KEY TELEPHONE UNITS IDENTIFICATION, INSTALLATION, CONNECTIONS, AND MAINTENANCE

REFERENCE 2750-TYPE TELEPHONE SETS

VOICE CONNECTING ARRANGEMENTS RDL AND ROM KS-19522, LIST 1 OR LIST 2 RECORDER COUPLER USED WITH KS-16765, LIST 1 ANNOUNCEMENT SET

INTERFACE TERMINATION JTC USED WITH ATTESTED CUSTOMER-PROVIDED NON-POWERED CONFERENCING DEVICES

TONE COMMANDER SYSTEMS, INC l'oth Ave. N.E., Redmond, WA 980'2, U.s.A Telephone: (206) , Telex:

1A AND l Al KEY TELEPHONE SYSTEM

No. 122 supplement - (Vol.VII) October 1996

Conettix D6600/D6100IPv6 Communications Receiver/Gateway Quick Start

V-136RT 36 STATION ROTARY-TONE INTERCOM

KEY SYSTEMS SERVICE MANUAL

A. E. CO. TYPE 10A2 KEY TELEPHONE SYSTEM DESCRIPTION AND OPERATION PAGE

Selection guide siemens.com/sirius-modular-system

RISER AND DISTRIBUTION TERMINALS

PARTS LIST. WJoJ.J. ~ l 7041 LPW-27BK. 28BK LPW-27BL K. 28BLK -- --, l I 10571

Example Transport Engineering Guide (TEG): Artel DL1220 and DL2701 Broadcast Video -48VDC applications

Contactors and Contactor Assemblies

A Versatile New Intercom System

CONNECTOR CABLES IDENTIFICATION

Quick Q. Supervisor s User Guide for the Scout II Telephone

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

BOTC-TEG-8500 Example Transport Engineering Guide (TEG): Video Products Group Inc (VPG) Ventura Broadcast Video -48VDC applications

APPENDIX A Verify All Part Numbers (Partial List of Approved Products)

video door entry system - installation instructions

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Introduction and Definitions

Example Transport Engineering Guide (TEG): DSX-1 Rear Cross Connect

Safe Enclosure Cooling

SECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

S Micro--Strip Tool in. S Combination Strip Tool ( ) S Cable Holder Assembly (Used only

Spare Parts, Accessories, Consumable Material for Older Design Recorders

) AMANO. ,i CINCINNATI ELECTRONIC TIME RECORDER EX 6000 SERIES

CAT Extender. EXT-CAT User Manual.

Technical Note

USER S MANUAL (1/2) (Functions and connections)

Bulletin 509 Full Voltage

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

HYPERLINE UTP/STP Cable Strippers and Cutters

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"

EY-000 SECURITY ABBREVIATIONS, NOTES, SYMBOLS, CONDUIT & CABLE DESIGNATIONS STC STC. tel: fax: web: trcsolutions.

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

Installer Manual Video door entry unit with 3.5" monitor for Due Fili (Two-Wire) call system Elvox Vimar Group.

Pushbutton Units and Indicator Lights

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

www. ElectricalPartManuals. com l Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

Inside Moves - Transfer of existing service or equipment from one location to another on the same premises and in the same building.

OPERATING INSTRUCTIONS

Certificate of Calibration

Iu Greensleeves Variants Robert E. Foster (ASCAP) j r. n r^ni. ^rtr. m ^Tn * ^ $ n~n. Boldly (J = ) (2+2+3) Boldly (J = )

Kinetix Application Note

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

Example Transport Engineering Guide (TEG): DSX-3 Rear Cross Connect

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Rack mounted telephone- and leased line modem for industrial applications

15A Announcement System Description and Operating Procedures Common Systems

16A Announcement System Description and Operating Procedures

V DD V DD V CC V GH- V EE

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Table of Contents/Quality and Reliability

Concertino. Paul Creston

Exercise 2-1. External Call Answering and Termination EXERCISE OBJECTIVE

KS-19245, LIST 1 TELEPHONE ANSWERING SET MECHANICAL ADJUSTMENT AND MAINTENANCE

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Church Layout Medium Advanced

Coastal Amusements, Inc Swarthmore Ave. Lakewood, NJ (732)

Instructions for Contributors to the International Journal of Microwave and Wireless Technologies

~ - -- ~- ----"""",."",."""~""""""""",,,,- - -(- WH I T E ~;stes Avenue, Elk Grove Village, IL # ~..

6A KEY TELEPHONE SYSTEM IDENTIFICATION AND INSTALLATION

YS1000 Series. Compatible Type for Pneumatic 100 Line (with YS100 Terminal)

USER'S MANUAL. Getting started with ALEXAN ATMEL AT89C2051/AT89C4051 Training Module - 1

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Output Board - v2* 4.1 Overview. 4.2 Audio Circuitry Program and Audition Outputs

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

NORTHERN~ TELECOM~ Contents. Switching Products. a Northern Electric company. TSO Section 4

Column Type Air Micrometer. CAG2000 Instruction Manual

SITE All work shall be performed at Center Park Substation (1895 Kernan Blvd, Jacksonville, Fl ). DATE: 04/03/2018

AIR 2 + RADIO CONSOLE

SPECIFICATION SHEET lumencove

Model /29S RF Splitter

PREPAX DELUXE INTERCOM SYSTEMS

4. Alignment and Adjustments

MiniSafe Light Curtains

Lessons On Movies.com

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

AMP DISPLAY INC. SPECIFICATIONS AMP DISPLAY INC 9856 SIXTH STREET RANCHO CUCAMONGA CA TEL: FAX:

Table of Contents TelcordiaSR-307 Documentation Information

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Model 1476-C SuperQuad HR

GP-500 SERIES - Low Voltage

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Systems Pow-R Breakers Renewal Parts and Accessories

TeleHawk Door entry system

Type MG-6 Auxiliary Relay Class 1E

By Room, Date, and Time Director

Product G e n e r a l S p e c i f i c a t i o n

USER INSTRUCTIONS SSA-424 DUAL DIGITAL HYBRID ADAM, ADAM CS, AND ZEUS INTERCOM SYSTEMS

Switching and Telephone Products KEY TELEPHONE SYSTEM HANDBOOK

Transcription:

BELL SYSTEM PRACTCES AT&TCo Standard SECTON 518-215-411 ssue 2, November 1971 SERVCE 1 A2 KEY TELEPHONE SYSTEM PANELS 601-, 602-, AND 603-TYPE 1. GENERAL 1.01 The 601A, 602A, and 603A (Fig. 1, 2, and 3) panels provide auxiliary mounting facilities for the 400 series key telephone units required to provide basic dial intercom, deluxe dial intercom, and intercom TOUCH-TONE calling, respectively. e Add identification and installation information formerly contained in Section 518-215-118 which is hereby canceled. Since this reissue covers a general revision, arrows ordinarily used to indicate changes have been omitted. 1.02 This section is reissued to: e Cover complete redesign of factory wiring within the panels Caution: ssue 1 of this section and ssue 2 of Section 518-215 118 cannot be used for identijication, installation, and connections of 601A, 602A, and 603A panels. Fig. 11A Panel @) American Telephone and Telegraph Company, 1971 Printed in U.S.A. P...-1 BSP 518-215-418-i02_1971-11-0l.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock. :.., C;;.;; lo;;.;; o;;.;; ra ;;;. do ;...; O ;.;; c.;.; t 1 ;.;; 5 " ", 2 ;;.;; 0.;;. 12;;..;;. 11 "-' "-' : 24 ;.;. :4 ;.;; 8

SECTON 518-215-418 Fig. 2-602A Panel 1.03 This issue of the section is based on the following drawings: SD-69608-01, ssue 3-Station Systems, Key Telephone System No. 1A 2, Dial ntercommunicating and Miscellaneous Panels SD-69567-01, ssue 8-Station Systems, Key Telephone System No. 1A2, Dial Selective ntercommunicating Line Circuit. f this section is to be used with equipment or apparatus reflecting later issues of the drawings, reference should be made to the SDs to determine the extent of the changes and the manner in which the section may be affected. 1.04 Basic Dial ntercom: A station (on pickup) is connected to a common talking path which is part of the selector circuit. Station selection is Fig. 3-603A Panel Page 2 BSP 518 215 418 i02_1971 11 02.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:25:07

SS 2, SECTON 518-215-418 then accomplished by dialing one digit (for 10-station selector) or two digits (for 19-station selector). 1.05 Deluxe Dial ntercom: Same as basic dial intercom plus flashing lamps on incoming calls, dial tone, station busy tone, audible ringback tone, and interrupted ringing. 2. DENTFCATON PURPOSE DESGN FEATURES (a) Can be installed on a 23-inch relay rack by using a 99A (MD) or 99B bracket or in a 16-type apparatus mounting. (b) (c) Four No. 8-32 RHM mounting screws are furnished with each panel. A retainer is provided to lock the KTUs in the connectors. n 1A2 Key Telephone System arrangements to provide auxiliary mounting facilities for 584-type panels in large centralized installations. 601A Panel (d) Arranged to mount three basic dial intercom circuits (Table A). ORDERNG GUDE 602Panel Panel, 601A Panel, 602A (e) Arranged to mount one deluxe dial intercom circuit (Table A). Panel, 603A (a) Replaceable Components Fuse, 24C (2A)* Fuse, 24E (112A)* Fuse, 24G (1-1/3A) t For 601 and 602A panels. 60JA and 602A Panels (f) Factory wiring is provided from the connectors to the jacks. This permits use of connector cables for line and station terminations. (g) Connecting block on panel for terminating power, option, and TOUCH-TONE leads. (h) Fuse panel provided with 24-type fuses for power distribution (Table B). t For 602A panel only. (b) Associated Apparatus (Order Separately) (i) Dimensions are 6 inches wide by 8 inches high. Block, Connecting, 66B4-25 (as required) Cable, Connector, A25B, A50B, or A75A (as required) Mounting, Apparatus, 69B or 69D (as required, order per Table A) Unit, Telephone, Key (as required, order per Table A) 1A1 Matrix Block 603A Panel (j) Designed to mount 426A and 427B (Series 4) or C KTUs (Table A) to provide TOUCH-TONE calling in 601A and 602A panels. (k) Eq uipped with a 5-foot cable stub for connecting to the 601A or 602A panel. () Dimensions are 4-112 inches wide by 8 inches high. Page 3 BSP 518 215 418 i02_1971 11 03.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:25:34

SECTON 518-215-418 TABLE A DAL NTERCOM FUNCTON PANELS APPARATUS * MOUNTNGS KTU 601A 602A 603A 698 69D 407B 10-Code Selector Circuit 413A Auxiliary Ringup Circuit 420A Long Line Circuit 421A Transfer Circuit (for DSS) t 422B Station Busy Selector Circuit Dial Tone, Busy Tone, and 423A Audible Ringback Tone Circuit 424A 19-Code Selector Circuit 425B Flashing Lamp Circuit 426A & 427B (Series 4) or C TOUCH-TONE Adapter Circuit * The 69-type apparatus mountings and associated KTUs provide optional features for the dial intercom systems. See Fig. 4 through 13 for additional information. t f interrupted signal for intercom differs from that provided by existing panel interrupter, a separate 421A KTU and 69D apparatus mounting must be provided. TABLE B FUSE FUNCTONS FOR 601A AND 602A PANELS FUSE PANEL SZE CODE SERVED ± 10V ± 1sv sst ABAT, BBAT, F1 1/2A 24E J1A&B F2 2A 24C F3 1/2A 24E J2A&B 601A F4 2A 24C F5 1/2A 24E J3A&B F6 2A 24C F1 1-1/3A 24G J3A&B* F2 1-1/3A 24G Serves all conn 602A F3 1/2A 24E J3A&B F4 1/2A 24E J1B F5 2A 24C J3A&B * Also serves 603A panel. t May be.±10v, -24V, ±18V, or ±105V, depending on option provided. Page 4 BSP 518-215-418-i02_1971-11-04.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:25:51

SS 2, SECTON 518-215-418 3. NSTALLATON 3.01 For information on apparatus mountings and relay racks, refer to Section 463-140-100. 3.02 Fig. 4 through 13 show panel and connecting block layouts for 601A, 602A, and 603A panels. 3.03 When a 424A KTU (19-code circuit) is used in the 602A panel, an additional 422B KTU, 69D apparatus mounting, an A25B connector cable, and a 66B4-25 connecting block are required. (See Fig. 9 for layout.) Note: A separate 421A KTU must be provided in a 69D apparatus mounting if interrupted signal for intercom differs from that provided by existing panel interrupter (see Fig. 8 and 9 for layout) 3.04 Panel and connecting block layouts are shown for optional features such as preset conference, DSS, and long line circuits. These configurations require additional 66-type connecting blocks, connector cables, 69-type apparatus mountings, and KTUs. (See Fig. 6, 7, 10, 11, and 12, whichever apply, for layouts of these options.) 3.05 nstall panels on relay rack or 16-type apparatus mountings in the usual manner. A 99A (MD) or 99B bracket must be used when installing the panels on a relay rack. 3.06 nstall 69-type apparatus mountings (if required). 3.07 nstall 66B4-25 connecting blocks and stencil each block as required (Fig. 4 through 12). 601A and 602A Panels 3.08 nstall A25B connector cables from panels to connecting blocks. Note: A75A and A50B connector cables can also be used to connect 601A and 602A panels, respectively, to the connecting blocks. When using the A 75A connector cable, the conductors in the BL-W, 0-W, and G-W binders are terminated on connecting blocks 1, 2, and 3, respectively. When using the A50B connector cable, terminate the conductors in the BlrW and 0-W binder on connecting blocks 1 and 2, respectively. 3.09 After all other panel connections have been made, use 20-gauge strapping wire to terminate power leads to connecting block on the panel. Strip ends of wire and be careful to avoid shorting adjacent terminals; then, connect power leads to the power supply provided for the 584 type panels. 3.10 nstall key telephone units. 3.11 Make certain fuses are properly installed and not blown after power leads have been terminated. 603A Panel 3.12 Terminate free end of cable stub on connecting block located on 601A (Fig. 15) or 602A (Fig. 23) panel. Do not cut cable stub. 3.13 nstall key telephone units. 4. ECTONS 4.01 Fig. 14 and 22 show the connections of A25B connector cables to 66B4-25 connecting blocks for 601A and 602A panels, respectively. 4.02 The method of terminating leads on the 66B4-25 connecting block is shown below: COL.B,C,D,f 6684-25 BLK LEFT HAND BLK 6684-25 BLK RGHT HAND BlK lq:bqjj COL F,E,O,C,B TO STATONS TO TO TO STATONS V A CROSS PANEL PANEL VA CROSS ECTONS ECTONS AS REQURED AS REQURED Page 5 BSP S18215418i02 19711105.jpg Scanned by Fcank Harrell, Cowboy Fcank) Castle Rock, Colocado Oct 15, 2012 11:26:13

SECTON 511-215-418 4.03 TOUCH-TONE (603A panel), power, interrupter and option connections for the 601A, and 602A panels are shown in Fig. 15 and 23, respectively. These connections should be made on the 66T1 connecting block located on the panel before installing KTUs. 4.04 Fig. 14 through 31 cover station connections, option connections, basic dial intercom, deluxe dial intercom, and 603A panel connections. Do not cut cable tail on 603A panel. Store excess length by dr essing in place. ECTON NDEX 601A Panel (Basic Dial ntercom) Fig. 14-A25B Connector Cables to 66B4-25 Connecting Blocks Fig. 15--Power Leads, Option Strapping, and TOUCH-TONE Connections Fig. 16-424A KTU-Transfer Digit Lead Connections Fig. 17--407B KTU-Station Connections Fig. 18-424A KTU-Station Connections Fig. 19--420A KTU, Long Line Circuit Mounted in 69B Apparatus Mounting Fig. 20--421A KTU Arranged for DSS Mounted in 69B Apparatus Mounting Fig. 21-1A1 Matrix Block, Optional Dial Selected Preset Conference 602A Panel (Deluxe Dial ntercom) Fig. 22-A25B Connector Cables to 66B4-25 Connecting Blocks Fig. 23-Power and nterrupter Leads, Option Strapping, and TOUCH-TONE Connections Fig. 24-424A KTU-Transfer Digit Lead Connections Fig. 25--422B KTU-X1-XO, Station Busy Selector Circuit for Adding Tens Group and Optional 421A KTU to Provide nterrupted Signaling Fig. 26--407B KTU, Station Connections Fig. 27--424A KTU, Station Connections Fig. 28-420A KTU, Long Line Circuit-Mounted in 69B Apparatus Mounting Fig. 29-421A KTU Arranged for DSS Mounted in 69D Apparatus Mounting Fig. 30--421A and 413A KTUs, Preset Conference Circuit Mounted in 69D Apparatus Mounting, and 1A1 Matrix Block Fig. 31--421A KTU, Preset Conference Circuit Mounted in 69D Apparatus Mounting 5. REFERENCES 5.01 For additional information, refer to the following: e Section 518-010.101 Centralized Key Telephone nstallations e Section 518-215-400 Service, 1A2 KTS Key Telephone Units, 400 Series. e Section 518-215-410, Service, 1A2 KTS, Panels, 583-and 584-Type e Section 461-620-100, Matrix Block-1A1, dentification, nstallation, Wiring and Maintenance Page 6 BSP 518-215-418-i02_1971-11-06.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock. :.;, C o.;;; lo ;;.;;; ra do ;...;; ;; l 5,.;; 20 ;.; 1 ;;;. 2..;; 1 ;;;. 1: ;;;. 26 ;.; :3 ;;.; 1 ;... O.;;.; ct.;;.;;.;

60 A PANEL r - - - -- ----r---- --------------1 oe- - oe 1 4 7 J J A J2 A J3A 1 SS 2, SECTON 518-215-418 1- L------- A2 5B CABLES BLK BLK 2 NOTE: 6684-2!5 ECTNG BLOCKS SEE FG.7 FOR ECTONS Fig. 4-601A Panel and Conneding Block Layout with Three 407B KTUs 601A PANEL ------,--, 4 _ L 2 _ L 2 _j J A J2 A J3A 1 1 1 L _1. _j L BLK BLK 2 NOTE: SEE FG. 18 FOR ECTONS. BLK 3 BLK 4 6684-25 ECTNG BLOCKS Fig. 01A Panel and Conneding Block Layout with Three 424A KTUs Page 7 BSP 518-215-418-i02_1971-11-07.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:26:51

SECTON 518-215-418 SOA PANEL [ 082 :40 _ 0;; JA J2A J3A 66T 8LK l 690 APPARATUS MOUNT lng,--, _J A L j STRAPS BLK BLK 2 8LK 3 BLK 4 TO POWER SUPPLY 6684-25 ECTNG BLOCKS NOTE: SEE FG. 20 FOR ECT ONS. Fig. 6--601A Panel and Conneding Block Layout with Optional DSS Circuit Page 8 BSP 518-215-418-i02 1971-11-0B.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:27:10

SS 2, SECTON S18-215-418 698 APPARATUS MOUNT lng l4zca-; L- _j A L j t STRAPS BLK BLK 3 BLK 4 TO POWER SUPPLY STRAPS ll 6684-25 ECTNG BLOCKS ll SEE FG. 19 FOR ECTONS TO LONG LNE CRCUT. t SEE FG. 21 FOR ECTONS TO PRESET CONFERENCE CRCUT. Fig. 701A Panel and Connecting Block Layout with Optional Long Line Circuit or Preset Conference Circuit Page 9 BSP 518-215-418-i02_1971-11-09.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:27:30

SECTON 518-215-418 602A PANEL r -- - - - - ----- - -, - -- - - - -, - : : ::: : 425B i 407B : - - - t t- - la - - - J2A J3A - - 69D APPARATUS MOUNTNG r--- ---, : 421A(B) : r---- ----- JB 0 1---- _j_-- J2B 0 B - ; L _.J A2B CABLES ---,,----...j BLK SEE NOTE) BLK 2 NOTE: THS CABLE AND CCNN BLK ARE NOT REQURED WHEN THE 407B KTU S USED WTHOUT STATON BUSY OPTON BLK 3 66B4-2 BLKS NOTE: SEE FG. 25 AND 26 FOR ECTONS Fig. 8-602A Panel and Connecting Block Layout with 4078 KTU (10-Code Circuit) Page 10 BSP 518-215-418-i02 1971-11-10.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:27:48

SS 2, SECTON 518-215-418 690 APPARATUS MOUNTNG 1422B(A)l 421AB) CN-; L STRAP BLK 2 BLK 4 TO POWER SUPPLY STRAPS 66B'4-25 ECTNG BLOCKS NOTE: SEE FG. 25 AND 27 FOR ECTONS. Fig. 9-602A Panel and Conneding Block Layout with 424A KTU (19-Code Circuit) 690 APPARATUS MOUNT lng,-;l ----1 L J STRAPS A25B CABLE BLK 3 66B4-25 ECT! NG BLOCKS NOT E: SEE FG. 29 FOR ECTONS. Fig. 10--602A Panel and Conneding Block Layout with Optional DSS Circuit Page 11 BSP 518-215-418-i02_1971-11-ll.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock., C;;; o;.;; ; lo ; r;;;.; ad;.;o;...;; O'-"c t;;; l;.;s._, 20 ;;; ;.; 1 ; ;; 2 - '1;.; ;; 1 :2 ;.; 8;;; :0;. 6 ;

SECTON 518-215-418 690 APPARATUS MOUNT NG f"" 4l1AlAll L J A STRAPS * io----jo- A25B CABLES CABLES BLK STRAPS 6684-25 ECTNG BLOCKS NOTE' SEE FG. 30 FOR ECTONS FOR DAL SELECTED PRESET CONFERENCE AND FG. 31 FOR ECTONS FOR SGNAL KEY OPERATED PRESET CONFERENCE. *NOT REQURED FOR SGNAL KEY OPERATED PRESET CONFERENCE Fig. 1102A Panel and Connecting Block Layout with Optional Preset Conference Circuit Page 12 BSP 518-215-418-i02_1971-11-12.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:28:25

SS 2, SECTON 518-215-418 602A PANEL 1422B Ti iai 2-4 8/424 2 _i:j -l- j J2A JB J2B 0 0 L 698 APPARATUS r'-oj!!t llig 420A N;; A L j BLK31 STRAP t STRAP * NOTE: SEE FG.28 FOR ECTONS. *F USNG 4078 KTU t f USNG 424A KTU 6684-25 ECTNG BLOCKS Fig. 12---602A Panel and Connecting Block Layout with Optional Long Line Circuit L--------'-- ------l TO BLK ON 601A OR 602A PANEL Fig. 13-603A Panel Layout Page 13 BSP 518 215 418 i02 1971 11 13.jpg Scanned by Frank Harrell, Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:28:44

;;o SECTON 518-215-418 6664-2 5 BLK 6664-2 5 BLKS AND 3 BLK LEfT HAND BLK AMPHENOL 5 BLK 2 A2 5B A e c D E P P3 P2 A2 5B RGHT HAND BLK r CABLE 601A PANEL A8CD fl RG,.,..-, / (W-BL) R "-- 1 rb- f---2 1- - - -T.B'CL'o- '--f-1--t-? 6 )..;_ Tw R2 f---4-t o-w RG T W-G C 7 (o-w) lr-lf- - 'R'-" 2 -- := W-G -4-+-4--- RG C ;e (G-W) -?-+4---f--'R'-"3-- =-= (W-BR) +-f--'r"'g-- = BR-W R4 w-5,_lf--' R'7G-- RG +r-t-r--r.w,_--:':o -T--- - f- + +-7 2 27 E RG 1--j-'i-T- - -,( ro R :o' -B ':'i L Cf ) - -f-++7 31 '-'- R6 r-tlf2 BL-R RG 1t3 ""T3 R-0 )..;_ 2 '-'- RG 'SS R-G R8 f-j6i5 G-R 33 RG T7 -;7 R-BR C.::: (..; R9 RG jgf-jt R-S 4 >+- RO zof--20 S-R RG -z-lrt- BK-BL O RX 36 C.::: RG --23 BK-0 '--.. 37 12 E RX3 fs-fk G-BK RG --z7'z7 BK-BR RX4 39 zscu RG "29'29 BK-S RX5 ftc"- S-BK RG 3if31" Y-BL RX6 3"2'32 BL-Y 41 :: ; RG )3 Y-O 16 C.:: RX7 it-lit 0-Y 42 )::;::= 17 >-t- RX8 36r)s- G-Y RG 37 Y-BR 44 RX9 38 BR-Y R7 r-;4 t" O-R) 7 (..; Te S uf22 BR-R BL-BK RX2 24'24 0-BK RG t--t.bk"- G r -+-r+ S )-J- BR-BK 14 -... RG 3srt5- Y-G <... "' 0 >-- / CABLE c: 6 tt+-t< - ----7 1/ (W-BL) -:-r- RG ;cbl -=-.;cw;--; R ; : w-o -4-+ - f--'r'-':g-- 0 (5-W) +o-f--' 3 1 ( R-BL r-tl 'll rc R (BL-R) f---'-7-r,-;;-- R6 j3 3 G-R R8 R-BR RG R'-" 5-- G :- - - --r.; 2 = Ptdf=-;:;:::;--- :::1::5 7 R-G eli- RG S 44 Y-BR?-#-- RG BR-Y,li Jl_t-;:.RX ": 9,.-- 19 Y-5 -#---#- RG 20 S-Y #-t-;:.rx::,0,.-- 46 Y-BL 4$- T 21 BL-Y R Y-u. 1-T,LG;;--- -+< o-y L 48 f++t---t.y0:: G-Y _7T".----i 1-.;ro=--- J 45 49 BR-Y _g._ _ TTG ::::5 2 3 Y-BR.!g_-B'Y::c--- 24 Y-S.ll.._ SPARE SO S-Y SPARE 25 22... 2Q_ Fig. 14--601A Panel, Connection of A25B Connector Cables to 6684-25 Connecting Blocks Page 14 BSP S18-215-418-i02_1971-11-14.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:29:02

SS 2, SECTON 518-215-418 603A (W-BL) T PANEL (BL-W) R @ OPTON (W-0) Yl lone REO'O FOR EACH (o- w) Y2 NTERCOM (w-g) THAT S!NOTE ) 'TOUCH- (G-W) Y4 TONE" (W-BR) YS EQUPPED) -- (BR-W) RH 426A AND (w-s) TTG 4278 SERES 4, (S-W) A BAT OR C KTU'S (R-BL) CG MUST BE LOCALLY (BL-R) RS FURNSHED NSULATE AND STORE SPARE LEADS Y3 NOTES:. TERMNATONS AND OPTONS SHOWN N COLUMNS C, 8 AND A ARE DEDCATED TO 603A PANELS USED WTH NTERCOM CRCUTS N JACKS Jl, J2 AND J3 RESPECTVELY. 2. USE 20 GAUGE STRAPPNG WRE!STRP WRE BEFORE TERMNATNG ON ECTNG BLOCK) FOR POWER COHtjECTONS. TO AVOD SHORTS, NAKE ECTONS ON 60 A PANEL CCT G BLOCK BErORE CONECT NG TO POW!:R SUPPLY. 3.([)STRAP NUST BE RENOVED 1r 42H KTU S USED. 4. (j2 STRAP MUST BE REMOVED F TOUCH-TONE11 S USED. *FOR NTERCOM CRCUT N JACK t FOR NTERCOM CRCUT N JACK 2 FOR NTERCOM CRCUT N JACK 3 66T BLOCK ON 60 A PANEL AJ3) BJ2) CJ) Dl * Dl t D" SPARE ss* FOR FUTURE USE -24V DC 1 @ 105V! 0 tovt.or rev± RG rov:t LG TO POWER SUPPLY FOR 584- TYPE PANEL!NOTE 2) -24V A BAT. A GRO OPTONS J AC BUZZER OR BELL TYPE DC BUZZER OR BELL AUDBLE M RNGER SGNAL N WTH "TOUCH TONE" z WTHOUT 11TOUCH-TONE" FACTOR Y F 407B KTU USED FURNSHED 13 14-24V B BAT. B GRD Fig. 15-601A Panel, Connedlons of Power Leads, Option Strapping, and TOUCH-TONE Page 15 SSP 518-215-418-i02 1971-11-1S."p Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:29:21

SECTON 518-215-418 6664 25 BLK BLKS AND 3 6684 25 BLK BLK 2 NOTE' ANY SELECTED Dl GT MAY BE MADE THE N TAL DGT or THE T\10 DGT DAL CODE. STRAP THE R LEAD Or THE SELECTED DGT TO THE TO LEAD. THE DGT SO ASS GNED CANNOT BE USED ror A STATON CODE. (SEE NOTE) 45A 45r (SEE NOTE) Fig. 16-601A Panel, 424A KTU Connedion of Transfer Digit Lead Page 16 BSP S18-215-418-i02_1971-11-16.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:29:40

SS 2, SECTON 518-215-418 ll STATON NUMBER ( 21 131 141 151 161 171 18 191 101 BLOCK ROW AND COLUMN ASSGNMENT for STATONS TO TEL SET V A CROSS- St A TO AUO SG V la CROSS- S [ R A 2A 8 8 41 E 1426 B BE A ffij A BE A 8 ] ] 36E 134A B STRAPlf STRAP* 140A 1408 l4oc l4oo 40E STRAPlf STRAPlf 66B4-25 BLOCK, AND 3, STRAP* STRAP* LEFT HANO BLOCKS* 32E STRAP* STRAP* 28E lzsa BLOCKS 132A 5!] 130A A llib A 8lli A 8lli A ------------------------------ Bill A l3oe Bill A 41B 366 134F STRAP* STRAPlf TO 426 [40F 140E l4oo [4oc 408 TEL SET STRAP* STRAP* 6664-25 VA CROSS- S 143E 2BB BLOCK, BLOCK 2, STRAPlf STRAP* RGHT HAND TO AUO SG CROSS- S 44B 3 28 130E STRAPlf STRAP* [ B8 B8 BB r r llib r llib r llib ffib V la r r r r lf USE CONTNUOUS METHOD or STRAPPNG. THS REPRESENTS ECTONS for TWO 407B KTUS SEE fig. 4 for PANEL AND ECTNG BLOCK LAYOUT Fig. 17-601A Panel, 4078 KTU, Station Connections via Cross-Connections for Basic Diol ntercom Page 17 BSP 518-215-418-i02_1971-11-17.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:29:58

SECTON 518-215-418 TO TEL SET VA CROSS S STA T1 ON NUMBER () ( 2) ( 3) (4) (5) (6) (7) ( 8) Gb 00 BLOCK ROW AND COLUMN ASSGNMENTS FOR STATONS STRAP (SEE NOTE) STRAP (SEE NOTE) (9) (0) STRAP 114Flll STRAP SET VA TO AUD [ SG VA GQ STRAP STRAP (SEE NOTE) EJ 12!lr* 129Ell 129Dll 129Cll STRAP (SEE NOTE) l"3rl l5rl ;- 0 STRAP l22r*22e* STRAP lzsn+ 126E * SH TO 2 STRAP lw*ll3o E * STRAP TO AUD SG VA CROSS $ TO TEL CROSS $ TO TEL SET VA CROSS $ TO AUD SG VA CROSS $ r l NOTE: lmll3mii37dm137clll STRAP (SEE NOTE G:_U[i;] 13sr* 1138E* STRAP r:;:;-;:;;1 r:;:;;::;-j TO SH 2 STRAP 46r* 6Elll STRAP USE CONTNUOUS METHOD or STRAPPNG, ll DENOTES ECTONS TO BE MADE ON BLOCK 4 t 'SEE FG. 16 FOR TRANSFER DGT ECTONS. t SEE FG.!5 FOR PANEL AND ECTNG BLOCK LAYOUT Fig. 101A Panel, 424A KTU, Station Connections via Cross-Connections for Basic Dial ntercom (Sheet 1) Page 18 BSP 518-215-418-i02_1971-11-18.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:30:18

SS 2, SECTON 518-215-418 STATON NUMBER (X ) (X2l (X3) (X4) (XSl (X6) ( X7) ( X6) BLOCK ROll ANO COLUMN ASSGNMENTS FOR STATONS ( X9) (X O) STRAP STRAP 0 G G STRAP 0 0 STRAP 0 0 0 STRAP STRAP FROM 66B4 25 SH B B B STRAP STRAP STRAP STRAP STRAP E) 8 STRAP A ffi8 A A ffia 30A ffi8 A A ffibffib 38A ffi8 A ffi8 ffib ffi8 --------------------------------- - --- STRAP STRAP 2or l 2oE l2oo l 2oc l STRAP l22o l lzzc l STRAP 23F 23E 23011 23c l STRAP 24F l2ml 1240*1 24C STRAP STRAP STRAP STRAP 66B4-25 BLOCK, BLOCKS 2 AND 4 + STRAP STRAP STRAP r r ffi8 r ffibffib 30F ffi8 r r lliaffib 38F ffi8 r FROM SH 1 26o l lzsc11 27 F 127E l21o11l 27C 128Flll 2m 120111 12sc l 13oo l 130C 32F 132E l32o11l 132Cl! ffi8 lli8 lli8 ----------------------------------- - - 1340 1 134C 135Fll m35d* l35c l lw"l 13ml l36olll 136C STRAP STRAP STRAP l3ao 1 138Cl! 139F lm,.ll390*1 139C* l4or 40E 1400* 14oc*l FROM STRAP STRAP STRAP SH 142 0* 1 142Cl! 143Fll 143Ell 1430 1 143Cl! l m l ml 1440111 l«c* 6684-25 STRAP STRAP STRAP BLOCK, BLOCKS 3 AND 4; 146o l 146C* l 1r* lm"l 1470 1 147C* l ar 1 148El! 148 0 1 146Cll STRAP STRAP STRAP ffi8 A ffi8 A ffi8 A ffibffib 30A ffib A ffi8 A ffibffib 38A ffi8 A TPA 549929 Fig. 18-601A Panel, 424A KTU, Station Connections via Cross-Connections for Basic Dial ntercom (Sheet 2) Page 19 BSP 518-215-418-i02_1971-11-19.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock.., "Co"' l o;.;ra;.;d" " ' o...;; O ;.; c.;.. t.;..15.;....;2;.;0..;; 1 " 2 - '1"'1"' 0:3 7 :3;;;

SECTON 518-215-418 ECT ACCORDNG TO TABLE TO POWER SUPPLY FO R 584-TYPE PANEL T R ' T TO TEL R(-K0) RG (1-XO) TTG (NOTE 3) B GRD 105Vt 66B4-25 BLOCK ROW ASSGNMENT COL A OR f' t NOTES AND 2 l [ffffj SET ( r-+- BAT. A GRD B BAT. NOTES'. TERM NATE CABLE TO COLU MN F F LEFT-HAND BLOCK OR CO LUMN A F RGHT -HAND BLOCK. REFER TO BLOCK DAGR AM COVERNG 66B4-25 BLOCK. 2. SEE F G. 7 for PANEL AND ECTNG BLOCK LAYOUT. A25B CABLE 11-Blj_ rr (BL- 11-0 0-11 "- 11-G G-l 11-BR BR-W 11-S fa S-11) R-B L (BL-R) R-0 O-R.!L R-G G-R,.t.g_ 17 R-B R (BR-R 'i"8 R-S S-R r-t-20 (BK-BL) BL-BK ru-c23 (BK-0) 124 0-BK BK-G 125 (G-BK) BK-BR BR-BK BK-5 S-BK) Y-BL) @: (BL-Y) Y-0 (o-y) Y-G G-Y) Y-BR m= BR-Y (Y-S) r.o & 1:47 r.t" 5-Y V-BL BL-V) v-o (0-V V-G (G-V) V-BR BR-V v-s s-v 3. ' 400J DODE (FURNSHED LOCALLY) OOJST BE ECTED BETWEEN THE TTG TERMNAL Of THE SELECTOR AND THE TTG TERMNAL Of THE 420A KTU N A "TOUCH-TONE" EQU PPED SELECTOR ONLY ARRANGEMENT. DODE SHOULD BE ECTED AS SHO/N BELOW: TO SELECTOR ----!-- TO 420A KTU * ASSOCATED WTH FRST NTERCOM CRCUT. (JACK ) ASSOCATED WTH SECOND N TERCOM CRCUT.(JACK 2 ASSOCATED WTH THRD NTERCOM CRCUT. (JACK 3 AlroiPHENOL 26 27 2 28 2 +---- 4 30 )-- 31 s 6 32 3 8 2._ 3 : 3S 10 36 2._ 12 38 13 39 14 4D S 41 16 42 17 43!! 19 4S 20 47 t= 46 21 2 22 48 f-- 23 f-- 49 f-- 24 f-- 50 f-- 25 f-- 698 APPARATUS MOUNTNG TABLE BLOCK ll 2t 3t 4 34C 34D 34C USNG 38C 380 38C 4078 KTU AS ASSGNED FOR STATON ECTONS, SEE FG. 17 48B 48C 48D 481! 20Bt USNG 881! 24Bt 424A AS ASSGNED FOR STATON KTU ECTONS, SEE FG. 18 488 48C 480 A 1 : t 12 f. 16 ----< 1 3 t! t 4 0 s 19 6 7 10 f 368_! 408t : ril7 r-< 18 8 0 19 8 7 14 2 9 4 12 5 6 10 13 16 18 3 17 S T R RG {1-0) R (1-0) TTG J ] T R RG (1-XO R 11-XO) TTG r-- 40A KTU '---- Fig. 19-601A Panel, 420A KTU, Long Line Circuit, Basic Dial ntercom, Connections to Optional KTU Mounted in 698 Apparatus Mounting Page 20 SP 518-215-418-i02 1971-11-20.jpg Scanned by Frank Harrell, (Cowbo Frank) Castle Rock, Colorado Oct 15, 2012 11:30:55

SS 2, SECTON 518-215-418 TO SGNAL (NOTE 2) TO POWER SUPPLY FOR 584-TYPE PANEL OW AND COLUMN SS GNMENT for 6T BLOCK N 601A PANEl l * J tj!j C3 83 A3 C4 84 A4 cs 85 AS C1 87 A7 C8 88 AS C6 86 A6 Cll 811 All KEY [ S B GRD [1 6684-25 BLK ECT LE ADS WTH ROW ASGN COL A OR FOR DESRED STATON f (NOTES 4 AND 5),258 CODE (NOTE ) NOTES:, SfLECT CODE AND ECT LEADS for SELECTED CODE AS SHON N VERT CAL COLUMN. 2. PROVD E SEPARATE SGNAL KEY FOR EACH STATON CODE TO BE SELECTED. 3. PROVD E A SEPARATE 421A KTU for EACH STATON CODE TO BE SELECTED. 4. TERMN ATE CABLE TO COL f f left-hand BLOCK OR COL UMH A f RGHT-HAND BLOCK. REfER TO BLOCK OJ AGRA M COVERNG 6684 25 BLOCK, 5. SEE F G. 6 for PANEL AND BLOCK LAYOUT. 6. F "TO UCH-TONE" S PROV OED ECT CG LEAD FROM 603A PANEL TO TERM. 29 N PLACE or B GRO. CG LEA D from EXT BLK TERM. 19 TO 66T BLK TERM. REMANS AS SHON. 1. WHEN MD RE THAN ONE 421 A KTU S USED for DSS, ECT 8 GRD OR THE CG LEAD AS follows: from 603A PANEL CG YS RH Y4 CG (NOT 7) B GRD B GRD B GRD B GRD B GRD 66-TYPE BLK 66-TYPE AS SOC WTH rt RST BLK OTHER 421A KTU 19 @ WTH "TOUCH TON( WTHOUT 10TOUCH TONE10 o---o--o---o C ABL( 2 3 4 5 6 7 8 9 0 '" (W BL) BL W w-o Yl r--r-l o-w Y2 {W-G n / G-W W-BR t-- BR-W (W-5) " rjo s-w R-BL 12 BL-R R-0 O-R R-G G-R) 16 R BR Pi BR R R-5 f- 2- S R BK-BL f-4 Bl BK BK-0 r#- O BK K-G G-BK BK-BR 28 BR BK NOTE 6 BK S (S-BK) Y-Bl '3,'-..#. BL Y Y-0 0-Y f-36 Y-G G-Y Y BR BR-Y r#-39 Y S S-Y V BL) 41 l4z" BL-V) r.3 o-v v-o r.s V G) fts- G V V BR,.g. f#- (BR V) v-s s-v 66-TYPE BLK 690 APPARATUS MOUNT NG UPPER AMPHENOL 26 E1 21 E 1 2 E1 28 9 30 5 31 6 32 1 33 8 34 9 35 10 36 37 12 38 13 39 14 40 15 4 1 16 42 17 t: A 14 ( 9 ( ( 13 2 18 4 19 45 "tt 10 20 46 ti- 21 47 22 48 23 49 24 SOA PANEL 50 25 43 ++- 12t- 16f--t- 8 f- t- 0 19 20 21 2 t: t- 23 t- t: t- 26 t- 27 28 29 30 31 32 421A KTU - (NOTE 3) - 37-39 - 33 E 34 38 1 5 6 18 3 17 f--t- S * ASSOCATED WTH first NTERCOM CRCUT ASSOCATED WTH SECOND NTERCOM CRCUT ASSOCATED WTH THRD NTERCOH CRCUT SELECT SPARE TERMNALS ON 6684 25 BLOCK TO MULTPLE GROUNDS. Fig. 20--601A Panel, 421A KTU, Arranged far DSS, Basic Dial ntercom, Connedians to Optional KTU Mounted in 690 Apparatus Mounting Page 21 BSP 518-215-418-i02 1971-11-2l.j g Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:31:15

SECTON 518-215-418 DAL COO FOR STA A A MATRX BLOCK (NOTE 3) NOTES: 1. USE 446f DODE (PROCURE LOCALLY) z. \/HEN RNGERS ARE USED AS AUDBLE SGNALS, REMOVE RNGER CAPACTORS from CRCUTS. Fig. 21-601A Panel, Basic Dial ntercom, Connections to Optional Dial Selected Preset Conference Circuit Using 1A1 Matrix Block Page 22 SP 518-215-418-i02 1971-11-22.j g Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:32:03

SS 2, SECTON 518-215-418 66B4-25 BLK BLKS AND 3 LEFT HAND BLK A25B CABLE RG --:-.-:- (11-BL) Rl --!:-r-b- BL-\1 LG \1-0 Ll RG ++ o-w 11-G R2 LG T-7- G-l L2 -r-rr- \1-BR RG "Bra BR-11 R3 g---rg-w-s s-wl LG lorto L3 rrr- (R-BL) RG --Tt'tr BL-R R4 -TJf--tt R-0 LG 'T O-R) L4 ""ts's R-G RG tr-rs G-R R5 -t71-it" R-BR LG r,s-r,s- BR-R L5 -t+-tg- R-S RG f-7'---r.;t- To-To- S-R BK-BL R6 r z-r z- BL-BK BK-0 L6 f-24cft- 0-BK RG BK-G R7 TsTs fi'tfs-" G-BK i.l "27'27 BK-BR L RG 7 "282s BR-BK "2929 BK-S R8 To S-BK Y-BL ftlil BL-Y f-3232 Y-O f-33-t-- 0-Y T. Y-G ---.!4----'35 i5 G-Y r-jti6 Y-BR f-37-t-- BR-Y Y-S f-3939 LO '"fo-to- S-Y T V-BL f-:4'1i"j- BL-V LG '43 TJ V-0 o-v '"«""«"" -, t-4545 TTG it- G-V SPARE V-BR SPARE 4747 BR-V SPARE SPARE :! :: 49 v-s s-v 1 -=--=- so 5o srs ---.!4----f-ff"f% TaTe- NOTE' AMPHENOL S P,P3 P2 SOA PANEL 26?o- 7?:;= 6 -+<; 27 2 8 -«28 3 29?+- 4 30 ("+--?+- s >+- 31?+- 6 >+- -+-< 3 D 32 >+- 3 8: i : 0 z. : 4. 34. 9 35 >-+- 35 0 -+< 10 z ;: 37 12 38 13 39 14 )-+- 40?-+- 15 )+- 41 16?-+- >+- 42 )-+- 17 )...;- 4 )...;- 18 )...;- 44 19 20 )...;- 45 )-+- 47 s= 22?-+- 48?-+- 23?-+- 49?-+- 24 )-+- 50 25..; -, 0 -, 0 ::1 0.. z z 0 u. ao 0.. 3 -+< 36 -+< -+< 37 -+< 12 -+< 38 -+< 13 39 f-+<;14 40! 16 f-+';42 f-+';11 k 43 18 44 19 45! s 48 23 49 ; 25 W N BL LEAD S USED TO PROVDE BUSY TONE, ECT 400J DODE N EACH BL LEAD AS REQURED. POLE LOCALLY PROCURED DODE AS SHOWN. A25B / CABLE W-BL) BL-W w-o o-w W-G G-W 11-BR) BR-11 w-s (S-W) R-BL BL-R) R-0 O-R R-G G-R R-BR BR-R R-S S-R BK-BL BL-BK BK-0 0-BK BK-G G-BK BK-BR BR-BK BK-S S-BK Y-BL BL-Y Y-0 0-Y Y-G G-Y Y-BR BR-Y Y-S S-Y V-BL BL-V v-o (0-V V-G. G-V V-BR BR-V v-s -v 6684-25 BLK BLK 2 RGHT HAND BLK RG 22 RX LG 33 44 LX 55 RG s--r RX2 7--f- LG 68 LX2 RG ::t: 10 10 RX3 LG LX3 --tt"t2 RG RX4 f-li-f-4.-, )2_ LG RG LX4 c-u-c!l RX5 LG LX5 RG ttt RX6 LG 23 LX6 24 Ts RG RX7 'tt 26 LG '27rz7 LX7 '28 f-29 RG RX8 30 LG '31f-31 LX8 f-jz'tr f33'33 RG RX9 f34'3t LG f)sr)s LX9 "36'36 RG '37'37 RXO '38'38 LG 39'39 f40to- LXO 8L BL2 rtlrtl '42'42 ff rtt-ffr" BL3 BL4 BL5 '45'45 BL6 BL7 rt1147 BL8 '48148 BL9 '49149 BLO t t TO TEL SET (SE E NOTE) Fig. 22-602A Panel, Connection of A25B Connector Cables to 6684-25 Connecting Blocks Page 23 BSP 518-215-418-i02_1971-11-23.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:32:28

SECTON 518-215-418 OPT ONS J r- r!- M r- R rx- z s T r H r- v N 66T BLOCK ON 602A PANEL (11-BL ) T T Lf NTERRUPTER 603A -o 0 0 CONTACTS AT 3 9 1341 LG!...- -o 0 0 PANEL (BL-11) @ OPTON R (11-0) Yl (O-l) (-G) (G-l) (11-BR) (BR-11) (11-S ) Y2 Y3 Y4 TTG (5-W) A BAT. (R-BL) (BL-R) CG RS NSULATE AND STORE SPARE LEADS SNGLE AC BUZZER OR BELL TYPE Of AUDBLE SPURT S t;nal L DC BUZZER OR BELL!RNGER NTERRUPTED RNGNG WTH STATON BUSY TONE NTERRUPTED RNGNG \ THOUT "TOUCHTONE' OPT ON AUDBLE RNGBACK TONE DAL TONE (NOTE 2) 407B KTU USED FLASHNQ USNG 407B KTU LNE LAMPS US NG 424A KTU NOT \ TH "TOUCHTONE' STRAPS factory furn SHED FACTORY FURNSHED NOTES., F {!)AND @ OPT ONS ARE PROV DED, A 400J DODE (PROCURED LOCALLY ) NUST BE PLACED BETWEEN TERMNALS B4,C4 AND RH LEAD MOVED from TERM. AS TO TERM. B8. 2. DAL TONE PROVDED BY PLUGGNG N 423A KTU. 3. USE 20 GAUGE STRAPPNG \lire (STRP \lire BEfORE TERMNAT NG ON ECT NG BLOCK ) for POWER ECTONS TO AVOD SHORTS. MAKE ECTONS ON 602A PANEL ECTNG BLOCK BEfORE ECT NG TO THE PO\ER SUPPLY. 4. ECT TO B GRD AS SHOWN. S. REMOVE (f) OPTON F 424A KTU S USED. Yl 2 1 3 f-<> Y2 Y5 - ->-- Y3 - RH 5 4 f-o Y4 6 f-<> Y5 7 RH 8 -<> TTG 9 -<> A BAT lo g RS 12 13 14 f-o (NOTE ) r-<'!note 6) 1 r 0 0 @ BTl 6 J32 1 ST l @ RN TO NTERRUPTER r+.>-- LOCATED AT 0 584-TYPE PANEL 0 r @ 0 0 t o- (NOTE 7 l 105Vt 1@ r. o- @ 0 ()+ ">-<> f 0 r 0 u!note 5 r (f) t 0 r r*t NOrroX 55 @ t 18V.t RG ()Vt 0R 8Vt 105Vt -24V OV.t LG -24V A BAT. A GRD -24V B BAT. B GRD 6. REMOVE OPTON F TOUCH-TONE S USED. 7. ECT RN LEAD TO PANEL F NTERRUPTED SGNAL FOR NTERCOM S THE SAME AS PROVDED BY 584-TYPE PANEL NTERRUPTER. F DFFERENT NTERRUPTED SGNAL S REQURED FOR NTERCOM, ECT TO FG. 25. * TERMNALS ON 5848 (MD PANEL TERMNALS ON 584C (MD) PANEL TERMNALS ON 5840 PANEL. 1o* 1 411 h-i' 21* 1 391 hci (NOT 4 TO POWER SUPPLY for 584-TYPE PANEL (NOTE 3) Fig. 23-602A Panel, Connedion of Power and nterrupter Leads, Option Strapping, and TOUCH-TONE Page 24 SP 518215418i02 19711124.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:32:46

SS 2, SECTON 518-215-418 6684-25 BLK BLK (SEE NOTE ) <$A NOTE: ANY SELECTED DGT MAY BE MADE THE NTAL DGT OF THE TWO DGT DAL CODE. STRAP THE R LEAD OF OF THE SELECTED DGT TO THE TO LEAD. THE DGT SO ASSGNED CANNOT BE USED FOR A STATON CODE. TPA 542935 Fig. 24-602A Panel, 424A KTU Connection of Transfer Digit Lead Page 25 BSP 518 215 418 i02_1971 11 25.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:33:05

SECTON 518-215-418 66B4-25 BLOCK ROll ASSGNMENT COL A OR r (NOTES AND 2) ROW AN D COLUMN ASSGN MENT ror 66T A25B B LOCK ON 602A P ANEL CABLE BL (11-BL) BO BR B3 Yl t--z BL-\1 rs- BR-\1 B7 Y5 BL X5 R-BL R-0 * BLiX6l """it * B4 Y2 14 O-R BL X2 15 R-G G-R * 16 * BL X3 t-"j8 * B6 Y4 L X4 (BR-R) R-S BL X 2Q S-R * BL X9 121 BK-BL * 122 BL-BK * Bl2 J3 BL(X8) (BK-0) BL X7 t-24 0-BK * J2 '25 BK-G Bll }-:';:;- G BK Bl3 LT2 BK-BR * TO BL XO rp.- Y-BL PO\ER B BAT. t---'v-sil SUPPLY... 66B4-25 BLOCK ROll ASSGNMENT COL A OR r TO rg TO PO\ER SUPPLY NOTES: B9 [ All 23 RN [ OVt 18Vt 105Vt B BAT. STRAP ---.-Q (NOTES 1,2 AND 3) '10' f-27-i _r--l:ttj-. TERMNATE CABLE TO COL r 1r LErT-HAND BLOCK OR COLUMN A lr RGHT-HAND BLOCK. RErER TO BLOCK DAGRAM COVERNG 6664-25 BLOCK. 2. SEE rig. 9 ror PANEL AND ECTNG BLOCK LAYOUT. 3. \/HEN ECTNG THE 421A KTU PER THE LAYOUT N rig. THE rirst 8 LEADS (11-BL THRU BR-11) Or THE A25B CABLE MUST BE NSULATED AND STORED AND THE REMANDER CUT DOliN N THE NORMAL MANNER. S-\1 A25B CABLE (S-11) G-R BK-BR V-BR 69D APPARATUS MOUNT lng UPPER AMPHENOL A 26 14 f--t-- 4 8 f--t-- 31 0 r- 721 33 E-----< 22 r- r- 925 35 26 r- 10 27 r- r- 11 29 37 r- 30 t= 12 31 r- r- 13 33 r- 1-41 34 1-49 17 1-9 f--t-- 5 1 r- 32 20 r- 823 r- 36 28 r- 38 3 t=r- 39 3 LDER AMPHENOL B E 5 1-823 39 E-----< 35 49 E-----< 7-422B KTU 421 A KTU * TO TEL SET, SEE rig. 27 ror ECTONS TPA 551245 Fig. 202A Panel, 4228 KTU, X1-XO Station Busy Seledor Circuit Connedions for Adding Tens Group and Optional 421A KTU to Provide nterrupted Signaling Page 26 SP 518-215-418-i02 1971-11-26.jpg Scanned by Frank Harrell, (Cowbo Frank) Castle Rock, Colorado Oct 15, 2012 11:33:24

SS 2, SECTON 518-215-418 '" 1\lll'l'>t.\0- ( ) (Z) (3) ( ) (5) (6) (7) (B) (9) (0) BLOO< ROW AND COLUMN ASSGMENT FOR STAT ONS r TO TEL S T la 41E 47E G;] G;] V A CROSS- STRAP* STRAP * S TO AUD SG VA CROSS - COMS 6664-25 ZE BE [i;] [q STRAP * STRAP * BLOCK, BLOCK, LEFT HAND BLOCK + A A A A A A A HB ffib ffie ffib ffib A ffib A A A A A A A A A A A A ffij ffie ffie ffie ffie Bill TO TEL SET V A CROSS- S ----------------------------------- GiJ G!!J 42r J SEE HOTEl NOTE: WHEN BL LEAD S USED TO PROV DE * USE CONTNUOUS METHOD OF' STR4PPNG. BUSY TONE, ECT 400J DODE N t BLOCK 2 S NOT REQU RE"O WHEN THE 4078 EACH BL LEAD AS REQU RED. POLE KTU S USED W THOUT STAT ON BUSY OPTON. LOCALLY PROCURED 0 ODE AS SHOWN, SE"E: FG, 8 F'OR P AN[l AND ECT NG BLOCK LAYOUT. 66B4 25 BLOCK, BLOCK 2t, RGHT HAND BLOCK + TO BL BL TEL SET TO BLK Fig. 26--602A Panel, 4078 KTU, Station Connections via Cross-Connections for Deluxe Dial ntercom Page 27 BSP 518-215-418-i02_1971-11-27.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock., Co"'l " o"' " ra;.;d" ' o...;; O ;.; c.;. t.;.15;;;..;2;.;0.;; 1 " 2 - '1"'1'-':3;;; 3 ;;; :..;. 4.;. 7

SECTON 518-215-418 STATON NUMBER () (2) (3) (4) (5 ) (6) (7) (8) BLOCK ROW AND COLUMN ASSGNMENTS for STATONS (9) (0) 0 [ f==8b 88 8ili @ 47E G;] TO TEL STRAP (SEE NOTE) STRAP (SEE NOTE SET V A CROSS- S ]" B 48E G;J HEET STRAP (SEE NOTE) TO AUD [ SG VA la CROSS- R S 2A 886A tfuj OA 8ili14A BiliffiBBllialli 22A 26A 30A Bllialli 38A TO TEL SET VA L 3A 7A A!SA CROSS- 4A SA 12A 16A S 8lli8ilitiili8ili 24A 28A 32A BlliBlli 40A TO AUD [ ] RG(B) S G V A RG(B) CROSS- R----------------------------------------------------------------------- S TO HEET T T G LG A[ ------------------------------------------------------------------------- ---- CROSS S J 6684 25 BLOCK 2 00 0 K, NOTE' USE CONTNUOUS METHOD Of STRAPPNG, DENOTES ECTONS TO BE MADE ON ECTNG BLOCK 3 DENOTES ECT! ONS TO BE MADE ON ECTNG BLOCK 4 (ASSOCATED WTH 69D APPARATUS MOUNTNG) SEE fig. 9 for PANEL AND ECT lng BLOCK LAYOUT Fig. 27--602A Panel, 424A KTU, Station Connections via Cross-Connections for Deluxe Dial ntercom (Sheet 1) Page 28 BSP 518215418i02 19711128.jpg Scanned by Frank Harrell, Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:34:05

SS 2, SECTON 518-215-418 STAT ON NUMBER (X ) (X2 ) (X3) (X4 ) (X5) (X6) (X7) (X8) (X9 ) (XO ) BLOCK ROJ ANO COLUMN ASS GNMENTS ror STATONS rrom SHEET [37rll [2Srl 0 Wl 6684-25 BLOCK, BLOCK 2t 00 rruti r;;;tl J 6684-25 c::..:..j BLOCK, BLOCK 4 t TPA 542938 Fig. 27-602A Panel, 424A KTU Station Connections via Cross-Connections for Deluxe Dial ntercom (Sheet 2) Page 29/30 BSP 518-215-418-i02_1971-11-29.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:34:26

SS 2, SECTON 518-215-418 6684-25 COHN 8LOCK ROll ASSGNMENT COL AORF (NOTES AND 2) A25B BL \K 1 CABLE ENOL 69B MOUNT NG APPARATUS BSTt==:==::=fijr-7"" (\1-aL) 49c 3E R J--±- BL - '!OC 4E AS ASSGNED FOR STAT ON ECTONS r...: (:._ _:: X.::_ R:...!. (SEE FG. 26 f--'r,_,g _,_,(...: TO TEL SET r: 4 = O:._) - ------t-7-sh:\1-gt::::t 28 _o:xoe.. rs G \1 l)c -jf"7 ;: l468ofl=====-ttg( NOTE3)-----gi O S - - \sr 2ij s : A 26 ',----------------.-< 14 "- 16 3 2... 2 <- 29 4 > 2_ Ofl 27) w-s. ;_. ' USNG 4078 KTU USNG 424A KTU ; USNG 4078 OR 424A KTU [ B t"fl R BL t; 3 :===+=========++=========== 31 o P,f : R 3: f+- O-R rft R G) 3 =:. 3! r--+< : BR R R S -r,;;;r,;- BL BK f25 BK-G tz6 G-BK BK-BR t25 BR-BK 1 4 tz9 BK-S <--+-- t=- s-k Y BL <--+--- BL-Y Y-0 l ---+-<' ' r,;-.-lbk BL L... ' ' Q-BK ::: <--+--- :-++--++H++-i-t+H-+--t+-+< 41 L...!: --fi-_,-ti---t-i--1-ti-t- GRD! t::=t=t+==+::t::t=++t=+ 105V t R rm- ; H =j-tt==t:::t===:t++= 1-T:Y,-,-S::T'--r+-< 19 t+-- SUPPLY FOR f o- =y <--+-- 5M TY. A_ B _ AT _ ----r,v BL- 46f-i f+-+-+---t-t------t-r-+<. :------- -t - t- ---- -r._ P.HEL A GRD t1t BL V 21 f-i--------t--e------r--+< OTES:. TERN NATE COliN CABLE TO COLUfotH r lr LEH HAND BLOCK OR COLUMN A RGHT-HAND BLOCK. REFER TO BLOCK DAGAN COVERNG &SM-25 BLOCK. 2. SEE rig. 12 ror PANEL AND CO ECTNG lllocl LAYOUT. J, A 400J DODE (rurnshed LOCALLY) MUST BE ECTED BETWEEN THE TTG TERN NAL or THE SELECTOR AND THE TTG TERN NAL OF THE 420A KTU N A "TOUCH-TONE' EQUPPED SELECTOR ONLY ARRANGEMENT. DODE SHOULD BE ECTED AS SHOWN BEL0 \1 : TO SELECTOR ---.t--- TO 420A KTU 9 L../ 15 L 2 19 0 ' Tii;v-:. R-.ior -t-k 3 5,.---.W : "-- 1 BK-0 f-') ;_-i-t-, B : 3 13 8 -+t-j-++h+t i- -f -1-t-t-ti-t-t--+< t 0 39 f-i--f,_rf+t-rf,_rfi-rfi-t--+< 8 40 7 15 ; f+. 14 2 9 4 12 5 6 10 B BAT. 1'43 V-0 47 ========t======= 44 o-v 22 Ts" -G: 48 r:46 G V 77 - F 781All!=.JR -Vf-' - = 23 f-r-- 49 f+- ' --t-+( 24 f+- 50 L 2 _s _f+- 19 13 16 18 3 17 S - 420A KTU Fig. 28-602A Panel, 420A KTU, Lang Line Circuit, Deluxe Dial ntercom, Connections to Optional KTU in 698 Apparatus Mounting Page 31 SP 518-215-418-i02 1971-11-31.jpg Scanned by Frank Harrell, (Cowboy Frank Castle Rock, Colorado Oct 15, 2012 11:35:00

SECTON 518-215-418 ECT LEAOS WTH e FOR OESREO STATON COOE (NOTE ) ROW ANO COLUMN ASSGNMENT FOR z 3 4 5 6 7 8 9 0 X XZ X3 X4 X5 X6 X7 XS X9 xo 66T BLOCK ON 60ZA PANEL 83 Yl 84 YZ 85 Y3 (NOTE 7) 814 87 Cl4 86 Y4 CG All 813 LTZ* s s TO SGNAL [ KEY (NOTE Zl 8 GRO -r B GRO 0 B GRO :::[ B GRO B GRO B GRO NEL B B A==-------------------------------------------------------------------------- B B A Ṯ Y5 RH NOTES:. SELECT COOE ANO ECT LEAOS FOR SELECTEO COOE AS SHOWN N VERTCAL COLUN. 2. PROV OE SEPARATE SGNAL KEY FOR EACH STAT ON COOE TO BE SELECTEO. 3. PROV OE SEPARATE 421A KTU FOR EACH STAT ON COOE TO BE SELECTEO. 4. SEE FG. 10 FOR PANEL ANO!CT NG BLOCK LAYOUT 5. WHEN MORE THAN ONE 421A KTU S USEO FOR OSS ECT B GROUNO OR THE CG LEAO FROM 603A PANEL AS FOLLOWS : 66-TYPE BLK 66-TYPE 66-TYPE BLK 602A AS SOC WTH Fl RST BLK-OTHER AS SOC WTH LAST. PANEL 421A KTU 421 A KTUS 421A KTU @ - WTH "TOUCH-TONE " - WTHOUT "TOUCH-TONE" 6. A 400J OOOE (PROCURE LOCALLY) MUST BE ECTEO AS SHOWN N A 0 AL-TONE EQU PPEO SELECTOR-ONLY ARRANGEENT ON 66T ECT NG BLOCK. MOVE RH LEAO FRO TERNAL A8 TO TERNAL B8. (SEE NOTE, FG. 23.) Fig. 29--602A Panel, 421A KTU, Arranged for DSS, Deluxe Dial ntercom, Connections to Optional KTU Mounted n 69D Apparatus Mounting {Sheet 1) Page 32 BSP 518-215A18-i02_1971-11-32.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:35:21

SS 2, SECTON 518-215-418 Yl Y2 Y3 Y5 RH Y4 CG (NOTE 5) LT2* s 8 GRO B GRO 8 GRO 8 GRO (NOTE 51 8 GRO B BAT 6684-25 CCJ\N BLOCK LEFT-HAND BLOCK (NOTE 4) [ffffgj A25B CABLE w-bu r--j"" lbl- r-z r--s- 0 o-w --...\+: W-G G-W.. r-t- rg- rto rtl r-rr r--;-3 t-14 r,s 1--j"g t-2o 23 z. -zt 26 27 128 rzg r-jo r-v i2 43 -«4s r.-s -r.7 '48 '49 BR r-e le_r ::..S. s-w R-BL BL-R R-0 (O-R ) R-G G-R R-BR BR-R R-5 5-R BK-Bl BL-BK BK-0 0-BK BK-G G-BK BK-BR (BR-BK ) BK-5 5-BK Y-BL Bl-Y) Y-O 0-Y '34 Y-G G-Y t-36 Y-BR tj7 BR-Y t-36 Y-S t-39 5-Y tic V-BL 41 Bl-V v-o o-v V-G G-V V-BR BR-V v-s s-v 690 APPARATUS MOUNT NG UPPER AMPHENOL A _/ 26 14 ( ( 9 "5 27 ( 12 f- t- 2 13 28 16f-r- 3 ;- 29 0+-- 4 8 30 E+- 5 f-t- 31 0 6 19 32 20 1 21 33 22 t-t- 8 23 f-r- 34 24 9 t- E t- _; 35 _; 10 27 _; t- 36 28 29 30 421 A _; 12 31 KTU _; 38 32 (NOTE 3) 33 _; 37 ; 13 ; 39 35. ;= r- _; 14 36 r- ; 40 37 t: r- :; 15 39 r- 41 34 16 38 42 1 _; 17 2 43 _; 18 :5 ;: 4- _; 45 10 _; 20 f+- ; 46 21 E-+-- _; 47 5 22 6 48 18 _; 23 3 49 17 f-r- _; 24 15./so _; 25 f-'- 4 Fig. 29-602A Panel 421A KTU, Arranged far DSS, Deluxe Dial ntercom, Connedlons to Optional KTU Mounted in 69D Apparatus Mounting (Sheet 2) Page 33 SP 518-215-418-i02 1971-11-33.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:35:41

SECTON 518-215-418 6684 2S BLK, BLK 3 LEFT-HAND BLK (NOTES AND 2) P/0 6 A2SB 9 D APPARATUS OUNT NG j UPPER 1 _ CABLE AMPHENOL 0 4258 KTU [ L ().- -- - ( BL) t=a ELECTED L 2 BL \1 26 ==== 14 - TAT ON L 1 fl.- \1-0 912 L- - - T L :: D -;::::= L J L w 2 t;h====!j==t=ti!: SSOC ATED [ - t:l = R 3 29 ;, \lith DAL - r::z= r----ib"'r0:.::i 11cT--+-t-<...,...- :: = NTERCOM AT _. _/...---====-r!- 4 8 f.- ELECTED V f-.>- li -S 30 f:-r TAT ON STRAP L.,_l.Q...!:L S 1-- f.l.!.. BL R 31 f+-1-1---1-+.( 0 L (3) f.r (R-0) 6 9 TO 42S8 KTU 1 "L " LEAD Or ri-----ji-1-j--ill = 2 f-+1---1-+-+< := CODE ASSGNED --H-f_:=t:;==..,r=iii5}---.,--+---<-<. - ++-" -i1 5 6 G R, 8 E 33 Hl---1-+-+< 2 23 2 - ;..--..-- ;- TO PRESET L :;: 34 >----+-+-+-+-< 24 CONrERENCE R- S 9 2 5 S R 3S H-1-+-+--+< 26 BK BL 10 H>-----1--1--+-+-< 27 (BL-BK ) 36 H-1--+-+--+< 28 BK-O H>-----1--1--+-+-< 29 q} 0-BK ; 30 BK G Hr---+--1--+-+-< lli: 38 f-+---1-1-1--+-( L (3),_g _ R 13 H-+-+-4--+.(. 33 ROW AND COLUMN ASSGNMENT FOR 66T ECTNG BLOCK ON 602A PANEL 812 r----+-_.j f.ll_ BR BK 39 f-+ -J - f--1-- t-< 3!-- - (BK S l4 f-+-j- f--1-- t-< 36!-- "* (S BK) f-+-j --'f--1--t-< : Y-BL ) 41 tft f+---if--1--1-+< 34,_g. y 16 38..n_ 0-Y 42 7.li_ Y G 17 :-+--- G Y 43 2,._ Y-BR 18 :-+- fll BR Y 4 f.# Y S 1 9 -;:---- s-y 4S H) :--+-+--+< 82: V BL 20 tfr BL V ; H >- - - - 1-+-+ < 81: = 47 f.-ii. V-G 22 f--t---1--t-< G V 48 f..<----+-+< TO POWER [B BAT V BR 23 f--<----4--+< :PLY -"R--'G=--+-------1 (BR V : H---.._-'-< 584-TYPE B GRD - SO f+- PANEL " v 2S f-'-- NOTES', TERMNATE CABLE TO COLUMN r lr LErT HAND BLOCK OR COLUN A 1r RGHT-HAND BLOCK. RErER TO BLOCK DAGRA COVERNG 66B4 2S BLOCK. 2. SEE FG. FOR PANEL AND ECTNG BLOCK LAYOUT. 3. PROV DE THE 413A KTU ONLY \/HEN ACCESS TO THE PRESET CONrERENCE S BY DAL CODE OR BY DAL CODE AND DSS. DO NOT PROVDE THE 413A KTU \/HEN ACCESS TO THE PRESET CONfERENCE S LMTED TO DSS. 10 5 6 18 3 17 f-- ls 421A KTU (NOTES 4 AND S) ]TO (NOTE 3) SH 2 4. \/HEN THS CRCUT S PROVDED,RNG VOLTAGE (OSVt) MUST BE USED TO OPERATE -THE AUDBLE SGNALS ECTED TO THE 01 AL NTERCOM LNE, S, "" OPT ON MUST BE PROV OED ON THE 421 A KTU. ON 421A KTU OPTON BLOCK, STRAP TERMNALS AS FOLLOWS : TO 2, 5 TO 6, 7 TO 8. 6, THE "CA" LEAD UST ECT TO THE 0 OOE MATRX \HETHER OR.NOT THE 413A KTU S PROV DEO. 7. WHEN RNGERS ARE USED AS AUDBLE SGNALS, REMOVE RNGER CAPACTORS FROM CRCUT. - - Fig. 30-602A Panel, Deluxe Dial ntercom, Connections to Optional Preset Conference Circuit (421A KTll, Mounted in 69D Apparatus Mounting, 413A KTU Mounted in 69B Apparatus Mounting and a 1A 1 Matrix Block) (Sheet 1) BSP 518-215-418-i02_1971-11-34.jpg Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct 15, 2012 11:35:59

SS 2, SECTON 518-215-418 c ft L rro lit ht ht hs tt6 h"4 6684-2 5 BLOCK, (NOTES BLOCK 4, AND 2) RGHT HAND BLOCK A2 5B A B D E F o---<>-<>---<>- CABLE RG (W-BL) FROM r SHEET! NOTE 3) ry BL-W B GRD,--r-r- w- 4 0-'!1_.. W-G + G- '.1-BR BR-'91 w-s l"g s-w rrrrra tt9 t:::: i2o R-BL) BL-R_l R-0 0-R R-G G-R R-BR BR-R R-S S-R LOWER P/0 69D APPARATUS MOUNTNG AMPHENOL B 26.J 4 12 413A.J 7 13 KTU _..; 8 16 15 29 4 8 30 3 ; ; 0 6 4 2 t: 19 5 33 6 7 34 9 35 _f::: 10 8 lll 2 ljlr- TO SELECTED "R" LEAD OF CODE ASSGNED TO PRESET CONFERENCE (NOTE 6) R (RC) CA R J- (RC) CA A TO SELECTED MATRX AUDBLE --- (RC) CA BLOCK SGNAL Fig. 30-602A Panel, Deluxe Dial ntercom, Connections to Optional Preset Confernce Circuit (421A KTU, Mounted in 69D Apparatus Mounting, 413A KTU Mounted in 698 Apparatus Mounting and a 1A1 Matrix Block) (Sheet 2) Page 35 SP 518-215-418-i02 1971-11-35.jpg Scanned by Frank Harrell, (Cowbo Frank) Castle Rock, Colorado Oct 15, 2012 11:36:18