Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

Similar documents
Level Measurement Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement RF Capacitance switches

Level Measurement Continuous level measurement - Capacitance transmitters

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F M. Transmitter MAG 5000/6000 4/33

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

2291 Guided Wave Radar Level Transmitter

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pendant Light Fitting IEC Series 6470/2

Capacitance Level Measurement Electronic insert FEC 12

OPTIFLEX 2200 C/F Technical Datasheet

Pressure transmitter For applications in hazardous areas Model IS-3

TFRN Industrial RTD temperature sensor. CombiTemp TM

PROPORTIONAL VALVES Sentronic plus

Model JDF Field Indicator

Guided Radar (TDR) Level Transmitter for storage and process applications

Explosion Proof Audible Signal db(a) Series YA60

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

TFRN Industrial RTD temperature sensor. CombiTemp TM

Centurion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series.

Mechanical flow switch for On/Off control

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Guided Wave Radar Level Meter

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Process transmitter RMA422

Rosemount 1151 Smart Pressure Transmitter

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

General Specifications

Process Transmitter RMA 422

Inductive sensor NI3-EG08K-Y1-H1341

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

EXLUX ECOLUX C-LUX 6480 Series

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

RMA42. Technical Information

DMP 331i / DMP 333i LMP 331 i

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Technical Information Gamma Modulator FHG65 Synchronizer FHG66

Parts List _2.1. Flygt /.890

Inductive sensor BI1.5-EG08K-Y1

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

EXLUX ECOLUX 6480 Series

Pendant Light Fittings Series 6050

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

PMG. Vibration Energy Harvesters

Liquid Level Sensor Type AKS 4100U

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Parts List _2.1. Flygt /.190

Explosion Proof Audible Signal db(a) Series YA60

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

Signal conditioning instruments

Liquid Level Sensor AKS 4100U

2.9 Sigma/ 2 Plunger Metering Pumps

Single Point Flow Monitor SW118 SW119

Modular Lube Lubrication Systems System Controls

Liquid Level Sensor Type AKS 4100/4100U

Inductive sensor NI10-M18-Y1X-H1141

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Revision 1.0 Parts List Minor

Revision 1.0 Parts List Salvador 1~, 3~

Operating instructions

GRUNDFOS alldos product information. The solution for complex dosing tasks

EXPlora. Introduction

Revision 2.0 Parts List Minor

MSP422 Analogue Liquid Level Transmitter Software version 1.2A and onwards

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

TFR5 Room or outdoor temperature sensor. CombiTemp TM

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

Inductive sensor With analog output BI15-M30-LI-EXI

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

General Specifications

Technical Information RIA45

Revision 3.0 Parts List Salvador 1~, 3~

Selection table SITOP power supplies

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Transcription:

Overview Configuration Installation 19 beam width: 1. horn = 19 2 horn = 1 3 horn = 10 4 horn = 8 Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with the horn antenna. There is a signal transmitted outside of the beam angle; therefore false targets may be detected is a 2-wire, 2 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support 2 GHz high frequency allows for small horn antennas for easy mounting in nozzles Insensitive to mounting location and obstructions, and less sensitive to nozzle interference Short blanking distance for improved minimum measuring range to 0 mm (2") from the end of the horn Communication using HART or PROFIBUS PA, or FOUNDATION Fieldbus TM Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson AMS, or Field Device Tools, such as PACTware or Fieldcare via SITRANS DTM. Mounting unit on bypass Mounting unit on vessel Orient front or back of device toward vent. Use largest horn size possible in pipe. Mounting unit on stilling well Orient front or back of device toward stillpipe slots. Use largest horn size possible in pipe. Application includes a graphical local user interface (LUI) that improves setup and operation by including an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation. The 2 GHz frequency creates a narrow, focused beam allowing for smaller horn options and decreasing sensitivity to obstructions. s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. measures superbly on low dielectric media, and in small vessels, as well as tall and narrow vessels. Key Applications: liquid bulk storage tanks, process vessels with agitators, vaporous liquids, high temperatures, low dielectric media Mounting on a nozzle minimum 10 mm (0.4 ) installation /224 Siemens FI 01 2010

Technical specifications Mode of operation Measuring principle Radar level measurement Frequency K-band (2.0 GHz) Minimum measuring range 0 mm (2") from end of horn Maximum measuring range 20 m (6 ft), horn dependent Output HART : Version.1 - Analog output 4 to 20 ma - Accuracy ± 0.02 ma - Fail-safe Programmable as high low or hold (loss of echo) NE 43 programmable PROFIBUS PA: Profile 3.1 - Function blocks 2 Analog Input (AI) FOUNDATION Fieldbus TM H1 - Functionality Basic or LAS -Version ITK.2.0 - Function blocks 2 Analog Input (AI) Performance (according to reference conditions IEC60770-1) Maximum measured error mm (0.2") Influence of ambient temperature <0.003 %/K Rated operating conditions Installation conditions Location Indoor/outdoor Ambient conditions (enclosure) Ambient temperature -40 to +80 C (-40 to +176 F) Installation category I Pollution degree 4 Medium conditions Dielectric constant r r > 1.6, horn and application dependent Process temperature -40 to +200 C (-40 to +392 F) (at process connection with FKM o-ring) -20 to +200 C (-4 to +392 F) (at process connection with FFKM o-ring) Process pressure Up to 40 bar g (80 psi g), process connection and temperature dependent. See Pressure/Temperature curves for more information Design Enclosure - Material Aluminium, polyester powdercoated - Cable inlet 2 x M20x1. or 2 x ½" NPT Degree of protection Type 4X/NEMA 4X, Type 6/ NEMA 6, IP67, IP68 Weight < 3 kg (6.6 lbs) 3.7 mm (1½") threaded connection with 1½" horn antenna Display (local) Graphic local user interface including quick start wizard and echo profile display Antenna - Material 316L stainless steel [optional alloy N06022/2.4602 (Hastelloy C-22 or equivalent)] - Dimensions (nominal horn sizes) Standard 1." (40 mm), 2" (48 mm), 3" (7 mm), 4" (9 mm) horn and optional 100 mm (4") horn extension Process connections Process connection 1½" or 2" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" or 2" [(BSPT), EN 10226] G 1½" or 2" [(BSPP), EN ISO 228-1] Flange connection 2", 3", 4" (ANSI 10, 300 lbs), 0, 80, 100 mm (PN 16, 40, JIS 10K) Power supply 4 to 20 ma/hart Nominal 24 V DC (max. 30 V DC) with max. 0 PROFIBUS PA 1 ma per IEC 6118-2 FOUNDATION Fieldbus 20.0 ma per IEC 6118-2 Certificates and approvals General CSA US/C, CE, FM, NE 21, C-TICK Radio FCC, Industry Canada and Europe ETSI EN 302-372, C-TICK Hazardous - Intrinsically Safe (Europe) ATEX II 1G Ex ia IIC T4 ATEX II 1D Ex td A20 IP67 T90 C - Non-sparking/Energy Limited ATEX II 3G Ex na/nl IIC T4 Gc (Europe) - Intrinsically Safe (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T4 - Non-incendive (Canada/USA) CSA/FM Class I, Div. 2, Groups A, B, C, D T - Intrinsically Safe (International) IECEx Ex ia IIC T4, Ex td A20 IP67 T90 C - Flame Proof (International/ Europe) - Increased Safety (International/ Europe) IECEx/ATEX II 1/2 GD, 1D, 2D, Ex dmbia IIC T4 Ga/Gb, Ex td A20 IP67 T90 C IECEx/ATEX II 1/2 GD, 1D, 2D, Ex embia IIC T4 Ga/Gb, Ex td A20 IP67 T90 C - Explosion Proof (Canada/USA) CSA/FM Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III T4 Marine Lloyd s Register of Shipping ABS Type Approval Bureau Veritas Programming Intrinsically Safe Siemens handheld Infrared receiver programmer - Approvals for handheld programmer IS model: ATEX II 1 GD Ex ia IIC T4 Ga Ex ia D 20 T13 C Ta = -20 to +0 C CSA/FM Class I, II, III, Div. 1., Groups A, B, C, D, E, F, G, T6 Ta = +0 C IECEx SIR 09.0073 Siemens FI 01 2010 /22

Handheld communicator HART communicator 37/47 PC SIMATIC PDM Emerson AMS SITRANS DTM (for connection into FDT, such as PACTware or Fieldcare) Display (local) Graphic local user interface including quick start wizard and echo profile displays HART is a registered trademark of the Hart Communications Foundation. TM FOUNDATION Fieldbus is a trademark of Fieldbus Foundation. Hastelloy and C-22 are registered trademarks of Haynes International Inc. /226 Siemens FI 01 2010

Selection and Ordering data Order No. C) 7 M L 4 3 1-2-wire, 2 GHz pulse radar level transmitter for continuous 7777 0-777 7 monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Ideal for small vessels and low dielectric media. Process Connection and Antenna Material 316L (1.443 or 1.4404) stainless steel, 0 PTFE emitter, FKM seal 316L (1.443 or 1.4404) stainless steel, 1 PTFE emitter, FFKM seal Hastelloy C-22/2.4602, PTFE emitter, FKM seal 1) 2 Hastelloy C-22/2.4602, PTFE emitter, FFKM seal 1) 3 Process Connection Type 1½" NPT [(Taper), ANSI/ASME B1.20.1] 2) AA R 1½" [(BSPT), EN 10226] 2) AB G 1½" [(BSPP), EN ISO 228-1] (parallel thread) 2) AC 2" NPT [(Taper), ANSI/ASME B1.20.1] AD R 2" [(BSPT), EN 10226] AE G 2" [(BSPP), EN ISO 228-1] (parallel thread) AF 2" ASME, 10 lb, FF, ASME B16. 3) BA 3" ASME, 10 lb, FF, ASME B16. 3) BB 4" ASME, 10 lb, FF, ASME B16. 3) BC 2" ASME, 300 lb, FF, ASME B16. 3) CA 3" ASME, 300 lb, FF, ASME B16. 3) CB 4" ASME, 300 lb, FF, ASME B16. 3) CC DN 0 PN 16, Type A, EN 1092-1 3) DA DN 80 PN 16, Type A, EN 1092-1 3) DB DN 100 PN 16, Type A, EN 1092-1 3) DC DN 0 PN 40, Type A, EN 1092-1 3) EA DN 80 PN 40, Type A, EN 1092-1 3) EB DN 100 PN 40, Type A, EN 1092-1 3) EC JIS 0A 10K, FF, JIS B2220 3) FA JIS 80A 10K, FF, JIS B2220 3) FB JIS 100A 10K, FF, JIS B2220 3) FC DN 0 PN 10/16 DIN EN1092-1 form B1 GA DN 80 PN 10/16 DIN EN1092-1 form B1 GB DN 100 PN 10/16 DIN EN1092-1 form B1 GC DN 10 PN 10/16 DIN EN1092-1 form B1 GD DN 0 PN 2/40 DIN EN1092-1 form B1 HA DN 80 PN 2/40 DIN EN1092-1 form B1 HB DN 100 PN 2/40 DIN EN1092-1 form B1 HC DN 10 PN 2/40 DIN EN1092-1 form B1 HD Communication/Output PROFIBUS PA 1 4 to 20 ma, HART, startup at <3.6 ma 2 FOUNDATION Fieldbus TM 3 Enclosure/Cable inlet Aluminum, Epoxy painted 2 x ½" NPT 0 2 x M20x1. 1 Antenna 1½" horn 4) A 2" horn (fits 2" ASME or DN 0 nozzles) B 3" horn (fits 3" ASME or DN 80 nozzles) C 4" horn (fits 4" ASME or DN 100 nozzles) D 1½" horn with 100 mm extension 4) E 2" horn with 100 mm extension F 3" horn with 100 mm extension G 4" horn with 100 mm extension H (Note: Please use largest horn size possible.) Selection and Ordering data Order No. C) 7 M L 4 3 1-2-wire, 2 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage 7777 0-777 7 and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Ideal for small vessels and low dielectric media. Approvals General Purpose, CE, CSA, FM, FCC, R&TTE, A C-TICK Intrinsically Safe, CSA/FM Class I, II, III, Div. 1, B Groups A, B, C, D, E, F, G, FCC Intrinsically Safe, IECEx/ATEX II 1 GD Ex ia IIC T4, C Ex td A20 IP67 T90 C, R&TTE, C-TICK, INMETRO Non-incendive, CSA/FM Class I, Div. 2, Groups A, D B, C, D, FCC Non-sparking, Energy Limited, ATEX II 3G Ex na/nl E IIC T4, CE, R&TTE, C-TICK Increased Safety, IECEx/ATEX II 1/2 GD Ex embia F IIC T4, Ex td A20 IP67 T90 C, CE, R&TTE, C-TICK ) Flame Proof, IECEx/ATEX II 1/2 GD Ex dmbia IIC G T4, Ex td A20 IP67 T90 C, CE, R&TTE, C-TICK ) Explosion Proof CSA/FM Class I, II, III, Div. 1, Gr. A, H B, C, D, E, F, G, FCC ) Pressure rating Rating per Pressure/Temperature curves in manual 0 0. bar g (7.2 psi g) maximum 1 1) Not available with process connection options AA to AF 2) For 1½" horn antennas only, max. range 10 m (32.8 ft), dk > 3 3) Siemens Milltronics type flange, see instruction manual for details 4) For 1½" threaded connection only, max. range 10 m (32.8 ft), dk > 3 ) Applicable to Communication option 0 or 2 only C)Subject to export regulations AL: N, ECCN: EAR99 Further designs Order code Please add "-Z" to Order No. and specify Order code(s). 1) 2) 3) Plug M12 with mating Connector A0 7) 8) 4) Plug 7/8" with mating Connector A Stainless steel tag [69 x 0 mm (2.71 x 1.97")]: Measuring-point number/identification (max. 16 characters); Y1 specify in plain text Test certificate: Manufacturer's test certificate M to DIN C11 30, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 Namur NE43 compliant, device preset to failsafe N07 <3.6 ma ) Operating Instructions for HART/mA device English JE03 German JE33 Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English German Note: The Operating Instructions should be ordered as a separate line item on the order. QX82 JF03 JF33 Siemens FI 01 2010 /227

Further designs Please add "-Z" to Order No. and specify Order code(s). Multi-language Quick Start manual This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and Operating Instructions library. Operating Instructions for FOUNDATION Fieldbus device English German Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and Operating Instructions library. Accessories Handheld programmer, Intrinsically safe, EEx ia HART modem/rs-232 (for use with a PC and SIMATIC PDM) HART modem/usb (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1., rated -40 to +80 C (-40 to +176 F), HART ) One metallic cable gland M20x1., rated -40 to +80 C (-40 to +176 F), PROFIBUS PA 6) SITRANS RD100 Remote display - see RD100 on page /324 SITRANS RD200 Remote display - see RD200 on page /327 SITRANS RD00 Remote display - see RD00 on page /331 Order code XE82 KL01 KL31 XN81 C) 7ML1930-1BK D) 7MF4997-1DA D) 7MF4997-1DB 7ML1930-1AP 7ML1930-1AQ 1) Available with Enclosure option 1 only 2) To be used with Communication options 1 and 3 only. Connector has IP67 rating. 3) Available with Approvals option A, B, or C only 4) Available with Enclosure option 0 only ) Product shipped with plastic cable gland, rated to -20 C. If -40 C rating required, then metallic cable gland is recommended. C) Subject to export regulations AL: N, ECCN: EAR99 D) Subject to export regulations AL: N, ECCN: EAR99H /228 Siemens FI 01 2010

Selection and ordering Data Spare parts Order No. Order No. C) AE0116848 Enclosures M20 cable inlet, approval option D, with M20 cable inlet, approval option F, with HART M20 cable inlet, approval option G, with HART NPT cable inlet, approval option H, with HART NPT cable inlet, approval option A, with FOUNDATION Fieldbus communication, M20 cable inlet, approval option A, with FOUNDATION Fieldbus communication, no process connection NPT cable inlet, approval option C, with FOUNDATION Fieldbus communication, no process connection M20 cable inlet, approval option C, with FOUNDATION Fieldbus communication, no process connection C) AE02448270 NPT cable inlet, approval option A, with HART M20 cable inlet, approval option A, with HART NPT cable inlet, approval option B, with HART M20 cable inlet, approval option B, with HART NPT cable inlet, approval option C, with HART M20 cable inlet, approval option C, with HART NPT cable inlet, approval option D, with HART M20 cable inlet, approval option D, with HART NPT cable inlet, approval option A, with M20 cable inlet, approval option A, with NPT cable inlet, approval option B, with M20 cable inlet, approval option B, with NPT cable inlet, approval option C, with M20 cable inlet, approval option C, with NPT cable inlet, approval option D, with C) AE0116819 C) AE02448274 C) AE0116820 C) AE02448278 C) AE0116823 C) AE0116824 C) AE0116827 C) AE0116832 C) AE0116834 C) AE011683 C) AE0116836 C) AE0116838 C) AE0116839 C) AE0116841 C) AE0116843 C) AE0116844 C) AE0116846 C) AE0263792 C) AE0263793 C) AE0264606 C) AE0264608 M20 cable C) AE0296317 inlet, approval option A, with HART communication start-up at <3.6mA, M20 cable C) AE0296319 inlet, approval option C, with HART communication start-up at <3.6mA, M20 cable C) AE0296320 inlet, approval option E, with HART communication start-up at <3.6mA, M20 cable C) AE0296322 inlet, approval option F, with HART communication start-up at <3.6mA, M20 cable C) AE0296323 inlet, approval option G, with HART communication start-up at <3.6mA, NPT cable C) AE0263792 inlet, approval option A, with FOUNDATION Fieldbus TM communication, no process connection M20 cable C) AE0263793 inlet, approval option A, with FOUNDATION Fieldbus TM communication, no process connection NPT cable C) AE0264606 inlet, approval option C, with FOUNDATION Fieldbus TM communication, no process connection M20 cable C) AE0264608 inlet, approval option C, with FOUNDATION Fieldbus TM communication, no process connection Siemens FI 01 2010 /229

horn antenna and extension kits 38 mm (1.") horn antenna kit, C) AE011139 1." Process Connections only 100 mm (4") horn antenna extension kit, AE01113 1." Process Connections only 0 mm (2") stainless steel 316L horn antenna kit C) AE011169 7 mm (3") stainless steel 316L horn antenna kit C) AE011171 100 mm (4") stainless steel 316L horn antenna kit C) AE011173 100 mm (4") horn antenna extension kit, 0 mm C) AE011177 (2"), 7 mm (3") and 100 mm (4") process connection 0 mm (2") horn antenna kit, Hastelloy C-22 J) AE011184 7 mm (3") horn antenna kit, Hastelloy C-22 J) AE01118 100 mm (4") horn antenna kit, Hastelloy C-22 J) AE011187 Dupont 1Gr Polyback, PTFE grease kit C) AE0111626 LR20 lid with O-ring AE0246410 C) Subject to export regulations AL: N, ECCN: EAR99 J) Subject to export regulations AL: 9I999, ECCN: EAR99 Please contact nacc.smpi@siemens.com for special requests. /230 Siemens FI 01 2010

Characteristic curves Ambient/Process Flange Surface Temperature Curve Siemens FI 01 2010 /231

Dimensional drawings dimensions /232 Siemens FI 01 2010

Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Shield for HART, PROFIBUS PA and FOUNDATION Fieldbus Instrinsically Safe versions only. gland Notes: 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC 61010-1. 2. All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable (14 to 22 AWG) for HART version. 4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. Hand Programmer Part number: 7ML1930-1BK C connections Siemens FI 01 2010 /233