LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Similar documents
LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2P05. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

AS09..S 3-pole Contactors - Spring Terminals

A V 50Hz / V 60Hz

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Datasheet - SRB301LC 24VAC/DC

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Type: DILM25 10(24V50HZ) Article No.:

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Type: DILM12 10(24VDC) Article No.:

Ordering details. Approval. Classification

Series CT7N Bimetallic Overload Relays

Datasheet - SRB-E-201ST

Minicontactorrelay,2NO/2NC,DCoperated

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Safety dialogue solutions

Magnecraft Power Relays

02/11/2015

16 A and 25 A power contactors with or without handle

Bulletin 190 IEC Modular Starter System

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

AC1036. Definite Purpose Contactors

Modular pulse operated latching relay 16 A

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Circuit-Breakers for Motor Protection Series 8523/8

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Data Sheet Definite Purpose Contactors Ex9CK Series

High performance circuit breakers

Pluggable interface relays CR-M Miniature relays

DMX and 4000 air circuit breakers from 800 to 4000 A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Photoelectrics Through-beam Type PA18C.T..., DC

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Interface Relays and Optocouplers Product group picture

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control


Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Magnetic and Hydraulic-Magnetic Circuit Breaker

OT 100/ /700 P5

llen-bradley 194R-HM4-NFPA3

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

LED Driver Compact fixed output

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Generator protection relay

LED control gear Compact fixed output

TeSys circuit-breakers

Kuhnke Technical Data. Contact Details

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

Data Pattern Generator

Manual Motor Starter Specifcations

Bulletin 150, 154 Softstarters Quick Selection Table

LED Driver Compact fixed output

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Selection guide siemens.com/sirius-modular-system

Transcription:

Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Power pole contact composition [Ue] rated operational voltage [Ie] rated operational current Motor power kw Control circuit type [Uc] control circuit voltage Auxiliary contact composition Oct 17, 2018 TeSys TeSys D Star delta starter LC3D Motor control AC-3 Pre-wired 3 x 3P 3 x 3 NO <= 690 V AC 25...400 Hz for power circuit 115 A (<= 60 C) AC AC-3 for power circuit at <= 440 V 110 kw at 380/400 V AC 50/60 Hz 110 kw at 415 V AC 50/60 Hz 110 kw at 440 V AC 50/60 Hz 63 kw at 220/230 V AC 50/60 Hz AC 50/60 Hz 220 V AC 50/60 Hz 1 NC for KM2 line contactor 1 NO for KM3 delta contactor [Uimp] rated impulse withstand voltage 8 kv conforming to IEC 60947 Overvoltage category [Ui] rated insulation voltage Electrical durability Mounting support III 600 V certifications CSA power circuit 600 V certifications UL power circuit 600 V certifications CSA signalling circuit 600 V certifications UL signalling circuit 1000 V conforming to IEC 60947-4-1 power circuit 1000 V conforming to IEC 60947-1 signalling circuit 0.95 Mcycles 115 A AC-3 <= 440 V Plate Standards EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14 Product certifications BV 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL Complementary Connections - terminals Tightening torque Mechanical durability Connector for power circuit 1 10...120 mm² flexible without cable end Connector for power circuit 2 10...50 mm² flexible without cable end Connector for power circuit 1 10...120 mm² flexible with cable end Connector for power circuit 2 10...50 mm² flexible with cable end Connector for power circuit 1 10...120 mm² solid without cable end Connector for power circuit 2 10...50 mm² solid without cable end Connector for control circuit 1 1...2.5 mm² flexible without cable end Connector for control circuit 2 1...2.5 mm² flexible without cable end Connector for control circuit 1 1...2.5 mm² flexible with cable end Connector for control circuit 2 1...2.5 mm² flexible with cable end Connector for control circuit 1 1...2.5 mm² solid without cable end Connector for control circuit 2 1...2.5 mm² solid without cable end 12 N.m for power circuit connector flat Ø 6...8 mm 1.2 N.m for control circuit connector flat Ø 6 mm 1.2 N.m for control circuit connector Philips No 2 8 Mcycles Operating rate 30 cyc/h at <= 60 C Starting time Coil technology Control circuit voltage limits Inrush power in VA Hold-in power consumption in VA Heat dissipation Auxiliary contacts type Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Width Height Depth Product weight 30 s Without built-in suppressor module 0.3...0.5 Uc at 55 C drop-out 50/60 Hz 0.8...1.15 Uc at 55 C operational 50/60 Hz 280...350 VA at 20 C 0.8 60 Hz 280...350 VA at 20 C 0.8 50 Hz 2...18 VA at 20 C 0.3 60 Hz 2...18 VA at 20 C 0.3 50 Hz 3...8 W at 50/60 Hz Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC Mirror contact conforming to IEC 60947-4-1 3 x 1 NC 25...400 Hz For signalling circuit 17 V for signalling circuit 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact 450 mm 555 mm 205 mm 11.8 kg Environment Insulation resistance 2 > 10 MOhm for signalling circuit IP degree of protection IP2x front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for storage -60...80 C Ambient air temperature for operation Operating altitude -40...70 C at Uc 3000 m without derating in temperature Fire resistance 850 C conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor closed 15 Gn for 11 ms

Shocks contactor open 6 Gn for 11 ms Contractual warranty Warranty period 18 months 3

Dimensions Drawings Dimensions LC3 or 3 x LC1 a b c G H LC3 D115 or 3 x LC1 D with components 450 555 205 425 525 LC3 D150 or 3 x LC1 D with components 450 555 205 425 525 4

Connections and Schema Wiring (1) Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). (2) Remote control. 5