HiTECH Technologies, Inc.

Similar documents
Process Transmitter RMA 422

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Assembly. Front view. LEDs. Parametrization interface. Power Bus

02/11/2015

Process transmitter RMA422

Level Measurement silometer FMC 420, FMC 423

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Kuhnke Technical Data. Contact Details

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Model IQ4-PC User Manual Revision Date:

Capacitance Limit Detection nivotester FTC 420/421/422

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

LED Driver Compact fixed output

Ordering details. Approval. Classification

LED Driver Linear / area fixed output

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 331i / DMP 333i LMP 331 i

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

MICROMASTER Encoder Module

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

LED Driver Compact fixed output

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

1900/25 Vibration Monitor

Series CT7N Bimetallic Overload Relays

SAUTER flexotron RDT405 Manual

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

LED control gear Compact fixed output

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

Datasheet - SRB301LC 24VAC/DC

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

263 Series LED Bargraph Indicator and Controllers

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Figure 1: Device components

LED Driver Compact fixed output

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Datasheet - SRB-E-201ST

MILLITARY SPECIFICATION SHEET

CAMTO LTD. Arc detecting system DC/AC

Inductive sensor BI1.5-EG08K-Y1

Wall-/Pipe-Mount Level Indicator

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Capacitance Level Measurement Electronic insert FEC 12

AF-300 E11 Adjustable Frequency Drive

Actuators IC 20, IC 40

XT-17M-B relay - Delay-off, 1 C/O, 16 A

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

ADJUSTABLE SPEED DRIVES. nc1 Drive

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Sequential and Combination Timer TK-415 with RS-232 communication

Standard signal metering in wall-mounting case

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

Inductive sensor NI10-M18-Y1X-H1141

Gamma instabus. Technical product information

GP-500 SERIES - Low Voltage

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Model Number Structure

LED Driver Compact dimming

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

KRF EMC Filters Installation, Operation and Maintenance Manual

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Magnecraft Power Relays

Micro-DCI 53ML5100 Manual Loader

Single Point Flow Monitor SW118 SW119

Inductive sensor NI3-EG08K-Y1-H1341

User Manual RTHDBT402PT & RTHDBT402PR

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Multifunction Digital Timer

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

Transcription:

INSTCTION MANAL A TECHNOLOGY FO EVEY LEVEL APPLICATION nicont TM PKK-312 Current Controlled Switch Model PKK-312 HiTECH Technologies, Inc. 301 Oxford Valley oad - Building 505A - Yardley, PA 19067-7706 Tel: 215. 321. 6012; Fax: 215. 321. 6067 Tech Support (Toll Free) 866-DrLevel or 888-NIVELCO Email: info@drlevel.com or info@hitechtech.com Web Site: www.drlevel.com or www.hitechtech.com

1. APPLICATION NICONT PKK-312- series is a 4-20 ma, current controlled switch, the relay of which switches at currents (taught to the unit), depending on the limit, switching difference or window comparator s selected by programming. Fault condition monitoring can be switched on or off and it can be selected such that the relay will be energized or de-energized when detecting failure. Failure may be represented by discontinuity of cable/lower value fault current or short circuit/upper value fault current. The unit is suitable for powering all NIVELCO made 2-wire (4-20 ma) transducers. Some ls of this series meet requirements for intrinsically safe operation. NICONT PKK-312-8 unit is able without any further programming to monitor current levels of the DC powered, 2-wire NIVOSWITCH vibration fork both in damped and in vibrating s as well as to control relay output. 2. TECHNICAL DATA 2.1 GENEAL DATA TYPE Nominal input current range Accuracy of switching level/threshold level Discontinuity threshold/lower value fault current Short circuit threshold/pper value fault current Input impedance Input overload capability Damping elay PKK-312-1... 22 ma ± 0,1 ma 3,7 ma 22 ma 10 Ù maximum 100 ma (permanent) 0,1 s; 1 s; 2 s; 5 s selectable Output 1 piece SPDT ating 250 V AC, 8 A, AC1 Insulation strength 4000 V 50 Hz Electrical / Mechanical life time 10 5 / 2 x 10 6 switching Electrical connection max. 2,5 mm 2 twisted or maximum 4 mm 2 single cable Mechanical connection DIN EN 50022-35 rail mounted Ingress protection IP 20 Mass 2.2 Special data 0,21 kg EX APPOVED MODELS TYPE PKK-312-5 PKK-312-6 PKK-312-9 PKK-312-7 PKK-312-8 230 V AC±10% 110 V AC±10% 24 V AC±10% 24 V AC±10%, 50 60 Hz, Power supply range 50 60 Hz 50 60 Hz 50 60 Hz 24 V DC ±15% Power consumption < 2,5 VA < 2,5 VA ; < 2,5 W Switching levels 2 values in the range of 1 22 ma 10,5 ma 12,5 ma protection mark II (1) G [E ia] IIB II (1) G [Eia] IIC Intrinsically safe 0 < 28,4 V; I0 < 140 ma; P0 < 1,1 W; 0 < 28,4 V; I0 <80 ma; P0 < 0,6 W maximum values L0 < 6 mh; C0 < 50 nf L0 < 4 mh; C0 < 50 nf Output load IT=22 ma IT=22 ma when capability when OT12 V OT15 V Protection class Class II Class III Ambient temp -10 C... +55 C

TYPE Power supply range ODINAY MODELS PKK-312-1 PKK-312-2 PKK-312-3 PKK-312-4 230 V AC±10% 50 60 Hz 110 V AC±10% 50 60 Hz 24 V AC±10% 50 60 Hz Power consumption < 2,7 VA ; <2,5 W Switching levels 2 values in the range of 1 22 ma protection mark Intrinsically safe maximum values Output load capability 0 = 30 V I MAX = 70 ma OT min = 16 V 24 V AC±10%, 50 60 Hz, 24 V DC ±15% 0=24 V I MAX = 80 ma OT min = 23 V Protection class Class II Class III Ambient temp -10 C... +55 C 2.3 DIMENSIONS 3. INSTALLATION NICONT PKK-312- should be mounted on DIN EN 50022-35 rail. NOTE! Prior to the installation make sure that the input current values can be provided by the loop of the application. If not, teaching of the current values has to be carried out before installation and wiring. (See Point 5 Teaching current value of tripping point ) 4. WIING 4.1 EX MODELS PKK-312-8 with NIVOSWITCH vibrating fork 7 8 9 101112 PKK-312-7 with 2-wire transmitter (e.g. EchoTEK SEA-380-6 ) 7 8 9 10 1112 PKK-312-5 PKK-312-7 for monitoring of passive switch and cable 789 10 1112 = 1,5 k... 2 kω 4... 20 ma

4.2 Ordinary ls PKK-312-1 PKK-312-4 with 4-wire active transmitter (e.g. EchoTEK STA-360) PKK-312-1 PKK-312-4 with 4 wire active transmitter (e.g. MICOSONA TS-211) PKK-312-1 PKK-312-4 for monitoring of passive switch 789 10 1112 7 8 9 10 1112 7 8 9 101112 4... 20 ma + - I OT pl. 230 V AC AC power 4... 20 ma + - + - 24 V DC I OT = 1,5 k... 2 kω 5. INSTALLATIONS AND SETTING P After 3 s from power up the unit begins to work with the signals as per table of WOKING STATS. WOKING STATS LED Indication Interpretation (SELECT) FAIL (STEP) GEEN elay energised =1 ED elay de-energised =0 SIMLTANOS ED BLINKING OF BOTH LED GEEN ED Memory failure, elay state sustained No cable fault/no fault current. No cable monitoring Cable fault, or. fault current The state of the relay in accordance with the operation and depending on the input current will be as shown on the left hand diagram. Operation with delayed switching is demonstrated on the right hand diagram. IIN I 1 INPT CENT I 2 Limit 1 Limit 2 Switching difference Window Limit 1 ELAY STATE in working = 1 ELAY STATE in working = 0 t Tripping point current value Limit 2 Switching difference Window ELAY ENEGISED Adjusted switching delay State of the relay depending on the input current. < Switching delay elay operation with delayed switching. CATION! If on power up of a unit, set for switching differential, the value of the current will be between the two tripping points, the relay would always remain de-energized irrespectively of the relay operation ( = 1 or = 0) programmed before.

Depending on the actual task, programming of the unit may be needed which involves setting of the Operating Mode with the possibilities as below PKK-312-8 unit can be used without any programming for the powering and remote switching function of the Nivelco made DC powered, 2-wire NIVOSWITCH vibrating fork. Tripping point current values of 10,5 and 12,5 ma and switching differential operating cannot be changed! Setting possibilities: elay operating (Default: = 1) Monitoring of cable discontinuity (Default: NONE Monitoring of cable short circuit (Default: NONE) Damping (Default: 0,1 s) eturn to default PKK-312-1 PKK-312-7 Setting possibilities: Selection of comparison type (Default: Switching difference Teaching current value (Default: 10,5 ma és 12,5 ma) elay operating (Default: =1) Monitoring of cable discontinuity (Default: NONE) Monitoring of cable short circuit (Default: NONE) Damping (Default: 0,1 s) eturn to default POGAMMING Programming involves setting of operating and teaching of the input current. Programming / viewing operating Programming can be entered by pressing key A (for about 5s) till the LED POGAM lights up. While in programming by short pressing of key A the adjustment columns as per the table below can be accessed step by step. indicated by the relevant LED STEP. Being in the desired column the required raw can be selected by short pressing of key B indicated by the relevant LED SELECT. After performing adjustment needed, programming can be quit by pressing key A (for about 5s) till the LED POGAM goes off. POGAMMING / VIEWING OPEATING MODE Enter programming : press key A (for about 5s) till the LED POGAM lights up Adjustment columns with corresponding LED STEP states, accessed by short pressing of key A. GEEN elay operation = 1 = 0 -- GEEN BLINKING Comparator operation Limit value 1. Limit value 2. Switching diff. ED ED BLINKING OFF Cable short circuit */ monitoring lower current activated released Cable discontinuity */ monitoring upper current activated released Switching dely Adjustment raw with relevant state of the LED SELECT, selected by short pressing of key B 0,1 s GEEN 1 s GEEN BLINKING NO NO 2 s ED -- Window -- -- 5 s ED BLINKING Quit programming : press key A (for about 5s) till the LED POGAM goes off. * Cable monitoring can only be applied with certified 2-wire units.

Automatic quitting programming The unit will operate during programming in accordance with the previous parameters entered in the last completed programming. The new modified parameters will only be effective after quitting programming. Having left the transmitter in programming, it would after 30 s automatically quit programming. Since this represents uncompleted programming, the performed modification would not be effective. elay test Proper operation of the relay can be tested by pressing key B for about 5 s as a consequence of which the state of the relay and colour of the LED (e.g. from green to red) would be changed. eleasing the key the relay and LED would return to the previous position. eturn to default Programming would be returned to default if keys A and B are pressed before/during power up. Teaching current value of tripping point Teaching input currents represents saving of current values for switching point 1 and switching point 2 prevailing between terminals (as per right hand drawing) at the moment of the teaching. Necessary current values can be provided by one of the arrangements or by the circuit of the actual application on site. If the input current will be provided by the circuit of the actual application its value have not to be known. = 50 kω + OT A - + G ND + OT I = 1... 22 ma A G ND + - CENT GENEATO Arrangements for teaching input currents To perform teaching, keys A and B should be pressed simultaneously for about 5s until teaching has been entered, indicated by the blinking of LED POGAM. eleasing key B, or. A (only one of them) the momentary current value will be assigned to switching point 1 or. 2. Also releasing the other key, teaching will be completed, indicated by the going off of LED POGAM. Having taught the first current value, the other one can also be taught without quitting teaching, whereas the key already released should be pressed again (for about 5 s) and the other key released Entering teaching Teaching current value for point 1 Quitting teaching Entering teaching Teaching current value for point 2 Quitting teaching Position of key A Position of key B TEACHING STEP LED POGAM LED SELECT LED KEEP PESSED > 5 s OFF OFF blinking GEEN if KEEP PESSED ELEASE OFF SCCESSFL ED blinking if FAILED ELEASE - According to WOKING STATS OFF According to WOKING STATS KEEP PESSED > 5 s OFF OFF blinking KEEP GEEN if SCCESSFL ELEASE OFF PESSED ED blinking if FAILED - ELEASE According to WOKING STATS OFF According to WOKING STATS

6. MAINTENANCE The device does not require maintenance on a regular basis. In some instances, however, the device may need a cleaning from deposited material. 7. STOAGE CONDITIONS Environmental temperature range: -30 C to +60 C elative humidity: max. 98 % 8. PEFOMANCE GAANTEE Since 1986, every instrument sold by HiTECH has been guaranteed to perform in the application it originally was engineered and recommended for. Our company policy remains the same; every product sold comes with a written performance guarantee. Should the equipment be unable to perform satisfactorily in your application and we are not able to correct the problem, we will accept the instrument in return and issue full credit. This performance guarantee is valid for 60 days. Thereafter, our standard limited two years factory warranty goes into effect. HiTECH Technologies, Inc. Tel: 215. 321. 6012; Fax: 215. 321. 6067 Tech Support (Toll Free) 866-DrLevel or 888-NIVELCO