with type designation(s) ECO38, -40, -43, -46 and ECP32, -34, 3 phases, 4 poles, single or double bearings, brushless A.C. generator.

Similar documents
TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

50 Hz 60 Hz VOLTAGE Connections

THE RESEARCH COMMITTEE FOR TOTAL ENERGY THE ENERGY CONSERVATION STANDARDS WORKING GROUP SUMMARY OF FINAL CRITERIA

MXB GENERATOR SERIES kva - 50 Hz V 12,5-200 kva - 60 Hz V

COVER PAGE FOR TEST REPORT

DT100 family (12 V, 24 V, 48 V) TDK-Lambda. TDK-Lambda UK Ltd. Kingsley Avenue, llfracombe, Devon, EX348ES, UK

Page 1 of 7 Attachment to IECEx TUN Issue 0

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

Type Approval Certificate

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

P Output Ratings. Dimensions and Weights. Prime Rating

Alternator. Ratings Book. Industrial. Edition 2

A V 50Hz / V 60Hz

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

P1350P1/P1500E1 50Hz

COMBROMXB001_C 10/2018 MXB GENERATOR SERIES kva - 50 Hz V 12,5-200 kva - 60 Hz V

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

multi-function meters

Generator protection relay

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

COVER PAGE FOR TEST REPORT

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Series CT7N Bimetallic Overload Relays

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Pendant Light Fitting IEC Series 6470/2

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

TeSys circuit-breakers

Certificate of Calibration

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Bulletin 190 IEC Modular Starter System

MILLITARY SPECIFICATION SHEET

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Kuhnke Technical Data. Contact Details

Certificate of Calibration

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Indoor Linear 80W Driver SI-C215280N2KR

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

WE-EF LEUCHTEN. Technical information for Eco Step Dim Basic. Product ID

GV2ME. Main. Device short name. Device application

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

ELECTRICAL SAFETY INSPECTION REPORT

Calibration Certificate

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

GV2P05. Main. Device short name. Device application

OT 100/ /700 P5

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

llen-bradley 194R-HM4-NFPA3

Model Number Structure

SMALL OIL SEALED PUMPS

Circuit-Breakers for Motor Protection Series 8523/8

4-in-1 Motor Controller CAN

MVSI-TS. Technical features

Operating Instructions Dimmer for V Incandescent Lamps

LED Driver Linear / area fixed output

GV2ME. Main. Device short name. Device application

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Benefits. Applications

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

High performance circuit breakers

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

File E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised:

DC POWER SYSTEMS CATALOG

Technical Information

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

Transcription:

Certificate No: TAE000017N File No: 821.10 Job Id: 262.1-006761-4 This is to certify: That the Generator with type designation(s) ECO38, -40, -43, -46 and ECP32, -34, 3 phases, 4 poles, single or double bearings, brushless A.C. generator. Issued to M.E.C.C. ALTE S.P.A. CREAZZO VI, Italy is found to comply with DNV GL rules for classification Ships and offshore units Application : Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. Enclosure class Insulation class Temp. class Voltage class Power class Frequency class Speed IP 23(IP45) H B, F or H Up to 690 V (star connection) Up to 3226 kva 50 or 60 Hz 1500 or 1800 RPM This Certificate is valid until 2021-06-23. Issued at Høvik on 2017-02-15 DNV GL local station: Venice for DNV GL Approval Engineer: Nicolay Horn Andreas Kristoffersen Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 1 of 5 DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

Name and place of manufacturer M.E.C.C. ALTE S.P.A. CREAZZO VI, Italy M.E.C.C. ALTE U.K. Ltd. Oakham, Rutland, United Kingdom Product ECO38, -40, -43, -46 and ECP32, -34, 3 phases, 4 poles, single or double bearings, brushless A.C. generator. Enclosure class: IP 23 or IP 45 Winding insulation: Class H Temperature rise limits: Class B, F or H Voltage class: Up to 690 V (star connection) Power class: Up to 3226 kva Frequency class: 50 or 60 Hz Speed: 1500 or 1800 RPM Rating class H: [kva] Amb 45 C ECP32 2S4 33,6 33,6 33,6 40,3 40,3 40,3 40,3 40,3 ECP32 3S4 40,8 40,8 40,8 49 49 49 49 49 ECP32 1M4 48 48 48 57,6 57,6 57,6 57,6 57,6 ECP32 2M4 60 60 60 68,6 70,6 72,6 72,6 72,6 ECP32 3L4 72 72 72 82,3 84,4 86,4 86,4 86,4 ECP32 4L4 76,8 76,8 76,8 88 90 92 92 92 ECP34 1S4 81,6 81,6 81,6 97,9 97,9 97,9 97,9 97,9 ECP34 2S4 101 101 101 121 121 121 121 121 ECP34 1L4 130 130 130 144 150 156 156 156 ECP34 2L4 144 144 144 163 168 173 173 173 ECP34 3L4 149 154 154 177 180 184 184 184 ECO38 1S4 173 173 173 211 211 211 211 211 ECO38 2S4 192 192 192 230 230 230 230 230 ECO38 3S4 216 216 216 259 259 259 259 259 ECO38 1L4 230 240 230 288 288 288 288 288 ECO38 2L4 278 288 288 326 336 346 346 346 ECO38 3L4 336 336 336 403 403 403 403 403 ECO40 1S4 384 384 384 432 446 461 461 461 ECO40 2S4 432 432 432 490 504 518 518 518 ECO40 3S4 480 480 480 557 566 576 576 576 ECO40 1L4 528 528 518 605 619 634 634 634 ECO40 1.5L4 595 595 595 672 693 714 714 714 ECO40 2L4 653 653 653 749 766 783 783 783 ECO40 VL4 720 720 720 864 864 864 864 864 ECO43 1S4 768 768 768 922 922 922 922 922 ECO43 2S4 893 893 893 1018 1044 1071 1071 1071 ECO43 1M4 984 984 984 1181 1181 1181 1181 1181 ECO43 2M4 1104 1104 1008 1248 1296 1344 1344 1344 ECO43 2L4 1248 1248 1248 1423 1460 1498 1498 1498 ECO43 VL4 1344 1344 1344 1613 1613 1613 1613 1613 Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 2 of 5

Rating class H: [kva] Amb 45 C ECO46 1S4 1440 1440 1440 1650 1690 1730 1730 1730 ECO46 1.5S4 1584 1584 1584 1804 1852 1900 1900 1900 ECO46 2S4 1730 1730 1730 1970 2020 2080 2080 2080 ECO46 1L4 2016 2016 2016 2300 2360 2420 2420 2420 ECO46 1.5L4 2208 2208 2208 2515 2580 2650 2650 2650 ECO46 2L4 2400 2400 2400 2730 2800 2880 2880 2880 ECO46 VL4 2592 2688 2592 2956 3043 3131 3226 3226 Rating class F: [kva] Amb 45 C ECP32 2S4 30,8 30,8 30,8 37 37 37 37 37 ECP32 3S4 37,4 37,4 37,4 45 45 45 45 45 ECP32 1M4 44 44 44 52,8 52,8 52,8 52,8 52,8 ECP32 2M4 58,2 58,2 58,2 62,9 64,7 66,5 66,5 66,5 ECP32 3L4 66 66 66 75,4 77,3 79,2 79,2 79,2 ECP32 4L4 70,4 70,4 70,4 80,6 82,5 84,3 84,3 84,3 ECP34 1S4 74,8 74,8 74,8 89,8 89,8 89,8 89,8 89,8 ECP34 2S4 92,4 92,4 92,4 111 111 111 111 111 ECP34 1L4 118 118 118 132 137 142 142 142 ECP34 2L4 132 132 132 150 154 158 158 158 ECP34 3L4 135 140 140 163 166 169 169 169 ECO38 1S4 158 158 158 194 194 194 194 194 ECO38 2S4 176 176 176 211 211 211 211 211 ECO38 3S4 198 198 198 238 238 238 238 238 ECO38 1L4 211 220 211 264 264 264 264 264 ECO38 2L4 255 264 264 299 308 317 317 317 ECO38 3L4 308 308 308 370 370 370 370 370 ECO40 1S4 352 352 352 396 409 422 422 422 ECO40 2S4 396 396 396 449 462 475 475 475 ECO40 3S4 440 440 440 510 519 528 528 528 ECO40 1L4 484 484 475 554 568 581 581 581 ECO40 1,5L4 546 546 546 616 635 655 655 655 ECO40 2L4 598 598 598 686 702 718 718 718 ECO40 VL4 690 690 690 829 829 829 829 829 ECO43 1S4 704 704 704 845 845 845 845 845 ECO43 2S4 818 818 818 933 957 982 982 982 ECO43 1M4 902 902 902 1082 1082 1082 1082 1082 ECO43 2M4 1008 1008 920 1133 1180 1227 1227 1227 ECO43 2L4 1144 1144 1144 1304 1338 1373 1373 1373 ECO43 VL4 1232 1232 1232 1478 1478 1478 1478 1478 ECO46 1S4 1300 1300 1300 1470 1520 1560 1560 1560 ECO46 1.5S4 1452 1452 1452 1653 1697 1741 1741 1741 ECO46 2S4 1540 1540 1540 1750 1800 1850 1850 1850 ECO46 1L4 1825 1825 1825 2070 2130 2200 2200 2200 ECO46 1.5L4 2024 2024 2024 2305 2365 2429 2429 2429 ECO46 2L4 2160 2160 2160 2450 2520 2600 2600 2600 ECO46 VL4 2375 2463 2375 2709 2789 2870 2957 2957 Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 3 of 5

For class B rating temperature rises, multiply class H rating by 0,792 For degree of protection IP45 (fitting an air inlet filter and air outlet filter), multiply class H rating by 0,74. For 50 C ambient temperature, multiply class H rating (or class F, or class B) by 0,97. Application/Limitation The generators are to be installed and tested in accordance with the Rules. Type Approval documentation Drawings: ECP32 B Shaft Drawing type M form B3B14 Shaft Drawing type M form MD35 A9471_01 A9466_01 A9193_00 A9196_00 A9194_00 A9197_00 9238_12 A5505_07 ECP34 A Shaft Drawing type S Shaft Drawing type L ECO38 A Shaft Drawing type S Shaft Drawing type L ECO40 B Overall dim drawing form MD35 Test Reports: A9950_00 A8993_02 A5546_03 A5544_03 A9497_02 A9496_02 A5825_04 A5826_05 A9550_00 A9551_00 ECO43 A ECO46 A A9449_01 A9446_01 A9450_01 A9447_01 A9451_01 A9448_01 A9502_02 A9501_02 A4052_05 A4049_05 A4050_05 A4051_05 A7916_01 A9222_00 A9504_03 A9503_03 A4641_11 A4643_08 A4642_11 A4644_08 A9373_00 A9090_00 ECO 32 2S/4 28-11-05 8 ECP 34 1S/4 28-11-05 8 ECO 38 1SN/4 29-11-05 8 ECO 40 1S/4 05-12-05 9 ECO 43 1SN/4 28-11-05 9 ECO 32 3L/4 28-11-05 9 ECP 34 2L/4 28-11-05 9 ECO 38 3LN/4 01-12-05 8 ECO 40 2L/4 30-11-05 9 ECO 43 2LN/4 30-11-05 9 ECO 46 1L/4 03-03-09 8 ECP32 2M4 18-12-15 9 ECP32 4L4 21-12-15 9 ECP34 3L4 25-05-16 9 Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 4 of 5

ECO38 3L4 09-06-16 9 ECO40 VL4 31-05-16 9 ECO43 1M4 01-06-16 9 ECO43 VL4 13-06-16 9 ECO46 VL4 21-03-16 17 Tests carried out Overspeed, high voltage, winding resistance, temperature rise at full load, insulation resistance, overload, short circuit curve, no load test, voltage variation under transient condition tests and excitation voltage. Marking of product The products are to be marked with the following specifications: Manufacturers name and type designation Serial number and year of manufacture Voltage, frequency speed Power class (kva) / current Winding insulation class Degree of protection Periodical assessment The scope of the periodical assessment survey is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the survey are: Inspection of factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Type Approval Certificate. Survey to be performed at least every second year. END OF CERTIFICATE Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 5 of 5