S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Similar documents
Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

The Cathode Ray Tube

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

OSCILLOSCOPE AND DIGITAL MULTIMETER

RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

University of Utah Electrical Engineering Department EE1050/1060 Oscilloscope. Name:, Lab TA:

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Using an oscilloscope - The Hameg 203-6

Beginners How to Test DSO138mini

CATHODE-RAY OSCILLOSCOPE (CRO)

Physics 123 Hints and Tips

Choosing an Oscilloscope

BME 3512 Biomedical Laboratory Equipment List

4.9 BEAM BLANKING AND PULSING OPTIONS

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

What to look for when choosing an oscilloscope

CHAPTER 4 OSCILLOSCOPES

4. ANALOG TV SIGNALS MEASUREMENT

Advanced Test Equipment Rentals ATEC (2832)

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

"shell" digital storage oscilloscope (Beta)

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

Experiment # 4 Counters and Logic Analyzer

How advances in digitizer technologies improve measurement accuracy

Presented by: Amany Mohamed Yara Naguib May Mohamed Sara Mahmoud Maha Ali. Supervised by: Dr.Mohamed Abd El Ghany

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

INSTRUCTION MANUAL Model 2522C. 20 MHz DIGITAL STORAGE/ANALOG OSCILLOSCOPE

INSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017

PicoScope 6407 Digitizer

What is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga

PicoScope 6407 Digitizer

Newly developed CCD scan converter tube inside! The Highest Frequency Bandwidth in the world TS-81000/ Iwatsu Test Instruments Corp.

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

h c HUNG CHANG D IBM PC 586, Pcntium Software Drive : Windows 95 Dual Clmnel Sampling per channel : 100 MS/s

2 MHz Lock-In Amplifier

Inmarsat Downconverter Narrowband Downconverter

Activity P32: Variation of Light Intensity (Light Sensor)

CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR

These are used for producing a narrow and sharply focus beam of electrons.

What is sync? Why is sync important? How can sync signals be compromised within an A/V system?... 3

GDB-03 Demo Module USER MANUAL GW INSTEK PART NO. 82DB-03000M01 ISO-9001 CERTIFIED MANUFACTURER

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Exercise 1-2. Digital Trunk Interface EXERCISE OBJECTIVE

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

GFT Channel Digital Delay Generator

Agilent Technologies 54522A

CATHODE RAY OSCILLOSCOPE (CRO)

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 105 MSPS ADC

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

BLOCK DIAGRAM. Brightness Control -120V. Vertical Blanking, FBT 30V 15V. Protection TDA8172 ( IC601) Circuit -12V 12V. H/V Sync Processor

Errata. Title & Document Type: Manual Part Number: Revision Date: HP References in this Manual

MP212 Principles of Audio Technology II

Expect to Make Waves.

Experiment 9 Analog/Digital Conversion

Measuring with digital storage oscilloscopes

VGA Port. Chapter 5. Pin 5 Pin 10. Pin 1. Pin 6. Pin 11. Pin 15. DB15 VGA Connector (front view) DB15 Connector. Red (R12) Green (T12) Blue (R11)

Elements of a Television System

Dan Schuster Arusha Technical College March 4, 2010

2016 RIGOL TECHNOLOGIES, INC.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Agilent 6000 Series Oscilloscope Demo Guide

Viewing Serial Data on the Keysight Oscilloscopes

Digital Storage Oscilloscopes 2550 Series

Introduction to the oscilloscope and digital data acquisition

Oscilloscopes for field applications

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

Procurement of IC TESTER & TRAINER KITS, OSCILLOSCOPES, FG S, DECADE BOXES AND ANALOG METERS

ScopeMeter 190 Series Specifications

imso-104 Manual Revised July 19, 2012

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

R2001A/B/C Service Monitor Alignment Sections

15 Inch CGA EGA VGA to XGA LCD Wide Viewing Angle Panel ID# 833

Experiment 13 Sampling and reconstruction

GME. User s Manual. Rev 1.3

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

Lab 1 Introduction to the Software Development Environment and Signal Sampling

MAIN PCA TEST PROCEDURE DOCUMENT NUMBER:

User's Manual. Rev 1.0

Viewing Serial Data on the Keysight Oscilloscopes

263 Series LED Bargraph Indicator and Controllers

Spectrum Analyser Basics

Tutorial Cathode Rays Year 12 Physics - Module 9.3 Motors and Generators

Introduction. Fiber Optics, technology update, applications, planning considerations

ENJOY YOUR BOOKS PLEASE VISIT OUR STORE FOR EVEN MORE GREAT STUFF! COPYRIGHT NOTICE ALL MATERIALS INCLUDING CD/DVD AND

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

OPERATING INSTRUCTIONS FOR SYLVANIA. Type I08 Cathode-Ray Oscilloscope. Sylvania Electric Products Inc. Industrial Apparatus. Emporium, Pennsylvania

Operating Instructions Digital Color Monitor

Synthesized Clock Generator

Logic Analysis Basics

Swept-tuned spectrum analyzer. Gianfranco Miele, Ph.D

Transcription:

ET 150 Scope Controls Learning Objectives In this lesson you will: learn the location and function of oscilloscope controls. see block diagrams of analog and digital oscilloscopes. see how different input coupling affects displayed signals. learn how to set oscilloscope controls to make measurements learn how to set the triggering controls to stabilize a scope display. examine scope probe operation. see how to compensate a scope probe. determine how scope bandwidth affects measurement accuracy 1

Agilent 54622D Scope Controls Dual Trace Digital Storage scope with digital signal monitoring. Horizontal Controls Display Function Keys Intensity (Brightness) Power Switch Trigger Controls Vertical Controls Vertical and Horizontal Scale Controls Agilent 54622D Scope Dual Channel Digital Scope displays two synchronized signals Time Scaling sec/div Channel on/off Channel 1 Input Horizontal Position Voltage Scaling V/div Vertical Position Channel 2 Input 2

Inside an Analog Scope Cathode Ray Tube Electron beam strikes phosphor on tube face Digital Scopes vs Analog Scopes Measured voltage turned into series of samples Analog to digital converter Samples stored and displayed on screen Performance limited by sampling rate One-time events captured and displayed. Not possible with analog scopes 3

Vertical Input Coupling Ac or Dc Setting DC coupling passes both ac and dc voltages AC coupling passes only ac part of signal Setting the Oscilloscope for Measurement Connect probe(s) to scope input (1x or 10x) 10x expands range increases accuracy Adjust screen display (brightness and focus) Adjust vertical gain to expected range of input If range unknown set to maximum Select proper coupling of input Ac coupling blocks dc signal and passes ac only Dc coupling passes both ac and dc signals Adjust time scaling to expected range of input signal Set triggering source and level 4

Scope Triggering Basics A properly triggered scope will have a stable screen display Trace starts at different point each sweep Trace starts at same point each sweep Time Sweep Time Sweep Un-triggered Display Triggered Display Trigger Level and Slope Trigger controls compare the signal edge to user-set levels and polarity (+/- slope) Trigger Level determines where on signal edge the trigger point occurs Trigger Slope determines whether trigger point occurs on rising or falling edge. 5

Trigger Level and Slope Trigger level and slope example Positive Slope triggering 3V level 3 V Negative Slope triggering 3V level Trigger Sources Input Channels Input used to start time sweep Most commonly used Power Source (Line Trigger) Trigger signal derived from power line of scope Ideal for triggering signals based on wall power Locks on signal that are multiples of 60 Hz External Source Signal not derived from inputs Additional signal must be applied 6

Trigger Modes Trigger Mode determines how and when the scope displays the signal Common Trigger Modes Auto causes scope to sweep trace without input signal applied. Display does not disappear when signal removed. Most commonly used setting Normal only causes scope to sweep trace when signal is applied at has appropriate trigger level and slope. With no input, no display on analog scope or frozen display on digital scope. Triggering Controls Agilent 54622D Trigger Mode Trigger Level Trigger Slope Edge and Mode buttons produce menu choices above function keys on the display 7

Scope Probes Probes connect the scope to the circuit under test Connecting any instrument to an electric/electronic circuit changes the measured value Probe I scope Scope Scope and probe draw current changing the circuit Scope Probes 10x probes draw less current from circuit under test 10x probes give best results Probe Tip Ground Lead BNC Connector to Scope Probe kit Probe kit 8

Probe Compensation 10x probes must be adjusted to give best performance. This is called probe compensation. 10x probe forms a voltage divider with parallel capacitance. An adjustable capacitor eliminates this effect. Square wave test signal used to make necessary adjustment Under compensated Adjust probe until perfect square wave results Over compensated High frequencies reduced Low frequencies reduced Scope Frequency Response Scope must have sufficient frequency response (Bandwidth) to accurately reproduce signals. Lack of bandwidth prevents scope from displaying rapidly changing signals 4 GHz Limited bandwidth effects lack of frequency resolution distorted amplitude lost signal edges lost signal details 1 GHz 250 MHz Five Times Rule Required Bandwidth = 5 x highest measured frequency 9

ET 150 Coming Next: Electrical Connections 10