Agilent 87075C Multiport Test Set Product Overview

Similar documents
Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent 11713A Attenuator/Switch Driver

Broadcast Television Measurements

Agilent E5100A Network Analyzer

Agilent 81600B Tunable Laser Source Family

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

Agilent I 2 C Debugging

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Agilent MSO and CEBus PL Communications Testing Application Note 1352

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

Agilent 8712B and 8714B RF Economy Vector Network Analyzers

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

We bring quality to light. SNT 10 DC Power Supply

Debugging Digital Cameras: Detecting Redundant Pixels

Microwave Counter, Power Meter and DVM in One Portable Package

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Agilent E4430B 1 GHz, E4431B 2 GHz, E4432B 3 GHz, E4433B 4 GHz Measuring Bit Error Rate Using the ESG-D Series RF Signal Generators, Option UN7

R&S ZN-Z85 Switch Matrix Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S ZVA110 Vector Network Analyzer Specifications

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

E4416A EPM-P Series Single Channel Power Meter

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

R&S ZND Vector Network Analyzer Specifications

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

Agilent 4-Port PNA-L Microwave Network Analyzer

JD725A Cable and Antenna Analyzer - Dual Port

PAM-1840 Preamplifier Operation Manual

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

Full-featured CW Microwave Counters for Field, Factory or Lab

R&S ZN-Z154 Calibration Unit Specifications

Installation Note. Option GHz Operation Upgrade Kit. For 8753E and 8753ES Network Analyzers. Applicable Upgrade Kit Model Number

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Agilent PN Time-Capture Capabilities of the Agilent Series Vector Signal Analyzers Product Note

8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit. Applicable Upgrade Kit Model Number

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

Agilent CSA Spectrum Analyzer N1996A

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Advanced Test Equipment Rentals ATEC (2832)

R&S ZNBT Vector Network Analyzer Specifications

Assembly Level Service Guide

Agilent M9362A-D01-F26 PXIe Quad Downconverter

USB-TG124A Tracking Generator User Manual

PiMPro Rack Mount Analyzer

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

DISTRIBUTION AMPLIFIER

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Single-Output 2000 W

NS-3 RF Noise Source Operation Manual

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

NI PXI/PXIe-2543 Specifications

R&S HF907DC SHF Downconverter Specifications

Noise Detector ND-1 Operating Manual

LT-82 Stationary IR Transmitter

R-1580A Microwave Downconverter. Product Brochure

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Advanced Test Equipment Rentals ATEC (2832)

R&S FPC-Z10 Teaching Kit Getting Started

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

PiMPro Portable Analyzer PiMPro Classic 1821

R&S RT-Zxx High-Voltage and Current Probes Specifications

DA E: Series of Narrowband or Wideband Distribution Amplifiers

1/3 RACK-MOUNTED BLOCK CONVERTERS

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

Model /29S RF Splitter

Agilent Series Preselected Millimeter Mixers

Agilent N5183A MXG Microwave Signal Generator

In-Line or 75 Ohm In-Line

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

clipping; yellow LED lights when limiting action occurs. Input Section Features

SCALE & WEIGHT DISPLAYS

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Keysight Technologies ad Integrated RF Test Solution

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

MULTIBAND 1/3 RACK-MOUNTED

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

VIDEO MATRIX SWITCHES HDMI 2.0

DA : Series of Narrowband or Wideband Distribution Amplifiers

R&S FSW-K144 5G NR Measurement Application Specifications

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

Monoblock RF Filter Testing SMA, In-Fixture Calibration and the UDCK

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S RT-Zxx Standard Probes Specifications

Agilent 8720E Family Microwave Vector Network Analyzers

USB Smart Power Sensor

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

Transcription:

Agilent 87075C Multiport Test Set Product Overview A complete 75 ohm system for cable TV device manufacturers Now, focus on testing, not reconnecting! For use with the Agilent 8711 C-Series of network analyzers 3 MHz to 1.3 GHz Optional two, six, or twelve ports

Get higher device-test throughput with a complete system solution from Agilent System solution for multiport device testing An Agilent Technologies 87075C test set coupled with an Agilent 8711Cseries network analyzer offers far more than just switching capability. This complete solution offers fast measurement speed, ease of use, and convenience, as well as vastly improved calibration times (typically a 20 times improvement). The test set and network analyzer are fully specified at the test ports as a system, so your customers can have the most confidence in your products. Plus, you don t have the extra expense of an external computer and the extra development of calibration and control software to worry about with an 8711 C-Series analyzer you get full internal switching and calibration control of the test system. Quickly and completely characterize your devices with a single connection The Agilent test system eliminates time-consuming reconnections of a device to a two-port network analyzer to test all its signal paths. By saving time, you keep your costs down and your volumes up so you can remain competitive in the fast-growing cable- TV device manufacturing industry. Improve your device throughput and test accuracy An Agilent 87075C test set coupled with an 8711 C-Series RF network analyzer offers: Significant improvements in calibration time and the accuracy of your measurements, all with a single connection Local area networking capability and advanced automation capabilities for local and distributed control The 8711 C-Series of RF network analyzers Designed for high-volume production LAN capability Efficiently send new test parameters, test limit lines, and gather test data from your production line IBASIC Optional built-in BASIC instrument controller for easy automation Pass/fail testing Automated pass/fail testing instantly and consistently compares measured data to your test limits Large 9-inch display See test results on a large easy-toread display The 87075C multiport test set Designed to improve your device throughput 3 MHz to 1.3 GHz, 75 ohm Aimed at testing cable-tv devices Innovative SelfCal technique For fast, accurate measurements Solid-state switching For reliable, repeatable, and fast switching Optional two, six, or twelve port test sets To meet all your multiport devicetest needs 2

Get fast, accurate measurements with an unprecedented calibration technique New SelfCal technique With its advanced internally automated calibration capability, the 87075C is shipped from Agilent already calibrated at all measurement ports. You can use this default test-set calibration or complete your own test-set calibration. Now, between test-set calibrations, the system can be calibrated in a few seconds on-line with SelfCal. SelfCal uses transfer standards located inside the test set to bring the system to the same measurement-accuracy level as your test-set calibration. You save all the time previously required to connect the external standards, which is typically a 20-time improvement. Increase customer confidence in your products with a fully specified system For RF measurements, the calibration and RF specifications must be at the actual measurement ports. The 87075C coupled with an 8711 C-Series analyzer offers a fully specified test system. Now you can correlate measurements across different test systems, and reduce your measurement uncertainties, which means you can tighten your product specifications and increase your competitiveness! Agilent fully specifies the network analyzer and test set as a system so you have a complete measurement platform. HP fully specifies the network ana Reduce system-calibration time A typical calibration time is one hour per shift per instrument for a monthly total of about 20 hours. SelfCal reduces this time to approximately 1 hour per month! You can easily set up the calibration intervals, so the analyzer does the work automatically. Cut your system-calibration time by up to 20 times with the innovative SelfCal technique. Reduce the number of RF connections The 87075C test set provides switching capability to all measurement ports, which reduces RF interconnects. Connect your device only once, and quickly and easily measure all its signal paths and ports. By reducing the number of RF connections you also: Decrease tune-and-test times Reduce operator fatigue Lower risk of misconnection Reduce wear on cables, fixtures, connectors, and the device under test 3

Designed for cable TV multiport device manufacturing Taps and splitters The 87075C multiport test set can be used with a quick-connect fixture to allow fast and easy high-volume testing of the frequency response, return loss, and isolation between all tap and splitter ports. Distribution and trunk/bridger amplifiers Use the Agilent multiport test system to test forward-and-reverse frequency response, gain, and slope as well as return loss on all amplifier ports. You can also test the isolation between all the amplifier s outputs. Splitters Distribution amplifier Trunk/Bridger amplifier Taps Cable TV distribution system showing typical multiport devices that can be measured with the Agilent 87075C multiport test set and 8711 C-Series network analyzer system 4

The Agilent multiport test system helps you: Reduce the number of connections by providing switching capability for the required number of measurement ports Reduce the time necessary for calibration with an innovative calibration technique with installation and on-line calibration (SelfCal) Get a fully specified system at the RF measurement ports for a verifiable interface Compatibility The 87075C multiport test set is compatible with the 8711C, 8712C, 8713C and 8714C RF network analyzers configured with the 75-ohm Option 1EC. The Agilent 87075C multiport test set coupled with the 8711 C-Series of RF network analyzer helps you get high device throughput. 5

Additional productivity and ease-of-use features LAN connection for system networking Optional local-area-network (LAN) connectivity provides a complete interface to your test-process-management software systems. The Agilent 8711 C-Series provides the improved device analysis and data-archival requirements that customers and regulatory agencies demand. Make forward and reverse measurements with a T/R network analyzer By using an external multiport test set like the 87075C with an 8711C, both forward and reverse transmission and reflection measurements can be made with a single connection. Easy programming for automation With the Agilent 8711C Instrument BASIC (IBASIC) option, you get a fullfeatured, built-in instrument controller for fast, flexible, and complete measurement customization. Even if you don t have programming experience, you can use IBASIC to perform complex computation and control to record keystrokes and automate your manual measurements. Large display and external VGA monitor Your technicians and operators will appreciate how the large display of the analyzer enhances their ability to see measurement information in your manufacturing environment. You can also connect an analyzer to a standard VGA monitor and see measurement results in color on an even larger and easier-to-read screen. In this example, a two-port test set allows a transmission/reflection-based network analyzer to make measurements in both forward and reverse directions. Rear-panel connectivity LAN capability GPIB, Centronics parallel, and RS-232C serial interfaces VGA output TTL-level signal for part-handler control DIN Interface 6

Agilent 87075C specifications and characteristics 1 Frequency range Noise floor 2 3 MHz to 1300 MHz 84 dbm SelfCal calibration time 4 Reflection Transmission 2 seconds 4 seconds Receiver dynamic range Measurement dynamic range 3 Connector type See 8711 C-Series technical specifications 60 db Type-N Female, 75 Ohm Line power Frequency Voltage 47 to 60 Hz 115 V nominal (90 V to 132 V) or 230 V nominal (198 V to 264 V). A third-wire ground is required. Maximum test port power Measurement Level Damage Level Port-to-port isolation Port-to-port insertion loss Reflection to Port n Port n to Transmission Multiport system residuals Transmission Measurement Source Match Corrected Uncorrected Load match Reflection Measurement Directivity Source Match Corrected Uncorrected Load Match +16 dbm +20 dbm 60 db 6 db 7 db 30 db 14 db 16 db 40 db 30 db 14 db 20 db Cabinet dimensions Weight Net Shipping Environmental characteristics 132.8 mm H x 425 mm W x 495 mm D 7.7 kg 11.3 kg General conditions ESD (electrostatic discharge) must be eliminated by use of static-safe work procedures and an antistatic bench mat. Operating environment (Indoor use only) Operating temperature 0 to 55 C Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C Altitude up to 4,572 meters (15,000 ft) Port Switching Time Test Set Settling Time 1 second 10 msec 1. This part provides several types of performance information: Specifications describe the test set s warranted performance over a temperature range of 20 C to 30 C, unless otherwise stated. Supplemental Characteristics (indicated by italics) are typical, but nonguaranteed parameters, intended to provide useful information in using the product. Non-Operating Storage Conditions Temperature 40 C to +70 C Humidity 0 to 90% relative at +65 C (noncondensing) Altitude 0 to 15,240 meters (50,000 ft) The following conditions must be met for the test set to meet its specifications: The test set must be used with an Agilent 8711C, 8712C, 8713C or 8714C network analyzer (with 1-MByte SRAM and firmware revision 4.5 or later). The analyzer must have had its performance verified within the last year. Both instruments must be warmed up for at least 30 minutes after turn-on. A valid test-set calibration must have been performed on the system within the last 30 days using valid standards. A SelfCal must have been performed by the system within the last 60 minutes. 2. Medium-wide system bandwidth. 3. Limited by port-to-port isolation. 4. Assumes 201-point measurement, medium-system bandwidth. 7

Ordering information Agilent 87075C multiport test set Includes: Power cord, test-set calibration disk as well as: 87075-60026 Interconnect cable (reflection port) 87075-60028 Interconnect cable (transmission port) 8120-6818 Parallel port interface cable 87075-90005 87075C User s and Service Guide Standard options (Must order one of the following options with 87075C) Option 002 Two-port system Option 006 Six-port system Option 012 Twelve-port system Other options Option 1CM Rack-mount kit Includes: 87075-60027 Interconnect cable (reflection port) 87075-60029 Interconnect cable (transmission port) (These cables are shipped with Option 1CM only. Use these cables if you are rack-mounting your system, or if the bottom feet of the analyzer have been removed.) Option UK6 Commercial calibration certificate with data 87075-60026 87075-60028 8120-6818 Also available (order separately) Cables 8120-2408 75 ohm Type-N to Type-N cable (M-M) 8120-2409 75 ohm Type-N to Type-N cable (M-F) 8120-8396 75 ohm Type-N to Type-F cable (M-M) 8120-8397 75 ohm Type-N to Type-F cable (M-F) Precision adapters 85039-60010 Type-N (M) to Type-F (M) 85039-60011* Type-N (F) to Type-F (M) 85039-60013* Type-N (M) to Type-F (F) 85039-60014 Type-N (F) to Type-F (F) 85039-60002* Type-F (F) to Type-F (F) 85039-60006* Type-F (M) to Type-F (M) 85039-60012 Type-F (M) to Type-F (F) *included in 85039B Commercial adapters 1250-2350 Type-F (F) to Type-F (F) 1250-2369 Type-N (M) to Type-F (M) 1250-2368 Type-N (F) to Type-F (M) Calibration kits HP 85039B 75 ohm Type-F calibration kit Option 00M Male standards only Option 00F Female standards only HP 85036B 75 ohm Type-N calibration kit HP 85036E Economy 75 ohm Type-N calibration kit Related products Agilent 87075A/B custom multiport test sets. See literature number 5964-3830E for further information. Multiple switching test sets are also available through Agilent s special handling. Option 002 Option 006 Option 012 8120-2408 8120-2409 8120-8396 8120-8397 85039-60010 85039-60011 85039-60013 85039-60014 85039-60002 85039-60006 85039-60012 1250-2350 1250-2369 1250-2368 8

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extracost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test and measurement needs. Online Assistance www.agilent.com/find/assist Phone or Fax United States: (tel) 1 800 452 4844 Canada: (tel) 1 877 894 4414 (fax) (905) 206 4120 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Australia: (tel) 1 800 629 485 (fax) (61 3) 9272 0749 New Zealand: (tel) 0 800 738 378 (fax) (64 4) 495 8950 Asia Pacific: (tel) (852) 3197 7777 (fax) (852) 2506 9284 Product specifications and descriptions in this document subject to change without notice. Copyright 1997, 2000 Agilent Technologies Printed in U.S.A. 7/00 5965-8165E